o December 2,1985 DISTRIBUTION:,.e.,
- Docket No.s50-460~
NRC PDR Docket No. 50-460 Local PDR PRC System LB #4 r/f Mr. D. W. Mazur EAdensam Managing Director DHood Washington Public Power Supply System MDuncan Post Office Box 968 Attorney, OELD 3000 George Washington Way JPartlow Richland, Washington 99352 EJordan BGrimes
Dear Mr. Mazur:
ACRS (16)
Subject:
Approval of ASME Code Case N-413, Washington Nuclear Project No.1 By letter dated August 14, 1985, Mr. G. Sorensen requested NRC approval to use ASME Code Case N-413 on WNP-1.
Code Case N-413, " Minimum Size of Fillet Welds for Linear Type Supports,Section III, Division 1," is an acceptable Code Case which is approved as written with no additional requirements other than those specified in the Code Case.
We find that Code Case N-413 may, therefore, be used at WNP-1 for linear type supports within the limitations stated in the " Inquiry" and " Reply" section of the Code Case. Once licensing of WNP-1 is resumed, use of the Code Case should be documented in a future amendment to the FSAR.
Sincerely, Original Signed by Darrell G. Eisenhut for Harold R. Denton, Director Office of Nuclear Reactor Regulation cc:
See next page p
M f
MDbQh DL LB4 OL DL DHood:lb/hmc n
EA sam TNovak
/
11/pg85 11// fan son
/85 11
/85 11 5
1 85 ut 11Q(/85 11g/85 8512100094 851202 PDR ADOCK 050 0
l
~
i Mr. D. W. Mazur WPPSS Nuclear Project No. 1 Washington Public Power Supply System (WNP-1) cc:
Mr. V. Mani Nicholas D. Lewis, Chairman United Engineers & Constructors, Inc.
State of Washington 30 South 17th Street Energy Facility Site Evaluation Philadelphia, Pennsylvania 19101 Council Mail Stop PY-11 Nicholas S. Reynolds, Esq.
Olympia, Washington 98504 Bishop, Liberman, Cook, Purcell and Reynolds 1200 Seventeenth Street, N.W.,
Mr. Eugene Rosolie Suite 700 Coalition for Safe Power Washington, D. C.
20036 Suite 527 408 South West Second Street Mr. E. G. Ward Portland, Oregon 97204 Senior Project Manager Babcock & Wilcox Company Nina Bell P.O. Box 1260 Nuclear Information and Resource Lynchburg, Virginia 23505 Service 1346 Connecticut Avenue, N.W.
Resident Inspector /WPPSS NPS Washington, D. C.
20036 c/o U.S. Nuclear Regulatory Commission P.O. Box 69 Richland, Washington 99352 Mr. R. B. Borsum Nuclear Power Generation Division Babcock & Wilcox 7910 Woodmont Avenue, Suite 220 Bethesda, Maryland 20814 G. E. Craig Doupe, Esq.
Washington Public Power Supply System P.O. Box 968 Richland, Washington 99352 Regional Administrator, Region V U.S. Nuclear Regulatory Commission, 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 a
.,