ML20137V656

From kanterella
Jump to navigation Jump to search
Forwards Reactor Containment Bldg Integrated Leak Rate Test, Conducted on 850629-0711,per 10CFR50,App J.V.B. All Acceptance Criteria Met
ML20137V656
Person / Time
Site: Catawba Duke Energy icon.png
Issue date: 11/21/1985
From: Tucker H
DUKE POWER CO.
To: Adensam E, Harold Denton
Office of Nuclear Reactor Regulation
Shared Package
ML20137V661 List:
References
NUDOCS 8512100051
Download: ML20137V656 (1)


Text

e DUKE POWER Gonnen-P.O.150X 33180 CliAltLOTTE, N.C. 28242

' HAL II. TUCKER retspigo3e d[2."[21",o,,

('*"*~'"'

5MKlf November 21, 1985 Mr. Harold R. Denton, Director Office of Nuclear Regulatory Commission U.

S.

Nuclear Regulatory Commission Washington, D.

C.

20555 Attention:

Ms.

E.

G. Adensam, Chief Licensing Branch No. 4

Dear Mr. Denton:

In accordance with the requirements of 10 CFR 50, Ap]pendix J.V.B, please find enclosed ten copies of the Reactor Containment Building Integrated Leak Rate Test.

The test was conducted from June 29 through July 11, 1985.

All acceptance criteria were met.

Very truly yours,

/

x WL Hal B. Tucker t

WLH:slb Attachments cc:

(w/2 copies of attachmeht) ur.

o.

Nelson urace, xegional Administrator U.

S. Nuclear Regulatory Commission-Region II 101 Marietta-Street NW Suite 2900 i

Atlanta, Georgia

36323, (w/1 copy of attachment)

NRCResidentInsgectortation gc0g Catawba Nuclear

,p w/g+e o,

gobk 00 414 6 0 '"#* *)

21 PDR ggg gy A

(6mmitL) psSo on-)

c8 eg A Rotf4)

Fo B m.

a w,ae ut o~m