Text
.
l METALOGIC aty"lan
- gregne QUALITY CONTROL PROGRAM WTL-QA-2 CONTROLLED DOCUMENT lSSUE HUMBER 8602190188 8$h80 PDR ADOCK O PDR C
1 l
MMTA E ' IMI*"
E Y W E u f l ue l'mo e E u lu tspechoaa:.a 27, s e:ua cne n4v cu.- 33eit NOE Speciahs3 N ': hmN sut:1 doO N M 128 A Livision (f WTL. inc.
QUALITY ASSURAliCE PROGRAF! APPLICABLE TO PROCURE!!E::T USE, !!AI!TfEllAliCE AliD REPAIR OF PACKAGES DESIGliED TO f
TRAliSPORT RADIOGRAPl!IC EXPOSURE DEVICOS F02 IiETALCCIC, A DIVISICII 0;'
.' L, I::C.
275 SOUTI! BLAC:s CA::YC:'.:Ic'. :M PI'OE!'I M, AnI20!:A 83.U9 i
i r
/
//
o j
PREPA!ED DY:
___b
~
3 ATE
. :). LJ. L.T. -
'a.iiatica Caf 2ty 0; 1 car APPROV",D IiY:
DATC J.A.
'~'A'.
C' t.10 r a l a ti.
r DIST2120TIO!! Of CC: T 'OLL. C. D. CCPITw' COPY I:UII:R LOCATIO:1 1
- etaLo jic - Cast Cu_u,t
" m.t r t..a.i t s
c22 f.US 30 c1ea r1Regula to ryiCok_aldt fCIP Ta~ol.iiiQ t'daMUC' 3
Arizona Radition.ejulatory A.jancey T 2....e, /..'
2EVISIO!! 3?ATUS
. ' 7IGIOli TYPE QE REVISIOli L
n'j C
'J L,.,,:,.,,1 1.,
0: IG.
Original Issue 79 123 12-17-115
.:TL ' A-2 Pa;e 1 oc id
ME I 9 M If" la5pect'oa ana 2:s s siack ca von nay 602 253 21:1 svu E sa b auIulu NDE Specialists Pnceni. Jezona 3So09 800 528 5428 A Dicision of CTL,Inc.
CUALIi'Y ASSU:'a;:CC PROC. la 12-17-05
.E'/. C::IG.
Contents Section Sucj2ct 2u Cover 1
Co a ;c a t.:
2 1.0 Or;aaizacion 3
2.J
.:uality.'.aJu ran a : P ro g ra;;,
4 3.3 D o c u::.e n t C o a t r o l 5
4.3
!a n d l _ n t;, 0; ara,o and S a i e p in',
5 5.0 I n a.. a c t i o n, '.' ; a t a n-1 0;: e r a t i n., Jt;.:ua 7
5.0
(:uality Aasurcnce necor.is 0
7.L Auaita 9
Exhioits
?J r.a Ugwr Zua3 2ct L
i-51 m.. '...at't Cartiti;acion IJ
?-53
- J e i v i n,/ C.ii p,, & a, 'ecora 11 P-53
. iud it
'.a c o r a 12
- '- 3 ')
aisjer's Declara;1on 13 Cart. of Co.ag. Aucaority - il 3 -3 14 Cert. of Co;g. Aataority - 913S 15 Cart. of Co..j.
Autnority - 0133 13 Cert. c; Co...p.
Au t;ioricy - 3127 17 Cart. oc Co:..j. Aataority
.i717 la
'.. T L - 0 A-2 Paje 2 of lu
MgEIRAlSgge inspection and N5 S B+ ia Cao rm M Ai UI.'.h K'lli amm lKlumbamIulum NDE Specialists PNxon Arw m 350lH d00 513 i1 3 A Division of WTL. Inc.
CUALITY ASSUPA.';CI.: P:!OGPXi 12-17-05
.CV. O::IC.
1.0 Organization T;ta final rea;.,oncluili;y for c.te luali t;.
.;;uranc2 ?ra.;ra.i for Part 71,aquirei. ente raata ul ti. F.et aLo ;ie.
..a;ija una 23dJrication Silall not 30 ConUiverQu un[.O r t.l i d
. 's Pro j ri. :.
The
~.'.\\
Prog rart is i. vlc..:Ont e, usin, tua ; olla,,la, ar,aaiu-ation:
i i
n I
i 1... ;.r - ).,. r l
.w I, _0
,, t, t A L, l
1 1 o...
.2 v
l
,, G. I o.ca L...u.c _...n..m c :.r. L., I s
l a...
.,3,.
..u..
. u. s I,,0.,,. n l.
. 60,i u u. m...,c i
...o l
a,,ota
..a i
..c,,
., c
't'i.e
. adia tion Sac e ty Uf; ice r la rea unai.;1a -or av2rall ad...inistration of taa,.rujra.:, traininj an.
carti.ieation, docu.aent controi ana auaitinj.
The radiogra.shers are caJpoa;1.>1e f o r itan ;1in;,, ; s c i a.j,
c h i et> i n g, inopoc t ion, test aa. an.1 woratinj a t a c u.,
an ;
reco ro:;eoping.
'L- _/ - 2
.a;u 3 c.
18
MEmlabamI5b NDE Spectahsts 93gau inspection and 275 S Black C.v' yen Huv 602 253-2111 Phoena Ar:lora 85009 300 528 5428 A Division of WTL,Inc.
QUALITY ASSUI!.M;CE Pi!OGI!A:I 12-17.:5
'JV.
O.!I G.
2.0 Quality Assurance Program The.aana.jiaent of :.etaLogic establisilec and 1. c l e.ta n t s c.ii ;
A j rog r a.a.
- Training,
,rior to engacj.. :at, zar all QA iunctions is requircJ in accordance witn Section C, 7L-R.3-1, P.aaiation S a l. a t y.:a n u a l.
.A Prog ra.a reviaioad '.till ue ame in accor ance uica ;,roceaurea cafina 1 i n ',Ti'L - ) A-1,
'u l t i t;
.:,au ranc e..anual.
'.' h i s
..A Pro 3 ra.a t,. ill enJu r e t aat all oefine.
.C,rocomuraa, en,j ine c t in g procadures ano agacitic gravioia:.a the jacNage v i.
.iu.aign ap,>roval a re sat ia f i a.i.
T.. ia.:7.
>rotra.
.till La. ':a n i co t.
coatrol of :aa caaricterutics of cite yacka..e.aica are critical :o safety.
T..e Fa 1;tica Cafet/.czicar ai,all acaura c:.at all raaicactiva
- atarial vai,:f n i
,.i d.;- ; J 3 are. t Ji.jned u.1w
. '. u s a d t u r e..
3 u wdr a
'A P EG j rait a covej.;y t;.e i.uclear..; Liatary Con-ce
.tiuuiva.
CV1..:nCU 02 Co. aiG3 ion a,>,a rov al i.) ;..e 2 0 r *.1 Of CartiJicata; a; Co:.jataat Autaority arc attac..ej aa ja;ca 14 :arou,a 13 for tae Za lo'. tin,:
h Cer 1 1; _a!
D,,2 Iri,iu.,,.3 sou rc -
tu au 1..
o.
saaiou Co;ul:
S.,
caalaa ;0arca J153 14 C2ntury ex,0;ura 2vice 0135 15 Gulc.uclear 2x,.acu r 2
.e-/ ice 913J 13 GI 1:. L u..;adure uayle.2 9127 17
'2 y ce ";" rzo r gac;i 3717 la t.YL-0A-2 Pajc 4 of 1U
ME I2bmImms g gge inspection and 275 S Bath Canc>n Hay tW 253-2111 NDE Specialists Phoou Antena 85009 S00 5.'8 5423 A Division of WTL Inc.
QUALITY ASSURA!;CE PRCGiu!!
12-17-d5
.. u k.
v..,.a..
3.0 Docuacnt Control All docuraents related to a 3,.ccific._ai.Jin.J ac.ca-c iiill ue controlled through che ase of,aroceduras ca u n ine, la
- TL-0A-1, Quality Aassurance i:anual.
.ul Jocu.. ent chanjea shall oe perior:c.eJ in accordance with.roccaurea a :aalia..as.
in li?L-QA-1, Quality Accu rance ;'anual.
The.'.adiation Saf aby Of ficer shall enuare t.:at all
'A lunctions are conductea in accordance.rica :..e la;;,t revisions of taia.aanual,.2L-GA-2, cne saality
'.a d u r.ac e
..anual,1lTL-L!A-1 and the ~:amiation Safety
- anual,
.2L-d-1.
lY L-C. A-2 Paje 5 or la
v M T A Is h am as9Q f inspection and 275 S Bink Cr,on Hay 602 233 2111 NDE Specialists Phoenis Arizona 85009 800 523 5423 A Division of WTL,Inc.
GUALITY ASSURAliCE PROGiW1 12-17-85
.IV. CRIG.
4.0 Ilandling, Storage and Shipping Uritten safety procedures conceraing tae aandling, staraue and shipping of radiograpay coutea; ara Jefia2d ia iection C, Operating and Energency Proce.!ureu,
.aiation Safety I:anuc, UTL-RS-1.
All radiojra,":0 jaraaanci je r.~o r. in j critical 1:andlins, storagc and olily::inu o.arationa saall have in their goceculon a co)y of L'JL-i.J-1, Lection
.7 Ship.aenta of raaio.Jraphy.aourc2a.:r.all act se ;a e c a l c. a.
all teata, cartifications, accei.tanceu
.4.
Jiatl aa...c"ioa; have cean coa,ilatea.
Only radio <Jrcphy per:onnel Jaall pertor.t
- ..e cri:ical aanlling, atoraya and sai.ia; ovarativaa.
,lT L-S A-2
&,a j 2 I) oA 1d
l Mggf Inspection and N5 S Black CJP,M H Ay 602 253-2111 l
ustdessum NDE Specialists f toen,s ANora S5009 8005:S5123 l
A Division of WYL. Inc.
CUALITY ASSURA!!CE PP.OGRA!1 12-17-J5 LEV. 0".IG.
5.0 Inspection, Test and Operating Status Inspection, test and operating an.tua of raaio;ra.ny aources t
and packagea shall be as descriaed in ene.;a:liation Safety IIanual, UTL-RS-1.
Status shall be indicated ay v 103 entry.
Rat.iography personnel shall perfor.? tac re.;ulatory re,uirea inspections and tacts in accon.anca Lith UTL..E-1.
').; a Radiation Safety Officer shall anaure tnat taaee Junctions are perfor;::ed.
' i'J L-() A-2 Page 7 of 13
M M Ia b,lmanf Inspection and 2/5 S Biao Cary;.14 #
60? 25 Omi q
NDE Spmalists Phoems Anzona 85009 300 ;?8 $123 A Olviel:n cf WTL. Inc.
QUALITY ASSURA:!CE P.10Giul!
12-17-15 T.C V. o.tIG.
6.0 Quality Assurance Records Ilecords of packasje a'iravals (in 1ujin:3 case: aacca :nd j
drawings), p ro cu r e r.:ent, inJpection s, teatu, o,.erating _oga, audit results, iarcannel traininj and qualificaticau ana records of Shl ~.cntG C.lall be Jaintainoa inaatiaitley.
Descriptiona oi; e.2u i :.te n t and urict 2n graca.are.; are t
found in the :ta,liation Safety :anual, '.TL-nc-1.
These recordG ara c.aintained in accoraance vict. T L, '.- l.
- c. 11
!!TL-RS-1.
The.ajiation Safety ;>fficer J.ials r as go.u i.-ic for storaje c.n retrieval of L..eJa rJcorca.
.:T L ~.i - 2 Pa ;e U oi. lii
METALDDIC inspottionand 275 S Bao C.iryon Hav nel JS 4 att NDE Speceahsts Phoerts An <:185001 8f)0 528-5 !?S A Dielslon of WTL. Inc.
r CUALITY AssunA:;CC PROGRA:i 12-17-85
,o;V. OLIC.
7.0 Audits An audit scae ;ule as cata:;1isaea ia 1.'TL-2G-1 J. all ae Ju110;i n..
Audit cheerliata shall be naintained by taa aa.liation SuZaty Officer.
- on conforaing items shall be delt with as ;>rovided for in the ;uality Aucurance ::anual, ',iTL-CA-1.
AuJit ire,uency chall uo at least onca per year.
'.;T L-C A-2 Page 9 of 10
v s
pi a
SHIPPER'S CERTIFICATION FOR RADIOACTIVE MATERIALS Two completed and signed copies of this certification shall be handed Io the carrier. 12-17-85 l
OUAliTY ASSURANCE PROGRAM (use block ietteral REV. OMG.
WARNING: Failtce to comply in all respects with the applicable regulations of the Department of
]
Transportation,49-CFR. CAB 82 and, for international shipments, the IATA Restricted Articles Regulations may be a breach of the applicable law, subject to legal penalties. This certification shall in no circumstance be signed by an IATA Cargo Agent or a consolidator for international shipments.
This shipment as within the limitations prescribed for: (mark one)
O passenger aircraft Aed oniaens t maierial et se in. or incioeet to.
Cargo-only airCraf t NATURE AND OUANTITY OF CONTENT PACKAGE
'.O SMPP NaWE AADONUQJOE GAoup FoAW aCTIVifV C a ? EGC d' TYPE FoA U s NaWEoA mp ANO vs CA NLUBE A cF roa iNonsterat ed' 6'
SfE 57cf nit.
oFPAN at
" ' ' f, ryk a Li o
L ot cia a'
L L
y r ap 'fe'o Pane '"I g
- cNYv tv7s e
' #0 *"
""' ' 8 f
s tNcapsut arioN l
ADCITIONAL INFORMATION REOuiPED FOR FISSILE VATEAIALS ONLY EXEMPTEO FROM THE ADDITION AL REQUIREVENTS FOR FISSILE MATERIALS SPECIFIEDIN T.t. OF PART 2 0F THE IATA AESTRICTED AATICLES AEGULATIONS g
NAMES. PLUS QUANTITY IN GRAMS. OR CONCENTRATION OA ENRICHVENT IN U235 Q NOT EXEMPTED.
FISSILE CLASS I _.
FISSILE CLASS la FISSILE CLASS all Additional certificates obtained by the Shipper *nen necessary-Special Form Encapsulation Certificate (s)
T Certificatet p for Large RaSoacti.e Souree Type"B" Packaging Certificate (s)
C Governrnent Approvais/ Perrmts Certificatet s) f or Fissile Material Z
f.9-Special Handhng info'rmation
[
l F
I hereby certify that the contents of this consignment are fully and accurately descriced above cy Proper Shipping Name and are classified, packed, marked, labelled and in proper condition for carrage by air i
3 E
{
according to applicable national governmental regulations, and for international Shipments, the current lAT A g
Restricted Articles Regulations, j
Name and full address of Shipper Name and title of person signing Certification f
fA N
b' f Date Signature of the Shipper (see WARNING above)
...M e.
7 q ;g Air Waybill No.*
Airport of Departure
- Airport of Destination
- hj WTL-QA-2 i
Page 10 of 18
- s. '
Do al tio ing e rYLE DEL
- ChC m A 7, n y),';
,04,
v ggel'nssImmimpuuinA I 9f'EII" laspection and275 s B13< k C.irvn n.sy 602 253-2111 avuE u NOE Spectahsts Phoena Ancona 85009 600 528-5428 A Division of WTL. Inc.
QUALI'fl ASSURMCC PROGRA :
12-17-05 RECEIVIIIC/SHIPPIllG RECORD MV. OFIO.
DECEIVI?iG Scaled Source S/I; Sealed Source Stren:jth Curica C-10 Shipping S/!;
3aaleu Source Type Scaled Source Itodel
!?caleJ Source Size Data Received Laak Teut Jata Date Inapection Leak Tout vy Survey C-10 Sourca Changer or Exposure Jovice At 5"
..1/:L'.
Eea't: Leau chan S..
- /;
f ro::. auriace Sai ping Carrel
?
Surface
'.3/ :: ~.
Ze,'t: Laac t.:an 2JJ
/.;;'
At 3 feet
. 2/lin Raq't: Laua thaa lJ../ :'
If any rea.iinja are excewau follo.I.:. lc rienc Pro cc a u ra ; i.1
- au;atioa 3aluty.anual, Jaction B, Para;ra a 3.
t
..acciving Pe rf ori.lcJ Ly SI!I ? PI:!C 3ato of 3ai alent i
"etaoJ of Saip.aent Ca r rie r ::a;..e Source Strength Curica Survey C-lO Source Changer or Exposure Device At 5" liit/ :n Req't: Laca taan SC 2/:In f ro;a surface Shipping '?arrel Surface
!:It/HP.
.eg't: Leca tilan 2J:). 4 !:/:i;.
At 3 feet tul/lin
- .eg't: Leaa than 1J. P./li t If any readinga are a::cceded follow Ecaergency Procedures ia audiation Saf ety !!anual, Section B, Paragraph 3.C.
Shijping Perforced uy
- lYL-5A-2 P-63 UEV. a Page 11 ot ld
METALD, lf Inspottion and 275 S Black Canon Hu, to? 2512111 uum NDE Specialists Phoenix Areena 35009 300 528 512s A Oleision of WTL,Inc.
QU.%ITY ASSURAI.CS PROGRA!! AUDIT RECORD 12-17-85 CEV. ORIG.
Performed by Data 1.
Training verification 2.
J.sperience varitication 3.
Tecting ve ification 4.
Radio rapaer yearly auJA: varification (Practical rest) u 5.
Personnel E:<posure accords G.
.:anitoring Jevice calibration / records 7.
- uarterly ::aintenance/ Inventory verification in all J u a r t u r.2 8.
Raceiving record; 9.
Leak Test records lJ.
Utilization recorda 11.
Shipping records 12.
I:..lergency situation properly reported 13.
Docu.nentation - Iil:C/ State - Up to Date and properly disburced Co:=ents:
Corrective Action:
i General hanager Signature Date tiTL-r A-2 g
F-68 RZV. ORIG 2/84 Page 12 of 13
QUALITY ASSURANCE PROGRAM Air WeybM No.
12-17-85 REV. ORIG.
Page of Pages Shipper's Reference Number (opsonec Two com and signed copnee of tNs Declarenan must WARNING be hanood to the operator TRANSPORT DETAILS Failure to comply in all respects with the applicable Dangerous Goods Regulations may be in breach of The shipmentis ethin the Nrport of Departure the applicable law, subject to legal penalties. This ione eeen Declaration must not, in any circumstances, be completed and/or signed by a consolidator, a g
{ARGO forwarder or an IATA cargo agent.
R AIRCRAFT ONLY Shioment type ro.* waunceom tinate-'
l NON-RADIOACTIVE l AADIOACTiVE I NATURE AND QUANTITY CF DANGEROUS GOODS Dangerous Goods scenerhcanon Quantrry and Packerg Authonzation Ctase UN Sh f)pe Cf packing Inst.
~ sae A
10 k
8
~
h Addittorial Handling Information h
I hereby declare that the contents of thee consignment are fully and Name/ Title of Signatory accurately described above by proper shopping name and are classified, pecked, marked and labelled, and are in all roepects in the proper Place and Date WTL-QA-2 conetson for transport by air according to the applicable international and National Government Regulations.
Page 13 of 18 Signature (see wames abcwI L.......,.............~e,,
L
US Deportment 4x se.eam sweet sw of IronsportOfm waseg'on 0 C 20590 Research and Specio! Progroms IAEA CERTIFICATE OF CWPETENT AtEHORITY Administration Special Form Radioactive Material Encapsulation Certificate Neber USA /0166/S (Revision 3)
This certifies that the encapsulated sources, as described, when loaded with the authorized radioactive contents, have Men damnstratal to rneet the regulatory requiranents for special form radioactive ::uterial as prescribed in IAEA 1/ ani USA 2/ Regulations for the transport of radioactive nateriaTs.
I. ' Source Description - The sources descri&d by this cer+.ificate are identifieci as tne following Garra Industries models which are mnstructed according to the listed drawing ntrbers:
Fbdel No.
Drawing No.
VD and VD(HP) 602-7001-004 NB, NBG and NB(HP) 602-7001-005 Single Encapsulation thiversal Source 602-7001-006 Double Encapsulation thiversal Source 602-7001-007 Single Encapsulation Side Weld 602-7001-008 All raadels are welded encapsulations mnstructed of 300 series of AP3CO Type 17-4PH stainless steel.
II. Radicactive Contents - The authorized radioactive contents of these sources consist of not r: ore than:
bbdel No.
Contents VD and VD(HP) 300 curies of:
Barium-131 Manganese-54 Cad:rium-109 Phosphorus-32 Calcium-45 Pubidiur.-86 Calcium-47 Seleniur.-75 Cesium-137 Strontium-85 Chlorine-36 Thallium-204 Chrcmium-51 Thulium-170 Iriditn-192 Tin-ll3 Cobalt-60 Ytterbium-169 Iron-59 Zinc-65 OVALITY ASSURANCE PROGRAM 12-17-85 REV. ORIG.
WTL-QA-2 Page 14 of 18
Certificate Number USN'0166/S, Revision 3 Pa9 II.
Fadioactive (bntents (continuM) mdel tb. (con'd)
Contents (cont'd) 18, NBG and NB(HP) 25 Curies kericium-241 30 millicuires Pa-226 500 millicuries Mericum-241 ard Cesium-137 mixture Single m capsulation Universal Source 500 curies Iridium-192 20 curies Ccbalt-60 Ibuble Er. capsulation Universal Scurce 5000 curies Iriditn-192 2000 curies Cchalt-60 Single Dicapsulation Side Wald 500 curies Iridium-192 20 curies Cobalt-60 III. This certificate, unless renewd, expires July 30, 1987.
This certificate is issucd in accordance with paragraph 803 of the IAEA Regulations and in response to the June 7,1982 retition by Ga rna Industries, Baton Pouge, Iouisiana, ard in o3nsideration of tM associated information therein.
Certified by:
!~ 2 h 0cm{ /0 /%
x R. R. RAhL
() (DIGI)
Chief, Padioactive sterials Branch Office of Hazardous sterials Regulations s terials Transportation Bureau 1/ " Safety Series No. 6, Regulations for the Safe Transport of Padioactive Materials,1973 Revised Riition," published by the Interrational Atm.ic Energy Agency (IAEA), Vienna, Austria.
2/ Title 49, Code of Federal Regulations, Part 170-178, USA Revision 0 issual in response to the Septaber 7,1979, petition by Ganma Industries, Baton Rouge, Iouisiana.
Revision 1 issued to add Cesium-137 to mdels VD and VD(HP)
Revision 2 issued to list alternate stainless steel type.
Revision 3 issued to extend expiration date.
n US Deoonment Dongm a s s -* h w 5 *
'U V ' 5' ' :C ^"
Rosearch and special Pragrams IAEA CERTIFICATE OF COMPETENT AUTHORITY Type B Radioactive Materials Package Design Certificate Number USA /9135/B(U)T Revision 0 This establishes that the packaging design described herein, when losded with the ruthorized radicactive contents, has been certified by the National Competent Authority of the United States as meeting the regulatory requirements for Type B packaging for radioactive materials as prescribed in IAEA Regulatioc,s and in cccordance with 49 CFR Sections tions for the transport of radioactive materials.173.393b and 173.394b)(3) of the USA' Regula-I.
Package Identification - Model Nos:
Universal S, and Centry Unive sal SA.
Century S, Century SA, Century IL Packaging Description - Packsging authorized by this certificate consists cf a zirealloy or titaniam "S tube which is surrounded by depleted uranium shielding which is encased in an outer steel housing. The void between the shielding and housing is filled with polyurethane foam.
External dimensions are 7.0 inches long by 5.5 inches in diameter with a gross weight of 45 pounds.
III.
Authorized Radioactive Contents - The autbe-ized contents consist of swial form encapsulations meeting the requirements of 49 CFR 173.339(g) and contairjng not more than 120 curies of iridium-192.
Contents must be of a. design wg/sec or lessieh has been tested and demonstrated to a sensitivity of 10~# atm-em IV.
General Conditions -
Each user of this certificate,must have in his possession a copy of a.
this certif!cate.
b.
Each user of this certificate, other than Gamma Industries, Beton Rouge, LA shallregister his identity in writing to the Office of liazardous Materials Regulation, Materials Transportation Bureau, U.S. Department of Transportation, Washington, D. C. 20590.
This certificate Coes not relieve any consignor or carrier from compliance c.
with any requirement of the Government of any country through or into which the package is to be transported.
QUALITY ASSURANCE PROGRAM 12-17-85 REV. ORIG.
WTL-QA-2 Page 15 of 18
\\'.
(
t' Certificate Number USA /9135/B(U)T, Revision 0 Page 2 V.
Marking and Labeling - The package must bear the marking USA /9135/B(U) as well as the other marking and labels prescribed by the USA Regulations.
VI.
Expiration Date - This certificate, unless renewed, expires on April 30, 1987.
This certificate is issued in accordance with the requirements of the IAEA and USA Regulations and in response to the June 21, 1982 petitior. by Gamma Industries, Baton Rouge, LA and in consideration of the associated info.tr.ation provided in U.S. NRC Certificate of Compliance No. 9135 (Appendix A) nnd re'ated corre-spondence.
Certified by:
. Richard R. Rawl ok Date Chief, Radioactive Materials Branch Office of Hazardous Materials Regulation Materials Transportation Bureau l
1" Safety Series No. 6, Regulations for the Safe Transport of Radioactive Materials, 1973 Revised Edition" published by the International Atomic Energy Agency (IA E A),
Vienna, Austria.
2 Title 49, Code of Federal Regulations. Parts 100-199, USA.
9 d
O h
"[
- *' " is k f h "g *2 k $ 8 {3 i
CERTIFICATE OF COMPLIANCE FO3 RADICACTIVE MATERIALS PACKAGES cantascAta suunseta
- 8tv'S80's 8e**42
- >^CKAGE '04*'CA'CN 88veses.*
e Face asue.esa 9160 0
USA /9160/B(U) 1 2
r e ots eu ogs paces W g
potAaseLE a Th.s certehcJee es stowed to certdy tnet tne pacmageng and contents descriDed en flom S Donow meets me aochcaote safety stancaros set form in Tiene to. Cooe et Foger$ Regulationt Part Ft. Peckageng of Radsoectrue Meternate for Transport and Transponateon of Radioactive Mater
- Under Canaen Condsteopt
- a Thee corshcase ooes nos ree eve one cons gnor from cornphance ween any reau.roment of tne regulations of tRe U S. Oeoartment of Transoonation or otner I
a
.ca
,oguwo,y ag.ncio...nciud.ng m. go,nm.ni of.ny couniry m.ougn o,.nio.n.ca me oscias. w t c. t,.n. con.a
,E l
i'I Y',*ENe7,bNEr**
- "rTNeNe'dNEs.*oN$*c7e=T,Daro.
e 8
Gulf Nuclear, Inc.
Gulf Nuclear Inc. application dated
}
202 Medical Center Boulevard Janua ry 21, 1984, as supplemented.
t Webster, TX 77598
. ooc.,,, -
- 0Noet
- 0'st thee certshC300 et conditional upon fuahthog me roguerevnents of 10 CFR Part 71. as apohcacie, and me conditions specsfied betow (a)
Packaging (1) Model Nos.:
20-VS and 40-VS l
(2) Description i
Radiographic devices and shipping container for sealed sources. The packages are approximately 12" high x 6" wide x 8" long.
The outer case is constructed of 15 gauge 303 stainless steel.
The package is l
provided with a 0.76" diameter handle.
The 34 pound uranium shield is
{
held in place by potting epoxy and,2 brackets within the case. The sealed source is held within a Zircaloy or titanium S-tube by a lockblockj
'p assembly and a safety plug assembly at the opposite end of the S-tube.
g The Model Nos. 20-VS and 40-VS are identical except for shielding i
capability of the uranium shield. The package weighs 42 pounds.
i t
(3) Drawings j
The package is constructed in accordance with Gulf Nuclear, Inc.
l Drawing Nos. A-31, Sheets 3 and 4, Rev.1; A-31-1, Sheets 1 and 2, Rev. 0; A-3-1, Rev.1; A-31-12, Rev. 0; A-31-16, Rev.1; A-31-18, Rev.
I 1; A-31-20, Rev. 1; A-31-21, Sheets 1, 2, and 3, Rev. 1; A-31-31, l'.
Sheets 1, 2, and 3. Rev.1; A-31-32, Rev. 0; A-31-34, Sheet 3 Rev.1 I
and Sheet 4. Rev. 0; 1000-50-14 Rev. 0; and 1000-50-13 Rev. O.
I I
I QUALITY ASSURANCE PROGRAM 12-17-85 f
REV. ORIG.
g 5
I I
WTL-QA-2 g
Page16 of 18 lI I
I I
I I
k
t, ccwomens temwmuea;
?
Page 2 - Certificate No. 9160 - Revision No. 0 - Docket No. 71-9160
(
?
t (b) Contents
[
F (1) Type and form of material
,F T
Iridium 192 sealed source which must be shown to meet the requirements I
of special fann radioactive material.
k (2) tiaximum quantity of material per package One source containing:
(1) Model No. 20-VS package $ 120 Ci; or (ii) Model[No. 40-VS package - 220 C1.
6.
The package model ' designation rust be detennined by the Initial Acceptance f
criteria given in Sect. ion 5.3 (p 5-3) of the application.
7.
The packages authorized by this certiff'cate are hereby approved for use under the general license provisions of 10 CFR 971.12.
i 8.
Expiration datq: April 30,1989.-
REFERENCES Gulf Nuclear,-Inc'. application dated January 21, 1984.
Supplements dated: March 6 and 20, 1984.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION l
Charles E. MacDonald, Chie i
Transportation Certification Branch Division of Fuel Cycle and 11aterial Safety,1415S APR 101984 Date:
i l
.s
7-g
- CERTIFICATE CF CHMPLIANCE}
lI um f "'
Fon RADIOACTIVE MATEllALS PACKA!ES g CWITiFICATE Peumsta e REvaSaQss M -
c PaCA405 topenFiCAfsO*e Peuseen e progpsyuSE3 o TOTAL.syuSO F AGES g k
9127 3
USA /9127/B(U) 1 2
.i
( paa4=m.e I
- a. Th.s cortificate is issued to certsfy inal the pacsateeg and contents seecribed an atom 5 besow. meets tne spot cacie safety standards set fortn en Title 10. Coce
.I
{
of Fecer3 Aegw!ations. Part Ft. - Pecsaging of Macaoactive Matonais for Transport and Transportaten of Aadioactive uatorial under Certs.n Cond.tions ~
l b This cerihcate coes not reiseve tne consignor front cornphance witn any requereenent of the regulations of tne U S. Department of Transportation or otner
,I apphcacae regulatory agencies encludang the governenent of any country inrougn or into enien :ne pecsage weet be transported.
I I
i NEEasI,NOEx
' " "* "'$$YEE","ica 'io."$,$n"o*IoOEic'47,oes
^
n
, Garuna Industries Gama Industries application dated flay 20, 1978 E
i
' P.O. Box 2543 as supplemented.
I
} Baton Rouge, LA 70821 g
j g
lh 71-9127 e ooc 1 uu A ce,,o,T,o,,g i
Thee certihcase is conditenas upon fushshng tne requireewets of 10 CFA Port 71, as sopheacie. and the conditices scoc. fica De+ow f
(a)
Packaging l
(1) Model Nos.:
100, 100A, 200 and 200A 1
i t
1.v (2) Description l$
i 4
A steel encasede uranium shielded radiographic device.
The shipping
!n 3 containers is approximate 1f 21 inches long, 23 inches wide and 42 1
5 L
inches high. The radioactive source assembly is housed in a Zircalloy JE s
or titanium "S" tube. The tube is surrounded by depleted uranium
-l
- .)
metal as shielding raterial.
The depleted uranium shield assembly is
, y encased in a steel housing. The void space between the depleted
, y uraniust shield assembly and the outer container is filled with a lt 7.f polyurethane foam. The gross weight of the contai.ner is 500 pounds.
i N
a4 (3) Drawings l
[,}
's!$i The packaging is constructed in accordance with Garxia Industries Drawing Nos. 821-1001-128 Rev. 4; 821-1001-129, Rev.1; and 180-01 s j
Rev. 1.
,1 i4 l q'1j i
(b) Contents
'l, a (1) Type and form of material Cobalt 60 as sealed sources that meet the requirements of special form
.i radioactive material.
i; l!-
h *'
QUALITY ASSURANCE PROGRAM 12-17-85
- p REV. ORIG.
- I i
WTL-QA-2 i
Page17 of 18 j#
5 b
!N
)5>h
,l ccnomus teontonuee Page 2 - Certificate No. 9127 - Revision No. 3 - Docket No. 71-9127 (2) Maximum quantity of material per package Model No.
Quantity 100 and 100A 100 curies 200'and 200A 200 curies 6.
The source shall be secured in the shielded position of the packaging by the safety plug assembly, source assembly and lockbox assembly.
The components used to secure the source mst be fabricated of materials capable of resisting a 1475'F fire environment for one-half hour and maintaining their positioning function. The ball stop of the source assembly must engage the locking device.
The flexible cable of the source assembly and safety plug assembly mst be of sufficient length and diameter to provide positive positioning of the source in the shielded position 7.
The can and. side plates must be a minimum of 1/4-inch thick carbon steel.
The can and side plates shall be joined by full penetration elds.
All other welds shall be fillet welds having sufficient throat thickness to develop strength equal to or greater than the metals being joined.
8.
The nameplates'shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.
9.
The package authorized by this' certiffcate is hereby approved for use under the general license provisions of 10 CFR 971.12.
10.
Expiration datd: October 3T,1988.
f REFERENCES Gamma Industries application dated May 20, 1978.
Supplement dated:
October 25, 1978.
FOR THE U.S. NUCLEAR REGULATORY C0ttilSSION Charles E. Macbonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date.:
GCT 061383
y3 400 Seveam Sweet S W gg,
4.
wswweoa oc. rosse Research and SpecialPmgrams Administretton IAEA CDtTIFICA2T T CDPE"ENT M7DORITY Type B Radioactive Materials Package Design "b,sp m...,~.,
,..icata Nnster US%M717/ BOO 7 W
...,,,,a.n, (Revisicn 1)
'Ihis establishes that the packaging design described herein, when loadal with the authorized raMwtive contents, has been certified by the Naticnal Cocpetent Authority of the United States, as reeting the regula-tory requirerents for Type B packaging for radioactive naterials as pre-scribed in IAEA 1/ Begulations and SS 49 CFR 173.393a and 173.391(b)(3) of the USA 2f aegulaticns for the transport of r=4i=-tive reterials.
I.
Package Identificaticn - 2dal No. 6717-B.
II.
Packaging Descripticn - Packaging authorized by this certificate consists of an outer 10-ga11cm steel drun with an inner container which is a retaldled container meeting the requirtrents of Ecr Specification 7A, surrourdai by polyurethane filler and a 1-3/2" asbestos free liner.
approximately 75 pounds.
Gross weight is III.
Autl'orized Radicactive Contents
'Ihe authorized contents consist of radioact.tve materials, n.o.s,. as not vore than 200 curies of iridium-192 as sealed sources which nust meet the requirenents for special form as set forth in 49 CFR 173.389(g).
Cbntents aust be of a design whicg has been te'sted and dmonstrated to te leaktight to a sensitivity of 10- atm-cr/sec or less.
IV. General (bnditicns -
Each user of this certificate nIst have in his possession a copf of a.
this certificate.
b.
Each user of this certificate, other than Garma Industries, Baton
!buge, Iouisiana, shall register his identity in writing to the Office of Hazardous Materials Regulation, U.S. Department of Transportaticm, Washington, D.C.
20590.
'Ihis cartificata does not relieve any acnsignor or carrier fran c.
ocmpliance with any recpiremnt of the Goverment of any country through or into *ich the package is to be transported.
V.
Marking and raheling
'!he package nust bear the narking USA /6717/B(U) as w11 as the other mazRing and lab 61s prescribed by the USA Regulaticns.
QUALITY ASSURANCE PROGRAM 12-17-85 REV. ORIG.
WTL-QA-2 Page 18 of 18
Certificate mmber USV6717/B(U)T (Rev.1)
Page 2' VI. Dcpiration Data - This cartificata, unless zunewed, ecpires cm Jttly 31, 1985.
This certificata is issued in accnzdance with the requirerents of the IAEk and USA Regulations and in response to the March 5,1982 petitim by Garma Industries, Batm Rouge, Iouisiana and in crmsideratien of the associated information provided in U.S. mclear Regulatory Cbr:rnission Certificate No.
l 6717 (Appendix A) and related cou.vimme.
Certified by:
1 l
S/
dafG M82 R. R. RAHL (C/CE)'
Chief, Radioactive Materials Branch Office of Hazardous Materials Pegulation Materials Transportation Bureau 1/ " Safety Series No. 6, Begulations for the Safe Transportation of Padioac*:/.-
Faterials," 1973 Bevised Edition published by the International Atmic Energy Agency (IAEA), Vierna, Austria.
2f Title 49, Code of Federal Regulations, Parts 100-199, LSA.
Pevision 1 issued to correct package description.
._