ML20137U359

From kanterella
Jump to navigation Jump to search
Advises That Steam Generator 1,Tube L-23 Plugged During Oct 1985 Inservice Insp,Per Tech Spec 4.4.10.5.a.Complete Results of Insp Will Follow within 12 Months
ML20137U359
Person / Time
Site: Yankee Rowe
Issue date: 11/14/1985
From: Papanic G
YANKEE ATOMIC ELECTRIC CO.
To: Murley T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
FYR-85-130, NUDOCS 8512090279
Download: ML20137U359 (1)


Text

- - - - - - - - _

YANKEE ATO~10 ELECTRIC COMPANY Ta':Pho"' (6 ") * ' -* '00 TWX 710-380 7619 2.C.2.1

..de ~ g'lp,e,,7

/

1671 Worcester Road, Framingham, Massachusetts 01701 ITR 85~130

' ~

e A _... A

-)

O.t J iti:t:

-.d-November 14, 1985 United States Nuclear Regulatory Commission Region I 631 Park Avenuo King of Prussia, PA 19406 Attention:

Dr. Thomas E. Hurley, Regional Administrator References (a) License No. DPR-3 (Docket No. 50-29)

Subject:

Steam Generator Inspection Results

Dear Sir:

In accordance with Technical Specifications 4.4.10.5.a, this letter provides notification on the number of tubes plugged following the inservice inspection of steam generator tubes.

y a result of the October 1985 inservice inspection of Steam Cenerator

  1. 1, one tubs (L-23) was plugged.

Complete results of the steam generator inservice inspection will follow within twelve months in accordance with Technical Specification 4.4.10.5.b.

If you have any questions, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY Georg Papanic, Senior Project Engineer - Licensing Yankee Project I

CP/ba 0512090279 851114 PDR ADOCK 05000029 G

PD,1 i

,0

,f, o l e