l Tennessee Valley Authority, Post omce Box 2000, Decatur, Alabama 35609 2000 April 10, 1997 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

In the Matter of ) Docket Nos. 50-259 Tennessee Valley Authority ) 50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) - MONTHLY OPERATING REPORT FOR THE MONTH OF MARCH 1997 In accordance with the requirements of BFN Units 1, 2, and 3 Technical Specifications, Section 6.9.1.3, TVA is submitting the Monthly Operating Report for the month of March 1997 in the enclosure.

If you have any questions, please call me at (205) 729-2636.

Sip'cerel

/ O T. . Abn p - --

l Mana '~o f Licensir g d Industry Affdirs l

Enclom cc: See page 2 f

/

G e Q bI 150156 9704160020 970331 PDR ADOCK 05000259

R PDH

%IIll[d!!!f!lllIk!!

l

, . U.S. Nuclear Regulatory Commission Page 2 April 10, 1997 Enclosure cc (Enclosure):

Mr. Mark S. Lesser, Branch Chief U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. Frederick J. Hebdon, Director Project Directorate II-4 1 Division of Reactor Projects I-II Office of Nuclear Reactor Regulation, Mail 13 H3 Washington, D.C. 20555 INPO Records Center Institute of Nuclear Power Operations 700 Galleria Parkway l Atlanta, Georgia 30339-5957 l l

Mr. Jim Lang I Director of Engineering and Operations !

Electric Power Research Institute l P. O. Box 10412 l Palo Alto, California 94304 l NRC Resident Inspector Browns Ferry Nuclear Plant 10833 Shaw Road Athens, Alabama 35611 Regional Administrator U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Ms. Elizabeth Hannon Utility Data Institute 1200 G Street, NW Washington, D.C. 20005-3802

s . ENCLOSURE TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT (BFN)

UNITS 1, 2, AND 3 MONTHLY OPERATING REPORT MARCH 1997 (SEE ATTACHED)

I i

A -.

_ . . . _ _ _ - . . _ . . ._ _ _ . _ . _ . ~ _ _ . . . . . . _.-_ _.. _ ._ _.__ m.- _ . . . _ . - . - _ . - -

j - .

i

. . OPERATIONAL SUt+fARY ,

l MARCH 1997 l 1

i BROWNS FERRY 1  :

1 4

' Unit 1 remains shutdown on administrative hold to resolve various TVA'and NRC concerns. Unit 1 has been on administrative

hold since June 1, 1985. As a result, TVA considers that 4

accrual of reporting hours is suspended since the unit has a maximum dependable capacity of zero MWe. Accordingly, TVA '

! does not consider cumulative reporting period hours for the

, period beginning June 1, 1985, when calculating the operating

- -status variables. ,

i I

BROWNS FERRY 2 3 For the month of March, Unit 2 generated 815,730 megawatt hours j- gross electrical power and operated at a net capacity factor of l'

100.7 percent. As of March 31, 1597, Unit 2 has operated continuously for 149 days.

i 4

BROWNS FERRY 3 i

[. For the month of March, Unit 3 generated 425,100 megawatt hours gross' electrical power and operated at a net capacity factor of 52.1 percent. The cycle 7 refueling outage ended at 0240 hours0.00278 days <br />0.0667 hours <br />3.968254e-4 weeks <br />9.132e-5 months <br /> on March 13, 1997. The refueling outage was completed in 19 days and 39 minutes.

l

, , AVERAGE DAILY UNIT POWER LEVEL DOCKET NO: 50-259 UNIT: . BROWNS FEMY 1 PREPARED BY: J. W. Davenoort TELEPHONE: (205) 729-2690 MONTH MARCH 1997 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 0 16 0 l

- 2 0 17 0 3 0 18 , , ,

0 4 0 19 0 l 5 0 20 0 l J

, 6 0 21 0 7 0 22 0 1

3 8 0 23 0 9 0 24 0 10 0 25 0 11 0 26 0 12 0 27 0 ,

i 13 0 28 0 14 0 29 0 15 0 30 0 31 0

. . AVERAGE DAILY UNIT POWER LEVEL DOCKET NO: 50-260 UNIT: BROWN 9 FERRY 2 PREPARED BY: J. W. Davennort TELEPHONE: (205) 729-2690 1

MONTH MARCH 1997 l DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL J (MWe-Net) (MWe-Net) 1 1091 16 1081 2 1089 17 1078 3 1091 18 1085 l

4 1090 19 1087

5 1101 20 1092 6 1081 21 1065 7 1094 22 1090 8 1090 23 1083 9 1088 24 1078 ,

10 1057 25 1082 I i

11 1086 26 1083 1

12 1084 27 1083 13 1084 28 1079

-14 1044 29 1082 15 751 30 1084 31 1680 i

e 4

W

n

,, .. AVERAGE DAILY UNIT POWER LEVEL DOCKET NO: 50-296 UNIT: BROWNS FERRY 3 PREPARED BY: J. W. Davennort

, TELEPHONE: (205) 729-2690 ;

, MONTH MARCH 1997

^

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net) 1 0 16 765 1

2 0 17 915 I

3 0 18 869  !

4 0 19 824 j I

5 0 20 1057 6 0 21 1081 a 7 0 22 1087 8 0 23 1044 9 0 24 1083 10 0 25 1085 l

11 0 26 1089 l 12 0 27 1089 i

{ 13 176 28 1085 14 310 29 1085

,' 15 455 30 1086 31 1084

4

[

4 UNIT SHUTDOWNS AND POWER REDUCTIONS . DOCKET NO: 50-259 REPORT K) NTH: MARCH 1997 UNIT: BROWNS FERRY I ,

PREPARED BY: .L W. Davenoort TELEPHONE: (205) 729-2690

~

Method of License Duration Shutting Event System Component Cause and Corrective Action to Prevent No. Date Type t (Hours) Reasonr Down Reactor 3 Report No. Code' Code' Recurrence 1 06/01/85 5 744 F 4 Ackninistrative hold to resolve various TVA '

i and NRC concerns.

1 i

t

'F-Forced 'A-Equipment Failure (Explain) ' Method: " Instructions for Preparation of Licensee S-Scheduled 3-Maintenance or Test 1-Manual Event Reports (NUREG-1022)~

C-Refueling 2-Manual Scram D-Regulatory Restriction 3-Automatic Scram -

E-Operator Training and License Examination 4-Continuation of Existing Outage F-Ackninistrative 5-Reduction G-Operational Error (Explain) 9-Other H-Other (Explain) i k

1 6

-. _ .. . , _ . _ _ _ _ _ - - ~ _.. . _ _ _ . _ . . . _ . . . _.... .. _ . . _ _ _ _ _ _ . _ . . .__ _ _ . ~ . __ . . . . . . .

. i 3

f t

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO: 50-260 REPORT PONTH: MARCH 1997 UNIT: BROWNS FERRY 2 PREPARED BY: J. W. Davenoort TELEPHONE: (205) 729-2690 i

Met *cd of License ,

Duration Shutting Event System Component Cause and Corrective Action to Prevent NO- Date Type2 (Hours) Reason
Down Reactor 2 Report No. Code' Code' Recurrence 2 03/15/97 5 22 B 5 N/A N/A N/A Power reduction for scheduled Control Rod  ;

Drive Exercise Test.

i t

i i

'f-Forced 'A-Equipment Failure (Explain) 'Hethod: ' Instructions for Preparation of Licensee S-Scheduled B-Maintenance or Test 1-Manual Event Reports (NUREG-1022)

C-Refueling 2-Manual Scram D-Regulatory Restriction 3-Automatic Scram E-Operator Training and License Examination 4-Continuation of Existing Outage >

F-Adninistrative 5-Reduction G-Operational Error (Explain) 9-Other H-Other (Explain)

.- . - . . _ m.._ . . _ , . . . . . m._-.--_ -.._.-_._..-.-m. . __....-__-._..-.--m... _m .._.~.m. -... ..._m. . _ _ _ . . . . .. m.. . . ,

)

s a

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO: 50-296 . ,

REPORT PONTH: MARCH 1997 UNIT: BROWNS FERRY 3 PREPARED BY: J. W. Davenoort .

TELEPHONE: (205) 729-2690 [

t t

i i

Method of License  ;

Duration Shutting Event- System Component Cause and Corrective Action to Prevent  !

No. Date Type' (Hours) Reason: Down Reactor' Report No. Code' Code' Recurrence i

2 03/01/97 5 291.8 C 4 N/A N/A N/A The Unit 3 Cycle 7 refueling outage that began at 0201 hours0.00233 days <br />0.0558 hours <br />3.323413e-4 weeks <br />7.64805e-5 months <br /> on February 22. 1997 continued until 0240 hours0.00278 days <br />0.0667 hours <br />3.968254e-4 weeks <br />9.132e-5 months <br /> on March 13. l 1997. The total length of the refueling outage was 19 days and 39 minutes. >

4 i

i I

r I

i 2F-Forced 'A-Equipment Failure (Explain) ' Method: ' Instructions for Preparation of Licensee .

S-Schedu'ed B-Maintenance or Test 1-Manual Event Reports (NUREG-1022) i C-Refueling 2-Manual Scram l' D-Regulatory Restriction 3-Automatic Scram E-Operator Training and License Examination 4-Continuation of Existing Outage I F-Adninistrative 5-Reduction G-Operational Error (Explain) 9-Other  !

H-Other (Explain) j I

i

l t . /, l s l a ., OPERATING DATA REPORT 1

DOCKET: 50-259 l t UNIT: BROWNS FERRY 1 i

PREPARED BY: J. W. Davenport  ;

.. TELEPHONE: (205) 729-2690 1

OPERATING STATUS I 1. Unit Name: BROWNS FERRY UNIT 1 a 2. Reporting Period: HRRCH 1997

3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross'MWe): 1152 l' 5. Design Electrical Rating (Net MWe): 1065 l 6. Maximum Dependable Capacity (Gross MWe): 0

. 7. Maximum Dependable Capacity (Net MWe): O l 8. If Changes Occur in Capacity Ratings (Items Number )

l 3 Through 7) Since Last Report, Give Reason: N/A

[ 9. Power Level To Which Restricted, If Any (Net MWe): 0

10. Reason For. Restrictions, If Any: Administrative Hold i

THIS MONTH YEAR TO DATE CUMJLATIVE*

11. Hours in Reporting Period 0 0 95743 l l 12. Hours Reactor Was Critical 0 0 59521  ;

4 13. Reactor Reserve Shutdown Hours 0 0 6997 '

14. Hours Generator On Line 0 0 58267 i
15. Unit Reserve Shutdown-Hours 0 0 0 i
16. Gross Thermal Generation (MWh) 0 0 168066787
17. Gross Electrical Generation (MWh) 0 0 55398130 '
18. Net Electrical Generation (MWh) 0 0 53796427
19. Unit Service Factor 0 0 60.9 ,
20. Unit Availability Factor 0 0 60.9  ;
21. Unit Capacity Factor (MDC Net) 0 0 52.8 '
22. Unit Capacity Factor (DER net) 0 0 52.8
23. Unit Forced Outage Rate 0 0 25.6  ;
24. Shutdowns Scheduled over Next 6 Months (Type, Date, and Duration of Each): N/A
25. If Shut' Down At End of Reporting Period, )

' Estimated Date of Startup: To Be Determined Excludes hours under administrative hold (June 1, 1985 to present) i l

- _ _ ~ . . ._ mm . _ _. . . _ . . _ . , .. , _

OPERATING DATA REPORT DOCKET: 50-260 .

UNIT: BROWNS FERRY 2 j PREPARED BY J. W. Davenport TELEPHONE: (205) 729-2690 l 1

OPERATING STATUS 6

1. Unit Name: BROWNS FERRY UNIT 2
2. Reporting Period: MARCH 1997
3. Licensed Thermal Power (MWt): 3293
4. Nameplate Rating (Gross MWe): 1152 i 5. Design Electrical Rating (Net MWe): 1065 I
6. Maximum Dependable Capacity (Gross MWe): 1098.4
7. Maximum Dependable Capacity (Net MWe): 1065
8. If Changes occur in. Capacity Ratings (Items Number f 3 Through 7) Since Last Report, Give Reason: N/A
9. Power Level To Whi a Restricted, If Any (Net MWe): N/A
10. Reason For Restric:.i"ns, If Any: N/A l THIS )ONTH YEAR TO DATE cut 4JLATIVE*
11. Hours in Reporting Period 744.0 2160.0 141775
12. Hours Reactor Was Critical 744.0 2160.0 100809
13. Reactor Reserve Shutdown Hours 0.0 0.0 14200
14. Hours Generator On Line 744.0 2160.0 98443 15.' Unit Reserve Shutdown Hours 0.0 0.0 0 '
16. Gross Thermal Generation (MWh) 2422896.0 6759960 290947060
17. Gross Electrical Generation (MWh) 815733.0 2272620 96693988
18. Net Electrical Generation (MWh) 797573.0 2219603 94052768
19. Unit Service Factor 100.0 100.0 69.4
20. Unit Availability Factor 100.0 100.0 69.4
21. Unit Capacity Factor (MDC Net) 100.7 96.5 62.3
22. Unit Capacity Factor (DER net) 100.7 96.5 62.3
23. Unit Forced Outage Rate 0.0 0.0 14.7
24. Shutdowns Scheduled Over Next 6 Months (Type, j Date, and Duration of Each): Unit 2 cycle 9 Refueling Outage Scheduled to l begi's on September 21, 1997, 23.8 days duration f l
25. If Shut Down PJ End Of Reporting Period, Ettimated Date of Startup: N/A i

Excludes hours under administrative hold I (June 1, 1985 to May 24, 1991) i t

r

. _.~__..m .- __._m. - - . _ - _ _ _ _ . _ _ _ . . _ . _ . . . _ _ _ _ .. <._ _. _

i

. . 7 e l i

l OPERATING DATA REPORT I

DOCKET: 50-296 ,

UNIT: BROWNS FERRY 3 ,

PREPARED BY: J. W. Davenport j TELEPHONE: (205) 729-2690 i OPERATING STATUS

1. Unit Names BROWNS FERRY UNIT 3
2. Reporting Period: MARCH 1997  !
3. Licensed Thermal Power (MWt): 3293 '
4. Nameplate Rating (Gross MWe): 1152
5. Design Electrical Rating (Net MWe): 1065 i
6. Maximum Dependable Capacity (Gross MWe): 1098.4 }
7. Maximum Dependable Capacity (Net MWe): 1065 I
8. If Changes Occur in Capacity Ratings (Items Number j 3 Through 7) Since Last Report, Give Reason: N/A
9. Power Level To Which Restricted, If Any (Net MWe): N/A
10. Reason For Restrictions, If Any: N/A j

THIS WNTH YEAR TO DATE CUWLATIVE*

11. Hours in Reporting Period 744.0 2160.0 84997
12. Hours Reactor Was Critical 470.0 1720.0 56474 ^
13. Reactor Reserve Shutdown Hours 0.0 0.0 5150 l
14. Hours Generator On Line 452.2 1702.2 55121  !
15. Unit Reserve Shutdown Hours 0.0 0.0 0 l
16. Gross Thermal Generation (Mwh) 1279104.0 4723296 165953953
17. Gross Electrical Generation (}cm) 425100.0 1552590 55576730
18. Net Electrical Generation (MWh) 412502.0 1508215 53190346
19. Unit Service Factor 60.8 78.8 64.9 1
20. Unit Availability Factor 60.8 78.8 64.9
21. Unit capacity Factor (MDC Net) 52.1 65.6 58.8
22. Unit Capacity Factor (DER net) 52.1 65.6 58.8
23. Unit Forced Outage Rate 0.0 0.0 10.3
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each): N/A