_ _ _ _ _.

._

_

_

. . _ _ __ _ . _ _ . - _ _ _

_

.

____

J

Ot0

]

,

.

-

I

April 8, 1997

.

F

Mr. H. G. Stanley .

. Site Vice President

Braidwood Nuclear Power Station

Commonwealth Edison Company .

R.R. #1, Box 84

Brecoville,IL 60407

,

F

' SUBJECT:

NRC BRAIDWOOD EMERGENCY PREPAREDNESS INSPECTION REPORTS

i

50-456/97004 (DRS); 50-457/97004(DRS) AND NOTICE OF VIOLATION

l

1

Dear Mr. Stanley:

.

' On March 7,1997, the NRC completed an inspection at your Braidwood Generating

,

,

Station, Units 1 and 2. The enclosed report presents the results of that inspection.

. , .

Areas examined during the inspection are identified in the report. Within these areas, the

inspection consisted of a selective examination of procedures and representative records,

'

- interviews with personnel, and observation of activities in progress.

l

!

This inspection was to perform the emergency preparedness core inspection in NRC

'

inspection Procedure 82701 and review the status of previous open inspection findings.

The report's Executive Summary provides an overview of our assessment of your

'

i

performance in Emergency Properedness, an aspect of Plant Support. At the conclusion of

,

the inspection the findings were discussed with those members of your staff identified in

the report.

4

,

The emergency ' preparedness program was effective in maintaining and improving

'

operational readiness of your emergency response facilities, equipment, and personnel.

i

Emergency response facilities, equipment, and supplies were in excellent material

,

,

condition. Interviews with emergency response personnel demonstrated excellent

1

"

[

' knowledge of emergency implementing procedures and responsibilities. Management

support was clearly a factor in the program's improvement over the last two years.

!

'

i

However, a problem was identified with the 1996 Site Quality Verification' audit of the

emergency preparedness program.

,

. Based on the results of this inspection, certain of your activities appeared to be in violation

j

'

.

of NRC requirements, as specified in the enclosed Notice of Violation (Notice). The

.

' violation concems the failure to evaluate, document, and report to corporate and plant

management the adequacy of interface with the State govemment,

i

)

.You are required to respond to this letter and should follow the instructions specified in the

7

enclosed Notice when propering your response, in your response, you should document

.

the specific actions taken and any additional actions you plan to prevent recurrence. After

i

j

reviewing your response to this Notice, including your proposed corr

results of future inspections, the NRC will determine whether further NRC enforcement

i

'

action is necessary to ensure compliance with NRC regulatory requirements.

i

9704150306 970408

9

'PDR

ADOCK 05000456

appupppppp >f

<

G

PDR

"

!

-

..

.1.

, . _ _ .

- .

~ .

.

-

.

.

. . _ , . . _ . . _ _

,.,

...-.,_.-...._a_'

-

.

.

H. G. Star $ ley

-2-

April 8, 1997

"'

in accordance with 10 CFR 2.790 of the NRC'S " Rules of Practice," a copy of this letter

and the enclosures will be placed in the NRC Public Document Room (PDR).

Sincerely,

/s/MelvynLeach(for)

Geoffrey E. Grant, Director

Division of Reactor Safety

Docket Nos. 50 456; 50 457

y

4

Licenses No. NPF-72; NPF-77

i

Enclosures:

1. Notice of Violation -

t

2. Inspection Reports 50-456/97004(DRS); 50-457/97004(DRS)

i

b

cc w/encis:

T. J. Maiman, Senior Vice President,

'

Nuclear Operations Division

D. A. Sager, Vice President,

Generation Support

.

'

H. W. Keiser, Chief Nuclear

l

Operating Officer

>

T. Tulon, Station Manager

i

T. Simpken, Regulatory Assurance

i

Supervisor

)

1. Johnson, Acting Nuclear

l

4

Regulatory Services Manager

>

<

Document Control Desk - Licensing

'

4

Richard Hubbard

!

Nathan Schloss, Economist,

!

4

Office of the Attorney General

i

State Liaison Officer

Chairman, Illinois Commerce Commission

l

Distribution:

-

Docket File w/encls

Rill PRR w/encls

C. D. Pederson, Rlli w/encls

l

4

PUBLIC IE-35 w/encls

SRis, Braidwood, Byron,

Rlli Enf. Coordinator w/encls

j

,

OC/LFDCB w/encls

Zion w/enci s

R. A. Capra, NRR w/encls

i

DRP w/encls

LPM, NRR w/encls

TSS w/encls

i

DRS w/encls

CAA1 w/encls

A. B. Beach, Rlll w/encls

j

i

DOCUMENT NAME: G:DRS\\ BRA 97004.DRS

.

To receive a copy of this document, Indicate in the box: "C" = Copy without

l

'

attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy

l

.=

OFFICE

RIII

lE RIRjf

l

RIII

lo'RIII

l+

l

NAME-

RJickling:jpfl

JCr(IS-

RLanksburyWM4

MLeach/GGrant/me

!

DATE c3tL44/n /97

O

OQ M /97

$#3h/ /97

04/ o 8 /97

,

0FFICIAL MCORD COPS

l

l

--

. - - - . . -

.

-

-

.-