o.r SEABROOK STATION Engineering Office PtbOc Service of New Hampshbo November 19, 1985 SBN-897 New Hompshire Yankee Divh T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I j

631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Project and Resident Programs

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) PSNH Letter SBN-749," Interim 10CFR50.55(e) Report, Control Rod Drive Mechanism, Heavy Drive Screw, Breech Guide Screw," J. DeVincentis to R. W. Starostecki, dated January 15, 1985 (c) IE Information Notice No. 85-14, " Failure of a Heavy Control Rod (B C) Drive Assembly to Insert on a Trip 4

Signal," dated February 22, 1985

Subject:

Final 10CFR50.55(e) Report, "ControlRodDriveMechanism,Heavk-Drive Screw, Break Guide Screw" (CDR 84-00-18) y

Dear Sir:

We previously reported [ Reference (b)] a potential 10CFR50.55(e) item associated with the breech guide screw on the control rod drive mechanisms.

The NRC issued IE Information Notice No. 85-14 [ Reference (c)] to address all nuclear power facilities. In Reference (c), a Westinghouse procedure was referred to which required the drilling of a hole in the breech guide screw at least 90 degrees from the existing hole. A locking pin was to be inserted into the new hole and the pin welded in place. This procedure has been performed on all the control rod drive assemblies for Seabrook Units 1 and 2 to eliminate the concerns addressed in IE Information Notice No. 85-14.

l 1

8512050249 851119 PDR ADOCK 050 3

S l

P.O Box 300 Soobrook.NH03874 Telephone (603)474 %21 Wl

\\

1

.w United States Nuclear Regulatory Commission Attention: Mr. Richard W. Starostecki Page 2 This is our final report on this item.

Very truly ours, N( Y2 J

John DeVincentis, Director Engineering and Licensing cc:' Atomic Safety and Licensing Board Service List

. Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington,,DC 20355 r.

l.

l l

l

=

w e

w w 4 e

c Le William S. Jordan, III Donald E. Chick Diane Curran Town Manager Harmon, Weiss & Jordan Town of Exeter 20001 S. Street, N.W.

10 Front Street Suite 430 Exeter, NH 03833 Washington, D.C.

20009 Brentwood Board of Selectmen Robert G. Perlis RED Dalton Road Office of the Executive Legal Director Brentwood, NH 03833 U.S. Nuclear Regulatory Commission Washington, DC 20555 Richard E. Sullivan, Mayor City Hall Robert A. Backus, Esquire Newburyport, MA 01950 116 Lowell Street

-P.O.. Box 516 Calvin A. Canney Manchester, NH 03105 City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Augusta, ME 04333 Dana Bisbee, Esquire Mr. John B. Tanzer Assistant Attorney General Designated Representative of Office of the Attorney General the Town of Hampton 208 State House Annex 5 Morningside Drive Concord, NH 03301 Hampton, NH 03842 Anne Verge, Chairperson Roberta C. Pevear Board of Selectmen Designated Representative of Town Hall the Town of Hampton Falls South Hampton, NH 03827 Drinkwater Road.

Hampton Falls, NH 03844' Patrick J. McKeon Selectmen's Office Mrs. Sandra Gavutis 10 Central Road Designated Representative of Rye, NH 03870 the Town of Kensington RFD 1 Carole F. Kagan, Esquire East Kingston, NH 03827 Atomic Safety and Licensing Board Panel "U.S. Nuclear Regulatory Commission Jo Ann Shotwell, Esquire Washington, DC 20555 Assistant Attorney General Environmental Protection Bureau Mr. Angi Machiros Department of the Attorney General Chairman of the Board of Selectmen One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Town Manager's Office U.S. Senate Town Hall - Friend Street Washington, DC - 20510 Amesbury, MA 01913 (ATTN: Tom Burack)

Senator Gordon J. Humphrey Diana P. Randall 1 Pillsbury Street I

70 Collins Street

' Concord, NH 03301 Seabrook, NH 03874 (ATIN: Herb Boynton)

)

-