ML20137Q156
| ML20137Q156 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 01/30/1986 |
| From: | Verrelli D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | White S TENNESSEE VALLEY AUTHORITY |
| References | |
| GL-83-28, NUDOCS 8602060038 | |
| Download: ML20137Q156 (4) | |
Text
'
thrsw 50-327 JAN 3 0 4ang Tennessee Valley Authority
/ ATTN:
Mr. Steven A. White Manager of Power and Engineering (Nuclear) 6N38 A Lookout Place 1101 Market Street Chattanooga, TN 37402-2.801 Gentlemen:
SUBJECT:
GENERIC LETTER 83-28 INSPECTION AT SEQUOYAH NUCLEAR PLANT This letter is to inform you of our plans to conduct a special inspection of your actions as a result of Generic Letter 83-28, Required Actions Based on Generic Implication of Salem ATWS Events.
The actions covered by this letter fall into the following four areas:
1.
Post-Trip Review 2.
Equipment Classification and Vendor Interface 3.
Post-Maintenance Testing 4.
Reactor Trip System Reliability The inspection will be conducted at your Sequoyah plant during the period of February 3-7, 1986, by a four-member team led by Mr. Norman Merriwcather of this office.
During our inspection we normally review procedures and documentation associated with the four areas listed above.
It would be appreciated if information applicable to these areas be readily available for our inspector's use.
For information not available at the site, we request that the team be notified upon their arrival so further arrangements can be made.
We have found it helpful if information (similar to enclosures) is provided which identifies applicable procedures, licensee contacts, and telephone numbers of those who are familiar with the licensees' effort in each of the categories listed in the Generic Letter.
Additionally, our team will observe selected portions of safety-related main-tenance that may be scheduled or in progress during the period which they are at the site.
The team will request to observe the performance of.your maintenance procedure for the Reactor Trip Breakers or other breakers of the same type by knowledgeable maintenance personnel. Where this is not feasible, our team will ask for a " walk-through" demonstration.
Your cooperation in making your records and staff available to support this inspection is appreciated.
8602060039 G60130 PDR ADOCK 0500 7
I Y LEol
p _ _
J/< N 3 01986 Tennessee Valley Authority 2
Any questions you may have or coordination efforts you would like to clarify should be referred to Mr. Steve Weise of our office.
Sincerely, t
D David M. Verrelli, Chief Reactor Projects Branch 1 Division of Reactor Projects
Enclosures:
1.
Sample Outline of Generic Letter 83-28 with Cognizant Personnel ~
and Applicable References 2.
Sample of Other Documentation and Points of Contact c w/encis:
jH.L.Abercrombie,SequoyahNuclearPlant Site Director P,' R. Wallace, Plant Manager
.vR. W. Whitt, Chief, Nuclear
- Safety Review Staff
. L. Williams, Jr., Supervisor Licensing Section
. B. Kirk, Compliance Staff Supervisor j
. E. Wills, Project Engineer cc w/encls:
. N. Grace
. R. Denton, NRR i
. L. Thompson, NRR
). M. Taylor, IE
'vB B. Hayes, 01 dkCResidentInspector Document Control Desk State of Tennessee 4
RII JII
- RII, RI
%v 76 k (M
NMerf weather:1b LFoster TConlon AHerdt i
01////86 01/#//86 01
/86 Olfgf/86
r o
ENCLOSURE 1 SAMPLE OUTLINE OF GENERIC LETTER 83-28 WITH COGNIZANT PERSONNEL AND APPLICABLE REFERENCES GL 83-28 ITEM / SUBJECT REFERENCE POINT OF CONTACT.
1.1 Post Trip Review ADM-14 Supt Ops, Dave Christian, X-215 Supv SES, Doug Rickeard, X-288 1.2 Data and Info Response to Supv SES, Doug Rickeard, X-288 Capability GL S3-28 2.1A EQPT Class (RTS)
ADM-73 Supv SES, Doug Rickeard, X-288 2.1B Vendor Interface ADM-93 Supv Records, Ed DeWandel, X-217 ADM-66 Supv Records, Ed DeWandel, X-217 ADM-48 Lic Coord, Buster Bilyeu, X-451 2.2.1 EQPT Class,(All)
ADM-73 Supv,-SES, Doug Rickeard, X-288 ADM-79 Supv Eng Plan, Mike Carson, X-500 ADM-86 Supt Maint, Wayne Kibler, X-214 ADM-61.3 Supv Maint Svce, Dick Mudd, X-447 2.2.2 Vendor Interface ADM-93 Supt Records, Ed DeWandel, X-217 DM-73 Supt SES, Doug Rickaerd, X-288 3.1 Post Maint Testing PC-DB-E/A1 Elect Eng, Joe DeMarco, X-557 3.2 Post Maint Testing ADM-89 Elect Eng, Joe DeMarco, X-557 ADM-89.7 Elect Eng, Joe DeMarco, X-557 ADM-89.8 Elect Eng, Joe DeMarco, X-557 ADM-86 Supt Maint, Wayne Kibler, X-214 4.1 Reliability PT-27.1 Elect Eng, Joe DeMarco, X-557 4.2-Rx Trip System PC-DB-E/A1 Elect Eng, Joe Demarco, X-557 Reliability PT-8.2 & 8.2 Supt Tech Sycs, Mike Kansler, X-27 PT-2.34 Supt Tech Svce, Mike Kansler, X-27 4.2.3&4 Life Cycle Testing W OG Due to Richmond, Bob Nichols, X-450 utilities by i
10/18/84 4.3 Auto Shunt Trip Mod Elect Eng, Joe DeMarco, X-557 Auto Shunt Trip Testing Supt Projects, Gene Grecheck, X-204 i
l l
l E-
f s'
I ENCLOSURE 2 OTHER DOCUMENTATION AND POINTS OF CONTACT ITEM / SUBJECT REFERENCE POINT OF CONTACT FSAR Chap 14 in Place Lic Coord, Buster Bilyeu X-451 Tech Specs In Place Lic Coord, Buster Bilyeu, X-451 Engineering. Specs Supt SES, Doug Rickeard, X-288 Vendor Tech Manuals Supy Records, Ed DeWandel, X-217 Design & Instln Drawings DC Eng,. Don Padula, X-277 In Place Procedures In Place (or Indices)
Admin Asst, John Costello, X-383 Procurement Records Supv, Main Sycs, Dick Mudd, X-447 Design Change for RTS DC 83-26 " Timing DC Eng, Dick Coupe, X-285 Reliability Circuit Rx Trip Breakers" DC 84-06 & DC 84-07 3
" Auto Actuation Recctor Trip Breaker Shunt Trip" Recent Work Orders Supv Eng Plan, Mike Carson, X-500 QA Matters Supv QC, Alan Price, X-254 EQPT Classification Supv SES, Doug Rickeard, X-288 irs, LERs Supv SES, Doug Rickeard, X-288 Copy of Response In Place Lic Coord, Buster Bilyeu, X-451 PM Demonstration Supt Maint, Wayne Kibler, X-214 Maint Schedules Elect Eng, Joe DeMarco, X-557
-QA Audit Schedules Supv QC, Alan' Price, X-254 Off-Site Contact Richmond, Dave Speidell, 81-4045 Richmond, Bob Nicholls, X-410
,.. -. -.. -