Text
- -
ag DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED r
U[
UNITED STATES
.j g
j NUCLEAR REGULATORY COMMISSION l
WASHINGT0N. D.C. 206sH1001
%...../
April 4, 1997 H
General Electric Company ATTN: Mr. C.P. Kipp, General Manager General Electric Nuclear Energy Production P.O. Box 780 Wilmington, NC 28*02
SUBJECT:
NRC MC&A INSPECTION REPORT NO. 70-1113/97-201
Dear Mr. Kipp:
A routine inspection of your facility's material control and accounting (MC&A) safeguards program was conducted by the Nuclear Regulatory Commission on March 3-7,1997. The enclosed report presents the results of that inspection.
Within the scope of the inspection, one apparent violation, one apparent non-cited violation, one unresolved item, and two inspector follow-up items (IFis) were identified by the inspectors. The violation pertains to the failure of the MC&A Department to adequately review a Chemet Laboratory procedure to ensure consistency of the procedure with the Fundamental Nuclear Material Control Plan.
With regard to the violation, you are required to respond to this letter, and should follow the instruction specified in the enclosed " Notice f Violation," (Enclosure 3) when preparing your response. In the response, you sh uld document the specified actions taken for the violations and any proposed actions to prevent recurrence.
i, DOCUMENT TRANSMITTED HEREWITH
[,
CONTAINS 2.790 INFORMATION 090095 DECONTROLLED WHEN 2.790 INFORMATION ENCLOSURES ARE REMOVED ggtgy% W agepan-sa 4g
. DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED General Electric Company Under the provisions of Section 2.790(d), reports containing information related to a licensee's MC&A program are exempt from public disclosure. Accordingly, the enclosure will Dal be placed in the Public Document Room.
Should you have any questions concerning this letter, please contact me.
Sincerely, Philip Ting, Chief Operations Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket No. 70-1113 License No. SNM-1097
Enclosure:
As stated cc w/ enclosure:
R. Reda, General Electric l
cc w/o enclosure: State of North Carolina l
DISTRIBUTIQB:
Case File FCSS r/f NMSS r/f FCOB r/f ENRC Mie'Cente' ?A MWeber TPham EEckfeld r
EMcAlpine, Ril Docket.7011113 LPDR & PDR1w/o encl):
CCollins DWhaley YChen MMessier, LFDB (w/o encl)
DOCUMENT NAME: A:GE97-201.rpt
- SEE PREVIOUS CONCURRENCE OFC FCoB E
FCOB E
FCoB E
Fcos 6-kC udill*
LOng kr WSchwink NAME DATE 3 3//97 3 A797 4 /4/97 4/97
/
DOCUMENT TRANSMITTED HEREWITH CONTAINS 2.790 INFORMATION L
DECONTROLLED WHEN 2.790 INFORMATION IS REMOVED
.j