OPERATING DATA REPORT DOCKET NO. 50-266 DATE: 04/01/97 COMPLETED 8Y: M. B. Koudelka TELEPHONE: 414-755-6480 OPERATING STATUS
- 1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1 NOTES
- 2. REPORTING PERIOD: March - 1997
- 3. LICENSED THERMAL POWER (MWTI: 1518.5
- 4. NAMEPLATE RATING (GROSS MWE): 523.8
- 5. DESIGN ELECTRICAL RATING (NET MWE): 497.0
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 509.0
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 485.0
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
NA
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NA
- 10. REASONS FOR RESTRICTIONS, (IF ANYl:
NA THIS MONTH YEAR TO DATE CUMULATIVE
- 11. HOURS IN REPORT'.NG PERIOD 744.0 2.160.0 231.432.0
- 12. NUMBER OF MOORS REACTOR WAS CRITICAL O.0 1.416.0 194.289.9
- 13. RC.K OH RESERVE SHUTDOWN HOURS 0.0 0.0 667.3 i4. HOURS GENERATOR ON LINE O.0 1.151.0 190,806.0
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 1,558,331.0 271.052,716.0
- 17. GROSS ELECTRICAL ENERGY GENERATED O.0 534,720.0 91.625.810.0
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 0.0 497,884.0 87.354,303.5
- 19. UNIT SERVICE FACTOR O.0%
53.3 %
82.4 %
- 20. UNIT AVAILABILITY FACTOR O.0%
53.3%
82.8 %
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0%
47.5 %
77.5 %
- 22. UNIT CAPACITY FACTOR (USING DER NET) 0.0%
46.4%
75.9 %
- 23. UNIT FORCED OUTAGE RATE O.0%
18.7 %
1.6 %
- 24. SHUTDOWNS SCHEDULED OVFR NEXT 6 MONTHS (TYPE, DATE. AND DURATION OF EACH):
Refueling. 09/06/97. 49 days
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
07/01/97 DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DAlED SEPTEMBER 22,1977 9704090274 970403 PDR ADOCK 05000266 R
m e
1 POINT SEACH NUCLEAR FLANT DOCKET NO.
' 50-266 -
AVERAGE DAILY UNIT POWER LEVEL UNIT NAME Point Beach Unit 1 MONTH MARCH-1997
.DATE 4/3/97 COMPLETED BY M. B. Koudelka TELEPHONE -
414 755-6480 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY -
POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1
-14 11
-12 21
-14 2
-10 12
-13 22
-14 3..
-18 13
-15 23
-14
- 4
-14 14
-15 24
-11 i
5
-13 15
-17 25'
-8 6
-13 16
-12 26
-8 7
-12 17
-14 27 8
-13 18
-14 28 8
9-
-13 19
-13 29
-8 10
-12 20
-14 30 8
31-
-8 i
t 6
I I
m--
..-.. -....m.
-. 2 --.
mu
-.n<
w-s
.e.
>mer-
.rw y.-
,--.c s.
--,,~w w.
. r-r em
POINT BEACll NUCLEAR PLANT "
Docket No;--50-266 -
Unit Name Ibin Ileach. Unit i IINIT SRKTH) OWNS ANI) POWFJR REDUC'HONS
~ Date X Jnril 1 1997 '
Completed By ~ Mt. B. Kou<a --
~ {
REPORT MONTil M ARCII - 1997 '
Telephone No.. q Al4/755-643).
- Mcttsal 4 C""**
- ~
.Shunmg 1.kenice Event Syssem Cisle' To Present Recumnce
""I a
- No..
" Duee
' Type'.
y-Down Reput No.
Cimic o.
^2 9A1218 F:
744
.H i
NA tina renuined in hot shunkswa met taen so caAt dunamn on March 1S,1997.
=
i 4.
+i I
t i
l
'F: Forced
' ' Reason:
' Method:
" Exhibit G - Instructions S: Scheduled A - Equipment Failure (explain) 1 - Manual for preparation of G 4 saintenance or Testing 2 - Manual Scram data entry sheets
'I C - Re. fueling 3 - Automatic Scram LER file (NUREG-0161)
D - Regulatory Restriction 4 - Continuation of '
E - Operator Training &
Previous Shutdown Licensing Exam 5 - Reduced Load F-Administrative 6 - Other (explain)
' Exhibit I - Same Source
[
G - Operational Error (explain)
II - Other (explain) r f
?
t
-?
?
i t
I-l t
I i
t i
P t
I~
PitF4U28b I
t03 G) -
l L
l
.- -. - - -. =. - -..
. -....... -..... -. = -.
~
DOCKET NO.
50-266
.. UNIT NAME-Point Beach Unit 1 i
DdTE 04/03/97 COMPLETED BY M. B. Koudelka.
TELEPHONE 414/755-6480
'. Unit I was in hot shutdown and taken to cold shutdown during the March.1997 report period.
The following Licensee Event Reports were submitted to the NRC in March,1997:
Licensee Event Report 50-266/97-008-00, Non Seismic Ductwork Located Above Safety-Related-Equipment in Containment.
4 -
~ Licensee Event Report 50-266/97-009-00, Potential Safety injection Failure During Filling of Safety injection Accumulator.
Licensee Event Report 50-266/97-010-00. Service Water and Component Cooling Water Technical Specifications Action Requirements Not Met.
Safety-related maintenance included:
1.
G-03 emergency diesel generator outer bearing replaced.
i 2,
1P-2B charging pump seals replaced.
3 P-32F service water pump balanced.
4.
P-38A-M motor-driven auxiliary feedwater pump motor vibration and motor current tests.
r t
4 w
a
OPERATING DATA REPORT DOCKET NO. 50-301 DATE: 04/01/97 COMPLETED BY: M. B. Koudelka TELEPHONE: 414-755-6480 OPERATING STATUS
- 1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 2 NOTES
- 2. REPORTING PERIOD: March - 1997
- 3. LICENSED THERMAL POWER (MWT): 1518.5
- 4. NAMEPLATE RATING (GROSS MWE): 523.8
- 5. DESIGN ELECTRICAL RATING (NET MWE): 497.0
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 509.0
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 485.0
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
NA 9 F0WER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): NA
- 10. REASONS FOR RESTRICTIONS. (IF ANYl:
NA THIS MONTH YEAR TO DATE CUMULATLVE
- 11. HOURS IN REPORTING PERIOD 744.0 2.160.0 216.217.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL O.O O.0 185,987.6
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 233.9
- 14. HOURS GENERATOR ON LINE O.0 0.0 183.508.3
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 0.0 263,605.007.0
- 17. GROSS ELECTRICAL ENERGY GENERATED O.0 0.0 89,603,310.0
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 0.0 (4,669.0) 85,406,914.5
- 19. UNIT SERVICE FACTOR O.0%
0.0%
84.9 %
- 20. UNIT AVAILABILITY FACTOR O.0%
0.0%
85.0 %
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0%
-0.4 %
80.9 %
- 22. UNIT CAPACITY FACTOR (USING DER NET) 0.0 %
-0.4 %
79.5 %
- 23. UNIT FORCED OUTAGE RATE O.0%
0.0 %
0.9%
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACHl; None
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
05/17/97 DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED SEPTEMBER 22,1977
~
- POINT BEACH NUCLEAR PLANT DOCKET NO.
'50-301
?
I AVERAGE DAILY UNIT POWER LEVEL UNIT NAME Point Beach, dnit 2 MONTH MARCH - 1997 DATE 4/3/97 COMPLETED BY M. B. Koudeika
~ TELEPHONE 414-755-6480 AVERAGE AVERAGE.
AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET -
t 1
-2 11
-2 21 --
2 i
i 2
-2 12
-2 22
-2 3
-2 13
-2 23
-2 l
r 4
-2 14
-2 24
-2 5
-3 15. 25. -
-2
-2
. 26
-2 6
-2 16 7
-2 17
-2 27
-2
{
8
-2 18
-2 28
-2 9
-2 19
-2 29
-2 10-
-2 20
-1 30
-2 i
31
-2 i
t I
s...
~,...
~,,
^
' POINT BEACil NUCLEAR PLANT -
' Dociet No.
' 50-301 5.1
. Unit Name '.
Point bd Unit 3 11 NIT SHtTTDOWNS AND POWER REDUCTIONS Date
- 1 1 1997 Completed By i MJ B. Komiella ~
REPORT MONTH MARCil-1997.
? Telephone No.L 414/755 4480;
~
Medmat of
- Causs an! Correaive Acam Namm =
Shurung licmce Event.
System Campmern
~
. No. '
' Dese Type' illours)'
Reaum
h Retmut No-Cdde* ~
cause$
._To Prevers Recurrerm;e s
w...)
-O
' %t005
.S 744 C-1-
NA NA' NA Sheduled refuelu1g anl nummerunce outage t02R22). Mayw work mens ashale.. Replacmg hda :
Iteus 2 sacant generators; mam corart4 tuard wwe separatum remlutaut; regiace 8 mato sacam -
cammlemer *alves; ilP autana crtasunkt pering; repan service mater mest heakt; regdace tssw acal amt rescaw niakeup water amahrers; replace safety upm aAumulakw level transnuners; nu.nlify -.
X412. X 03 armi Xo4 tramformer menenng armi relay cin;uas; ant due encaer nadfica:mmi,.-
F: ' Forced
' ' Reason:
'Metinl:
' ' Exhibit (;. Instructions S: Scheduled
' A - Equipment Failure (explain) 1 - Manual '
for preparation of B - Maintenance or Testing 2 - Manual Scram dat.. en.ry sheets.
C - Refueling 3 - Automatic Scram LFR Tale (NUREG-0161)
D - Regulatory Restriction 4 - Continuation of.
E - Operator Training &
Previous Shutdown Licensing Exam 5 - Reduced lead F - Administrative 6 - Other (explain)
? Exhibit 1 - Same Source G - Operational Error (explain) 11 - Other (explain)
PBF4128b 103-90)
i
. DOCKET NO.
50 301
' UN'If NAME Point Beach Unit 2 DATE 04/03/97 COMPLETED BY M. B. Koudelka TELEPHONE 414/755-6480 Unit 2 was in a refueling outage during the entire March.1997 report period.
Safety-related maintenance included:
1.
2P-15 A-M safety injection pump motor alignment tab weld repaired.
L2.L 2P-15BB safety injection pump control switch replaced.
3.
2VNPSE-3213 W-6A&B U2C purge exhaust fan suction valve replaced and T-litting repaired.
a r
-