Dave Mor;y S:uthern Nucleat Vice Presdent Operating Company farley Project P.0 Box 1295 Birmingham. Alabama 35201 Tel 205992 5131 April 1,

1997 SOUTHERN COMPANY Energy to Serve YourWorld

10 CFR 50.90 Docket Numbers:

50-348 50-364 U. S. Nuclear Regulatory Commission ATrN: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant Clarification Of Request For Technical Specification Changes Elimination of Containment Sorav Additive System Ladies and Gentlemen:

In a November 15,1996 letter to the NRC, Southern Nuclear Operating Company (SNC) proposed to amend the Farley Nuclear Plant (FNP) Unit I and Unit 2 Technical Specifications, Appendix A to Operating Licenses NPF-2 and NPF-8. He amendment would result in the deletion of containment systems specification 3.6.2.2," Spray Additive System."

In the SNC November 15,1996 letter to the NRC, the last paragraph on page El-2 of the Safety Arsessment states the following:

He components associated with the spray additive system are being either spared in place or removed. He blind flanges installed in the eductor lines will meet ASME Section Ill Class 3 requirements. He contaimnent spray piping wih continue to meet the plant seismic and ASME Section 111 Class 3 requirements.

This infonnation is also included in the fourth paragraph on page 2 of the NRC's Safety Evaluation provided in the NRC February 3,1997 letter to SNC.

\\

The paragraph should have stated that the blind flanges and containment spray system piping will ij meet ASME Section 111 Class 2 requirements vice meeting ASME Section III Class 3 requirements. The fact that the blind flanges at FNP are being installed in ASME Section Class 2 containm.: ;,.my piping and not Class 3 piping was not recognized in the preparation of the FNP kg NRC submittal. The Enclosure provides a drawing that shows the location of the blind flanges being installed.

9704000259 970401 PDR ADOCK 05000348 p

PDR

.I.5,4

'. S. Nuclear Regulatory Commission Page 2 U

.'Ihe following items provided in the SNC November 15,1996 letter to the NRC remam valid: (1) the safety assessment for the proposed changes (except for the ASME Section III Class 2 vice ASME Section III Class 3 issue as changed by this letter), (2) the basis for a determination that the proposed changes do not involve a significant hazards consideration pursuant to 10 CFR 50.92, (3) the proposed changes to the Unit I and Unit 2 Technical Specifications pages, and (4) the

' determination that the proposed changes will not significantly affect the quality of the human environment. A copy of this letter has been sent to Dr. D. E. Williams, the Alabama State Designee, in accordance with 10 CFR 50.91(b)(i).

Mr. D. N. Morey states that he is a vice president of Southem Nuclear Operating Company, and is authorized to execute this oath on behalf of Southern Nuclear Operating Company and that, to the best of his knowledge and belief, the facts set forth in this letter and enclosures are true.

Respectfully submitted, SOUTHERN NUCLEAR OPERATINO COMPANY

$N }729 Dave Morey M

THIS / ' DAY OF M

,1997 kJ&

haubt Notary Pudic l

MY COMMISSION EXPIRES:

M / 9f 7 DRC: mar _ sat-tsp 3. doc i

Enclosure:

Proposed Drawing Of Cutting And Capping In Class 2 Piping l

cc:

Mr. L. A. Reyes, Region 11 Administrator Mr. J. I. Zimmerman, NRR Licensing Project Manager Mr. T. M. Ross, FNP Senior Resident Inspector Dr. D. E. Williamson, State Department of Public Health i

f

0-

{

k e

4 ENCLOSURE PROPOSED DRAWING OF CUTTING AND CAPPING IN CLASS 2 PIPING i

i 1

DCP Corksheet Farley Niiclear I'latit w.e n to w

  • ~ ' ' * * *

'*~

RtB E.P. DAVIDSON 95-8931 -M004 A

o-oso38 sw.3 is PROPOSED Ac^oovv 893 moo 4

. : Proposal"B" Containment Spray P&ID (DCP 95-1 931)

.v

. woe L"T tH

.1r 3Tuse ri.ca se f

. 6_p[> D I"'s ***

'J:'tErrg- --,j-,,,f-r co d..a sma1 ww p-----

nate s.

/

g...

,,m w" q

/

g g N g*s--.8 u esre az

.204 m

.,t Q q ; L. _,.t p&

W,s i

s

=

m 7.-

~...

n 6 h D.,

u,I 38-

  • ll***

+

.m..P. ' ad..

  • "a V.pL.

=_===a-1

, < -. ~

g

  • "a

(

=}

i.s =,

j

  • * * * =.

-s t.

n A

WY l

j\\*

}a O

Q=

r m c..

e c, i N g*

.%._ s _

}

co c.co e.

s

.w 113 0

=

I,.

a 1; f

s*-

-W_..

' "** /.

J.

I

n. ;,[.T,xe n
v.,%.1

=== [,4 **

.m.%..%.

c

=

e.==e.

,M*/,2 k

t' as%- - - ','

i d

[53r-J

^

i m

k

, we a

m. = =. _=.w.-a at*a r==s m

M

! ; ;;==,-,

r w=.

a

._. gse gs v.2 _

.s

=

oy n 'mo======m es*== $_==.,)

a i

t M.,

. M*,7 l

'm".L 3

o*#

    • Ye'
  • d*w' *

~4(g.'*;.".;;E W ".E:n g

.pt y

Q b

mo o

.oa

.m....--~0.<.c.

j b en-maeoe ses b

.LOLtvcw srutA.asLcise. wen 6va 4.ro.

a m.s u' y g

9 m.,vw..t.ELT L.Ow, Wit'peiste =ie. =.. -

t gs %

t.,

/.

N,

  • r cs sa

= =am k-rat se _

a e t *tweceaev sen

.me ais AA.cet r

g tg -

.He S.800.% pe.4 4,DL.e.ee, meTs t.

m r.c <u

-a,,_,g_j 4 't w.

o- =*.c.s v=m t.

A

. **.angT

"**"******O*C*E i

ggy F'L g* AR T-us.

s f ta g?

?*LL AT h.e AC.L EM 96 A=uD g

CConwa vipE sisT LOC aiT*C'*e SW 2"*/

- I i 9tf Suet m"M Gtes tt eau - e = e t.e L s e.a p;;;f.u==*g,

'./.ga' %,, 9 g-

- ~.3 x

0

-m m

+

mm.

m