Docket Nos.: 50-369/370 DISTRIBUTION and 50-413/414 JAN 131986

centraleF11e ~ _

2 SSPD Rea' ding ^

EMcPeek BYoungblood JGibson Mr. H. B. Tucker, Vice President KJabbour PNoonan Nuclear Production Department DHood CGaskins, NMSS Duke Power Company MDuncan KBarr, RII 422 South Church Street HBerkow CPerny, RII Charlotte, North Carolina 28242 DTondi

Dear Mr. Tucker:

SUBJECT:

CATAWBA NUCLEAR STATION AND MCGUIRE NUCLEAR STATION -

PROTECTION OF AUXILIARY FEEDWATER PIPING This is in response to your letters of September 9,1985 which submitted 10 CFR 50.54(p) changes to the Physical Security Plans for the Catawba and McGuire Nuclear Stations. Since these changes involved the protection of vital equipment, the USNRC Region II Office referred the action to us for response.

Deleting an item of safety related equipment from the list of equipment protected as vital would decrease the effectiveness of your security plan and, accordingly, is not considered to be an appropriate change under the provisions of 10 CFR 50.54(p). Therefore, the September 9, 1985 modifications to your physical security plans for the McGuire and Catawba Nuclear Stations regarding auxiliary feedwater piping are not acceptable.

If you wish, you may submit application for amendments under the provisions of 10 CFR 50.90 for further review and analysis.

In the interim, you must revert back to the previously approved versions of your physical security plans.

We note that your changes also included Catawba Nuclear Station Unit 2.

The plan for this plant will also have to be modified until this matter is resolved.

Sincerely, ORIGIUll Slg3spIW s B. J. Youngblood, Director PWR Project Directorate #4 Division of PWR Licensing-A cc:

See next page f

L-B SSPD:DP SSP SSPD:DPL-B SSPJD

-B i

JGibson EM DTondi M HBdrh 01/p/86 01//[/86(

01/

86,g 01/3/f6 01/%/86 PWGypDPL-A Wh4:DPL-A PWR#4;d A

BJYo@un PWR

-A HDuncan DHood KJabbour g ood Gi/T/86 01/g /86 01/j/86 01/p/6 8601230418 860113 PDR ADOCK 05000369 F

pop

9

~?g UNITED STATES

[

g NUCLEAR REGULATORY COMMISSION

j WASHINGTON, D. C. 20555

%,..../

Docket Nos.: 50-369/370 JAN 131986 and 50-413/414 Mr. H. B. Tucker, Vice President Nuclear Production Department Duke Power Company 422 South Church Street Charlotte, North Carolina 28242

Dear Mr. Tucker:

SUBJECT:

CATAWBA NUCLEAR STATION AND MCGUIRE NUCLEAR STATION -

PROTECTION OF AUXILIARY FEEDWATER PIPING This is in response to your letters of September 9,1985 which submitted 10 CFR 50.54(p) changes to the Physical Security Plans for the Catawba and McGuire Nuclear Stations. Since these changes involved the protection of vital equipment, the USNRC Region II Office referred the action to us for response.

Deleting an item of safety related equipment from the list of equipment protected as vital would decrease the effectiveness of your security plan and, accordingly, is not considered to be an appropriate change under the provisions of 10 CFR 50.54(p). Therefore, the September 9, 1985 modifications to your physical security plans for the McGuire and Catawba Nuclear Stations regarding auxiliary feedwater piping are not acceptable.

If you wish, you may submit application for amendments under the provisions of 10 CFR 50.90 for further review and analysis.

In the interim, you must revert back to the previously approved versions of your physical security plans.

We note that your changes also included Catawba Nuclear Station Unit 2.

The plan for this plant will also have to be modified until this matter is resolved.

Sincerely,

/N11[

Lg s

3. J.

oungbl od, Director i

P Pr ject Directorate #4 Division of PWR Licensing-A cc: See next page i.

7 1

i e-

_-..--__y._

JAN 131986 Mr. H. B. Tucker Duke Power Company Catawba Nuclear Station cc:

William L. Porter, Esq.

North Carolina Electric Membership Duke Power Company Corp.

P.O. Box 33189 3333 North Boulevard Charlotte, North Carolina 28242 P.O. Box 27306 Raleigh, North Carolina 27611 J. Michael McGarry, III, Esq.

Bi: hop Liberman, Cook, Purcell Saluda River Electric Cooperative, and Reynolds Inc.

1200 Seventeenth Street, N.W.

P.O. Box 929 Washington, D. C.

20036 Laurens, South Carolina 29360 North Carolina MPA-1 Senior Resident Inspector Suite 600 Route 2, Box 179N 3100 Smoketree Ct.

York, South Carolina 29745 P.O. Box 29513 Raleigh, North Carolina 27626-0513 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, Mr. C. D. Markham 101 Marietta Street, NW, Suite 2900 Power Systems Division Atlanta, Georgia 30323 Westinghouse Electric Corp.

P.O. Box 355 Pittsburgh, Pennsylvania 15230 Robert Guild, Esq.

2759 Rosewood Drive NUS Corporation Columbia, South Carolina 29205 2536 Countryside Boulevard Clearwater, Florida 33515 Palmetto Alliance 2759 Rosewood Drive Mr. Jesse L. Riley, President Columbia, South Carolina 29205 Carolina Environmental Study Group 854 Henley Place Karen E. Long Charlotte, North Carolina 28208 Assistant Attorney General N.C. Department of Justice Richard P. Wilson, Esq.

P.O. Box 629 Assistant Attorney General Raleigh, North Carolina 27602 S.C. Attorney General's Office P.O. Box 11549 Spence Perry, Esquire Columbia, South Carolina 29211 Associate General Counsel Federal Emergency Management Agency Piedmont Municipal Power Agency Room 840 100 Memorial Drive 500 C Street Greer, South Carolina 29651 Washington, D. C.

20472 Mark S. Calvert, Esq.

Mr. Michael Hirsch Bishop, Liberman, Cook, Federal Emergency Man 4gement Agency Purcell & Reynolds Office of the General Counsel 1200 17th Street, N.W.

Room 840 Washington, D. C.

20036 500 C Street, S.W.

Washington, D. C.

20472 Brian P. Cassidy, Regional Counsel Federal Emergency Management Agency, Region I J. W. McCormach P0CH Boston, Massachusetts 02109

JAN 131996 Mr. H. B. Tucker Duke Power Company McGuire Nuclear Station cc:

Mr. A. Carr Dr. John M. Barry Duke Power Company Department of Environmental Health P. O. Box 33189 Mecklenburg County 422 South Church Street 1200 Blythe Boulevard Charlotte, North Carolina 28242 Charlotte, North Carolina 28203 Mr. F. J. Twogood County Manager of Mecklenburg County Power Systems Division 720 East Fourth Street Westinghouse Electric Corp.

Charlotte, North Carolina 28202 P. O. Box 355 Pittsburgh, Pennsylvania 15230 Chairman, North Carolina Utilities Commission Mr. Robert Gill Dobbs Building Duke Power Company 430 North Salisbury Street Nuclear Production Department Raleigh, North Carolina 27602 P. O. Box 33189 Charlotte, North Carolina 28242 Mr. Dayne H. Brown, Chief Radiation Protection Branch J. Michael McGarry, III, Esq.

Division of Facility Services Bishop, Liberman, Cook, Purcell Department of Human Resources and Reynolds P.O. Box 12200 1200 Seventeenth Street, N.W.

Raleigh, North Carolina 27605 Washington, D. C.

20036 Senior Resident Inspector c/o U.S. Nuclear Regulatory Commission Route 4, Box 529 Hunterville, North Carolina 28078 Regional Administrator, Region II U.S. Nuclear Regulatory Commission, 101 Marietta Street, N.W., Suite 2900 Atlanta, Georgia 30323 L. L. Williams Operating Plants Projects Regional Manager Westinghouse Electric Corporation - R&D 701 P. O. Box 2728 Pittsburgh, Pennsylvania 15230 N

JAN 131986 Catawba (amendments) cc:

Mr. Heyward G. Shealy, Chief Bureau of Radiological Health South Carolina Department of Health and Environmental Control 2600 Bull Street Columbia, South Carolina 29201 County Manager of York County York County Courthouse York, South Carolina 29745 Attorney General P.O. Box 11549 Columbia, South Carolina 29211 I

I l

2

.rm.-,

-.m.. _-. _ _ - _,.,

_ -. -. - -.