| | | Reporting criterion |
|---|
| 05000315/LER-1985-001, :on 850105,fire Watch Failed to Conduct 2330 Hourly Insp of Inoperable Fire Barrier Penetration Seals & Dampers in Unit 1 & 2 Charging Pump Rooms.Caused by Inadequate Turnover of Tour Assignments |
- on 850105,fire Watch Failed to Conduct 2330 Hourly Insp of Inoperable Fire Barrier Penetration Seals & Dampers in Unit 1 & 2 Charging Pump Rooms.Caused by Inadequate Turnover of Tour Assignments
| |
| 05000316/LER-1985-001-01, :on 850111,automatic ESF Actuation Occurred, Providing Start Signal to Motor Driven Auxiliary Feedwater Pumps.Caused by Personnel Error in Manual Control of Feedwater Regulator Valves |
- on 850111,automatic ESF Actuation Occurred, Providing Start Signal to Motor Driven Auxiliary Feedwater Pumps.Caused by Personnel Error in Manual Control of Feedwater Regulator Valves
| |
| 05000316/LER-1985-002, :on 850112,automatic ESF Actuation Occurred, Resulting in Reactor Trip.Caused by lo-lo Level in Steam Generator 22 Due to Unexpected Increase in Steam Flow.Event Discussed W/Shift Personnel & Operating Memo Written |
- on 850112,automatic ESF Actuation Occurred, Resulting in Reactor Trip.Caused by lo-lo Level in Steam Generator 22 Due to Unexpected Increase in Steam Flow.Event Discussed W/Shift Personnel & Operating Memo Written
| |
| 05000315/LER-1985-002-01, :on 850118,discovered That Required Daily Auxiliary Bldg Vent Sample Not Taken on 850111-17.Required Daily Samples Collected on 850118 & 19.Surveillance Requirement Added & Procedures Revised |
- on 850118,discovered That Required Daily Auxiliary Bldg Vent Sample Not Taken on 850111-17.Required Daily Samples Collected on 850118 & 19.Surveillance Requirement Added & Procedures Revised
| |
| 05000315/LER-1985-003, :on 840116,Train a Battery Not Declared Inoperable Per Tech Spec 4.8.2.4.2.Caused by Misunderstanding Between Personnel.Requirement Will Be Added to Surveillance Procedure |
- on 840116,Train a Battery Not Declared Inoperable Per Tech Spec 4.8.2.4.2.Caused by Misunderstanding Between Personnel.Requirement Will Be Added to Surveillance Procedure
| |
| 05000316/LER-1985-003, :on 850126,while in Mode 1,reactor Tripped. Caused by Failure of Vital Bus III Inverter.Inverter Repaired.Accelerated Testing Program Implemented |
- on 850126,while in Mode 1,reactor Tripped. Caused by Failure of Vital Bus III Inverter.Inverter Repaired.Accelerated Testing Program Implemented
| |
| 05000316/LER-1985-004-01, :on 850125,RCS Loop 2 Cold Leg Temp Found Not Environmentally Qualified.On 850126,unit Trip Occurred. Caused by Unrelated Component Failure.Loop Replaced W/Qualified Spare |
- on 850125,RCS Loop 2 Cold Leg Temp Found Not Environmentally Qualified.On 850126,unit Trip Occurred. Caused by Unrelated Component Failure.Loop Replaced W/Qualified Spare
| |
| 05000315/LER-1985-004, :on 850129,w/reactor in Mode 1,high Alarm Received on Lower Containment Radiation Monitor That Resulted in Containment Isolation.Caused by Upward Trend in Containment Airborne Activity |
- on 850129,w/reactor in Mode 1,high Alarm Received on Lower Containment Radiation Monitor That Resulted in Containment Isolation.Caused by Upward Trend in Containment Airborne Activity
| |
| 05000316/LER-1985-005, :on 850130,one Cell on Train AB Battery Had Unacceptable Specific Gravity Reading.Cell Replacement Completed & Cross Tie Breaker Opened Restoring Both Dc Bus Trains |
- on 850130,one Cell on Train AB Battery Had Unacceptable Specific Gravity Reading.Cell Replacement Completed & Cross Tie Breaker Opened Restoring Both Dc Bus Trains
| |
| 05000315/LER-1985-005-01, :on 850205,discovered That Sample Medium Designated in Tech Spec 3.11.2.1 Not Used.Caused by Personnel Error.Tech Spec Change Re Use of Iodine Will Be Implemented |
- on 850205,discovered That Sample Medium Designated in Tech Spec 3.11.2.1 Not Used.Caused by Personnel Error.Tech Spec Change Re Use of Iodine Will Be Implemented
| |
| 05000316/LER-1985-006-01, :on 850204,8-inch by 16-inch Opening Found in Wall in Quadrant 1 of Reactor Cable Tunnel,Constituting Inoperable Fire Barrier.Opening Believed to Have Existed Since Initial Plant Const.Opening Repaired |
- on 850204,8-inch by 16-inch Opening Found in Wall in Quadrant 1 of Reactor Cable Tunnel,Constituting Inoperable Fire Barrier.Opening Believed to Have Existed Since Initial Plant Const.Opening Repaired
| |
| 05000315/LER-1985-006, :on 850206,auxiliary Bldg Access Control Ventilation Duct Fire Damper Found Closed.Damper Designed as safety-related But Misidentified as nonsafety-related.Damper Reset |
- on 850206,auxiliary Bldg Access Control Ventilation Duct Fire Damper Found Closed.Damper Designed as safety-related But Misidentified as nonsafety-related.Damper Reset
| |
| 05000316/LER-1985-007, :on 841228,NDE Revealed Cracks in Seven 2-inch Rockwell-Edward Globe Valves,Similar to IE Info Notice 84-48 & Suppl 1 Description.Valves Isolate Reactor Coolant Loop Resistance Temp Detector Manifolds |
- on 841228,NDE Revealed Cracks in Seven 2-inch Rockwell-Edward Globe Valves,Similar to IE Info Notice 84-48 & Suppl 1 Description.Valves Isolate Reactor Coolant Loop Resistance Temp Detector Manifolds
| |
| 05000315/LER-1985-007-01, :on 850222,controlled Shutdown Initiated. Caused by Inoperable Control Room Emergency Ventilation Sys. Analysis of Potential Radiological Consequences of Operation at Higher Flow Rates Performed.Room Balanced |
- on 850222,controlled Shutdown Initiated. Caused by Inoperable Control Room Emergency Ventilation Sys. Analysis of Potential Radiological Consequences of Operation at Higher Flow Rates Performed.Room Balanced
| |
| 05000315/LER-1985-007, :on 850222,control Room Pressure Could Not Be Maintained at +1/+6 Inches Wg Relative to Outside Atmosphere.Flow Rates Satisfactorily Adjusted & Unit Returned to Power.Mods Being Developed |
- on 850222,control Room Pressure Could Not Be Maintained at +1/+6 Inches Wg Relative to Outside Atmosphere.Flow Rates Satisfactorily Adjusted & Unit Returned to Power.Mods Being Developed
| |
| 05000316/LER-1985-008, :on 850103,broken Control Rod Guide Tube Support Pins Found in Steam Generators 22 & 23.Failure of Pin in Generator 22 Attributed to Igscc.Cause of Pin Failure in Generator 23 Undetermined |
- on 850103,broken Control Rod Guide Tube Support Pins Found in Steam Generators 22 & 23.Failure of Pin in Generator 22 Attributed to Igscc.Cause of Pin Failure in Generator 23 Undetermined
| |
| 05000315/LER-1985-008-01, :on 850314,low Pressure Carbon Dioxide Fire Suppression Sys Removed from Svc W/O Proper Fire Watch Coverage.Caused by Nonlicensed Planning Personnel Error. Individuals Counseled |
- on 850314,low Pressure Carbon Dioxide Fire Suppression Sys Removed from Svc W/O Proper Fire Watch Coverage.Caused by Nonlicensed Planning Personnel Error. Individuals Counseled
| |
| 05000316/LER-1985-009, :on 850327,monthly Vent Stack Composite Sample Lost During Isotopic Extraction Procedure.Caused by Error in Lab Technician Handling Technique.Personnel Counseled Re Handling Breakable Equipment |
- on 850327,monthly Vent Stack Composite Sample Lost During Isotopic Extraction Procedure.Caused by Error in Lab Technician Handling Technique.Personnel Counseled Re Handling Breakable Equipment
| |
| 05000315/LER-1985-010, :on 850112 & 0406,dose Equivalent I-131 Limit Exceeded.Fuel Sipping Performed During 10-yr Inservice Insp/Refueling Outage on 208 Fuel Assemblies |
- on 850112 & 0406,dose Equivalent I-131 Limit Exceeded.Fuel Sipping Performed During 10-yr Inservice Insp/Refueling Outage on 208 Fuel Assemblies
| |
| 05000316/LER-1985-010, :on 850327,fire Watch Failed to Inspect 4 Kv Bus Room Ab.Caused by Personnel Error.Fire Watch Reinstructed Re Responsibility to Enter All Areas Assigned as Part of Fire Duties |
- on 850327,fire Watch Failed to Inspect 4 Kv Bus Room Ab.Caused by Personnel Error.Fire Watch Reinstructed Re Responsibility to Enter All Areas Assigned as Part of Fire Duties
| |
| 05000315/LER-1985-010-01, :on 850112 & 0406,dose Equivalent I-131 of Reactor Coolant Exceeded Tech Spec Limit.Caused by Leaking Fuel Assemblies.Fuel Sipping Will Be Performed During 1985 Refueling Outage |
- on 850112 & 0406,dose Equivalent I-131 of Reactor Coolant Exceeded Tech Spec Limit.Caused by Leaking Fuel Assemblies.Fuel Sipping Will Be Performed During 1985 Refueling Outage
| |
| 05000315/LER-1985-011, :on 850407,containment Purge Begun Per Approved Procedure Which Established More than on Purge Supply & Exhaust Path.Procedure Not Allowed Per Tech Spec 3.6.1.7. Procedures Changed |
- on 850407,containment Purge Begun Per Approved Procedure Which Established More than on Purge Supply & Exhaust Path.Procedure Not Allowed Per Tech Spec 3.6.1.7. Procedures Changed
| |
| 05000316/LER-1985-011-01, :on 850520,alarm Signals Received on Three Lower Containment Area Radiation Monitors Resulting in Containment Purge/Exhaust Isolation Signal |
- on 850520,alarm Signals Received on Three Lower Containment Area Radiation Monitors Resulting in Containment Purge/Exhaust Isolation Signal
| |
| 05000316/LER-1985-012, :on 850603,while Process Radiation Monitoring Instrumentation Inoperable,Auxiliary Bldg Ventilation Grab Sample Not Obtained within Specified Time Restraints.Caused by Personnel Error.Technicians Counseled |
- on 850603,while Process Radiation Monitoring Instrumentation Inoperable,Auxiliary Bldg Ventilation Grab Sample Not Obtained within Specified Time Restraints.Caused by Personnel Error.Technicians Counseled
| |
| 05000316/LER-1985-013, :on 850726,frost Accumulation in Excess of Tech Spec Found within Ice Condenser Flow Passages.Caused by Excessive Moisture in Air or Sublimation of Ice.Frost Buildup Removed on 850728 |
- on 850726,frost Accumulation in Excess of Tech Spec Found within Ice Condenser Flow Passages.Caused by Excessive Moisture in Air or Sublimation of Ice.Frost Buildup Removed on 850728
| |
| 05000315/LER-1985-013, :on 850407,w/RCS in Mode 3,spray Additive Tank Room Fire Door 529 Found Blocked Open W/O Fire Watch Coverage.Caused by Personnel Error.Blockage Removed |
- on 850407,w/RCS in Mode 3,spray Additive Tank Room Fire Door 529 Found Blocked Open W/O Fire Watch Coverage.Caused by Personnel Error.Blockage Removed
| |
| 05000316/LER-1985-013-01, :on 850726,accumulation of Excessive Frost within Ice Condenser Flow Passages Discovered.Condition May Have Existed Prior to Cold Shutdown.Frost Buildup Removed on 850728.Investigation Underway |
- on 850726,accumulation of Excessive Frost within Ice Condenser Flow Passages Discovered.Condition May Have Existed Prior to Cold Shutdown.Frost Buildup Removed on 850728.Investigation Underway
| |
| 05000316/LER-1985-014, :on 850728,w/unit in Mode 5,inadvertent Safety Injection Signal Generated During Installation of Design Change.Caused by Voltage Drop Resulting in Reduction of Power to Vital Instrument Buses III & IV |
- on 850728,w/unit in Mode 5,inadvertent Safety Injection Signal Generated During Installation of Design Change.Caused by Voltage Drop Resulting in Reduction of Power to Vital Instrument Buses III & IV
| |
| 05000315/LER-1985-014, :on 850407,fire Watch Unable to Conduct Insps of Seismic Gap Fire Barrier Seals.Caused by Broken Locking Mechanism on Fire Door 325 |
- on 850407,fire Watch Unable to Conduct Insps of Seismic Gap Fire Barrier Seals.Caused by Broken Locking Mechanism on Fire Door 325
| |
| 05000316/LER-1985-014-01, :on 850728,during Replacement of Inverters, Safety Injection Signal Inadvertently Generated.Caused by Reactor Coolant Pump 3 Startup,Resulting in Momentary Power Reduction from Channels 3 & 4 |
- on 850728,during Replacement of Inverters, Safety Injection Signal Inadvertently Generated.Caused by Reactor Coolant Pump 3 Startup,Resulting in Momentary Power Reduction from Channels 3 & 4
| |
| 05000315/LER-1985-015, :on 850408,09 & 11,several Spurious High Alarms Received on Lower Containment Radiation Monitor Particulate Channels Ers 1301 & Ers 1401.Caused by Jump in Rate Count. New Program Chips Purchased |
- on 850408,09 & 11,several Spurious High Alarms Received on Lower Containment Radiation Monitor Particulate Channels Ers 1301 & Ers 1401.Caused by Jump in Rate Count. New Program Chips Purchased
| |
| 05000316/LER-1985-015-01, :on 850803,ESF Actuation Occurred.Caused by Level Deviation Due to Excessive Leakage Through Loop 4 Auxiliary Feedwater Valve.Loop 4 Removed from Svc & Will Be Repaired Prior to Startup |
- on 850803,ESF Actuation Occurred.Caused by Level Deviation Due to Excessive Leakage Through Loop 4 Auxiliary Feedwater Valve.Loop 4 Removed from Svc & Will Be Repaired Prior to Startup
| |
| 05000315/LER-1985-016, :on 850412,w/RCS in Mode 3,vent Inside Containment Opened to Drain Header & Vent Outside Containment Opened to Drain Hxs,Creating Flow Path from Inside to Outside Containment.Procedure Revised |
- on 850412,w/RCS in Mode 3,vent Inside Containment Opened to Drain Header & Vent Outside Containment Opened to Drain Hxs,Creating Flow Path from Inside to Outside Containment.Procedure Revised
| |
| 05000316/LER-1985-016-01, :on 850808,flux Mapping Sys (Fms) Frame Assembly Restraint Devices Not Installed Per Design Specs. Installation of Restraint Devices & Mods Authorized by Design Changes (RFC-12-2778) Completed 850817 |
- on 850808,flux Mapping Sys (Fms) Frame Assembly Restraint Devices Not Installed Per Design Specs. Installation of Restraint Devices & Mods Authorized by Design Changes (RFC-12-2778) Completed 850817
| |
| 05000315/LER-1985-017, :on 850417,accumulated Leakage Exceeded Tech Spec Limits Found While Performing Type B & C Leak Rate Tests.Cause Unknown.Penetrations Repaired |
- on 850417,accumulated Leakage Exceeded Tech Spec Limits Found While Performing Type B & C Leak Rate Tests.Cause Unknown.Penetrations Repaired
| |
| 05000316/LER-1985-017-01, :on 850819 & 22,listed ESF Actuation Signals Received While Unit in Mode 3.Caused by Increasing Containment Radioactivity During Startup.Containment Purge Procedure Revised |
- on 850819 & 22,listed ESF Actuation Signals Received While Unit in Mode 3.Caused by Increasing Containment Radioactivity During Startup.Containment Purge Procedure Revised
| |
| 05000315/LER-1985-018, :on 850416,fire Barrier Inoperable.Caused by Lack of Fire Sealant Matl in Two Floor Penetrations. Penetrations Sealed,Declared Operable & Added to Surveillance Program |
- on 850416,fire Barrier Inoperable.Caused by Lack of Fire Sealant Matl in Two Floor Penetrations. Penetrations Sealed,Declared Operable & Added to Surveillance Program
| |
| 05000316/LER-1985-018-01, :on 850820,ESF Actuation Occurred.Caused by Opening of Reactor Trip Breakers During Instrumentation Checks.Surveillance Test Procedure Thp 4030 STP.180 Revised |
- on 850820,ESF Actuation Occurred.Caused by Opening of Reactor Trip Breakers During Instrumentation Checks.Surveillance Test Procedure Thp 4030 STP.180 Revised
| |
| 05000315/LER-1985-019, :on 850420,ice Inventory within Ice Condenser Determined to Be Below Tech Spec Limits.Cause Unknown.Ice Weight of Deficient Rows Increased by Ice Replenishment Program |
- on 850420,ice Inventory within Ice Condenser Determined to Be Below Tech Spec Limits.Cause Unknown.Ice Weight of Deficient Rows Increased by Ice Replenishment Program
| |
| 05000316/LER-1985-019-01, :on 850821,determined That Seismic Qualification of Governors for turbine-driven Auxiliary Feed Pumps Inadequate for Approx 4 Yrs.Cause Not Stated.Governors as Installed Meet Current Seismic Requirements |
- on 850821,determined That Seismic Qualification of Governors for turbine-driven Auxiliary Feed Pumps Inadequate for Approx 4 Yrs.Cause Not Stated.Governors as Installed Meet Current Seismic Requirements
| |
| 05000315/LER-1985-020, :on 850429,low Pressure CO2 Fire Suppression Sys for Quadrant 1 of Reactor Cable Tunnel Isolated W/O Fire Watch Coverage.Caused by Personnel Error.Personnel Counseled |
- on 850429,low Pressure CO2 Fire Suppression Sys for Quadrant 1 of Reactor Cable Tunnel Isolated W/O Fire Watch Coverage.Caused by Personnel Error.Personnel Counseled
| |
| 05000316/LER-1985-020, Advises That LER 85-020-00 Re Inoperable Fire Damper, Determined Not Reportable & Being Withdrawn.Concludes That All Specified Compensatory Actions Per Tech Specs Completed & Events Did Not Constitute Unreviewed Safety Issues | Advises That LER 85-020-00 Re Inoperable Fire Damper, Determined Not Reportable & Being Withdrawn.Concludes That All Specified Compensatory Actions Per Tech Specs Completed & Events Did Not Constitute Unreviewed Safety Issues | |
| 05000316/LER-1985-020-01, :on 850822,during Surveillance Testing, safety-related Fire Damper Found Inoperable.Cause Not Determined.Damper Repaired,Tested & Returned to Svc on 850823 |
- on 850822,during Surveillance Testing, safety-related Fire Damper Found Inoperable.Cause Not Determined.Damper Repaired,Tested & Returned to Svc on 850823
| |
| 05000315/LER-1985-021, :on 850429,reactor Vessel Flow Requirement Not Verified Prior to RCS Boron Dilution.Procedure for Filling Reactor Refueling Cavity Revised to Include Verification/ Documentation of Reactor Vessel Flow During RCS Dilution |
- on 850429,reactor Vessel Flow Requirement Not Verified Prior to RCS Boron Dilution.Procedure for Filling Reactor Refueling Cavity Revised to Include Verification/ Documentation of Reactor Vessel Flow During RCS Dilution
| |
| 05000316/LER-1985-021-01, :on 850822 & 23,discovered That Several Instrumentation Channel Functional Tests Not Performed as Required.Cause Not Stated.Testing Conducted |
- on 850822 & 23,discovered That Several Instrumentation Channel Functional Tests Not Performed as Required.Cause Not Stated.Testing Conducted
| |
| 05000315/LER-1985-022, :on 850502 & 04-07,during Refueling,High Alarms Received on Lower Containment Monitor Particulate Channels ERS-1301 & ERS-1401.Caused by Fluctuation Activity Resulting in Erroneous Alarms.Value Will Be Updated |
- on 850502 & 04-07,during Refueling,High Alarms Received on Lower Containment Monitor Particulate Channels ERS-1301 & ERS-1401.Caused by Fluctuation Activity Resulting in Erroneous Alarms.Value Will Be Updated
| |
| 05000316/LER-1985-022-01, :on 850825,grab Sample of Essential Svc Water Sys Not Obtained at Proper Time.Caused by Technician Error. Technician Disciplined |
- on 850825,grab Sample of Essential Svc Water Sys Not Obtained at Proper Time.Caused by Technician Error. Technician Disciplined
| |
| 05000315/LER-1985-023, :on 850502,definition of Auxiliary Bldg Crane Load Block as Being Heavy Load Not Emphasized in Plant Procedures.Cautions Will Be Added to Applicable Plant Procedures by 850615 |
- on 850502,definition of Auxiliary Bldg Crane Load Block as Being Heavy Load Not Emphasized in Plant Procedures.Cautions Will Be Added to Applicable Plant Procedures by 850615
| |
| 05000316/LER-1985-023-01, :on 850823,discovered That Incorrect Essential Svc Water Sample Point Being Used to Fulfill Table 3.3-12 of Tech Spec 3.3.3.9.Procedure 12 Thp 6020 LAB.037 Revised to List Specific Sample Points |
- on 850823,discovered That Incorrect Essential Svc Water Sample Point Being Used to Fulfill Table 3.3-12 of Tech Spec 3.3.3.9.Procedure 12 Thp 6020 LAB.037 Revised to List Specific Sample Points
| |
| 05000316/LER-1985-024-01, :on 850906,automatic ESF Actuation Occurred, Resulting in Reactor Trip Signal.Caused by Simultaneous Tripping of Two of Three Steam Generator 2 Level Channel Bistables.No Corrective Action Taken |
- on 850906,automatic ESF Actuation Occurred, Resulting in Reactor Trip Signal.Caused by Simultaneous Tripping of Two of Three Steam Generator 2 Level Channel Bistables.No Corrective Action Taken
| |