Forwards Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301 & Notice of Violation
Date released: 05/30/2020 Download: ML20137F667


Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering,Plant Support & Effectiveness of Licensee Controls in Identifying & Preventing Problems
ML20137F708
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 03/18/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20137F708 (35)
Notice of Violation from Insp on 970119-0301.Violations Noted:Alarm Response Procedure for 2A-A Emergency Diesel Generator Inadequate in Items Listed
ML20137F677
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 03/18/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
References
Download: ML20137F677 (2)
Forwards Insp Repts 50-327/97-01 & 50-328/97-01 on 970119-0301 & Notice of Violation
ML20137F663
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 03/18/1997
From: Lesser M
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: KINGSLEY O D
TENNESSEE VALLEY AUTHORITY
References
Download: ML20137F663 (5)