o

  • \\

f-

{

GPU Nucleer, Inc.

(

U.S. Route #9 South NUCLEAR Post Office Box 388 Forked River, NJ 087310388 Tel 609-9714300 March 24, 1997 6730-97-2085 REIRS Project Manager Office of Nuclear Regulatory Research U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docket No. 50-219 Annual Exposure Data Report for 1996 In accordance with 10 CFR 20.2206 and Paragraph 6.9.1.b of the Oyster Creek Nuclear Generating Station's Technical Specifications, attached is the Annual Exposure Data l

Report for 1996. Included in the report is a listing of the number of station, utility, and contractor personnel as well as a diskette reporting 1996 Occupational Radiation Exposure Form 5 data.

Ifyou should have any questions concerning this report, please do not hesitate to contact Ms. Brenda DeMerchant, Oyster Creek Regulatory Affairs Engineer at 609-971-4642.

Very truly yours, IN b

Michael B. Roche Vice President & Director j

Oyster Creek l

MBR/BDeM/gl Attachment y

cc:

NRC Document Control Desk p[

Administrator, Region I(2 copies)

(#

NRC Project Manager NRC Resident Inspector American Nuclear Insurers 9703280437 961231

~

DR ADOCK 05000219 c r 'on r.y,_.

llll]l[llglllgggg PDR v

_u.

b NUMBER OF PERSONNEL AND PERSON REMS BY WORK AND JOB FUNCTION (INTERNAL + EXTERNAL SRD)

OYSTER CREEK REPORT PERIOD - 01/01/96 TO 12/31/96 4

JOB CATEGORY STATION PERSONNEL UTILITY PERSONNEL CONTRACTOR PERSONNEL JOB FUNCTION NUMBER REMS NUMBER REMS NUMBER REMS REACTOR OPER 4 SURVitIL MAINTENANCE 134 4.009 2

.002 22 1.359 OPERATIONS 97 11.335 0

.000 1

.000 HEALTH PHYSICS 42 2.272 0

.000 1

.000 SUPERVISORY 14

.240 0

.000 0

.000 ENGINEERING 15

.089 0

.000 1

.096 OTHER 1

.249 0

.000 2

.003 ROUTINE MAINTENANCE MAINTENANCE 425 30.343 38 1.400 635 15.970 OPERATIONS 182 4.840 1

.000 12

.177 HEALTH PHYSICS 83 6.858 0

.000 57 2.733 SUPERVISORY 78 1.299

.055 18

.566 ENGINEERING 118 3.627 4

.005 16

.240 OTHER 15

.064 6

.004 16

.046 INSERVICE INSPECTION MAINTENANCE 43

.969 1

.024 196 4.272 OPERATIONS 15

.930 0

.000 3

.039 HEALTH PHYSICS 8

.072 0

.000 5

.083 SUPERVISORY 1

.003 0

.000 1

.002 ENGINEERING 8

.058 0

.000 1

.115 OTHER 0

.000 0

.000 2

.018 SPECIAL MAINTENANCE MAINTENANCE 239 61.908 33 3.655 910 300.~153 OPERATIONS 79 8.457 0

.000 9

2.696 HEALTH PHYSICS 60 9.571 0

.000 43 6.694 1

SUPERVISORY 21 2.534 2

.064 15 1.660 ENGINEERING 42 3.077 0

.000 13 2.593 OTHER 2

.090 0

.000 6

1.114 WASTE PROCESSING MAINTENANCE 65

.452 4

.013,

21

.477 OPERATIONS 37 1.227 0

.000 4

.634 HEALTH PHYSICS 22

.236 0

.000 6

.027 SUPERVISORY 5

.064 0

.000 0

.000 ENGINEERING 2

.405 0

.000 1

.001 OTHER 2

.019 0

.000 0

.000 t

REFUELING l

~

MAINTENANCE 26

.215 1

.003 74 3.065 OPERATIONS 35 1.424 0

.000 2

.024 l

HEALTH PHYSICS 9

.292 0

.000 6

.093 f

SUPERVISORY 1

.219 0

.000 3

.317 ENGINEERING 6

.041 0

.000 3

.086 L

OTHER 0

.000 0

.000 1

.013 I

i i

l l

Enclosed is a disk containing Oyster Creek's 1996 Exposure Data.

Specifics of this disk are as follows:

- File name: NRCOYC96. ZIP NRCOYC96.EXE (see

  • NOTE below)

- Date Created:

3/3/97

Contact:

Denise Paulson GPU Energy 610-375-5051

- Other:

Data originally created on the mainframe, downloaded to the PC, and then formatted into a ZIP file using PKZIP version 2.00.

  • NOTE:

If your version of PKZIP is not compatible with tha one used to created the above ZIP file, then the EXE file can be referenced as follows:

At the command prompt, enter the EXE file name and depress enter.

A new file, NRCOYC96.DAT will be created which can then be accessed for editing / browsing needs.

l l

l i

NUMBER OF PERSONNEL AND PERSON REMS BY WORK AND JOB FUNCTION (INTERNAL + EXTERNAL SRD)

OYSTER CREEK REPORT PERIOD - 01/01/96 TO 12/31/96 JOB CATEGORY STATION PERSONNEL UTILITY PERSONNEL' CONTRACTOR PERSONNED JOB FUNCTION NUMBER REMS NUMBER REMS NUMBER REMS TOTAL BY JOB FUNCTION

  • MAINTENANCE 458 97.896 39 5.097 1,025 325.896 OPERATIONS.

225 28.213 1

.000 15 3.570 HEALTH PHYSICS 87 19.301 0

.000 60 9.630 SUPERVISORY 81 4.359 4

.119 23 2.545 ENGINEERING 126 7.297 4

.005 20 3.131 OTHER 16

.422 6

.004 17 1.194

    • GRAND TOTAL **

993 157.488 54 5.225 1,160 345.966

-