4 123 Mrn Street
,g NWto P!ains, New York 10601 914 681.6240 e s
- > NewWrkPbwer r" tag:s.,
4# Authon.ty
~~c-e June 18, 1985 JPN-85-50 U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Thomas E. Murley Regional Administrator
Subject:
James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 NRC Bulletin 80-25 Operating Problems with Target Rock Safety Relief Valves
References:
1.
PASNY letter, R. J. Pasternak to B. H. Grier, dated March 19, 1981 (JAFP-81-0258).
2.
NUREG/CR-3794, "Closecut of IE Bulletin 80-25:
Operating Problems with Target Rock Safety-Relief Valves at Boiling Water Reactors," dated January, 1985.
Dear Sir:
As a result of several malfunctions of Target Rock safety relief valves, IE Bulletin 80-25 was issued for action to all operating Boiling Water Reactor facilities.
In Reference 1 the New York Power Authority responded to the Bulletin, and committed to modify the pneumatic supply system which actuates the safety relief valves.
Upon evaluation of utility responses and Nuclear Regulatory Commission inspection reports, Reference 2 was issued.
This document identified the Authority's commitment to modify the pneumatic supply as an open item.
However, this modification, which provides additional over pressure protection and high and low pressure alarms, was completed during the 1981 refueling and maintenance outage.
We consider that the completion of this modification closesBulletin 80-25 for the FitzPatrick plant.
8508260002 050618 gDR ADOCK 05000333 67 eDR p'-
y me l
1 l
l If you have any questions, please contact Mr. J. A. Gray, Jr.
of my staff.
Very truly yours.
h*'
4 W
John C. Brons Senior Vice President Nuclear Generation cc:
Office of the Resident Inspector U.S.
Nuclear Regulatory Commission P.O. Box 136 Lycoming, N.Y.
13093 Mr. Domenic B. Vassallo, Chief Operating Reactors Branch No. 2 Division of Licensing, USNRC Washington, D.C.
20555 l
I l
l l
!