Monthly Operating Rept for Dec 1985
ML20137D579
Person / Time
Site: Salem 
Issue date: 12/31/1985
From: White P, Zupko J
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
NUDOCS 8601170037
Download: ML20137D579 (9)


Text

. _ _ _ _ - _ _ _ _ _.

5 OPERATING DATA REPORT Docket No.50-272 Date January 10, 1986 Telephone 935-6000 Completed by Pell White Extension 4455 Operating Status 1.

Unit Name Salem No. 1 Notes 2.

Reporting Period December 1985 3.

Licensed Thermal Power (MWt) 3338 4.

Nameplate Rating (Gross MWe) 1170 5.

Design Electrical Rating (Net MWe) 1090 6.

Maximum Dependable Capacity (Gross MWe)1124 7.

Maximum Dependable Capacity (Net MWe) 1079 8.

If Changes Occur in Capacity Ratings (items 3 through 7) since Last Report, Give Reason N/A 9.

Power Level to Which Restricted, if any (Net MWe)

N/A

10. Reasons for Restrictions, if any N/A This Month Year to Date Cumulative
11. Hours in Reporting Period 744 8760 74569
12. No. of Hrs. Reactor was Critical 744 8361.9 44185.4
13. Reactor Reserve Shutdown Hrs.

0 0

3088.4

14. Hours Generator On-Line 744 8346.2 42504.8
15. Unit Reserve Shutdown Hours 0

0 0

16. Gross Thermal Energy Generated (MWH) 2468062 27716032 130484029
17. Gross Elec. Energy Generated (Mim) 827990 9379960 43296010
18. Net Elec. Energy Generated (MWH) 795915 9007510 41105492
19. Unit Service Factor 100 95.3 57.0
20. Unit Availability Factor 100 95.3 57.0
21. Unit Capacity Factor (using MDC Net) 99.1 95.3 51.1
22. Unit Capacity Factor (using DER Net) 98.1 94.3 50.6
23. Unit Forced Outage Rate 0.0-0.0 28.7
24. Shutdowns scheduled over next 6 months -(type, date and duration of each) o Refueling, March 20, 1986, approximately 60 days
25. If shutdown at end of Report Period, Estimated Date of Startup:

N/A

26. Units in Test Status (Prior _ to Commercial Operation) :

Forecast Achieved Initial Criticality 9/30/76 12/11/76 Initial Electricity 11/1/76 12/25/76 Commercial Operation.

12/20/76 6/30/77 8-1-7.R2 Page of S601170037 851231 g

ADOCM 05000272 M{%

pDR PDR

'g

~

- AVERAGE DAILY UNIT POWER LEVEL.

Docket No'.

'50-272' Unit Name Salem # 1 Date' January-10,1986-

~

Completed.by-Pell White

. Telephone 609-935-6000

' Extension. 4455 Month December 1985

" Day Average Daily Power Level Day Average Daily Power Level (MWe-NET)

(MWe-NET) 1 1073 17-1070 2

1083 18 1073-3 1092 19-1078 4

1079 '1048 5

1083 21 1075 6

1082 22 1085 7

1080 23 1109 8

1085 24.

-1077 9

1076 25 1074 r

10 1083 26 1067 11 1075 27 1073 12 1082 28

~1080 13 1077 29 1073' 14 1077 30-1081 15 1072 31 1078 16 826 P.

8.1-7 R1 4

~

P v

4 e -

y;-

,a-

,,-,m

UNIT SHUTDOWN AND POWER REDUCTIONS Dockst :No.5'0'-27 2

^

REPORT MONTH December 1985 Unit Name. Salem No.1 Date January-10,1986-

- Completed.by Pell White Telephone 609-935-6000 Extension 44 55-Method of Duration Shutting License Cause.and Corrective No.

Date

. Type Hours Reason Down Event System Component

. Action:tb 1

2 Rea cto r Report Code 4 Code 5 Prevent Recurrence' CJ INSTRU Pressurizer Pressure 750

'1216

F 1.2 A

5 Instrument & Controls-HC HTEXCH

. Loss of Vacuum /

752 1216

.F 1.7 A

5 High back Pressure.

HH INSTRU Feedwater Heater 780 1226 F

0.7 A

5 level control

1 2iReason 3 Method 4 Exhibit G 5 Exhibit li F:-Forced A-Equipment Failure-explain 1-Manual-Instructions Salem as

. S: Scheduled

B-Maintenance or Test 2-Manual Scram.

for Prepara-Source 3-Automatic. Scram.. tion.of Data

. C-Ref ueling <

4-Continuation off' Entry' Sheets D-Regulatory Restrictioni E-Operator TrainingL& Licensing' Exam Previous Outage for Licensee.

F-Administrative.

5-Load Reduction

. Event Report G-Operational Error-explain 9-Other (LER) File

-H-Other-explain

'(NUREG-0161)

L

A 4 ','

MAJOR-PLANT MODIFICATIONS DOCKET-NO.:

50-272-

. REPORT MONTH l DECEMBER:1985 UNIT.NAME:

Salem 1 DATE:- January 10, 1986

' COMPLETED BY:. J.-Ronafalvy TELEPHONE:

609/339-4455

  • DCR NO.

PRINCIPLE. SYSTEM SUBJECT-No major modifications completed this' month.

~

  • DCR
Design Change Request-4 i

t u

4 b

h L

i

?

I i

}-

i

.h L

b

.i

,l

4 PSEEG SALEM GENERATING. STATION

,j SAFETY RELATED WORK ORDER LOG SALEM UNIT 1

- o NO NO DEPT UNIT EQUIPMENT IDENTIFICATION

-8511290141 SMD.
1 ISJ69 AUX. TYPEWRITER PT.

G FAILURE DESCRIPTION:

AUX. TYPEWRITER "A 0623 RHRS SUCT ISOL. VA. ISJ69, OFF NORMAL POS."

WILL NOT. CLEAR.. VALVE HAS OPEN INDICATION ON CONSOLE AND OVERHEAD E10,1SJ69 OFF NORMAL,.IS NOT ILLUMINATED..

. CORRECTIVE ACTION:

HAD TO ADJUST LIMIT SWITCH STEM OF. VALVE HAD OPERATIONS.

l CYCLE VALVE TO VERIFY ALARM IS CLEAR.

8511290184-

.SMD 1

-VITAL HEAT TRACE _PT.

701

' FAILURE DESCRIPTION:

HEATER CONTROLLER PT. 701.#12 BA CONC.

CORRECTIVE ACTION:

HEAT TRACE BURNT UP.

REPLACED HEAT TAPE.

8511290192 JSMD-

-1

. VITAL HEAT TRACE PT. :702 HEATER CONTROLLER-PT.~702,'#11 BA CONC. PUMP IS NOT FAILURE DESCRIPTION:.. WORKING PROPERLY, PRIMARY.IS READING 6 227F..

iCORRECTIVE' ACTION:

-INSULATED HEAT TRACE 'lHERMOSTATS NOW READING :175 DEGREES F. PROBES ALSO IN WRONG POSITION s.

1 3

'. g '

s w.

SALEM UNIT 1 WO NO DEPT UNIT EQUIPMENT IDENTIFICATION 8512020539 SIC 1

11 CFCU SW FLOW FAILURE DESCRIPTION:

WHEN SERVICE WATER HEADER PRESSURE IS SLIGHTLY-HIGH, FAN COIL INDICATED FLOW GOES.OFF-SCALE HIGH AND WATER DRAIN FLOW DEVIATION ALARMS.

l CORRECTIVE ACTION:

FOUND INLET TRANSMITTER HIGH SIDE' INSTRUMENT LINE PLUG GED. BLEW DOWN LINES ON INLET & OUTLET TRANSMITTERS EQUALIZED & BLEWDOWN BOTH INLET & OUTLET. TRANSMITTERS WHEN DOING OUTLET WAS ABLE TO GET ZERO IN CONTROL ROOM 8512040114 SMD 1

16 SERVICE WATER PUMP FAILURE DESCRIPTION:

PLEASE REMOVE & INSPECT PUMP AS IT DOES NOT ACHIEVE ITS PROPER FLOW RATE.

CORRECTIVE ACTION:

PULLED PUMP, INSPECTED, BALANCED IMPELLER, REINSTALLED PUMP 8512050021 SMD 1

MAIN STEAM DRAIN VALVE FAILURE DESCRIPTION:

THE VALVE HAS A BODY TO BONNET LEAK.

CORRECTIVE ACTION:

REPLACED BONNET GASKET, REPACKED VALVE.

8512061405 SIC 1

150'FT. WIND SPEED FAILURE DESCRIPTION:

THE 150 FT. MET. TOWER WIND SPEED INDICATION IS FAILED IN THE CONTROL ROOM.

CORRECTIVE ACTION:

REPLACED ANAOMETER CUP ASSY

=_

A SALEM GENERATING STATION MONTHLY OPERATING

SUMMARY

. UNIT NO. 1-DECEMBER 1985 SALEM NO. 1 The Unit began-the period operating at full power.

On 12/16/85 power was reduced to 30% as a result of Pressurizer Spray Valve 1PS3 not fully reseating.

Following repairs to the valve positioner, full power was restored at 1320 hours0.0153 days <br />0.367 hours <br />0.00218 weeks <br />5.0226e-4 months <br /> the same day.

At 1805 hours0.0209 days <br />0.501 hours <br />0.00298 weeks <br />6.868025e-4 months <br /> on 12/16/85 power was reduced to 74% due to the loss of_all circulating-Water Screens when #14 Screen Wash Pump strainer housing failed spraying water onto the 480V distribution panel for the screens.

Full power was restored by 0208 hours0.00241 days <br />0.0578 hours <br />3.439153e-4 weeks <br />7.9144e-5 months <br /> on 12/17/85 where it remained for the rest of the period.

At 1445 hours0.0167 days <br />0.401 hours <br />0.00239 weeks <br />5.498225e-4 months <br /> on 12/13/85, No. 1 Unit surpassad the previous United' States record for annual gross generation by a nuclear unit.

The previous record of 8,892,300 MWhrs for a nuclear unit was established in 1979 by Peach Bottom Unit 2.

At 1630 hours0.0189 days <br />0.453 hours <br />0.0027 weeks <br />6.20215e-4 months <br /> on 12/16/85, No.

l' Unit surpassed the previous United States record for annual gross generation by any electric generating unit.

The previous record of 8,969,746 MWhrs for an electric generating unit was established in 1981 by the AEP Mountaineer Unit 1.

No. 1 Unit operated with an availability of 95.3% and a capacity factor (MDC) of 95.3% generating 9,379,960' (gross) MWhrs of energy during 1985.

~....

~

,~

REFUELING INFORMATION.

DOCKET-NO. :

50-272

. COMPLETED BY:-

J.

Ronafalvy-UNIT NAME:.. Salem 1 4

DATE:

January 10, 1986 TELEPHONE:

609/935-6000 EXTENSION:' 4455 Month December 1985 1.

Refueling information has changed from 'last month:

YES NO X

,1 4

2.

Scheduled date for next refueling:

March 22, 1986 3.

Scheduled date for restart following refueling: 'May 20, 1986-i 4.

A)-

Will Technical Specification changes or other license amendments be required?

YES NO

- l NOT DETERMINED TO DATE B)

Has the reload fuel design been reviewed by the Station Operating Review Committee?

YES NO X-l If no, when is it scheduled?.' February 1986

}

5.

Scheduled date(s) for submitting proposed licensing action:

February 1986 if required 6.

Important licensing considerations associated with refueling:

NONE 1

l 7.

Number of Fuel Assemblies:

A)

Incore 193' l

{.

B)

In Spent Fuel Storage 296 8.

Present licensed spent fuel storage capacity:

1170' l

Future spent. fuel storage capacity:

~1170 9.

Date of last refuelingL that can :be discharged to-spent fuel pool assuming the present I

licensed capacity:

September 2001 8-1-7.R4.

t t

r i

4

}

~

f

,, ~...

,..,..m,.

.__, -.~,

v.

.yo psgc Public Service Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station January 10,.1986 Director, Office of'. Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington,-DC-20555

Dear Sir:

' MONTHLY OPERATING REPORT S ALEM NO. 1.

DOCKET NO. 50-272 In-compliance with Section 6.9, Reporting Requirements-for the. Salem Technical Specifications, 10 copies-of the following monthly operating reports for the month of December 1985.are being sent to you.

Average Daily Unit Power Level Operating Data Report Unit Shutdowns and Power Reductions Major Plant Modification Safety Related Work Orders Operating Summary Refueling Information Sincerely yours, yI a.fe-J. M.

Zupko, Jr.

General Manager - Salem Operations.

JR:kcb cc:

Dr. Thomas E. Murley Regional Administrator USNRC Region I 631 Park Avenue King'of Prussia, PA 19406 Director, Office of Management Information and Program Control U.S. Nuclear Regulatory Commission Washington, DC 20555 Enclosures 8-1-7.R4 The Energy People j

95 2183(t iW 12 m