Docket No. 50-336 B16320

-l i

Millstone Nuclear Power Station, Unit No. 2 l

Facility Operating License No. DPR-65 January 1997 Unit Shutdown and Power Reductions (Revised)

March 1997 9703190119 970313 PDR ADOCK 05000336 R

PDR

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-336 UNIT NAME Millstone Unit 2 DATE 03/05/97 COMPLETED BY S. Stark TELEPHONE (860) 447-1791 EXT 4419 REPORT MONTH: January 1997 (Revised) 2 No.

Date Type' Duration Reason Method of License System Component Cause & Corrective (Hours)

Shutting Event Code' Code

  • Action to Down Reactor' Report #

Prevent Recurrence 97-01 03/07/96 S!F 744*

B;D 4

N/A N/A N/A Scheduled: Continued mid cycle surveillance testing from previous year.

Forced: Continued from previous year. NRC Category til facility; NRC Confirmatory Order requiring independent corrective action verification; NRC order requiring third party review of Millstone Station employee concerns program; design basis verification for response to NRC pursuant to 10CRF50.54(fl.

'F: Forced Reason Method

'lEEE Standard 805-1984, 2

S: Scheduled A - Equipment Failure (Explain) 1 - Manual

" Recommended Practices B - Maintenance or Test 2 - Manual Scram for System Identification in C - Refueling 3 - Automatic Scram Nuclear Power Plants and D - Regulatory Restriction 4 - Continued from Previous Month Related Facilities" E - Operator Training & License Examination 5 - Power Reduction (Duration = 0)

F - Administrative 6 - Other (Explain)

  • lEEE Standard 803A-1983, G - Operational Error (Explain)

" Recommended Practices H - Other (Explain) for Unique identification in Power Plants and Related Facilities - Component

  • Revised due to typographical error Function Identifiers"