Monthly Operating Rept for Oct 1985
ML20136G784
Person / Time
Site: Callaway 
Issue date: 10/31/1985
From: Miltenberger S, Pratte D
UNION ELECTRIC CO.
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
ULNRC-1204, NUDOCS 8601080558
Download: ML20136G784 (6)


Text

{{#Wiki_filter:: i: ~ e s 7_ t MONTHLY OPERATING REPORT p h 4 DOCKET NO. 50-483 E UNIT NAME CALLAWAY UNIT 1 h DATE NOVEMBER 13, 1985 C COMPLsIsu BY D. B '. PRATTE [5 TELEPHONE M14) 676-8745 [ { PART A OPERATIONS

SUMMARY

[ 4~3 h OCTOBER 1985 g The unit was operated at full power for the month of October with the following h f! exceptions: w, 1. On 10/2/85 the unit tripped due to a personnel error during sruveillance ij testing of an RCS temperature loop. n. ~ On 10/7/85 the turbine generator was manually taken off line due to EHC 2. s tubing line failure to a main turbine control valve. ,yy 3. On 10/18/85 power was reduced to approximate 1v 68% to perform maintenance E Y on secondarv system equipment. -{i D PART B PORV AND SAFETY VALVE

SUMMARY

(! hi u, NONE iE' a 3 .~6 6 ,k 1 E s ? N 8601080558 851031 ~ PDR ADOCR 05000483 E6 R PDR y CA-#804 K 05/09/84 h QDP-ZZ-04204 Page 1 of 4 ppQ l[l ? . v.- - -,, --4. hi ?;ct'*~. f,Ao,.hr - 5 t ( ~ ",_ r'r 4.>, ',,2!? s - ' : ~' 's' , 's - .. g7 i, k. _ I ,m

p. t,-j n e: g !? U l-1, Part C AVERAGE DAILY UNIT POWER LEVEL C p. 50-483 DOCKET NO. UNIT Callaway f/ DATE NOVEMBER 13, 1985 COMPLETED By f B. PRATTE pz TELEPHONE (314) 676-8745 p; L: 1: L: MONTH OCTOBER 1985 l,5 R DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL f (M. e-Net) p W (MWe-Net) 1 1125 17 1107 855 1097 h 2 gg b, 11 756 3 j,, pi. 725 852 E 4 20 ra 1116 1111 5 21 '6 ' 1118 1115 f I 22 872 1113 7 23 0 1110 8 24 ,j 1118 f-394 25 9 991 1122 k 10 26 1104 1167 11 27 h 1094 1124 12 g 1099 1124 13 3 1105 1123 14 30 1122 1123 15 31 1111 16 O j'. ff C 0[ 4 Page 2 of 4 QDP-ZZ-04204 E M25_.o_..p: n-r. =gtf-, ,,ggj :,, y _

j t t: k f Part D OPERATING DATA REPORT h 50-483 DOCKET NO. UNIT Callaway DATE NOVEMBER 13,-1985 D. B. PME COMPLETED BY i TELEPHONE (314) 676-R745 ( h i OPERATING STATUS OCTOBER 1985 745

1. REPORTING PERIOD:

Gross HOURS IN REPORTING PERIOD: e

2. CURRENTLY AUTHORIZED POWER LEVEL (Mwti: 3411 MAX. DEPEND. CAPACITY (MWo.Neti:

1170 OESIGN ELECTRICAL RATING IMWo.Neti: 1171* At Stretch reactor power level which is ~ 5 not currently authorized under the operating license.

3. POWER LEVEL TO WHICH RESTRICTED flF ANY) (MWo. Net):

L

4. REASONS FOR RESTRICTION IIP ANY):

b THIS MONTH YR TO DATE CUMULATIVE 716.8 6768.8 7071'.3

5. NUMSER OF HOURS REACTOR WAS CRITICAL h

0 0 0 f i

6. REACTOR RESERVE SHUTDOWN HOURS f

669.3 6603.6 6906.1

7. HOURS GENERATOR ON LINE 5
8. UNIT RESERVE SHUTDOWN HOURS 0

0 0

9. GROSS THERMAL ENERGY GENERATED IMWHI

.7.906.146 70.R69 612 91 R AA 1 s7 lq b 758,545 7.045.187 7.384 367

10. GROSS ELECTRICAL ENERGY GENERATED (MWM)...
11. NET ELECTRICAL ENERGY GENERATED (MWH) 720.034 6.686.596 7.004.619 96.2%

92.R% ol_1% [

12. REACTOR SERVICE FACTOR
13. REACTOR AVAILA81LITY FACTOR.

96.2% 92.87. 41_1%

14. UNIT SERV 6CE FACTOR...

89.8% 90.5% 40 o% 89.8% 90.5% 90.9%

15. UNIT AVAILAGILITY FACTOR 86.3%

81.8% 82.4%

16. UNIT CAPACITY FACTOR IUsene MDCI 82.5%*

78.3%* 78.R%*

17. UNIT CAPACITY FACTOR (Usene Dessen Mml..............

1s. UNIT FORCED OUTAGE RATE

  • .8%

5.1% 4 4%

19. SHUTDOWNS SCHEDULED OVER NEXT 4 MONTHS (TYPE. DATE. ANO OURATION OF EACHt:

Refuel, 2/28/85, approximately 42 days. 7

20. IF SHUT DOWN AT END OF REPORT PERIOD. ESTIMATED DATE OP STARTUP:

j, 9 h c, }nkh Nq E 4 Page 3 of 4 QDP-ZZ-04204 l-C'~.3:72421% w"zcS!%%a * ' r n x_ x.p., _. . ;c. m:u <

J' O .4 Part E DOCKET NO. 50-483 il UNIT SHUTDOWNS AND POWER REDUCTIONS UNIT NAME callaway NOVEMBER 13, 1985 I) ATE D. B. PRATTE COMPLETED BY REPORT MONTIl OCTOBER 1985 TELEPiiONE (314) 676-8745 METHOD OF TYPE SHUTTING DOWN F: FORCED DURATION THE REACTOR OR NO. DATE S: SCHEDULED (HOURS) REASON REDUCING POWER CORRECTIVE ACTIONS / COMMENTS 21 851002 F 23.7 G 3 Unit tripped while I&C was performing h troubleshooting in conjunction with a RTD cross calibration procedure. LER 85-042-00. 22 651007 F 10 A 4 Turbine generator was taken off line due to an EHC oil leak on main turbine control valve #2. 23 851018 S 42 B 1 Unit load reduced to 68% to perform II maintenance on secondary system equip-ment. l Es - R Y: REASON IETMOD A: EQUlFMENT FAILURE (EXPLAIN) 3: MANUAL. R: MAINT.OR TEST 2: MANUAL 3 CRAM C: REFUELING 3: ABITOMATIC SCRAM D: REGULATORY RESTRKTION 4: OTIGER (EXPLAIN) i E: OPERATOR TRAINING AND LICENSE EXAMINATION F: ADMINISTRATIVE G OPERATIONAL ERROR (EXPLAIN) CA-#804 It OTHER(EXPLAINI 05/09/84 Page 4 of 4 QDP-ZZ-04204 J:%wmmm"m m m mmm7?r m wz m m y.m v mrmnmzvm-7--.~~ ~

P c' Wand UNION ELECTRIC COMPANY Callag Plant November 13, 1985 Director, Resource Management Nuclear Regulatory Commission Washington, DC 20555 ULNRC-1204

Dear Sir:

DOCKET NUMBER 50-483 CALLAWAY PLANT UNIT I FACILITY OPERATING LICENSE NPF-30 MONTHLY OPERATING REPORT OCTOBER 1985 The enclosed Monthly Operating Report for October 1985 is submitted pursuant to section 6.9.1.8 of the Callaway Unit 1 Technical Specifications. vNf S. E. Miltenberger / Manager, Callaway Plant ?[# G2C Q MET /IIRC/DBP/drs Enclosure cc: Distribution attached O f? 6 \\ l Mailing Address: P.O. Box 620 Fulton, MO 65251

cc distribution for ULNRC-1204 with enclosures Mr. James G. Keppler Regional Administrator Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, DC 20555 NRC Resident Inspector I l M}}