ML20136F944

From kanterella
Jump to navigation Jump to search
Forwards Safety Evaluation of NEDE-24011, GE Std Application for Reload Fuel Amend 8. Methods Explained Meet Stability Criteria,Per GDC 10 & 12.SER Supersedes 850405 SER Re NEDE-22277-P-1
ML20136F944
Person / Time
Issue date: 04/17/1985
From: Rubenstein L
Office of Nuclear Reactor Regulation
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML20136A677 List:
References
TAC-49898, TAC-53361, TAC-56516, NUDOCS 8504290470
Download: ML20136F944 (1)


Text

_ _ _ _ _ __

,o- ee a

  1. R 17 BBS MEMORANDUM FOR: D. M. Cr'itchfield, Assistant Director for Safety Assessment. DL FROM: L. S. Rubenstein, Assistant Director e for Core and Plant Systems DSI

SUBJECT:

STAFF EVALUATION OF GE TOPICAL REPORT NEDE-24011 (GESTAR)

AMENDMENT 8 Report

Title:

Compliance of General Electric Boiling Water Reactor Fuel Designs to Stability Licensing Criteria .

Report Number: NEDE.24011, Amendment 8 Report Date: September 1983 Responsible Branch: Standardization and Special Projects Branch Project Manager: Dave Moran Review Branch: Core Performance Branch TACS Nos.: 49898/56516/53361 Review Status: -

Complete The Core Performance Branch has completed the review of the General Electric topical report NEDE-24011 Amendment 8 and our evaluation is attached. We find the methods explained in this topical meet the stability criteria set forth in General Design Criteria 10 and 12 provided they are used within the bounds described in the staff position in Section 4.0 of our Safety Evaluation.

This SER includes the evaluation of NEDE-22277-P.1 which was enclosed in our memo of April 5, 1985. Since NEDE-22277-P-1 is referenced in NEDE-24011, this SER supersedes and is a replacement for " Staff Evaluation of GE Topical Report NEDE-22277.P-1," dated April 5,1985.

Original signed b)

L S.Rubenstein L. S. Rubenstein, Assistant Director for Core and Plant Systems, DSI

Enclosure:

As stated DISTRIBUTION:

cc: R. Bernero Central Files C. Thomas CPB R/F D. Moran LRubenstein G. Thomas LPhillips W. Hodges RLobel B. Sheron - DFieno

. GSchwenk e

Contact:

G. A.'S'chwenk, CPB:DSI X-29421 gggy g P VIOUS CONCURRENCE

,7, j tu n a,rn :vw :t,rp :D5 -r  : CPS  :  :  :

s............:........... : . . . ., f. . . . ..%

. 0 51 , , . . . . . . . , . . . . . ._,,_,,___,,,,,....,,,,,,...,

lE**GSchwenk  :*LPhillipt erlinger :LHDe in :  :  :

-.g............:..........  :............:............___.......,_.. _,,. ..........

E 23/15/85 :3/15/85 :4/ I4/85 :4/ # 7/85  :  :  :

ICIAL RECORD COPY n