Forwards Sample Ltr & List of 11 Utility Companies That Have Been Notified of Condition of over-stressed Auxiliary Host on One Whiting Crane.Condition Believes Not to Be Reportable Under Part 21
ML20136E755
Person / Time
Site: Oyster Creek
Issue date: 03/12/1997
From: Kwasny M
WHITING CORP.
To:
NRC
References
NUDOCS 9703130317
Download: ML20136E755 (6)


Text

-

SENT BY: XER0X Telecopier 7017; 3-12-97 ; 8:62 ;

7082105035-+

301 816 5151:# 1 1

i C

0 V

E R

Facsimile 5

H E

E T

To:

Director's Office of Inspection and Enforcement Fax #:

(301) 816-5151 g

Subject:

Over-stress of aux hoists on Whiting Cranes Date:

March 12,1997 Pages:

6, including this cover sheet.

{

COMMENTS:

i Recently, we at Whiting have become aware of a condition of an over-stressed auxiliary hoist on one of our cranes. Based on this, we have reviewed a series of cranes and are in the process of sending notices to affected customers. Attached is a 4

sample letter and a list of the 11 utility companies that we have notified of this condition.

The authorization of loads up to 40% of rated capacity, as described in this fax, is a conservative generalization and will be addressed on a case-by-case basis with each customer. Separate specific instructions by Engineering or a fax will authorize loads as high as 60% of rated capacity for a specific appilcation.

J The cranes as designed meet the current requirements of AISC, but vlolate the requirements of CMAA. We are authorizing operation at a reduced capacity which will bring operation.Into conformance with both requirements.'We do not believe this to be reportable under 10 CFR 21, but we have notified these companies so that they may do further evaluations.

if further information is required, I can be contacted at (708) 331-4000, extension 4020.

Sincerely,

%f~y Mark J. Kwasny (I

i Quality Assurance and Customer Service Manager l

?Q !s l cc: JLK. CJS. ERT FPT, RJK, ALM. WAH. JSP. EHH, MAW, BHT. file 970313o317 97o312 l]l{UK3ll@lll$$lllljl DR ADOCK 05oo 9

1 SENT BY: XER0X Telecopier 7017: 3-12-97 3 8:43 ;

7082105035-.

301 818 5151;# 2 C

0 V

E R

=

Facsimile S

H E

E T

)

DATE:

March 11,1997 -

winns cap =mi

'157001.athrop Ave.

Harvey !L 60426 TO:

.GPU Nuclear

~

! Route 9 South rd $$

' Forked River. NJ-08731 Jim Hilderbound, Plant Maintenance Director FAX #:

(609) 971-4472 RE:

Your Whiting crane (s) serial number (s),10044.

This is to inform you of a concem related to the continued operation of crane (s) 10044. This notification is limited, and only customers receiving this notice are required to take action.

An analysis of the auxiliary hoist on a crane similar to the referenced crane (s) has revealed some over-stressed conditions. These over-stressed points are not likely to result in a failure, but are being reported so that further evaluations and corrections can be made. The main hoist is not affected by this condition and can continue to be.used with out restriction. As an interim measure we recommend taking the auxiliary hoist out of service rather then derating because variations in your design require further evaluation be done before use.

If the above provisions are followed, the crane can continue to be used without additional concern.

Whiting Corporation, a Delaware Corporation, has no direct responsibility for the design of equipment sold by Whiting Corporation, an Illinois Corporation, prior to an asset purchase in 1984. Based on current information, it.does not appear that this condition is reportable 'under 10 -

CFR 21. However, we are passing this information on to all affected utilities for their evaluation.

Until the time renairs can be made you must either discontinue use or derate the canacity of the auxillarv hoist to 40% of the original rated canaeity on the referenced cranes.

Whiting Corporation and our sister company Whiting Services Inc. are willing to assist in repair of these trollies by providing engineering, repair parts bills of material, and field services Page 1 of 2

SENT BY: XER0X Telecopier 7017; 3-12-97 ; 8:43 :

7082105035*

301 816 5151;#.3

.i

. Mark Kwasny - Whiting Corporation j

RE: Aux. Hoist Over-stress Problem March 11,1997 Page 2 supervision.

1 You may contact Mark Kwasny or Ben hmas of our Customer service department at 708-331-.

4000 extension 4020 or 4025 for further instructions and information, or to arrange for evaluations and specific repairs.

Very tmly yours, m__

{

Mark J.Kwasny Manager ofQuality Assurance &

Customer Service

?-

cc: JLK; CJS; ERT; FPT; RJK; ALM; WAH; JSP; EHH; MAW; BHT; file i

4 i

i 1

1 4

Page 2 of 2

i i

1 l}

, Listing of Customers Sent Fax on Aux Hoist Overstress ProblemsDated March 11,1997 S Ccmpany indiana & Michigan Power Address 1 1 Cook Place j 3 City Bridgman i

State MI 8 Zip 49106 coenments:

Attn '

~ John Sampson j

Crsne_sn 10039,10040 Attn _ title Plant Manager PI:nt r

l 3 Fcx_no (616) 466-2415

g Gttmpany UPU Nuclear

! ; Address 1 Route 9 South

8 City Forked River s

i " State NJ Zip,

08731 comments:

Attn Jim Hilderbound Crane sn 10044 l,, Attn _itle Plant Maintenance Director Plant Fax _no (609) 971-4472 i

Gcmpany Norm AUanUc Energy Service Address 1 P.O. Box 300, Route 9 South

[ State City Seabrnok y

NH

, = Zip 03874 comm nts-A Attn Bill Ditrofio

- Craie sn 10950,10951 3 Attn _itle Plant Manager Plant i t Fax _no (603) 773-7300

. 2 Gompany Consondated Edison Gompany of New York, Inc.

l 5 Address 1 Indian Point, Unit 2 Broadway Beakley

City Buchanan

~- State NY

! M ' Zip 10511 comments:

l @ Crane _sn Attn Roger Noah 9548 si Attn _ title Safety Supervisor i - Plant

$ Fdx_no (914)734-5124 4

i j

3 Listing of Customers Sent Fax on Aux Hoist Overstress ProblemsDated March 11,1997 i

S Company South CaroHna Electric & Gas

[ Address 1 P.O. Box 88 g City JenkinsviNe 4

J State SC f M Zip 29065 coauments:

Attn Mike Fowlkes ARar Engineering further evaluated their Crane an 11027 crane, it was decided that it was under i

Attn itie Manager of Nuclear Licensing

    • '"paance. sent a taikw.p leaer id"""'"G **'" d *'* ad Wns i

r PI nt

    • '""'N"'"*'***d*'

1 yFax_no (803) 345-4356

g company Houston Light & Power
; Address 1 South Texas Project P.O. Box 289

- E City Wadsworth j " State TX Zip 77483 c--es:

Attn Joe Sheppard Amor Engineering fwther evaluated Seir Crane sn 11258,11257 craae, at-decided mat itm under Attn itle Manager Nuclear Licensing

-2 sent a us-p setter pi g infonalng thosn of this and instructmg 3

! O Fax _no (512)972 8298 i e company c-..- _-_ :--._ :== Edison Address 1 101 Shiloh Boulevard

city Zion _

j y State IL O Zip 60099 comunents:

A Attn Tony Broccolo Crane _sn 9958,9959

_gg Attn _ title Station Manager e-Plant

tFar_no (847)731 4266 XGompany Public service Electric a sas 3 Address 1 Salone No.1 P.O. Box 236 3 City Hancock's Bridge i

,

  • State NJ

! sZip 08038 comuments:

% Attn Tom Williams i.. Grane_sn 10004,10005 n; Attn _ title Manager, Quality Engineer & Procurement Plant

@.ai_no (609) 339-3997

\\

5 Listing of Customers Sant Fax on Aux Hoist Overstress ProblemsDated March 11,1997 1 E C::mpany New York Power Authority

  • Address 1 Indian Point, Unit 3 P.O. Box 215

, 3 City Buchanan State NY i

a Zip 10511 comments

Attn Jim Comiotes Crane _sn 9890 Attn _ title Ucensing Manager PI:nt 3 Fax _no (914) 739-5427 g company Southern Nuclear Operatmg Company

Address 1 P.O. Box 1295
2 City Birmingham i " State AL Zip 35201 comments

Attn Brad Moore I

Crane an 10401 & 10402 i

Attn _ftle Manager of Ucensing

Plant l

3 Fax _no (205) 992-5002

;; company

. Georgia Power Gompany Address 1 Vogtle Nuclear Plant Reactor Building

[ City Burke County

<= State GA ibZip 30341 comments:

A Attn Charles Myers i.- Crane sn 11422 & 11423 3 Attn _ title Safety Manager 1

e-Plant i t Fcx__no (706)826-3681 P.

', ;s r

X 4

~

i !E

~

..