7

+

DISTRIBUTION:

  1. e DN 50-320 p;

,. ' *b -

NRC PDR F

Local PDR L

DCS TMI HQ r/f TMI Site r/f November 8, 1985 WDTravers

~

NRC/THI-85-086 MTMasnik RAWeller l

Docket No. 50-320 PGrant RCook F

Mr., F. R. Standerfer CCowgill Vice President / Director, THI-2 LChandler GFU Nuclear Corporation IE P. O. Box 480 ACRS Middletown, PA 17057 M-town Office Service List

Dear Mr. Standerfer:

Subject:

Resolution of Quality Assurance Issues Relating to Use of Defueling Canisters In my letter of November 5,1985 (reference 1) the Nuclear Regulatory

-Commission (NRC) staff approved General Public Utilities Nuclear Corporation's (GPUN)designofcanistersproposedforuseduringdefueling. This letter is

- provided to document our review and to grant approval for the use of the initial four defueling filter canisters (F401 - 404). Additionally, with the provision'that GPUN complies with the requirements set forth in this letter, we are granting approval for use of the remaining defueling canisters.

An NRC inspection at the Nuclear Energy Services (NES) Manufacturing facility in Greensboro, North Carolina, identified numerous deficiencies in the implementation of the Quality Assurance (QA) program applicable to the Audits and fabrication of defueling canisters for the THI-2 project.

surveillances by GPU Nuclear and Bechtel personnel at NES both prior to and after the NRC inspection identified similar deficiencies. These QA program deficiencies have raised questions on the conformance of NES fabricated canisters with the design specifications. For the first four hiter canisters received from NES GPUN/Bechtel implemented an extensive QA revi~w program to verify that the canister's as-built critical attributes met the design specification. References' 2, 3, and 4 describe the verification program and its results in detail. Based on a review of those references, discussions with your staff, and an independent NRC inspection of selected portions of the document package associated with the subject canisters, we concluded that the QA issues relating to the use of these canisters have been satisfactorily resolved. Most of the issues involved poor record keeping and inattention to detail by NES,~ but had only minor safety significance when examined individually. However, we determined that there were four potentially significant issues (viz. material receipt inspection, upper head material traceability, catalyst loading traceability and poison loading traceability),

that hold a potential for unacceptable operational risk. These issues.

required more extensive review and evaluation including direct inspections by the NRC staff. The attachment to this letter discusses these four potential safety significant issues, the safety implications of each, and the resolution determined acceptable'to the NRC staff.

A Based on the evaluations discussed in the attachment, the NRC staff has determined tnere is reasonabte assurr2nce ttt&defuWeg filter edstm

-F-40lrF-402,,..E 403,..and..E-404..have..acen.. constructed so they,,ca o,,,c.,

n 8511200253 851100

' ' ~ '

  • DR ADOCM 05000320 g

PDR unc ronu na no.nomac" 0"o OFFIClAL RECORD COPY

~

~

'ttr.~ F. R. Standerfer

& November 8, 1985 safely perform their intended functions. The NRC staff has determined that-use.of these canisters will not pose a significant risk to the health and

~ safety of the workers or the public, lie therefore approve the use of these four filter canisters for their intended defueling functions.

With regard to the adequacy of other defueling canisters fabricated by NES, ~

the NRC staff understands that GPUN plans to evaluate, based on vendor perfomance and/or detailed QA reviews, the need for continuing their augmented QA review program. The. staff concurs in this approach and will

. continue to monitor its effectiveness in assuring that canisters meet their design specifications.

liith the following provisions the staff approves the use of defueling canisters provided to GPUN by its vendors.

(1) Submittal to NRC of independent verification of catalyst loading in both upper and lower heads of all defueling canisters.

(2) Submittal to NRC of independent verification of all' poison (B C) tube 4

loading and installation for all filter and knockout canisters.

'(3) Completion of action items and comitments established in reference 5.

(4) Notification to NRC of any. planned reduction of your augmented QA review program for NES supplied canisters.

If you have any questions, please call me.

Sincerely, DRIGINAL SIGNED BY:

Wimam D. Travers ililliam D. Travers Acting Director Three Mile Island Program Office

Enclosure:

As stated cc:

T. F. Demmitt R. E. Rogan S. Levin W. H. Linton J. J. Byrne A. W. ililler Service Distribution List (see attached)

_ OFFICE)

,,,} g Q,,,,,

sunnah wa......HDTC4VCCS.

- * ^ " >

11.l0.!85...... '. '. 00

' une comu ais tio-so unCu o24o ry,.1CIAL RECORD COPY

REFERENCES 1.

Letter NRC/TMI 85-083, W. Travers to F. Standerfer, dated November 5, 1985, Defueling Canister Technical Evaluation Report.

2.

Letter 4410-85-L-0202, F. Standerfer to B. Snyder, dated October 10, 1985, Summary of GPU Nuclear /Bechtel Quality Assurance Surveillance Program for the First Four Filter Canisters, with attachments.

3.

Letter 4410-85-L-0210, F. Standerfer to W. Travers, dated October 28, 1985, Resolution of Quality Assurance Issues Relating to the Defueling Canisters, with attachments.

4.

Letter 4410-85-L-0219, F. Standerfer to W. Travers, dated November 4, 1985, Canister Checklist Revision 3, with attachments.

5.

Letter 4410-85-L-206, F. Standerfer to B. Snyder, dated October 23, 1985, Early Defueling Safety Evaluation Report Response to Comments.

4410-85-L-0'21, F. Standerfer to W. Travers, dated November 4, 6.

Letter c

1985, GPU Nuclear Quality Assurance Acceptance of First Four Filter Canisters.

7.

NRC letter from G. Zech to F. Sugar, Nuclear Energy Services, dated July 26, 1985, transmitting Inspection Report 99901018/85-01.

8.

Nuclear Energy Services letter from F. Sugar to G. Zech, NRC, dated August 25, 1985, Response to NRC Inspection Report 99901018/85-01.

9.

NRC letter from G. Zech to F. Sugar, Nuclear Energy Services, dated October 15, 1985, Regarding Response to Inspection Report 99901018/85-01.

10. Safety Analysis Report for the NUPAC 125-B Fuel Shipping Cask, Docket Number 71-9200, Revision 1, dated October 31, 1985.

m

r; ATTACHMENT Resolution of Potential Safety Issues Pertaining to Defueling Canisters F-401, F-402, F-403, and F-404 The following is a discussion of four potentially significant quality assurance issues pertaining to defueling filter canisters, serial numbers _

F-401, F-402, F-403, and F-404, fabricated by NES Manufacturing. Based on review of the results of an NRC inspection and the findings of licensee audits of the fabrication facility (references 7, 8, and 9), these four issues are those considered by the NRC staff to have the greatest potential for influencing the safety performance of the defueling canisters.

Included is a discussion of the safety implications and the staff's basis for accepting the resolution of each issue.

I.

MATERIAL RECEIPT INSPECTION The vendor's material receipt inspection program was determined not to be adequately implemented in that complete records of inspections were not always maintained and that dimensional checks of some components may not have been performed.

In addition, the NRC inspection team found that Certified Material Test Reports (CMTR) or Certificates of Compliance (C of C) were unavailable for some ~ material.

,The safety implication of this issue is that failure to assure that canister components meet design dimensional specifications could affect proper component fit up during fabrication. This could conceivably result in deviations from the design that was evaluated during extensive structural analysis done to predict the canisters response to external loads applied during postulated accidents.

Failure to meet the design material specifications could have negative affects on the canisters structural integri ty.

It could further affect the canister's integrity during long-term

' storage in a pool of water.

Based on our review of the information presented in the referenced documents and discussions with GPU Nuclear and Bechtel staff, the staff has determined that there is reasonable assurance that the material used in the fabrication of the four subject filter canisters meets the required specifications.

Review of records by a GPUN/Bechtel team at the vendor's site, as well as further review by the vendor, determined that material not inspected by the vendor had been examined at its source by Bechtel QA personnel. This material had been purchased by Bechtel and shipped directly to NES for installation in the canisters. The inspection team verified that all missing CMTR's and C of C's applicable to the first four filter canisters had been located by NES and that NES personnel had reviewed them to assure the material's conformance to design specifications. The team verified through review of shop travellers and interviews with NES personnel that there had been an adequate level of NES quality control (QC) review to assure proper component fit up during fabrication to assure that the canister's as built dimensions met the design m

~

. e tolerances. The. staff performed an inspection on selective documents and verified that the followup activities were appropriate and completed.

II. UPPER HEAD MATERIAL TRACEABILITY Traceability to a heat number was not maintained on the material used for fabrication of the canister upper heads.

The safety significance of this issue is similar to that discussed above, in that failure to assure that the materials used in fabrication of the canister's pressure retaining boundary meet the design specifications could affect the overall structural integrity and degrade the performance of the canister during both normal and postulated accident conditions.

The' licensee has provided the NRC staff with additional information that provides reasonable assurance that the upper heads for the four subject filter canisters were fabricated from material meeting the design specifications.

The licensee's review of the fabrication process at NES determined that heat numbers had been stamped on the " slugs" delivered to NES for manufacture of the upper heads. These slugs were sent by NES to a subcontractor who performed the final machining. The subcontractor maintained traceability of the material throughout the machining process and stamped the heat numbers on the inside surface of the finished heads. These were returned to NES where QA receipt inspections verified the presence of the heat numbers. After installation of the heads, the heat numbers were no longer visible, therefore, an individual canister head cannot be traced back to a specific heat number.

However, review of records by GPUN/Bechtel personnel verified that suitable documentation exists to assure that a given canister head was built from material from one of a group of heat numbers. Certified Material Test Reports exist for all heats from which a head could have been made.

The staff finding agrees with this determination and this provides reasonable assurance that the material used is in conformance with the design specification.

III. NEUTRON ABSORBER MATERIAL TRACEABILITY Neutron absorber material (poison) traceability was not maintained and unapproved procedures were used for poison loading.

Neutron absorber material is installed in the filter canisters to assure that the canisters and their contents remain subcritical under all postulated normal and accident conditions during onsite handling and storage and during transportation.

Based on a review of the documents provided by GPU Nuclear, the NRC staff has determined that there is reasonable assurance that the B C pellets supplied by 4

, ' Advanced Refractory Technologies, Inc. to NES meet all design specifications.

However, the documentation submitted previously had not established in acceptable level of confidence that the 8 C pellets were installed in the 4

filter canisters poison rod assemblies or that the properly filled assemblies were inserted into the filter canisters. Multiple poison rod assemblies were filled with B,C under a single shop traveller and assemblies were installed in all four cani3ters under single shop traveller.

The travellers did not have multiple signatures indiccting that the required procedural steps had been performed or verified by QC r trsonnel for each assembly. Because of the identified inadequacies in che implementation of the vendor's QA program, the

. travellers used for this process do not provide acceptable docummtary evidence. The licensee has stated that the requirement for the achtel Supplier Quality Representative (SQR) to witness the installation af the poison rods into the filter canistersilas bypassed for these four canisters.

However, radiographic examinations were performed by NES to verify the presence of the poison pellets.

The staff has reviewed results of these radiographic examinations and

' determined this provides adequate assurance that the poison pellets were installed. Additionally the staff has performed an independent review of the filter canister criticality analysis.,This analysis, which is part of the licensing review of the NUPAC-1258 fuel shipping cask / NNrence 10) was performed to determine effects from transportation ac.cidents. This analysis determined that for the worst case deformed canister geometry, a single filter canister and an array of canisters would still have greater than a five percent shutdown margin even if the poison material was removed and the space filled with the optimal ratio of fuel and water.

Based on our_ review, the staff concludes that reasonable assurance exist that the filter canisters and their contents will remain subcritical under all postulated normal and accident conditions.

IV. CATALYST MATERIAL LOADIriG Review of the vendor's implementation of their QA program raised questions regarding assurance that adequate catalyst quantities were installed in canisters.

Failure of the catalytic recombiners to perform as designed could result in the formation of combustible gas mixture inside a canister due to radiolytic decomposition of residual water.

The NRC staff has determined that the information submitted in the licensee's letter 4410-85-L-0210 (reference 3) to the flRC provides reasonable assurance that the catalytic recombiners have been installed in the four filter canisters. Attachment 1 to that letter stated, "The Bechtel SQR, [ Supplier Quality. Representative], visually verified the presence of both types of d-1

.. catalyst in.100% of the bottom heads and upper heads prior to screen installation." Since the design of the recombiner elements are such that the f required amount of catalyst (25 grams in each lower head element and 50 grams in each upper head element) will nearly fill the element cartridge, visual verification of its presence would readily detect the loss of a significant amount of catalyst material. Additionally, there is significant conservatism in the design of the recombiner elements.

The staff's assessment of this conservatism was documented in the Canister TER approval. Based on the above there is reasonable assurance that sufficient catalyst material has been installed in each element to perform-the intended function.

Based on our review of all supporting information and our direct inspections, the staff has determined that the resolution of these issues is acceptable and that there is reasonable assurance that filter canisters F-401, F-402, F-403, and F-404 can be used for their intended purpose without jeopardizing the public health and safety.

2 9

9 y-

...m._

g..,7 n..m._.,,3.-

y

~

TMI-2 SERVICE LIST Dr. Thomas Murley-W111ts'8taby. $tte Manager Regional Administrator. Region i U.S. Department of Energy U.S. Nuclear Regulatory Comission P.O. Son 88 631 Park Avenue Middletown. PA 17057-0311 King of Prussia. PA 19406 David J. McGoff

~ John F. Wolfe. Esq., Chairman.

Division of Three Mile Island Programs

  • Administrative Judge NC-23 p

3409 Shepherd St.

U.S. Department of Energy Chevy Chase. MD.

20015 Washington. D.C.

20545 Dr. Oscar H. Paris William Lochstet

. Administrative Judge 104 Davey Laboratory Atomic Safety and Licensing Pennsylvania State University Board Panel University Park. PA 16802 U.S. Nuclear Regulatory Comission Washington. D.C.

20555 Randy Myers. Editorial The Patriot Dr. Frederick H. Shon 812 Market St.

Administrative Judge Harrisburg. PA 17105 Atomic Safety and Licensing Board Panel Robert B. Borsum U.S.' Nuclear Regulatory Comission Babcock & Wilcox Washington. 0.C.

20555 Nuclear Power Generation Division Suite 220 Karin W. Carter 7910 Woodmount Ave.

Assistant Attorney General Bethesda, M3.

20814 505 Esecutive House P.O. Box 2357 Michael Churchhill. Esq.

Harrisburg. PA 17120 PILCOP 1315 Walnut St.. Suite 1632 Dr. Judith H. Johnsrud Philadelphia, PA 19107 Environmental Coalition on Nuclear Power Linda W. Little 433 Orlando Ave.

5000 Hermitage DR.

State College. PA 16801 Raleigh NC 27612 George F. Trowbridge Esq.

Marvin I. Lewis Shaw. Pittman. Potts and 6504 Bradford Terrace Trowbridge Philadelphia, PA 19149 1800 M. St., NW.

Washington, D.C.

20036 Jane Lee 183 Valley Rd.

Atomic Safety and Licensing Board Panet Etters.PA 17319 U.S. Nuclear Regulatory Comission Washington, D.C.

20555 J.B. Liberman. Esquire Berlack.Israels. Liberman Atomic Safety and Licensing Appeal Panel 26 droadway U.S. Nuclear Regulatory Comission New York, NY 10004 Washington, D.C.

20555 Walter W. Cohen, Consumer Advocate Secretary Department of Justice U.S. Nuclear Regulatory Commission Strawberry Square 14th Floor ATTN: Chief. Docketing & Service Branch Harrisburg, PA 17127 Washington. D.C.

20555 Edward O. Swartz Mr. Larry Hochendoner Soard of Supervisors Dauphin County Comissioner Londonderry Township P.O. Box 1295 RFD fl Geyers Church Rd.

Harrisburg. PA 17108-1295 Middletown. PA 17057 John E. Minnich. Chaf rperson.

Robert L. Knupp. Esquire Dauphin County Board of Comissioners Assistant Solicitor Dauphin County Courthouse Knupp and Andrews Front and Market Streets P.O. Box P Harrisburg, PA 17101 407 N. Front St.

Harrisburg. PA 17108 Dauphin County Office of Emergency Preparedness John Levin. Esquire Court House. Room 7 Pennsylvania Public Utilities Com.

Front & Market Streets P.O. Box 3265 Harrisburg. PA 17101 Harrisburg PA 17120

' U.S. Environmental Protection Agency Region !!! Office ATTN: EIS Coordinator Curtis Building (Sixth Floor)

J 6th. Walnut Streets Philadelphia. PA 19106 Mr. Edwin Kintner Executive Vice President Thomas M. Gerusky Director General Pubite Utilities Nuclear Corp.

Bureau of Radiation Protection 100 Interpace Parkway Department of Environmental Resources Parsippany. NJ 07054 P.O. Son 2063 i

Harrisburg, PA 17120 Den Kennedy Aa Crable Of fice of Environmental Planning Lancaster %. Era Department of Environmental Resources 8 West Kin 9 Street P.O. Box 2063 tancaster n 17602

)

Harrisburg. PA 17120

...