i OPERATING DATA REcORT (R;v.1)

DOCKET NO. 050-0331 DATE 10-15-85 COMPLETED BY Bradford Thomas TELEPHONE 319-851-7309 OPERATING STATUS Notes I thlt Name Duane Arnol d Energy Center

2. Reporting Perlod September, 1985
3. Licensed Thermal Power (MWt):

1658

4. Nemoplate Rating (Gross MWe):

565 (Turbine)

5. Design Electrical Rating (Net MWe):

538

6. Newlmum Dependable Capacity (Gross MWe):

545

7. Maximum Dependable Capacity (Not MWe):

515

8. It Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since the Last Report, Give Reasons:
9. Power Level to Which Restricted, if Any (Net MWe):
10. Reasons For Restrictions, if Any:

This Month Yr-to-Date Cumulative

11. Hours in Reporting Period 720.0 6551.0 93479.0 I2. Number of Hours Reactor Was Critical 720.0 2524.2 65112.9
13. Reactor Reserve Shut e wn Hours 0

0 150.3

14. murs Generator On-Line 720.0 2502.8 63350.5
15. tmit Reserve $ hut een Hours 0

0 0

16. Gross Thermal Energy Generated (MWH) 1083384 3390108 79850043
17. Gross Electrical Energy Generated (MWH) 364611 1126490 26713844
18. Not Electrical Energy Generated (MWH)

(342866)

(1055373)

(25011524)

19. Unit Service Factor 100.0 38.2 67.8 l
20. Unit Availability Factor 100.0 38.2 67.8
21. thlt Capacity Factor (Using M00 Net)

(92.5) 31.3 52.0

22. Unit Capacity Factor (Using DER Net)

(88.5) 29.9 49.7'

23. Unit Forced Outage Rate 0

0 16.4

24. Shuteens Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

kne 2$. If Shut Down At End 0f Report Period, Estimated Date of Startup N/A 1

AVERAGE DAILY LMIT POWER LEVEL (Rev.1)'

I DOCKET NO. 050-0331 lNIT Duane Arnol d Energy Center DATE 10-15-85 f~

COMPLETED BY Bradford Thomas l'

TELEPHONE 319-851-7309 l'

l MONTH September, 1985 l

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWo-Net)

(MWe-Net) l l'

427-17 484 2

421 18 456 3

427 19 392 4

416 20 497 _

f 5'

420 21 509 I

6 410 22 428 7

406 23

'22 i

8 400 24 522 i

j 9

463 25 513 10 494 26 S I ')

11 503 27 521 12 509 28 531 13 520 29 527 14 507 30

- ( 539)

(

~ 15 507 31 16 *

-501 INSTRlCTIONS

.On this format, list the average elly unit power level in MWe-Net for each ey in the reporting month. Compute to the nearest whole megewatt.

(9/77) l

)

.