I NAC INTERNATIONAL Atlanta Corporate Headquarters 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092 Phone 770-447-1144 www.nacintl.com May 8, 2020 U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD, 20852-2738 Attn: Document Control Desk

Subject:

Reference:

Supplement for NAC' s Request for a Revision to Certificate of Compliance No. 9356 for the NAC MAGNA TRAN Transportation Package.

Docket No. 71-9356

1.

Certificate of Compliance No. 9356, Revision 1, for the Model No. MAGNATRAN Transport Package, U.S. Nuclear Regulatory Commission (NRC), August 3, 2019

2.

MAGNATRAN Transportation Package Safety Analysis Report (SAR), Revision 0, April 2019

3.

ED20190116, NAC's Request for a Revision to Certificate of Compliance No.

9356 for the NAC MAGNATRAN Transportation Package, October 31, 2019

4.

ED20200020, Supplement to NAC's Request for a Revision to Certificate of Compliance No. 9356 for the NAC MAGNATRAN Transportation Package.

February 14, 2020

5.

ED20200031, Supplement to NAC's Request for a Revision to Certificate of Compliance No. 9356 for the NAC MAGNA TRAN Transportation Package, March 12,2020 NAC International (NAC), hereby, commits to revise MAGNATRAN SAR Table 2.1.4-1, "ASME Code Alternatives for MAGNATRAN Components" for the "Fuel Basket Assembly" code alternative.

As part of the current licensing action NAC proposed changes to this code alternative. However, replacing that proposed change with the one below will make the code alternative align with existing approved NRC exemptions to the MAGNASTOR system. The MAGNASTOR exemptions were already approved are; McGuire (ML20098C982); Catawba (ML20098D956); Kewaunee (ML20098D404); and ZionSolutions (ML20098E7I0).

MAGNATRAN SAR Table 2.1.4-1, "ASME Code Alternatives for MAGNATRAN Components", page 2.1.4-6 entry for "Fuel Basket Assembly" the description for "Alternative, Justification and Compensatory Measures" will be revised to:

"Fuel basket materials fabricated from Carbon Steel ~ %", may optionally have impact tests performed on specimens oriented in a direction parallel to the principal rolling direction of the plate, provided that the results from the tests are scaled down to 67% of the measured values before comparing to acceptance criteria Table NG-2331(a)(l) at the Lowest Service Temperature (LST) of-40°F.".

ED20200055

A NAC INTERNATIONAL U.S. Nuclear Regulatory Commission May 8, 2020 Page 2 of 2 In accordance with NAC' s administrative practices, upon final acceptance of this application, the MAGNATRAN-19A, 20A and this letter will be reformatted and incorporated into the next revision of the MAGNA TRAN SAR.

Should you require further details regarding the submittal, please feel free to contact me at 678-328-1236.

Mr. Wren Fowler Director, Licensing.

Engineering ED20200055