ML20135F126

From kanterella
Jump to navigation Jump to search
Discusses Insp of License R-95 on 720626-28 & Forwards Description of Noncompliance Items
ML20135F126
Person / Time
Site: Rhode Island Atomic Energy Commission
Issue date: 09/07/1972
From: James O'Reilly
US ATOMIC ENERGY COMMISSION (AEC)
To: Quirk A
RHODE ISLAND, STATE OF
Shared Package
ML20135F100 List:
References
NUDOCS 8509170164
Download: ML20135F126 (1)


Text

P, I

l

. ~. - - - -

.s i

e-ENCLOSURE Description of Noncompliance Items Rhode Island Atomic Energy Commission Rhode Island Nuclear Science Center Narragansett, Rhode Island 02882 License No. R-95' Certain activities under your license appear to be in noncompliance with license requirements as indicated below:

1.

Paragraph K.3.d of the Technical Specifications to License No. R-95 states in part, " Corrective action shall be taken to avoid exceeding the pH limit..

5.5 to 7.5."

Contrary to the above, all measurements of secondary coolant pH recorded from July 13 to July 23, 1971 were in a range of 7.6 to 8.2.

2.

Paragraph J.1 of the Technical Specifications to License No. R-95 states that the functions of the Reactor Utilization Committee are, in part, "c.

Review at least annually the operating and emergency procedures and the overall radiation safety aspects of the facility," and, "The Reactor Utilization Committee shall maintain a written record of its findings regarding the above."

Contrary to the above, a review of records indicated that the Reactor Utilization Committee did not review procedures and record its findings within the 12-month interval preceding this inspection.

93 PDR s_

e

_ _ _ _ _ _