ML20135D701
| ML20135D701 | |
| Person / Time | |
|---|---|
| Site: | 07001426 |
| Issue date: | 01/31/1997 |
| From: | Mclaughlin J TRANSNUCLEAR, INC. |
| To: | Bennington G NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| TNY-07011-6, TNY-7011-6, NUDOCS 9703050422 | |
| Download: ML20135D701 (2) | |
Text
- _.
91 G i*- 9 7 03:10PM TRANSNUCLEAR I N C.
P01/**
O cRo3 9% l
@ vnamsNucLEAR, INC.
e January 31,1997 0@-o/4%
Mrs. Gloria Bennington Division of Safeguards and Transportation U.S. Nuclear Regulatory Commission Washmgton, DC 20555 Re:
hmuuvicar reference TNY 070116 7Cdvance notification for an impon shipment of nur.tr:ar matcrial fmm countries that are not party to the Convention on the Physical Protection of Nuclear Material
Dear Mrs Bennington:
This letter constituten Trantnuclear Inc.'s advance notification to the ilSNRP in rnmpliance with the requirements as outlined in 10 CFR 73.74 for an impon shipment of special nuclear material of low strategic significance.
Details of this shipment as required in 10 CFR 73.74(a)(3) are as follows:
73.74(a)(3)(i) Data:
i luiporter of Record Receiving Facility Nissho Iwai American Corp.
Babcock & Wilcox NNFD 1211 Avenue of the Americas Mt. Athos Road New York, NY 10036 1.ynchburg, VA 24505 212-704-6768 804/522-6000 Shipping Facility Carriers CERCA Romans Air France j
Urine des Berauds 1 Squarc Max Hymans
- p-B.P.1114 75015 Paris, France j
j 26104 Romans, France Transport Coordinator AND Transnuclear, Inc.
Tristate /Trism Four Skyline Drive P.O. Box 113 Hawilune, NY 10532 Joplin, MO 64802 914-347 2345 1-800-846-8768 a
5.Elusitypp.tlin 050092
. HAWTHORNE, NEW YORK 10532 2176
^""
"' "'" ^^"
9703050422 97013 ADOCK 0700 6
14 347 2345. FAX: 914 347 2346
{DR
UA0J7yP02/tt
- /
01-37-07 03:10PM TRANSNUCLEAR I N C.
i Page 2 of 2 TNY 97011-6 USNRC - Mrs. Bennington 73.74(a)(3)(ii) Data:
Physical description of shipment:
Maximum 20 kgs U metal enriched to 19.75% U235 loaded in 2 FS$1 packagings (USA /0162/B(U)F).
73.74(a)(3)(iii)(iv)(v) Data:
M()l)K
() K I(4 i N (ii),T K A N N F K K (T),
K()tfI'K 1)A T K f1 I M K () F A K K i V A I.
COUNTRY /ENROUTE(C/E)&
(A) & DEPARTURE (D) AT um,simA A AUW (DJ FUM I B F At M FUm 3 truck Pierrelatte, France standara truck (D) 1 cDruary 1/, iW/
0800 - 1200 hours0.0139 days <br />0.333 hours <br />0.00198 weeks <br />4.566e-4 months <br /> Paris, France Standard Truck (A) February 18,1997 0800 - 2359 hours0.0273 days <br />0.655 hours <br />0.0039 weeks <br />8.975995e-4 months <br /> i
Air Standard Air (D) February 19,1997 France (WX) - 14(X) hours j
J.F. Kennedy Int'l Airport Standard Air (A) February 19,1997 1500 - 1700 hours0.0197 days <br />0.472 hours <br />0.00281 weeks <br />6.4685e-4 months <br /> Tristate Standard Truck (D) Febmary 20-24,199/
Truck 0800 - 2100 hours0.0243 days <br />0.583 hours <br />0.00347 weeks <br />7.9905e-4 months <br /> Babcock & Wilcox NNFD Standard Tmck (A) Feb 21,24 or 25,1997 Lynchburg, VA 0600 - 1700 hours0.0197 days <br />0.472 hours <br />0.00281 weeks <br />6.4685e-4 months <br /> Arrival at the receiving facility is estimated to be between 0600 hours0.00694 days <br />0.167 hours <br />9.920635e-4 weeks <br />2.283e-4 months <br /> and 1700 hours0.0197 days <br />0.472 hours <br />0.00281 weeks <br />6.4685e-4 months <br /> on February 21, 24 or 25,1997.
This shipment will meet the levels of physical protection specified in Appendix E (Annex I).
Yours truly, Transnuclear, Inc.
h%YY Toan mci 2ughlin v
Traffic Coordinator