Forwards Final Exercise Rept for 960814 full-participation Plume Exposure Pathway Exercise of Offsite Radiological Emergency Response Plans site-specific to Plant
ML20135D371
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/08/1996
From: Elisa L
Federal Emergency Management Agency
To: Miller H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20135D354 List:
References
NUDOCS 9612090354
Download: ML20135D371 (1)


Text

.

  • .m ' '

.  ; ~2 g  ? Federal Emergency Management Agency I-' *, Region 1 LW. McCormack Post Office &

Counhouse Building, Room 442 Boston,MA 021W November 8,1996 hir. Huben J. Afiller, Administrator U.S. Nuclear Regulatory Commission, Region I 475 Allendale Road King of Pn'ssia, PA 19406 i

Dear hir. Hubert:

Enclosed is a copy of the final exercise report for the August 14, 1996, full-participation plume l exposure pathway exercise of the offsite radiological emergency response plans site-specific to the l Haddam Neck Nuclear Power Station. The State of Connecticut and the towns of Chester, l Colchester, Deep River, Durham, East Haddam, East Hampton, Essex, Haddam, Killingworth, Lyme, hiadison, hiarlborough, hiiddletown, Ponland, and Salem fully panicipated in this exercise. The final exercise report was prepared by the Federal Emergency hianagement Agency (FEhiA) Region I staff.

Copies of this report will be provided to the State of Connecticut.

There were no Deficiencies and 17 Areas Requiring Corrective Action identified during the August 14, 1996, exercise. FEhfA Region I stafTwill monitor the status of corrective actions.

Based on the results of the August 14, 1996, exercise, the offsite radiciogical emergency response plans and preparedness for the State of Connecticut and the affected localjurisdictions, site-specific to the Haddam Neck Nuclear Power Station, can be implemented and are adequate to provide reasonable assurance that appropriate measures can be taken offsite to protect the health and safety of the public in the event of a radiological emergency at the site. Therefore, Title 44 CFR, Part 350, approval of the preparedness measures for the State of Connecticut and the localjurisdictions, specific to the Haddam Neck Nuclear Power Station, granted on October 9,1984, will remain in effect, if you should have any questions, please contact Daniel McElhinney, FEMA Region I Regional Assistance Committee Chairperson, at (617) 223-9567.

Sincerely,

., Louis A. Elisa Regional Director Enclosure 9612090354 961203 PDR ADOCK 05000213 F PDR ..