.i TR-95-025 ANO Unit 2 Steam Generator Tubes:

95/95 Mechanical Properties Prepared For Entergy Operations, Inc.

By Tetra Engineering Group, Inc.

March 31,1996 758 28a s ZI88886e P

PDR

& Tetra Engineering Group, Inc.

USA: 110 Hopmeadow Street, Suite 800, Westogue, CT, 06089(1).860.651.4622 France:Immeuble Petra B, B.P. 272, 06905 SOPHIA ANTIPOLIS (33).92.96.92.54

retre eno neerse croup. inc.

e sees a nion > n: served.

u Contents introduction 1

Computational Method 2

Non-Parametric Confidence Bounds.....

2 95/95 Mechanical Propeny Values..

..2 Mechanical Property Data 3

Yield and Tensile Stress Data by SG...

.3 References 15 TR-05-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Contents e 1 i

la

Tetre Engineering Group, Inc.

c 1996 M Rights Reserved.

Introduction This report provides the lower bounds of the mechanical propenies (yield, flow, and tensile strength) for the population of tubes in the ANO Unit 2 steam generators.

These lower bounds are establishes as 95% probability /95% confidence bounds. They i

provide that at a 95% confidence, no more than 5% of the tubes will have material properties lower than these values. The bounds are computed using standard non-parametric statistical methods for confidence bounds on quantiles.

j l

]

I l

l l

i i

i l

l 1

l

)

r TR-95-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties introduction e 1 l

A - r

..,,,, o,

.,s,s n n,,,,. a..

s.

Computational Method Non-Parametric Confidence Bounds The desired values of mechanical properties are the 95% lower bound evaluated at a 95% confidence level. The most statistically conservative way to compute this is by a non-parametric confidence bound on the 95% quantile. Reference 2 provides methods 4

for both small (n<20) and large (n>20) sample sizes. Since the number of tubes in each SG is large the large sample approximation is valid.

Equation 1 shows the computation:

i r = np + w,,2)np (1 - p*)

where:

r = r th order statistic for the ascending set of material property values 1

p = the desired quantile (95% lower bound = 5% or 0.05) w,,,2 = the standardized normal deviate for probability a / 2 a = the desired two-sided confidence level (10%) for a one side level of 5%

n = the sample size (number of tubes)

This gives a one-sided order statistic of 372 for each of the ANO-2 SG's. To use this the material property value for each of the SG tubes is ordered lowest to highest. The 372"' lowest value is then the non-parametric 95/95 lower limit.

95/95 Mechanical Property Values Table I gives the resulting values for Yield Stress, Flow Stress, and Tensile Stress for each ANO-2 SG. Flow stress is determined as 0.5 times the sum of the Yield and Tensile stresses.

Table 1 95/95 Lower Bound Mechanical Properties Steam Generator Yield (KSI)

Flow (KSI)

Tensile (KSI)

A 41 67.5 93 B

40 67.5 92 l

The values are in close agreement for the two generators.

TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Computational Method 2

Tetra Engineering Group. Inc.

C1996 AlRights R: served.

Mechanical Property Data Yield and Tensile Stress Data by SG Steam Generator A YIELD STRENGTII(PSI)

TENSILE STRENGTH (PSI)

NO, 43,000 88,000 1

41,000 90,000 22 43,000 90,000 28 44,000 91,000 18 45,000 91,000 15 40,000 92,000 20 42,000 92,000 1

42,000 92,000 19 43,000 92,000 1

43,000 92,000 2

43,000 92,000 26 43,000 92,000 18 44,000 92,000 6

46,000 92,000 35 46,000 92,000 110 46,000 92,000 6

40,000 93,000 15 41,000 93,000 1

42,000 93,000 23 42,000 93,000 4

42,000 93,000 57 43,000 93,000 1

43,000 93,000 26 44,000 93,000 128 45,000 93,000 67 47,000 93,000 42 48,000 93,000 27 39,000 94,000 24 39,000 94,000 17 TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 3

'- Tetre Engheerkg Group, Inc.

C 1996 M Rights Reserved.

i (40,000 94,000 3

40,000 94,000 13B 42,000 94,000 82 43,000 94,000 53 43,000 94,000 6

43,000 94,000 71 43,000 94,000 11 44,000 94,000 8

44,000 94.000 2

45,000 94,000 152 46,000 94,000 26 46,000 94,000 28 47,000 94,000 60 47,000 94,000 4

48,000 94,000 18 40,000 95,000 11 1

40,000 95,000 33 40,000 95,000 21 41,000 95,000 3

42,000 95,000 26 42,000 95,000 133 43,000 95,000 65 43,000 95,000 78 45,000 95,000 200 45,000 95,000 23 46,000 95,000 63 48,000 95,000 21 48,000 95,000 17 40,000

%,000 1

41,000 96,000 2

41,000 96,000 89 41,000 96,000 26 j

43,000 96,000 25 43,000 96,000 20 43,000 96,000 1

44,000

%,000 31 44,000 96,000 4

45,000 96,000 24 j

47,000

%,000 1

j 49,000 96,000 222 l

39,000 97,000 2

l l

l TR-95-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 4

Tetre Engheering Group,Inc.

01996 M Rights RCserved.

40,000 97,000 1

41,000 97,000 3

41,000 97,000 6

42,000 97,000 29 42,000 97,000 2

43,000 97,000 34 43,000 97,000 132 43,000 97,000 1

44,000 97,000 78 44,000 97,000 1

44,000 97,000 91 44,000 97,000 8

45,000 97,000 1

46,000 97,000 4

46,000 97,000 18 1

47,000 97,000 108 47,000 97,000 13

)

47,000 97,000 76 48,000 97,000 66 49,000 97,000 334 49,000 97,000 1

50,000 97,000 1

42,000 98,000 1

42,000.

98,000 21 43,000 98,000 5

43,000 98,000 11 43,000 98,000 1

j 44,000 98,000 5

44,000 98,000 88 44,000 98,000 115 44,000 98,000 5

44,000 98,000 1

45,000 98,000 85 45,000 98,000 20 45,000 98,000 69 45,000 98,000 1

45,000 98,000 1

45,000 98,000 1

46,000 98,000 74 46,000 98,000 1

47,000 98,000 54 TR-05-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 5

l Tekn Ergheekg Group,Inc.

O 1996 M Rights Reserved.

47,000 98,000 9

l 47,000 98,000 6

47,000 98,000 2

l 48,000 98,000 7

49,000 98,000 7

50,000 98,000 1

43,000 99,000 8

43,000 99,000 25 44,000 99,000 21 44,000 99,000 137 44,000 99,000 59 44,000 99,000 13 44,000 99,000 21 45,000 99,000 348 45,000 99,000 87 45,000 99,000 69 45,000 99,000 40 j

46,000 99,000 183 46,000 99,000 231 46,000 99,000 1

46,000 99,000 7

46,000 99,000 3

46,000 99,000 3

]

46,000 99,000 4

)

47,000 99,000 9

47,000 99,000 46 47,000 99,000 128 48,000 99,000 93 48,000 99,000 11 49,000 99,000 42 49,000 99,000 7

50,000 99,000 10 45,000 100,000 41 45,000 100,000 105 45,000 100,000 15 46,000 100,000 2

46,000 100,000 7

46,000 100,000 3

47,000 100,000 6

48,000 100,000 1

48,000 100,000 90 1

TR-95 425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 6

TeVe Engineering Group, Inc.

01996 M Rights R: served.

48,000 100,000 15 48,000 100,000 1

48,000 100,000 16 48,000 100,000 121 48,000 100,000 6

48,000 100,000 1

48,000 100,000 87 48,000 100,000 35 49,000 100,000 74 49,000 100,000 1

49,000 100,000 1

50,000 100,000 4

50,000 100,000 8

51,000 100,000 1

51,000 100,000 12 44,000 101,000 3

46,000 101,000 91 46,000 101,000 4

46,000 101,000 72 46,000 101,000 7

47,000 101,000 103 48,000 101,000 7

48,000 101,000 10 48,000 101,000 19 48,000 101,000 4

49,000 101,000 4

49,000 101,000 1

49,000 101,000 10 49,000 101,000 102 49,000 101,000 58 49,000 101,000 2

49,000 101,000 114 49,000 101,000 34 49,000 101,000 37 49,000 101,000 1

50,000 101,000 13 50,000 101,000 1

50,000 101,000 74 50,000 101,000 8

50,000 101,000 8

50,000 101,000 114 TR-95-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 7

Tetra Engineering Group. Inc.

C 1996 M Rights R: served.

l 50,000 101,000 77 50,000 101,000 12 50,000 101,000 1

50,000 101,000 1

51,000 101,000 55 51,000 101,000 32 51,000 101,000 109 51,000 101,000 83 51,000 101,000 10 51,000 101,000 22 48,000 102,000 6

49,000 102,000 142 49,000 102,000 102 49,000 102,000 5

51,000 102,000 15 51,000 102,000 11 51,000 102,000 5

51,000 102,000 59 51,000 102,000 2

51,000 102,000 41 51,000 102,000 115 51,000 102,000 2

51,000 102,000 16 51,000 102.000 33 51,000 102,000 1

52,000 102,000 13 52,000 102,000 105 i

l TR-95-025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 8

~.

Tetra Engineering Group,Inc,

@ 1996 M Rights R: served.

Steam Generator B YIELD STRENGTH (PSI)

TENSILE STRENGTH (PSI)

No.

41,000 85,000 2

41,000 90,000 10 43,000 90,000 103 39,000 91,000 1

42,000 91,000 2

44,000 91,000 54 45,000 91,000 2

47,000 91,000 1

40,000 92,000 2

42,000 92,000 1

42,000 92,000 26 43,000 92,000 50 43,000 92,000 1

43,000 92,000 38 43,000 92,000 18 44,000 92,000 2

45,000 92,000 2

46,000 92,000 85 46,000 92,000 12 47,000 92,000 24 40,000 93,000 184 41,000 93,000 6

42,000 93,000 31 42,000 93,000 18 42,000 93,000 98 42,000 93,000 76 43,000 93,000 1

44,000 93,000 33 l

45,000 93,000 85 47,000 93,000 264 48,000 93,000 171 39,000 94,000 3

39,000 94,000 2

40,000 94,000 36 40,000 94,000 1

42,000 94,000 54 43,000 94,000 17 43,000 94,000 6

43,000 94,000 19 1R-95 025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 9

Tetra Engineering Group,Inc.

01996 M Rights Rcserved.

44,000 94,000 20 44,000 94,000 19 44,000 94,000 52 45,000 94,000 28 46,000 94,000 112 46,000 94,000 6

47,000 94,000 28 47,000 94,000 1

47,000 94/X)0 3

48,000 94,000 163 40,000 95,000 2

40,000 95,000 233 40,000 95,000 7

42,000 95,000 9

42,000 95,000 43 43,000 95,000 1

43,000 95,000 10 43,000 95,000 40

)

43,000 95,000 28 45,000 95,000 92 45,000 95,000 66 46,000 95,000 176 47,000 95,000 48 48,000 95,000 27 48,000 95,000 8

40,000 96,000 7

41,000 96,000 97 41,000 96,000 2

41,000 96,000 46 43,000 96,000 52 43,000 96,000 19 43,000 96.000 1

44,000 96,000 13 45,000 96,000 46 45,000 96,000 59 46,000 96,000 1

47,000 96,000 108 47,000 96,000 1

49,000 96,000 83 40,000 97,000 2

40,000 97,000 1

TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 10

i Tetra Engineering Group, Inc.

G 1996 M Rights Reserved.

1 l

41,000 97,000 1

41,000 97,000 2

42,000 97,000 26 43,000 97,000 28 43,000 97,000 30 43,000 97,000 1

43,000 97,000 2

44,000 97,000 49 44,000 97,000 41 44,000 97,000 47 44,000 97,000 61 45,000 97,000 4

45,000 97,000 18 97,000 20 46.000 47,000 97,000 175 47,000 97,000 5

47,000 97,000 62 47,000 97,000 2

48,000 97,000 60 48,000 97,000 2

49,000 97,000 59 50,000 97,000 2

42,000 98,000 8

42,000 98,000 1

43,000 98,000 8

43,000 98,000 2

43,000 98,000 12 44,000 98,000 40 44,000 98,000 11 44,000 98,000 4

44,000 98,000 2

44,000 98,000 5

44,000 98,000

$1 45,000 98,000 3

45,000 98,000 21 45,000 98,000 16 45,000 98,000 54 46,000 98,000 1

l 46,000 98,000 41 j

47,000 98.000 51 l

47,000 98,000 1

TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data 11

Tetra Engheerkg Group,Inc.

C 1996 M Rights Reserved.

47,000 98,000 3

47,000 98,000 2

47,000 98,000 2

47,000 98,000 1

49,000 98,000 14 50,000 98,000 19 42,000 99,000 1

43,000 99,000 28 43,000 99,000 1

44,000 99,000 86 44,000 99,000 33 44,000 99,000 49 44,000 99,000 84 45,000 99,000 79 45,000 99,000 2

45,000 99,000 44 45,000 99,000 19 45,000 99,000 6

46,000 99,000 111 46,000 99,000 75 46,000 99,000 35 46,000 99,000 1

46,000 99,000 157 46,000 99,000 1

47,000 99,000 2

47,000 99,000 7

47,000 99,000 149 48,000 99,000 9

48,000 99,000 5

48,000 99,000 184 48,000 99,000 24 j

48,000 99,000 4

49,000 99,000 4

49,000 99,000 7

49,000 99,000 13 49,000 99,000 1

52,000 99,000 21 53,500 99,600 1

44 000 100,000 17 45,000 100,000 82 45,000 100,000 11 TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 12

)

Tetra EngheerMg Croup,Inc.

01996 M Rights Reserved.

l 45,000 100,000 20 45,000 100,000 1

46,000 100,000 5

46,000 100,000 31 47,000 100,000 11 48,000 100,000 1

48,000 100,000 17 48,000 100,000 61 48,000 100,000 7

48,000 100,000 54 i

48,000 100,000 3

48,000 100,000 43 48,000 100,000 7

48,000 100,000 1

48,000 100,000 5

49,000 100,000 1

49,000 100,000 4

49,000 100,000 1

49,000 100,000 29 50,000 100,000 1

51,000 100,000 3

51,000 100,000 21 52,000 100,000 2

54,500 100,800 1

54,500 100,800 1

44,000 101,000 1

46,000 101,000 65 46,000 101,000 11 46,000 101,000 5

47,000 101,000 30 48,000 101,000 38 48,000 101,000 1

48,000 101,000 1

49,000 101,000 8

49,000 101,000 185 49,000 101,000 28 49,000 101,000 3

49,000 101,000 1

49,000 101,000 128 49,000 101,000 12 49,000 101,000 21 TR-95425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data e 13

Tetre Engheerkg Group,Inc.

@ 1996 M Rights R^ served.

49,000 101,000 13 50,000 101,000 4

50,000 101,000 37 50,000 101,000 6

50,000 101,000 3

50,000 101,000 9

50,000 101,000 1

50,000 101,000 4

50,000 101,000 15 50,000 101,000 15 50,000 101,000 1

51,000 101,000 16 51,000 101.000 2

51,000 101,000 15 51,000 101,000 105 51,000 101,000 17 51,000 101,000 163 51,000 101,000 1

48,000 102,000 34 49,000 102,000 68 49,000 102,000 16 I

49,000 102,000 4

51,000 102,000 15 51,000 102,000 230 51,000 102,000 1

51,000 102,000 18 51,000 102,000 5

51,000 102,000 16 51,000 102,000 162 51,000 102,000 9

51,000 102,000 62 51,000 102,000 1

51,000 102,000 3

52,000 102,000 102 51,000 104,000 2

54,000 106,0%

1 TR45425 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties Mechanical Property Data.14

1 Tetra Engheering Group. Inc.

C1996 M Rights R: served i

\\

References

1. D. Harrison Private Communications with F. Anderson, "ANO-2 Steam Generator Material Properties by SG and Heat, Transmittal of Spreadsheets MECHI and MECH 2", February 16,1996.
2. W.J. Conover, PracticalNonparametric Statistics, Second Edition, John Wiley s

and Sons, New York,1980.

i i

i I

l TR 85 025 ANO Unit 2 Steam Generator Tubes: 95/95 Mechanical Properties References e 15