Text

- _ - - _ - - - - - - -. - - - - - - _ _

i i

i Baltimore Gas & Electric

\\

Calvert Cliffs Nuclear Power Plant l

Unit 1 i

April 1996 Steam Generator 11 Final Reports C

050 7

C a

f i

i 4

3 CCNPP UlR12 STEAM GENERATOR MAINTENANCE PROJECT l

FTI / RTI. S.CH_E_D...U. L..E...P.E. RFORMANCE i

4

.ECT:

100% BOBBIN l

16,781 TUBES 100% H/L TTS MRPC i

16,781 TUBES U BEND MRPC 06C 06H 62 'IVBES

}

STM BLNKT MRPC 06C - 06H 937 TUBES MRPC BOBBIN 1-CODES 70 TUBES 100% MRPC DENTS

}

1,685 TUBES 20% MRPC MBMS 77 TUBES MRPC MUSHROOM 04,5,d - VM 10,036 TUBES 4

PLUGGING:

INSTALL PLUGS 1,680 PLUGS INSTALL SHORT STABILIZERS 83 STABS INSTALL LONG STABILIZERS

=

7 STAB 5 PLUG REPATR; INSTALL PAPS 133 PAPS IN-SITU PRESSURETESTING:

i

{

IN-SITU PRESSURE TEST TUBES 9 TUBES I

=

UT:

PERFORM UT ON TUBES 10 TUBES i

i I

\\

I

A l

3. ThreeLetterCodes I

Code Description ADI Absolute DriAIndication ADR Absolute Dria BDA Bad Data BLG Bulge CUD Copper Deposits i

DEP Deposit DNT Dent DNG Ding DRI Distorted Roll with a possible Indication DSI-Distorted Support with a possible Indication DTI Distorted TubesheetIndication EXP Expansion l

FIX Fixture IDC Chatter (Pilgering, ID Variations, etc.)

INC Incomplete Test INF Indication Not Found INR Indication Not Reportable LPI Loose Part Indication MAI Multiple AxialIndications MCI Multiple CircumferentialIndications MBM Manufacturing Burnish Mark M MI*

Mixed ModeIndication NDD No Detectable Degradation Some Presiousiv Used Codes NDP No Defect Found (Not to be used anymore - for historical NQ1 Non Quantifiable Indication info. only)

NRC No Roll on Coldleg (partial explansion)

APT Absolute Positive Trace NRH No Roll on Hotleg (panial explansion)

RNC Retest - Number Check NSY NoisyTube RES Restricted OBS Obstructed PID PositiveIdentification ofDefect PLG Plugged PLP Possible Loose Part PVN Permeability Variation RBD Retest Bad Data SAI Single AxialIndication SCI Single CircumferentialIndication SLG Sludge SLV Sleeve TBP To Be Plugged TBR To Be Retested TMP Template Plug TNC Tube Number Check TNT Tube Not Tested VOL VolumetricIndication

  • Note: MMI shall be used only ifit appears that the axial component and circumferential components of l

j flaws are intersecting, in essence combined to make a single flaw, 1

i i

. =

=.

l i

i i

The following outline summarizes the final results of this examination.

g e@9 % %,@$$ ag

' ' S/G 11',',' < ' ' b'

.J',

S/G 12 sal, MAI @ TTS 116 166 SCl, MCI @ TTS 56 33 VOL @ TTS 0

1 Svl @ TTS 7

7 sal, MAI @ 09H 15 5

SCl, MCI @ 09H 2

5 sal, mal, MSI - FREESPAN 164 391 PPI - FREESPAN 55 73 VOL 3

4 0-19%

129 150 20-39 %

54 90 40-100 %

8 18 TUBES REPAIRED 340 500 NOTE: Numbers denote indications. Some tubes contain multiple indications.

j l

l l

1 i

CUM' LATIVE REPORT J

04/96, BCE, CALVERT CLIFes, UNIT 1 1

STEAM CENERATOR 11 CitTAGE DATA SET PAGE:

1 0F 3

4 CURRENT DATE:

06/os/96 SELECTION VARIABLES: Indication Location, percent TIMEt 21:15:57 l

l EXAMI l

l EXAM EXTENT l l

l l

l i

l ROW lLINj CATElHEATNILEGlrROGRAMl ACTUAL lEXPl CAL lrROBEl l

LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl

-- _I _ I

- l l_._.1 1

_ I_ l -

1 l-1 L L _l_ L _1.__I i 7sl nlo4/ssi i n irza rsslrsa.rsrl locoo41sloralTsa-c.ss I o.sil l1.a ixAr lP 4 l l

1:1 22lo4/ssi i n irsa.rsattss-rsal loooo7lslornlTsu+ o.as l 1. col lo. IsAzlP 41 1

6 26l 22lo4/ssl l B lTsB-TsEjTsH-Tsu) joooo7l slope lTsH+ o.11 l o.7sl lo.2lsAIlP el j

n ) 23lo4/ssl l m Irsa-rsairsa-rsal loobosis1oraltsa+ o.1s i 1.col lo.2lsAIlP 1l l

. s41 32lo4/ssl 1 m lesa rsnIrss-rsat tooalslslornirsn. o.se l o.s4l lo. Isulr 1l l

12l 44to4/ssl

\\ E lTsH-TSBlTsH-TsB) l coo 27ls1hrsirsa+ o.1s l 1.26l lo.2lsAIjP lj j

<s) solo 4/ssl s Irss-rsairsa-rsHl l coo 37lsloPHlTsa+ o.78 l o.8sl lo.sjsAIlP 4l l

41l 53lo4/s6l' l M lrsE.TsnlrsE-TsBl l coo 4 lsloralisa+ 0.4s l o.57l lo.2lsA2{P 4l

}

471 s3lo4/ssl

{ E lTsE.TsBlrsH-TsEl loco 44]slorHlrsa+ o.s1 l 0.ss) lo.8lsAIjP 4l l

4sj s4lo4/ssl l C lrsH-rsajTsE-Tss!

l coo 44lsiorHjrss+ o.ss l o.82l lo.2lsAIlP 4) l

.si selo4/ssi I a Irsa.rsairsa rsal locos Isterstrss+ o.72 l 1.14l lo.slsAzlP at l

sol s4lc4/sst

!2 lTss.TsslTsa-Tsnl looo44lsioraliss+ o.s2 I o.s4i to.4tuzlP 41 l

l lo4/ssi

, a irsa-rsairsa-rssl looo441storattsu+ o.ss I o'.ssi lo.sixAtle 4l l

231 ssio4/ss!

1 a ITsa-rsslrsa-tsal loco 4sistorntrsu+ o.1s I o.ssi io.21sArtP 41 1

471 ssio4/sst i a]Tsa.TsslTsaTsul loco 4sislornirss+ 1.ss i o.701 lo.2ixxxtP al l

l lo4/ssi

a irss-rsnlrsa.rsal looo4stslorslrss+ 1.sv l 1. n l lo.2]xule 21 l

491 ssio4/ssi i a irss-rsslrsa.rsxl looc4sislornirsn. o.as

( c. sol lo.41 mIlP 4l l

1 tc4/ss!

! s lTss-Tssltsu-Tsat loco 4ststorntrsu+ o.ss I o.ssi lo.sinuly 41 l

s11 ssjo4/ssi

! n Irsu-Tsslrss-rsal loco 4sistoralzsu. c.se I o.s41 lo.41xulP <!

l 1

lo4/ssl 1 s Irsa.rsaltsu-rsal loco 4slslornlrsa+ o.se I o.4sl lo.slxult 41 I

sai sslo4/ssi i n ITsu-TsalTss.Tsnl looo4sislornlrsu+ o.43 i o.sil l.21sAtle 41 1

4sl ssice/ssl t n lrsa.rsslrss-rsal loco 4slsloralrsn. o.s2 i o.22 lo.3lxAz\\P 2l l

l lo4/ssl f n Irsa.rsairsa.rsal loco 4ststorstrsa. 1.as i o.4ol lo.aixAzlP 21 1

est ssto4/ssi i u ITsa-Tsultsu-Tsnl loco 4sistoralisu+ o.ss i o.asi lo.4}xAzlP 41 l

l lo4/ssi I a lisa.rsaltsa.rsal loco 4sislerslrsn+ 1.n I o.7sl lo.sinulP 4l l

17l s7lc4/ssl lH lTsH-TsHlTsH-rsHl l coo 4slslorHlrsH+ o.4o l o.sel lo.sjnA2lP 4]

l 1

1o4/9s1 i u ITsa.'Tsalvsu-tsni looo4sisterairsu+ o.41 I o.341 lo.sinulP 41 l

571 57 l o4 /ss l t a Irsa.rsslrsa.rsal looe4sistornlisu. o.7s i 1.1sl lo.slxAIlP 4) l l

1o4/9sl a Irsa-rsairsa.Tsal lccessistorattsu+ o.so I c.svi lo.sinArlP 41 l

2c] s8Ic4/ssl H lTsa-TsEITsH.TsH) loco 4sjslorHlTsH+ o.21 l o.8sl lo.3\\sAllP 4) l 32l 5 slo 4/ssl l B jrsa-TsalrsH.TsHl lcoceslslorHlTsH+ o.1s l o.8sl lo.2lsAllP 41 l

n i selo4/ssi i n irsa.rsslrsa-rsal looo4sistcruirss+ o.7s I o.4sl lo.sisAllP 41 1

al sslos/ssi i a itsu.TsalTsa.Tsul looo47lslorstrsa. o.2s l 1.1st to.sixAstP 4]

1 l

lo4/ssl l a lrsR-TsElrsH rsEl l coo 471slorHlTsH+ o.27 l o.s2l lo.4lxAllP 4l l

1st ssio4/ssl I s Irsu.rsstrsa rsal looc4elslorslrsa+ o.17 I o.ssi lo.sixAxlP ti i

}

lo4/ss{

l B lTsH TsHlTsa.rsal looo4sistorHlrsu+ o.2o l 2.sel jo.71xAIjP 4]

]

ni solo 4/ssi l n lrsa.rsairsa TSHl l coo 47lsloPHlTss+ o.32 l 1.oBl lo.sixA1lP 4l l

l lo4/ssi j a irsa.rsslrsa.rsal looo47tstorslTss+ o.41 I c.7sl lo.sixAzlP 41 l

231 solos /ssi t a (Tss-Tsatrsa.Tsal looessistorstrsu+ o.2s l 1.14l lo.sisAllP el 1

asi solo 4/ssl l a Irsa.rsslrsa-rsal looo47lstornirea+ o.14 I o.7ol lo.2lSA1lP 4l l

ssi solo 4/ssi i a irsa-rsnlrsa-rsal loco 4sistorntrsn* o.54 l o.4aj to.sixulP 41 1

I

]c4/ssl t a iTsu-TsnITsa Tsal locoaststorstrsa+ o.ss I o.esi lo.simulP 41 1

41 solo 4/ssi I a irsa-Tsnirse-rsal loco 471sloruirsa. o.s7 l c.7sl lo 7lsAllP el i

14] solo 4/ssl l a (TsH-rsnlTsB.Tsal loco 48lsiorHlTsB+ o.2s l o.s7l lo.sjsAIlP 4l l

541 solo 4/ssi 4 n ITsa-TszlTsa.rsal looo4sistornitsa+ o.62 I c.ssl Io.41sAzte 4l l

_i_ l-I l_1

]

l_1 1

I I

l _ L._. I _ l- _ L_.__ I ROCKRIDGE TECnNOLOGIES

I CUMULATIVE REPORT l

04/96, BCE, CALVERT CLIFFS. UNIT 1 STEAM GENIRATOR s 11 f

DtJTAGE CATA SET CURAENT PAGE:

2 OF 3

DATE:

06/05/96 SELECTICN VARI ABLES : Indication Location, Percent TIME:

21:15:57 I

l l

IXAM]

l l EXAM EXTENT l l

l l

l l

l l ROW lLIN ~~ ATE l HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS lM:LlDEGl 1 lCH lCHNGl l_I_

i L__. I I

l_I I

I I

l _.l _ I_ l-_i _ I l 56l 60 04/96l lH lTSH-TSHlTSH-TSHl l00047l610PHlTSH+

0.57 l 0.76l

[0.3lMAIlP 4l l

l l

C4/96l l H lTSH-TSElTSH-TSHl l00047l610PHlTSE+

0.94 l 0.39l l0.4lMAIlP 4l l

l 17l 61 04/96l lN lTSH-TSHlTSH-TSEl l00047l610PHlTSE+ 0.20 l 1.04l l0.4lSAIlP 4l l

l 10] 62 04/96l l H lTSH-TSHlTSH-TSHl l00648l610PHlTSH+

0.23 l 0.59l l0.3lSAIlP 4l l

l 24) 62 04/96l lE lTSH-TSHjTSH-TSHj l00047l610PHlTSH+ 0.22 l 0.76l l0.3lSAIlP 4l l

l 18) 64.04/96l l H lTSH TSHlTSH-TSEl l00054l618PHlTSH+

0.23 l 1.26l l0.3lSAIlP 4l l

l 46l 66 04/96l l H lTSH-TSBlTSH-TSHl l00059j610PHlTSH+

0.24 l 2.68l l0.5lSAIlP 4l l

l 54] 74 C4/96l lH lTSH-TSalTSH-TSHj l00061l610PHlT8H+

0.69 l 1.10l l0.3lSAIlP 4l l

l 70l 78 04/96l lH l tau-TSHlTSH-TSHl l00063l610PHjTSE+ 0.52 l 0.60l l0.2lSAIlP 4l l

l 71] 81 C4/96i l H lTSH-TSBlTSH-TSHl l00065l610PHlTSq+

0.68 l 0.99l l0.2lSAIlP 4}

l l 70l 82 C4/96) l H lTSH-TSHlTSH-TSHl l00063l610PHlTSH+

0.22 l 0.72l l0.3lSAIlP 4l l

l 75l 83 04/96l lH lTSH-TSHlTSH-TSHj l00062l610PHlTSH+

0.35 l 1.82l l0.6lMAIlP 4]

l 1

l 04/96l lH lTSH-TSHlTSH-TSHl l00062l610PHlTSH+

0.89 l 1.75l l0.3lMA1(P 4l l

l l

04/96l lH lTSH TSHlTSH-TSHj l00062l610PHlTSB+

0.90 l 0.73l

[0.5MAIlP 4l l

} 70) 84 04/96l lH lTSH-TSHlTSH-TSHl l00062l610PHlTSH+

0.23 l 1.12l 10.2'MAIlP 4l l

l l

~4/96l lH lTSH-TSHlTSH-TSEl l00062l610PRlTSH+

1.06 l 1.29l

[0.5 MAIlP 4l l

4 72) 84 04/96l lH lTSH-TSHlTSH-TSHl l00062l610PHlTSB+

0.50 l 1.28l l0.6!MAIlP 4l l

l l

4/96l lH lTSH-TSHlTSH-TSHj l00062l610PHlTSH+

0.84 l 2,11l l1.5;MAIlP 4 l l

l 74] 04 04/96l l H lTSH-TSHlTSH-TSHl l00125l610PHlTSH+

0.43 l 0,84l l0.5lSAIlP 4l l

4 78l 84 :4/96l l H lTSH-TSElTSH-TSEl l00062l610PHlTSH+

0.67 l 1.36l l0.7lSAIlP 4l l

l 71l 85 ;4/96l lH lTSH-TSHlTSH-TSHl l00066l610PHlTSH+

0.38 l 0.36l l0.71MAIlP 4l l

l 04/96l lH lTSH-TSHlTSH-TSEl l00066l610PHlTSH+

0.39 l 0.53l l0.5lMAIlP 4l l

60} 86 ~4/96l lH lTSH.TSHlTSH-TSHl l00139l610PHlTSH+

1.02 l 0.55l l0.5 SAIlP 4l l

1 l

04/96l l H lTSH-TSHlTSH-TSHl l00139l610PHlTSH+

1.34 l 1.33l l0.3(SAIlP 4l l

l 70l 86 ~4/96l lH lTSH-TSBlTSH-TSHj l00066l610PHlTSH+

0.14 l 1.00l l0.3 ;MAIlP 4 l l

l

~4/96l lH lTSH-TSHlTSH-TSHl l00066l610PHlTSH, 0.36 l 1.02l 10.9;MAIlP 4l l

l 59l 87 24/96l lH lTSH-TSHlTSH-TSHj l00139l610PHlTSH+

0.13 l 0.34l l0.4lSAIlP 4[

l 69l 87 04/96l lH lTSH-TSHlTSH-TSHj l00066l610PHlTSH+

0.58 l 0.41l l0.3iSAIlP 4l l

i 71l 87 04/96l lH lTSH-TSHlTSH-TSHl l00066l610PHlTSH+

0.46 l 0.69l l0.8'MAIlP 4l l

l

~4/96l l H lTSH-TSHlTSH-TSHj l00066l610PHlTSH+

0.79 l 0.98l l0.7;MAIlP 4l l

73l 87 04/96l lH lTSH TSHlTSH-TSHl l00066l610PHlTSH+

0.41 l 3.25l i

l0.S MAIlP 4 l l

i

?

l 04/96l lE lTSH-TCHlTSH-TSHl l00066l610PHlTSH, 0.59 l 0.97l l0.5:MAI]P 4l l

l

~4/96l lH lTSH-TSHlTSH-TSHl l00066l610PHjTSH+

0.61 l 0.41l l0,5lMAIlP 4l l

i 1 77l 87 04/96l lH lTSH-TSHlTSH-TSHl l00066l610PHlTSH+

0.90 l 1.221 l1.ClMAI{P 4l l

l l

04/96l lH lTSH TSHlTSH-TSHl l00066l610PHlTSH+

1.02 l 0.48l

[0.6lMAIlP 4l l

l 79] 87 ~4/96l lH lTSH-TSHlTSH-TSHj l00066l610PHlTSH+

0.57 l 0.55l 10.3lSAIlP 4l l

} 76] 90 04/96l lH lTSH-TSHlTSH-TSHl l00070l610PHjTSH, 0.34 l 0.36l l0.7lMAIlP 4l l

l

4/96l lH lTSH-TSHlTSH-TSHl l00270l610PHlTSH+ 2.61 l 0.58l l0.7lMAIlP 4l l

i l

4/96l lH lTSH-TSHlTSH-TSHl l00070l610PHlTSH+

3.89 l 0.39l l0.3IMAIlP 4l l

78l 90 04/96l lH lTSH TSHlTSH-TSHl l00072l610PHjTss+

1.47 l 0.60l 10.5lMAIlP 4l

[

l l

04/96l lM lTSH-TSHlTSH-TSEl l00070l610PHlTSH+

1.49 l 0.44l l0.3lMAIlP 4l l

67] 91 24/96l lH lTSH-TSHlTSH-TSHl l0f071j610PHjTSH+

0.48 l 1.30l l0.4lMAI[P 4l l

l 04/96l l H lTSH{fSHlTSH-TSHj l00071l610PHjTSH+

0.50 l 0.63l l0.5lMAIlP 4l l

l 04/96l lH lTSH.TSHlTSH-TSHl l00071l610PHlTSH+

0.51 l 0.72l

[0,5lMAIlP 4{

l i

! 71l 91 04/96l l H lTSH-TSHlTSH-TSHl l00071l610PHlTSH+

0.61 l 5.32l l0.5lMAIlP 4l l

t__ L_

1 L__ t I

l __ I I

I I

l_ I_!_I__ l_1 ROCERIDGE TECHNOLOGIES

(

- - ~... -

-_.-------..n..-.,

- - -.~.. - - -.. ~ - -

.~._~

.,~-

. -, ~.. ~.

CUMULATIVE ttEPORT e4/96, BGE CALVERT CLIFFE. UN!r 1 STEAM CENERATOR t 12 PAGE:

3 OF 3

OLTTAGE DATA SET CURRENT DATE:

06/o5/96 SELECTION VARIABLES: Indication Location, Percent TIME:

21:15:57 I

I

.I 1 ExAMI I

I EXAM EXTENT l l

l 1

I l

ikOwlLINI DATElHEATsjLEGIPROGRAMI ACTUALIExPl CAL l PROBE l LOCATION lVOLTsjMILlDEGl% lCH lCHNGl l_l_l l

l-._

I l

L- !

I i

1 L_t _._l t

_L.__ I I

I I

los/esi l m Irsa rsslrsa-rssi loco 71lstoraltss+ o.s7 l 4.22l to.stmarle 4l l

l I ni ulos/ssl l u lrsa-rsslrss-rssl loco 7Istormirss+ o.so l o.7sl lo.4tuazte 4[

t I

l los/nl I a irsa rsairsa-rssi loco.n j storslrss+ o.so I o.74l lo.4lmarle 41 l

1 l

lo4/ssi I a irsa-rsaltss-rsal loso72lstorstrsa. o.st I a.est to.slmarte 4l t

I ni nion/nl I a irss-rsultss-rssi loco 721ssoenirsu+ o.22 l 2. sat to.stmaxlp 4l 1

i l

l 1

lo4/nl I a less-rsairsa-rsal looo721s2.cenirss+ o.ss I o.ul lo. lmazl, 4l t

I voi nios/nl l n irss-rsaltss-rssi locotsistorslrss+ o.ss l 1.osi lo.simaz(e 41

(

l I

lo4/ssi l u lrsu-rssjrsa-rsal loco 7sisternetsu+ o.7s

-l 1.e41 lo.4lmarle 4l l

1 nj nles/nl 1 m Irsa-rsnjrsa-rssl loco 721storslrss+ o.42 I o. sol lo.7lsAz(e 41 1

l lust ulos/nl l u less-rsnlrss-rsal loo 24 s t storslrs,n-c.ss l o.e4l lo.7lsAzte it t

(

l i

los/nl l n irsu-rsslrss-rsal loo 24sisterairsa-o.se 1 a. sal lo.sjsAxlp-ti l

'I set nio4/nl 1 x lrsa-rsslrsa-rsul locotslssoraltss+ o.s2 l o.ssi lo.sisA!le 4l l

I of njos/ssi l u less-rsujrsa rssi loootslstorairss+ o.se i o. sot i.sisA21e el l

1 l 7elzoolo4/nl l x lesu rsnlrsa-rsxl looonistereirss+ o.is I o.s71 lo.sluasle 4l l

I saisosjo4/n l I n irsu rsslrsu-rsal loonsistorstrsa+ o.n I c.nl I.ssisule 41 1

l 561uolo4/nl I n irsu rsnlrsu-rsal lconsistornirsa+ o.so I o. sol I.ssjsule el I

I s21 u 2lo4/ n l I u irsu-rsnlrsa-rsal lool:71ssornirss+ o.ss

( o.7tl lo.stsAIle 41

)

[

l s4l1121o4/esl l H lrsH-rsHlrsH-TsEl l0o137lslorHlrsH+ o.45 l 0.41l lo.2lMAlle 4l l

l 1 saluelo4/nl 1 a Irsn-rsultsu-rssi lootssistornirsu+ o.4s I o.sil lo.stsizie 41 I

i I

los/nl I n Irsa-rsultsu-rsal loonsistcruitsn+ o.ss l o.sel lo.4lsAIte 4l l

i o lusio4/ssi l n Irsa-rsnlrsa.rsal loonsinosaliss. o.n I o. sol lo.2lsArte 41 l

i t

i siluslos/nl I a irsu rsalesu-rsal loo 127lstoralesH+ o.64 l o.ssl jo.21sAZIP 4l l

l 1 salusio4/nl i n Irsa-rsultsu-rsal loot:71storstrsa+ o.34 1 a. sal lo.21sarle el l

l solt2clo4/nl I a Irsu-rsuitsn-rsal loonalnoralrss+ o.2o

( o.nl l.41sAxle 4I I

l 2sl141lo4/s6l lH lTsH-TsHlrsH TsEl lcolo4lslePHlrsH+ o.le j o.3sI jo.2lsAIlr 4l l

{

l unsolo4/nl l u lrsa.rsnlrsa-rsal footo71siornirsu. o.2s 1 2.asi lo.sjsAzle 4l l

L.-.I _ i i

I _.1_ _ i L.- I I

I I

L.__L._ L l

_l _ i NUMBER OF TUBES SELECTED FROM CURRENT OITTAGE:

80 NUMDER OF DATA hECORDS SELECTED FROM CURRENT OUTAGE:

lit f

NO TRED ANALYSIS REQUESTED h

l DATA sILECTION CRITERIA:

Indica-ion Location: TSH -1.oo to TSH +5.co Percenti MA1,SAI 1

1 REPORT OPTIONS Only examination results matching criteria are included i

i l

l l

ROC 3tRIDCs rsCENOLOGIEs

(

i l

l t

I

CUMULATIVE REPORT 04/96, BCE, CnLVERT CLIFFS, UNIT 1 STEAM GENERATOR

Il PAGE 1 OF 2

OUTAGE DATA SET

  1. CURRENT DATE:

Os/05/96 SELECT!ON VARIABLES: Indication Location, Percent TIME:

21:57:50 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lL:Nl DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l IDCATION l VOLTS l MIL lDEGl t lCH lCHNGl l _ I __. l l

l_I I

l_l l

1 I

l-_-.l_I_I_ L_ I l s2l 44l04/9sl l N lTSu-TSHITSu-TSHI 10002els10PHlTSn+ 0.14 l o.s3l l1.tlSCIIP sl l

l 91l 45l04/9st lH lTSn-TSHITss-TSHj l00027ls10PnlTSn. 0.13 l 0.sil l1.0l SCI lP 51 l

l s0l 4sl04/9sl l H lTss TSnlTSn-TSsj l00035ls10PHITSH+ 0.15 1 0.37l 10.2lSCIIP 51 l

l e2l 4sl04/9sl l H lTSn TSHlTSu-TSHI l00b35lsioPBlTSE+ 0.33 l 0.75l l0.3l SCI lP 5l l

l 75l 47104/9st lE ITsu-TSulTsa-TSal l00035lsiOPHITSn.

0.14 1 1.101 10.slSCIIP 5l l

l 79l 47104/9s1 l u lTSH-TSalTSa-TSal 100035lsibPnlTSn.

0.09 l 0.711 10.sl SCI lP 5[

l l e51 47l04/9sj l n ITSa-TSHITsu-TSHI lo003 sis 10PslTss+ 0.04 l o.7ol lo.4lSCIIP 5l l

l 911 47104/9sl l H [TSH-TSHITSa-TSul 100125lsioPalTSH. 0.cs 1 0.4sj l0.3lSCIIP 51 l

l ol 4sl04/9sl l H lTSH-TSalTSu-TSHI lCo0351s10PHITSH+ 0.12 l 0.s51 l0.3lSCIIP 51 l

l Ssl 48l04/9sl l N lTSH-TSHlTSH TSHl l00035ls10PHjTS3+

0.14 l 0.78l l0.5lSCIlP 5l l

l s7l 49l04/9sl lH lTSH-TSElTSE-TSEl l00038lsiOPHlTSE+

0.09 l o.s9]

l1.4l SCI lP 5l l

l sil 51104/9si l H lTSu-TSHITSa-TSHj lDo041ls10PHlTSH+ o.15 l 0.50l l1.3lSCIIP 5l l

l 60) 52l04/9st lH lTSH-TSnlTSH-TSal l00o42ls10PHITSH+ o.07 l 0.50l l0.4]SCIlP Si l

l ssl 52104/9sl lM lTSH-TSHjTSH-TSBl l00041ls10PHlTSH+ 0.07 l 0.s0l l1.0l SCI lP 5l l

l 72l 52!04/9sl lH lTSH-TSHlTSH-TSHl l00042ls10PHlTSH+

0.21 l 0.40l l0.3l SCI!P Sj l

l 87l 53104/9sl lH lTSH-TSHlTSH-TSEl l00044ls10PHlTSH+ 0.Os l 0.70j l0.4l SCI]P 5l l

l 97l 53l04/9sl lH lTSH-TSHlTSH-TSHj l00043ls10PHlTSH+ 0.04 l 1.44l l0.9l SCI l 2]

l l s4l 54 iO4/9sl l H lTSH-TSHlTSH-TSHl l00043ls10PHlTSH+

0.11 l 0.74j l0.2l SCI lP 5l l

l 70l 54104/9sl l H lTSH-TSHlTSH-TSHl l00044ls10PHlTSH+

0.01 l 0.89l l1.3l SCI lP $l l

l100l Ssle4/9si l H lTSH-TSHjTSH-TSHl l0004sist0PHlTSH+ 0.Os l 0.58l lo.8l SCI lP 5l l

l 19l 59104/9sl lH lTSH-TSHITSH-TSHI l0004 sis 10PHITSH+

0.03 l 1.57l 10.9lSCIIP 5l l

l s9l 59!04/9sl l H lTSH-TSHlTSH-TSHj l00045ls10PHlTSH+

0.10 l 0.87l l1.0l SCI lP 5l l

l 4l sol 04/96l lH !TSH-TSHlTFH-TSHj l00047l610PHlTSH+

0.04 l 0.98l l0.5l SCI lP $l l

l 1sl 60104/9sl lH lTSH-TSHlTSH-TSHl l00047ls10PHlTSH.

0.03 l 0.51]

l0.5l SCI lP 51 l

j l 15l s1:04/9sl l H lTSH-TSHlTSH-TSBl l00048ls16PHlTSH+ 0.12 l 3.4sj l1.0l SCI lP 5l l

l s3l s1,04/9sl lH lTSH-TSHjTSH-TSHl l00043ls10PHlTSH+

0.04 l 0.90l lo.7lSCIjP 5l l

l 73l si;04/9sl lH lTSH-TSHlTSE-TSHI l00047ls10PHjTSH+ 0.11 l o.3sl l0.4l SCI lP Sj l

l 18l s2104/9sl

}H lTSH-TSHlTSH-TSHj l00125ls10PHlTSH-0.01 l 0.92l l0.5lSCIjP $l l

l s3l s5!04/9sj lH lTSH-TSHlTSH-TSHl j00055ls10PHlTSH+

0.09 j 1.s2l l0.8l SCI lP Si l

l 27l s7'04/9sl lH lTSH-TSHlTSH-TSHj l00058ls10PHlTSH+

0.04 l 2.47l l1.sjsCIlP 5l l

l vil s7,04/9sl lH lTSH-TSHlTSH-TSHI l00059ls10PHITSH+ 0.05 l 2.12l 11.4lSCIIP 5l l

l 1sl s4,04/9sl lH lTSH-TSHlTSE-TSHj l00058ls10PHlTSH+ 0.07 l 0.80l l1.0l SCI lP 5l l

l 39l s9l04/9sl lH lTSH-TSHlTSH-TSHl l000stls10PHlTSH+ 0.03 l 0.55l l0.5l SCI lP 5l l

l 77l 71!04/9sl lH lTSH-TSHlTSB-TSHl l000s0ls10PHlTSH+

0.10 l 1.15l l0.Sl SCI lP 5]

l l 52l 74104/9sj l H lTSH-TSHITSs-Tsal l000s0ls10PHlTSH+

0.34 l 1.02l lo.5l SCI lP 5l l

l 52l 7sjo4/9sl l H lTSH-TSHjTSE-TSEl

\\000s2ls10PHlTSH+

0.04 l 0.43l l0.3l SCI lP 5l l

l 72] 1s104/Ssl l N lTSH-TSHlTSB-TSHl l000s2ls10PHlTSE+

0.00 l 1.14l l0.7l SCI lP 5l l

l sal 7s!O4/9sl l H [TSH-TSHITSH-TSHI l000s2ls10PHjTSH+

0.0 i 0.s2l lo.3l SCI lP 5l l

l 74) 7sl04/asj lH lTSH-TSHITSu-TSHI l000s3ls10PHlTSH+ 0.Os l 0.72 l lo.2l SCI lP 5]

l l 72l e0104/9sl l H lTSu-TSHITsu-TSal l000s4ls10PHITSa+

0.07 1 0.7sl 10.7lSCIIP W l

l 74l 80iO4/9sl lH lTSH-TSRlTSE-TSHj l00125ls10PHlTSE. 0.03 l 0.s2l l0.sl SCI lP 5l l

l 411 sl O4/9sl l H lTSH-TSHITSs-TSHI l00143ls10PHlTSa+

0.00 l 1.0sl li.OISCIIP 5l l

i l 53l 83104/9sl lE lTSH-TSHlTSE-TSEl l00151\\500DPlTSE+ DA4 l 0.54l l0.4l SCI lP 5l l

l 72l 84104/9sl lE lTSH-TSHlTSB-TSEj l000s2ls10PHlTSH+ 0.10 l 0.44l l0.2l SCI lP 5l l

l 44l 9el04/9si lH lTSH-TSHlTSu-TSBl l00134ls10PHjTSH+

0.37 l 0.s1l l0.2l SCI lP 5l l

1._ l _ !

l l_1 I

l_I l

l 1

l___l _l-__l_._l _ I ROCKRIDGE TECHNOLOGIES

-.~.

CUMUIATIVE REPORT 04/06, BCE, CALifERT CLIFFS, UNIT 1 STEAM GENERATOR r Il OUTAGE DATA SET PAGE:

2 OF 2

CURRENT SELE CION VARIABLES: Indication location, Percent DATEt 06/05/96 TIMEt 21:57:50 l

i l EXAM]

l l EXAM EXTENT l l

l j

l lRnWi".INl DATEl HEAT #l LEG l PROGRAM l ACTUAL (EXPl CAL lFROBEl l

j LOCATION

} VOLTS l MIL lDEGl % lCH lCHNGl l _ L_._ l l-l_l

.I 1

_l l

I I

L L._L_I_ _1 _ I

{ 28i102l04/96l l M lTSE-TSHlTSH-TSHj l 00114 l 610PElTSE4 0.01 l 0.67l l0,7l SCI lP 5l l

l 38j104l04/96l lN lTSE-TSulTSE-TSal l 00114 l 610PElTSE+

0.09 l 0.68) 10,5l SCI lP 5l l

l 21l107l04/96l l H lTSH-TS"lTSE-TSEl l00112l610PElTSE+

0.18 l 0.44l l0.5l SCI lP 5l l

l 84l110l04/96l l E lTSE-788lTSE-TSEl l00'081l610PElTSE+

0.04 l 0.64}

l0.4l SCI lP 5l l

l118!110j04/96) l E lTSE-TSElTSH-TSEl l00123l610PH(TSH+

0.06 l 0.64}

l0.3l SCI lP 5l l

} 81l111l04/96l l B lTSB TSElTSH-TS8j l00081l61tPE(TSE+

0.09

) 0.67)

}.4l SCI lP5 l l

l 60!114l04/96l l B lTSE-TSElTSH-TSEl l00137l610PElTSE+

0.05 l 0.56]

l0.4l SCI lP 5l l

l 92:116l04/96l l H lTSE-TSH]TSH-TSH)

} 001241610PB j fSE+

0.06 l 0.59l l0.2l MCI l 2l l

l 56 118[04/96) l B lTSH-TSRlTSH-TSBl l00138l610PHlTSH+

0.05 l 0.91l l.47} SCI lP 5l l

l 90l118l04/96l lH lTSH-TSHlTSH-TSHl l 00087 l 610PHlTSji+

0.07 l 0.86l l0.6] SCI l 2l l

j

{

l 66 136l04/96l l H lTSH-TSHjTSH-TSHj l00092l610PEj7SH+

0.12

[ 0.53l

{ 0.2lSCIj P -5) l l___ _ I I

L_.I i

L_.I i

1 I

l_ I_ l-._.L _I_ l NUMBER OF TUBES SELECTED PROM CURRENT OUTACE:

56 NUME!!. OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

56 NO T72ND ANALYSIS REQUESTED DATA 5 ELECTION CRITERI A:

\\

Indi:s:lon Location: TSH -1.00 to TSH +5.00 Perce.. : MCI. SCI i

REPOE OPTIONS Only examination result s matching criteria are included i

I i

i I

J POCKRIDGE TECHNOLOGIES 0

(

(

CUMULATIVE REPORT o4/ss, BGE, CALVERT CLIF'Fs, UNIT 1 STEAM GENERATOR

11 PA;Ei 1 OF s

OUTAGE DATA SET

CURRENT DATE:

06/05/96 SELEC" TION VARIABLES: Indication Location, Percent TIME:

22:33:48 i

I l Ex^MI l

l EXAM EXTENT l t

l 1

i (RowlLINl DATsl HEAT #l LEG l PROGRAM l ACTUAL lExPl CAL l PROBE l l

LOCATION l VOLTS lM ~.~. lDEG; % lCH lCCi3l l _---- l __ t I

l_i i

_ l_l -

l 1

i L_L._ _ l __ l _ l l 75l 1sjo4/ssl l H lTEH-TsHlTEH-TsEl l0 coo 4l slop 8lTsH- 0.s5 l o.51l l1.2'MAIlP 41 l

l 1sl 221e</ssl l n ITsu-TsHITsH-Tsul loooo7lsioPslTsH+ o.as l 1.0ol lo.rsulP 41 l

1 ast 22io4/ssl

) a lTsa.TsslTsu-TsHI loooo71sioPaltsa+ o.11 l o.7sl lo.2'sAz tP 41 l

l 17l 23lo4/ssl lB lTsH-TsHlTsH-TsBl l c o'c os j s1oPHlT,sH+

i o.15 l 1.ocl lo.2!sAZjP 1]

l 1 s41 32lo4/ssi i a ITsH-TsnlTsa-Tssl loco 13lsioPnlTsa+ o.se l o.sel lo.3 su tP 11 1

i 121 44to4/ssl l a lTsH-TsslTss-TsHl l coo 27lsibPalTsa+ o.1s i 1.asi Io.2 sulP 11 l

} s2l 44lo4/ssi l a iTsa-TsnlTsa-TsHl l coo 2sislePslTss+ o.14 l o.ast 11.1 sezlP si l

l s1l <sto4/ssi l a ITsa-TsultsH TsHl i coo 27 l slePnlTs' H+ o.13 I o.s1l l1.o-serlP si l

1 i sol eslo4/ssl lH lTsH-TsalTss-TsHI loco 3sisloPHITsa+ o.1s I o.271 lo.2 sczlP si l

)

1 sal 4 slo 4/ssi lH lTsH-TsulTss-TsHl looo3slsioPalTsH. c.33 i c.7sl 1o.3 seslP st 1

l 75l 47lo4/ssl lB lTSH-TsHlTsE-TsHl looo35lsloPHlTSH+ 0.14 l 1.101 lo. sC1]P 3) l 1 vsl 47lo4/ssl l n ITsH-TsHITsa-TsHI lo0otsisloPHlTsH+ o.os I c.711 lo.s serlP st i

1 es) 47to4/ssi i H trsH-TsnlTsu-TsHl jooo3slsioPHITsH+ o.c4 l o.7ol lo.4 sextP si j

j ell 41lo4/es]

lE lTsH-TsHjTsH-TsHl lo0125lsloPHlTsH+ o.o6 l o.4s; lo.3 sCIlP sl l

l 2ol 4 slo 4/ssl t a ITsH-TsalTsH TsHl lcoessisloPHITsH+. c.12 I c.ssi 1o.3 scstP si l

l 5sl eslo4/ssl lB lTsH-TsHjTsH TsHl l coo 3slslePHlTsH+ o.14 l o.7sl lo.s sCIlP sl l

l s71 < slo 4/sst

!H ITsH TsHITsH-TsHI loco 3sisioPHITsH+ c.os I o.ssl 11.4 scIIP si l

l 4sj Soto4/ssl lH ITsH-TSHlTsH-tsH) looo37]sloPHlTsH+ o.7s l o.asj

!c.3 sAI(P ({

l i ell s11c4/ssi lH ITsH-TsHlTsH-TsHI loco 41ls10PHITsH+ o.is i o. sol 11.3 scrip st l

)

l sol 53lo4/ssl l a ]TsN-TsHjTsH-TsHl loco42lslePH[TsH+ o.o?

I c. sol 1o.4 sC1lP sl l

l ssl s2lo4/ssi i n lTsH-TsHITsH-Tsal loco41lsioPHITsH+ o.ov l o. sol 11.o sezlP sj i

l 721 52lo4/ssl lN lTsH-TsHlTsH-TsHl l00042lsloPH(TsH+ o.21

( o.40l lo.3 SCI {P 5l l

i 41l 53lo4/ssi i H lTsH-TsHITsH-TsH) looo431stoPHITsa+ o.4s I o.s7l lo.2 sArlP 4I i

j 1 47l 53to4/ssi I a ItsH.rsHITsH-TsHl looo441sloPHITsu+ c.s1 i c.ssi to.s sAtlP 41 l

l s7l 53lo4/ssl lH lTsH-TsHlTsH-TSHl l0eo44lslePHITss+ o.os l o.7ol lo.4 sCIlP 5]

}

l e7] 53lo4/ssl lH !TsH-TsHlTsH-TsHj jooo43lsloPHlTsH+ o.c4 1 1.44l lo.s SCIL 2}

l l <sl 54lo4/ss; IH ITsH TsMitsH TsMi looo44lsioPHltsH+ o.es l o. sal 1o.2 sAI6P 41 i

! 4sl 54lo4/ssi lH !TsH-TsHITsH-TsHI loco 431slePHlTsH+ c.72 1 1.14l lo.s sat lP el t

i

{ sol 54?o4/ssi i a ITsH-TsHjTsH-TsHI loco 441sloPHlTsH+ o.s2 I o.)<l lo.4 xAIlP 41

(

{

l jo4/ssl lH lTsH-TsHlTsH TsHj joco44lsloPHlTsH+ o.s3 l o.5sl

{o.s MAIlP 4)

)

1 I s4) 54lo4/ssl 1H lTsH-TsHjTsH-TsHl looo43lssoPHlTsH+ o.11 l o.741 lo.2 sCIlP 5l 1

) 7ol s4lo4/ssl lH lTsH-TsHlTsH TsHj l coo 44lsioPHlTsH+ o.o1 l 0.ss) l1.3 SCIjP sl l

\\ 23) 55lo4/ssl lH [TsH-TsHlTsH-TsHl looo45ls20PHjTsH+ c.la l o.3s{

lo.2 sAIlP 4l l

l 47] s5lo4/ssl lE lTsH-TsH\\TsH-TsHl l coo 4sjsloPHlTsH+ 1.ss l o.7ol lo.2 MAIlP al

{

l l

los/ssl l a ITsH-TsHlTsH-Tssi locassistorslTsH+ 1.s7 l 1.111 lo.2 MulP 21 t

l 4sl 5slo4/ssl lE lTsH TsElTsH-TsHl l coo 45lslePHlTsH+ o.2s l o. sol jo.4 MAIIP el l

l l

lo4/ss)

}H lTsH-TsHlTsH-TsHl lco045lsloPHlTsH+ o.5s l o.1sl lo.2 MAIlP 4l l

1 s11 ssio4/ssl lE iTsH-TsHITsH.TsHl loco 4sisloPHITsu+ o.3s I c.s4l 1o.4 MAzlP el I

l l

les/ssl lB {TSH-TSHlTsH-TsHl loc 04slsloPH(TsH+ o.3s l o.4sl lo.s MAIlP el l

1 sal ssio4/ssi

} m ITsH-TsHITsu-TsHl loco 4sisioPHITsH+ o.43 l o.sli i.2 sArtP 4l 1

1 4sl ssio4/ssl l u lTsH-TsHlTsH-TsHj lo004sisioPHlTsH+ o.s2 l o.321 1o.3 MAzlP al l

1 lo4/ssl l u lTsH-TsalTsu-TsHI looo4slsioPHlTsa+ 1.39 i o.4ol 10.2 Mu i P 2 l 1

1 4s1 salo4/ssi lH lTsu-TsHITsH-TsHl lcootsis10PaltsH+ o.3s l c.sst to.4. mat lP 4l l

1 l

lo4/ssl lH (TsH-TsHlTsH-TsHI l0004sl61oPEITsH+

1.73 l o.7sl 10.3 MAIjP 4}

}

l10ol ssio4/ssl I a ITsH-TsalTsH-TsHI loooesisioPHITsH+ o.ca i c. sal lo.e scrip sl I

L_J ___ l l

L_1

)

l_

I

_I I

_I l _._ C -_ L_ t _ I ROCKRIDGE TECHNLOGIEs

,a

+__

- -- _~~,

- -~ _ - _ _

I i

CIDfJLATItfE REPORr 04/s6, BGE5 CALVERr CLIPPs, UNzr i :

STEAM GENERATOR 11 I

OITTAGE DATA SET

't CURRENT PAGE:

2 OF s

SELECz1ON VARIABLEss zndication Location, percent DATE:

06/os/s6 TIMEt 22 33:48 i

l l

l EXAM l l

l EXAM EXTENT l l

l l

l

}

l ROW lLINl DATEl HEAR #1 LEG] PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCArzON

\\VOLrsl MIL lDEGl % fCH lCHNGl 1-_- L_- l l

L_I I

(__l 1

1 l

L-.l_ I_ L._I___.l i 17l s7lo4/ssl l H trsH rs5lrsH-TsRI jooodslslorElTsu+ o.4o l o.54) jo.slxAz!r 4l l

l 1

1.ca/ssi i n jese rsaltsu-rsal loco 4slstorslrss+ o.41 l o.s4l lo.s tuu:e 4l l

I 571 svlo4/ssi i a issu-rsuitsu-rsal-loco 4sistorstrss+ o.7s i 1.tsi lo.sixAz!,4l l

l l

lo4/sst i n lrss-rsvlrsa-rssi 'too64ststorstesu+ o.ao l o.s7l lo.sinute 41 1

~

l sol salo4/ssi i n lrsa-rsslrss-rsal loco 4sistormirss+

,.21 1 o.est lo.sjsute4l l

'~

l 321 solos /ssi l x lrsm-rsslrss-rsal toco4ststerslrss+ o.ts I c.ssl lo.21su ir 41 1-I sti selo4/ssi i a irsa-rsstres-rsal loco 4sistorstrsu+~o.vs I o.4 1 lo.stsu e 4l l

l tal selo4/sst I a less-rsairsa-rsal loco 47 tstorstrsa+ o.as l 1.tal lo.stmAz e 4l l

1 l-lo4/ssi I a Irsm-rsairss-rsal l coo 471storstess+ o.27 l o.s2l lo.4 txAz 'r el l

l 15l sslo4/ssl l R { TEE-TsElrsH-rsB) l coo 48lstorElfss+ c.17 l o. sol lo.s]Mu e 4l l

1 l

lo4/ssi l-u less-rsairsa.rsal looo4sistormirsa+ o.so 1 2.e4l lo.7txu e 4l l

-l 17l ss{c4/ss{

l E {TSs-TsRITSE rsal jo0o47lsloralTss+ o.s2 l 1.o8l lo.stNAz*,4l 1

j l

1 lo4/ssl l H jrsE-TsEITsH-TSBl toco47lstorEITss, o.42 I o.7sl jo.slNAz'r 41 l

1 tel sslo4/ssi i n Irsa-rsattsu-tsal loco 4elstoraltss+ o.os

! 1.svl lo.sisez e sl l

1 221 selo4/ssi J a irss-rsairsa-rsal looo4sistorHITsB+ c.2s l 1.141 lo.3lsM e 4l 1

l I est solo 4/ssi l n irsu-rsairsa-rsal loco 47lstoraltss+. o.24 i o.7el lo.2lsAz e 41 l

I ssi sslo4/ss{

l 8 lTsa-Tsultsa-rsal lcoodsistorsjtsg+ o.se 1 0.481 lo.s tMA2 r 4]

l l

1 lo4/ssi l H lTsH-TsHlTsH-rsHl l coo 4sjstorHirsu+ o.ss

' o.4el lo.slMAz e 4[

l l ssi selo4/ssl l u trsu TsslTsu-rsal looo4sistoraitsa+ o.to

, o.e71 (t.olsez e si l

1 41 solo 4/ssi i n irsa-rsstrsa-rsal looo471storstrsa.- o.o.

I c.sel lo.slsez r si l

l 1

i lo4/ssi I a irsa-rsairsa rsal loco 471stornirss+ o.s7 1 c.731 lo.71sA e 41 l

l til solc4/ssi I a lesa-Tsultsa-rsat looo4sistopairsn+ o.2s i o.s71 lo.sisu e 41 l

1 isI solo 4/ssl l x lrsa-rsairsa-rsal l coo 471storslrss+ o.os

! o.sti lo.siser r sl t

l 1 541 sojo4/ssl l u less-rsultsu-rsal loco 4ststoralrsu+ o.s2 I o.ssi lo.41su r el l

l 1 sei solo 4/ssi i u less-rsultss rsal looo471sterntrsa. c.s?

I c.vs) lo.sixAzr41 l

1 t

to4/ssi

-l u irsu-Tsnlrsa-rsni loco 47lstorstrsa+ o.s4 i o.ssi lo.4 txAt e 41 l

l 151 silo 4/ssl l u less-rsnlrsa-rsal icoo4alstoralTsu+ o.12 1 3.4sl it.olsez e si i

j l 17 j stlo4/ssl l H lTsH-tsnlrsE tsHl 10oo47lstorHlTsa+ o.2o

} 1.c4l lo,41sAz e ([

l I sal silo 4/sst I u irsu-Tsultsu-Tsul looo4sl6 tora lTsE, o.o4 i o. sol lo.7lSC e sl l

t isi silo 4/ssi l w Irsa-rsairsa-rsal loco 47lstoraltsa+ o.it i o.ssi lo.41sez r si l

1 soi salo4/sst l u lesu-Tsultsa-rsal looo4sistoralrsu+ o.as i o.ssi lo.stsAz y el l

l 1 set salo4/ssi i u lesu-tsulrsn-rsal l oo12s! s t ornt rsa-o.ot i o. sal jo.sisez e si i

) 24! sato4/ssi i n irsa-rsnlTsa rsal loco 47lstorslrsa+ o.22

{ o.?si lo.sjsAz r 4l l

I 181 selo4/ssi l H lrsH-rSBlTsH-rsMI lco054lslorHlrss+ o.23

[ 1.2sl lo.sjsAz;r 4) l l

} sat ssio4/ssi-l a Irsn rsslrsa.rsal looossletorslrsn+ o.cs l 1.s:1 lo.sisez r si l

l l 4sl ssio4/ssi I u lrsa-rsattsu Tsal looossistoruirsu+ o,24 i 2,s8) jo.sjsAzle 41 l

l 271 s7]o4/ssi i a irsn-rsairsu-rsal locoselstornissa+

o.o*

1 2.471 11.slsez.e si l

l 771 s7lo4/sst

( n itsn-rsattsu-tsal looossisterstrsa+ o.os i 2.12l Is.41scrit si l

i vsl selo4/ssi i a jrsa-rsnjrsa-rsni looossisicestrsu+ o.ov I o.not it.olsex,e si i

i set aste4/est I a itsu-Tantrsn-rsal looostistorajrss+ o.os I o.ssi to.stscz!r si i

I 771 7stos/ssi l a lrsa-rsaltsu-rsal locosolstorattss+ o.to l 1.tst to.siser:p si l

1 sat 74lo4/ssi i a irsa-rsaltsa-rsal looosolstoraltsa+ o.34 1 1.o21 lo.sisezir si i

1 541 74to4/sst I a trsn-rsalTsa-Tsul locos 11storaltss+ o.ss i 2.tol lo.slsu ir el l

1 sal 7 slo 4/ssi I a irss-rsairsa-rsal loonsalsterstrsu+ o.o4 l o.431 lo.slSCz f e 5l l

l 72l 7slo4/esl 1 H jrsH-TsalTsH-TSEl lo00s2lsiorHlrsa+ o.oo l 1.14l lo.71scrir 5[

}

L._ L_ l-1 I_l l-l_1

_I I

__. I l_ I _ L._- _- l _ l i

ROCERzDGE TECENOLOGzEs

. ~

---~-.~-.~.~_------.--_~.u CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1

}~

STEAM GENERATOR

11

{

OUTAGE DATA SET

tt.RRENT PAGE:

3 OP 5

DATE:

06/05/96 SELECTICN VARIABLES: Indication Locaticn, Percent

"'IME :

22:23:48 J

l l

[ EXAM l l

l EXAM EXTEFT - l l

l l

l l

4'

. l ROW lLINI DATEl HEAT #l LEG l PROGRAM l ACTG.'.lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lCIGl % lCH lCHNGl l_l_1 I

l_I I

LI 1

1 1

1_L l_l._l

_l

} 88l 76l04/96l lE lTSB TSElTSE-TSEl-l00062l610PElTSH+ 0.08 l 0.62l l0.3l SCI (P 5l l

] 70l 78l04/96l lE lTSE-TSElTSE-TSEl l00063l610PElTSE+ 0.52 l 0.60l l0.2lSAIlP 4{

}

l 74} 18104/96) l E lTSH-TSElTSE TSEl l00063l610PRj785+ 0.08 l 0.72l l0.2l SCI lP 5l l

j l 72l 80l04/96l l E lTSE-TSElTSE-TSI) l 00b64 l 610PElTSE+ 0.07 l 0.76l l0.7lSCIlP 5l l

l 14} 80l04/96l l E lTSR-TSElTSE-TSEl l00125l610PElTSE- 0.03 l 0.62l l0.6l SCI lP 5l l

j j 41} 81]Q4/96l lE lTSE-TSElTSE-TSIl l00143]61DPE[TSB+ 0.00 l 1.06l l1.0l SCI lP 5l l

j l 71) 81l04/96}

l M lTSE-TSElTSE-TSEl l00065l610PElTSB+ 0.68 l 0.99l l 0.2 lSAIlP 4 l l

}~

j 70l 82 04/96}

} H lTSE-TSElTSB TSEl

! 00063 l 610PHlTiiE+ 0.22 l 0.72l l0.3lSAIlP (j l

l l 53l 83:04/96l l E lTSH-TSElTSE-TSEl

'00lb1l500DPlTSE+ 0.04 l 0.54l l0.4l SCI lP 5l l

l 75] 83 04/96l l E lTSH-TSRlTSH TSEl

00062l610PElTSE+ 0.35 l 1.82l l 0. 6 lMAIlP 4 l l

j l

l 04/96l l E lTSH-TSElTSH TSEl

'00062l610PElTSH+ 0.89 l 1.75l l0.3lMAIlP 4l l

l l

04/96l lB lTSH-TSHlTSE-TSEl

.000621610PHlTSE+ 0.90 j 0.73l l0.5lMAllP 4l l

1 l 70l 84 04/96) l E lTSH-TSHlTSH-TSEl 00062l610PHlTSH+ 0.23 l 1.12l l0.2 lMAIlP 4 [

j j' }

04/96}

l B lTSH-TSElTSH-TSEl 000621610PHlTSE+ 1.06 l 1.29l l0.5lMAIlP 4 l l

j l 72l 84 04/96l l H lTSH-TSBlTSH-TSEj 00062!610PHlTSH+ 0.10 l 0.44l l0.2l SCI (P 5l l

l l

l 04/96l l N lTSH-TSHlTSH TSE[

00062l610PHlTSE+ 0.50

[ 1.28l l0.6[MM lP 4l l

)

]

04/96]

lE lTSH-TSHlTSH-TSR!

00062 j 610PE lTSH+ 0.84 l 2.11l l1.5 lMAI(P 4l l

t t 74l 84 04/96) l H lTSH-TSElTSH-TSEl 00125l610PElTSH+ 0.43 l 0.84l l0dlSMlP 4l l

l 78) 84 04/96}

l N lTSH-TSHlTSH-TSEl 00062 ! 610PHlTSH+ 0.67 l 1.36l l0,7lSA!lP 4l l

]

l 11l 85 04/96l l H lTSH-TSHlTSE-TSBl 00066f610PHlTSH+ 0.38 l 0,36]

l0.7lMAllP 4l l

l l

04/96l lH lTSH TSHlTSH-TSEl 00066i610PHlTSE+ 0.39 l 0,53l l0,5lMAIlP 4l l

l 60l 86 04/96l l E lTSH-TSHlTSH-TSEl 00139l610PHlTSH+ 1.02 l 0.55l l0.5lSAIlP 4l l

}

l 04/96l l M lTSH-TSHlTSH-TSEJ 00139.610PHlTSH+ 1.34 l 1.33l l0.3 lSAIlP 4 l l

l 70] 86,04/96l l H lTSH-TSElTSH-TSEj

'00066'610PHjTSH+ 0.14 l 1.00l jo.3lMAIlP 4l l

4 l

l 04/96l l E lTSH-TSHlTSH TSHI 00066. 610PH l TSH+ 0.36 l 1.02l l0.9lMAIlP 4 l l

i l 59] B7'04/96l l H lTSH-TSElTSH-TSEl 00139!410PBlTSH+ 0.13 l 0.34l

[0.4lSAIlP 4l

[

] 69] 87 04/96l l E lTSH-TSBlTSH-TSBl 00066:410PHlTSH+ 0.58 l 0.41l

{0.3lSA!lP 4]

l

]

l 71) 87 04/96l lH lTSH-TSElTSH TSEl 00066l610PHlTSH+ 0.46 l 0 19l l0.8lMAIlP 4l l

I j

04/96l l H lTSH-TSHlTSH TSEl 00066l610PHlTSH+

0.79 1 0.98l l0.7lMAIlP 4l l

I 73l 87 04/Se}

} H ]TSH-TSHjTSE.TSEl

' 0006 6 l 610PH l TSH+ 0.41 l 3.25l l0.5 lMAIlP 4 l l

.l l

44/96l lH lTSH-TSHlTSH TSE(

000661610PHlTSE+ 0.59 l 0.97l l 0. 5 (MAIlP 4 [

l 1

l l

04/96l l5 lTSH-TSElTSH TSEl 00066 { 610PH j TSH+ 0.61 l 0.41l l0.5lMA!!P 4l l

l j

l 77l 87 04/96l l H lTSH-TSElTSH-TSEl 00066l610PHlTSH+ 0.90 l 1.22l

{1.0lMAIlP 4l l

l l

'04/96l l E lTSH-TSElTSE-TSEl 0006 6 l610PH j TSB+ 1.02 l 0.48l l0.6lMA!lP 4l l

{

j 79) 87 04/96}

lE lTSH-TSHlTSE-TSEl 00066l610PHjTSH+

0.57 l 0.55l l0.3lSAIlP 4l l

j l 76l 90 04/96l l B lTSH-TSHlTSH-TSEl

'00070l610PH{TSH+ 0.34 l 0.36l l0.7lMAIlP 4l l

)

]

1 j

04/96l lN lTSH-TSElTSE-TSEl 00070 l 610PElTSH+ 2.61 l 0.58l l0.7(MA!lP 4l l

l l

04/96l lN lTSH-TSElTSH-TSEl 00070j610PElTSH+ 3.89 l 0.39l l0.3lMAIlP 4l l

l 78l 90 04/96l l E lTSH-TSHlTSH TSE) 00070iG10PHlTSH+ 1.47 l 0.60l l0.5lMAIlP 4l l

I l

l 04/96l l E lTSH-TSBlTSH-TSE]

00070l610PElTSH+ 1.49 l 0.44l l0.3]MAIlP 4l l

j l 67l 91 04/96l l B lTSH-TSElTSH-TSEl

!00071l610PRlTSE+ 0.48 l 1.30l l0.4lMAI[P 4]

l

]

l 04/96l lB lTSH TSElTSH-TSEl

!00071l610PHlTSB+ 0.50 l 0.63l l0.5(MM lP 4l l

{

l l

04/96l lE lTSH-TSHjTSH-TSBl

! 00071l 610PH lTSE+ 0.51 l 0.72]

l0.5lMAI(P 4l l

l 711 91 04/96l lE lTSH TSHlTSE-TSEl

!00071l610PHlTSH+ 0.61 l 5.32l l0.5lMAIlP 4l l

l l

04/96l lE lTSH-TSHlTOH-TSEl

00071l610PBlTSE+

0.67 l 4.22l l0.5lMAIlP 4l l

L _l_

i 1_1 L _._

L__

1 1

I

!_ I _ l _l.__I_ _I ROCKRIDGE TECHNOLOGIES i

J

.n an-

.a n.

n

~-..

d

[

CUMULATIVE REPORT c4/95, BCE, CALVERr CLIFFS UNIT 1 r

STEAM CENIAATOR lt.

PAGEr 4 OF s

DifrAGE DATA SET t CURRENT' DATE:

c6/o5/96 SELECTION '.*ARIABLES: Indication Location, Percent.

4 i

TIME:

22:33:48 h

l l EXAM) l l EXAM EXTENT l l

l l

l

)

jROWlLINl OATEl HEAT 8l LEG lPROGRAMj ACTUALIEXPj CAL l PROBE l LOCATION l VOLTS lMILjDEGI % lCH ICHNGl I

L _. l _._. I I

l.__. I I

l_I l

1 i

L _l._ _ L_.L _ L_ l j

s7l salo4/ssi l n Ins-rsnlrsu-rsal looonistoPslrsu+ o.so l o.7si to.4tm ulP 41 1

+

i i

lo4/ssi l a irsu-rsslrsa-rsal loco 73lszcPulrss+ o.so lo.74l lo.4txA!!P el

(

l Io4/ssi l n irsa-rsstrsa.rssl looonistoPairss+ o.si l o.4sl lo.simulP 41 1

til salo4/ssi i a irsa-rsairsa-rsal lodo72lssoPutras+ o.22 l2.82l lo.stuA!!P4l l

4 l

lo4/ssl l n Irsa.rsairsu-rsal looo72lstoPaltss+ o.se io.esl lo. luAIIP 4l l

vol e4lo4/ssi l x lrsa.rsslrsa-rsal loco 7sistiPaltsa+ o.as l2.o8l lo.sinAIIP 4l t

r i

lo4/ssi l a irsa-rsairsu-tssi loootsistoPsirss. o.7s l 2.c41 lo.4tuulP 41

'l i.

72l s4to4/esl l n Irss-rsslrsa-rsal l oco72 lsioPatr'su+ o.43 I c. sol lo.7lsA!!P 41 1

j 13sls5lo4/s6l lB lTsH-rsHlTsH-TsEl loo14slsloPRlrsH. c.s5 l o.84l lo.71sA!lP 1l

.l i

i lo4/ssi l u lrsa rsslrsn-rsal lootesistoPsircli. c.ss I o.ssi lo.sisAIIP 11 i

set s71o4/ssi l n irsn-rssjtsu-rsal looo78lstoPnlrsa+ o.st I o,s81 lo.8lsAIlP4l l

4 441 s8to4/ssj l n irsu-rsslrsa.rsal loot 41stoPairsu+ o.37 l o.sti to.21sC!lP st I

{

ol sslo4/ssi i n irsu-rsairsu-rsal looonlsioPnlrsu+ o.o Io. sol l. IsujP 4l l

t

]

70l1oojo4/ssi l N IrsH.TsNjTsH.TsHl loco7slsloPHjTsH+ o.1s l 0.s7l jo.3lMAIlP 4l l

28lto2io4/ssl l n lisa.rsultsu-Tsal loott4lsioPnlrsu+ o.ot i o.svl lo.71sCIIP si l-ujzo4;o4/ssi i a Irsa.rsairsu-rsal looit4lstoPalvsu+ o.es I o.s81 lo.sl SCI lP sj l

l 2tlto7;o4/ssl 1 n irsa-rsnlrsa.rsal loott21stoPultsn+ o.18 l o.44l lo.sjsCIIP si I

j stl1081C4/ssl lH lrsn-Tsultsa-TsHl lco138lsloPHlTsH+ o.34 l 0.43l j.2slsAIlP el l

l sslnoic4/ssl l u trsa.rsattsa.rssi loon 81stoPaltsu+ o.so l o.sol l.2slsAIIP 4l l

84lalojc4/ssl lH lTsH.TsnlTsH-TsHl loo081lsloPHlrsa+ o.ot I o.64l lo.4l SCI lP si

(

u812tolo4/ssi l x lrsn.rsultsa.rsal loonstsioPairsu+ o.os I o.s41 lo.sisCIIP sl l

l nintio4/ssl I a irsu-rsairsa.rsal looo81lssoPultsu+ o.os I o.s7l l.4l SCI (Ps (

l 521112iC4/s61 l'n lTsH.rsnlTsu-TsHl loo137lslePHlrsH+ o.ss l o.71l.

jo.stsAllP 4l l

j s4l222io4/ssl l n irsa.rsairsn-rsal loo 137lstoPnirsn+ o.4s i o.4tl lo.2luulP 41 l

s2ln4;e4/ssl l a irsa.rsulrsa-rsal l oon sinoPultsu. o.4s -

l o.sil lo.sisulP 4l l

l lo4/ssi i n itsn.rsultsu.Tsn[

joc13slsioPHlTsB+ o.ss I o.84l lo.4lsAIIP 4l l

sojuelc4/ssl l a irsn rsntrsn rsal locu?lsioPuirsa+ o.os I o.ssl jo.4lsCIIP sl l

' 47 ns;e4/ss!

l n jrsa-rsaltsu.rssl lootsslssoPajrss+ o.st I o. sol lo.21sAIIP 4l 1

i stltisio4/ssi l n Irsa.rsnlrsn-rsal loot 271sioPultsu+ o.s4 l o.ssi to.2lsAIIP ej i

s2111 sic 4/ssl lH ITsu-rSHlTsH.rsal l c o137 l sloPHlTsH+ o.34 l o.s8l lo.21sulP 4l l

salusic4/ssi l n Irsa-rsuitsu-rsal loos 24lsioPultsu+ o.os I c.ssi t o.2lmCII 21 l

j 5sl118]e4/ssl l a lTsH.TsHlrsn.TsHl lo0138lsloPHlrsh o.05 l o.sil l.47l SCI lP sl l

f soln 81o4/ssi i n jrsa-rsairsu-TsEl lco087lsloPHlrsH+ o.o?

l o.881 l o.slsCII 21 1

'l 1ol12olo4/ssl lH lSSI-TsRlisH-rsHl lco112lsioPElTsH+ 0.2o l o.s3l l.4lsAIlP 4l l

)

sslusjo4/ssl l u irst:.rsslrsn-rsnj locos 21sioPairsa+ o.12 1 o.ssi lo.21sCIIP si I

2six4tio4/est I a irsa.rsnlrsa.rsal looto41stoPaltsa+ o.2s I o.asi lo.21sulP 41 l

j al1471o4/ssl l u lisa.rsairss-rsal looto71stoPultsa+ o.is i 2.15l jo.sisulP el I

i l._-.J 1

l_ I I

l_I l

i I

l _ l _ l-__ L_ l _ t l

1 1

ROCERIDGE TECHNOLOGIES

_m.

.~...~m~

.___.m I

CUMUIATIVE REPORT 04,/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

5 OF

)

OLTTAGE DATA SET

CURRENT

. DATE:

06/05/96

' SELECTION VARIABLES: Indication loca *. ion, Percent TIbE 22:33:48 l

1 NUMBER Of TUBES SELEC"TED FROM CURREll? OUTAGE 134

]

NUMBER OF DATA RECORDS SELECTED FROM CURRENT OtTTAGE:

172

)

l NO TREND ANALYSIS REQUESTED DATA SELECTION CRITERIA:

Indication Location: TSH -1.00 to Tf;H +5.00 Percent: MAI, MCI,SAI, SCI REPORT CPTIONS:

Only examination results matching criteria are included 9

i l

ROCERIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1

. STEAM GENERATOR

11 PAGE:

1 OF 1

'JTAGE DATA SET CURRENT DATE:

06/05/96

. ELECTION VARIABLES: Indication Location, Percent TIME:

23:42:07 t

4

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

i Indication Location: O1H 1.00 to O1H pl.00 (Supports Only)

Percer.t MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included I

l

\\

ROCKRIDGE TECHNOLOGIES 4

1

.. -. =

CUMUIATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

UTAGE DATA SET

CURRENT DATE:

06/05/96 JLECTION VARIABLES: Indication Location, Percent TIME:

23:48:43 7

      • NO CALLS IN THIS RANGE ***

l DATA SELECTION CRITERIA:

2ndication Location: 02H 1.00 to 02H 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI

- REPORT OPTIONS:

Only examination results matching criteria are included e

e a

f i

s i

f I

I

.l l

l i

4 ROCKRIDGE TECHNOLOGIES I

1 CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

  • 1TAGE DATA SET CURRENT DATE:

06/05/96

.:LECTION VARIABLES: Indication Location, Percent TIME:

23:49:25 i

I

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 03H 1.ss to 03H. 1.00 (Supports Only)

Percent.: MAI, MCI,SAI, SCI REPORT OPTIONS:

s only examination results matching criteria are included

.f s

4 1

l ROCKRIDGE TECHNOLOGIES

i 1

CUMULATIVE REPORT 04/06, LJE, CAINERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGEt i OF 1

O!. CAGE DATA SET r CURRENT DATE 06/05/96 SE* ECTION VARIABLES: Indication location, Percent TIME 23:50:19 I

I I EXAM) l l EXAM EXTENT l l

l l

l l

l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXP) CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l _ _I _ l I

l_I I

l_1 I

i i

l_ l _.l_ l__ l_ I l 251 ssl04/ssi lH l04H.04H1048 04Hl1 l0015 sis 10PHl04H. 0.3s 1 0.771 10.sisAIlP 4l l

l l

l04/s6l lM l04H.04Hl04H.04Hl1 l00155l610PHjo4H+ 0.s0 l 0.71l l0.3lSA!lP 4l l

l_ l_ l I

l___I I

l__ I I

I I

l_I___ L_ l_I I

NLTmER OF TUBES SELECTED FROM CURRENT OITIAGE: 8 1

NCMihER OF DATA RECORDS SELECTED FROM CURRENT OITTAGE:

d NO TREND ANALYSIS REQUESTED j

DA!A SELECTION CRI'!ERIA:

Ir.dication Location 04H 1,00 to 04H 1.00 (Supports Only),

Pa: : ent ; MAI, MCI, SAI, SCI RE70RT OPTIONSr s

Or.;v examination results matching criteria are included l

t I

I l

i ROCFJtIDGE TECIDIOLOGIES

=,

i i

l CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 l

STEAM GENERATOR

11 PAGE

1 OF 1

j UTAGE DATA SET

CURRENT DATE:

06/05/96 i

, ELECTION VARIABLES: Indication Location, Percent TIME:

23:56:16 I

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 05H

1. 00 to 05H - 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

]

3 Only examination results matching criteria are included

)

l l

l i

4 1

)

4 1

a 1

l i

s I

V ROCKRIDGE TECHNOLOGIES

. ~,

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

'UTAGE DATA SET

CURRENT DATE:

06/05/96' 2LECTION VARIABLES: Indication Location, Percent TIME:

23:57:01

      • NO CALLS IN THIS RANGE ***

i DATA SELECTION CRITERIA:

Indication Location: 06H 1.00 to 06H. 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI l

REPORT OPTIONS:

{

s Only examination results matching criteria are included n

4 1

1 1

ROCKRIDGE TECHNOLOGIES

CUMULATZVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

'UTAGE DATA SET

CURRENT DATE:

06/05/96 2LECTION VARIABLES: Indication Location, Percent TIME:

23:58:03

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 07H 1.00 to 07H pl.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI 8

REPORT OPTIONS:

s Only examination results matching criteria are included ROCKRIDGE TECHNOLOGIES

.c CUMULATItE fiPORT 04/96, BCE, CALVERT C1IFFS, UNIT 1 STEAM 3ENERATOR t 11 FAGE:

1 OF 1

OtfrAGE DATA SET CURRENT DATE:

06/06/96 SELEC" ION VARIABLES: Indication Location, Percent TIMEt 00 01:55 l

1 1

I EXAM l l

l F.XAM EXTFET l l

l l

l l

l ROW lLIN) DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION jVOLTSl MIL lTEGl % l CH j 0(NGl L_._ I _ I I

l_ I I

l_l i

I I

l _ l __L_ l_._1 _ l l129l 97l04/96l l E l04H+VM l04H.VN l7 l00919l580FPjo85+ 0.61 l 0.71]

) 67lSAI{P 4j l

l L._.I I

l __ I I

l_l l

l 1

L_. l __1_ l _ i _._. I NUMBEA OF TUBES SELECTED FROM CURRENT OUTAGE:

1 NUMBER OF DATA RECORDS SELECTED FROM CURRENT OtfrAGE:

1 NO TRE O ANALYSIS REQUESTED s

DATA SILECTION CRITERIA 1rflication Locations 08H pl.00 to 08H pl.00 (Supports Only)

Percer.

MAI, MCI,SAI SCI REPORT OPTIONS Only examination resulta matching criteria are included ROCKRIDGE TECHNOLOGIES

\\

a.

CUMUIATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM 'IENERATOR

11 PAGE:

1 OF 1

OUTAOI DATA SET CURRENT DATE:

06/06/96 SELEZION VARIABLESi Indication Location. Percent TIME:

00:17:52 l

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW :.:Nl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS lMILIDEGl % lO{ lCHNGl l_ _I I

i_I I

l.__ l l

I I

l__ L__l.__I _ I _ t l 93 37l04/96l l B l09H-09Hl09H-09Hj l00158l500DPl09E+

0.34 l 0.45l l0.3lSAIlP 4l l

l100 42l04/96l lM l09H-09El095-09El1 l00156l610PHj09H-0.01 l 0.20l l.3lSAIlP 4l l

l121 63l04/96l l H l045-VM l04H-VM l7 j00757l580FPl098+ 0.49 l 0.51l l0.1lSAIlP 4l l

l110 72l04/96l lH l09H-09El095-0$Hl5 l0d170l580PHl09E+ 0.11 l 0.77l l0.2lSAIlP 1l l

l 98 74l04/96l l H l04H-VM l04H-VM l7 l00579l580FPj09H+ 0.00 l 0.34]

l0.2lSAIjP 4l l

l128 78l04/96l lH l04H-VM l04H-VC l7 l00697l5F0FPl09H+

0.20 l 0.61l 10.2lMAIlP 1l l

l l04/96]

lB l04H-VM l045-VC l7 l00697l580FPl095+ 0.22 l 0.43l l0.2lMAIlP 1l l

l108 80l04/96l lH l04H-VM l08H-DH l7 l 00902 l 500FP l 0'93-0.01 l 1.26l 0.2lSAIlP 4l l

l l04/96l lH l04H-VM l00H-DH l7 l00902l580FPl09H+

0.09 l 1.25l 60lSAIl 1l l

l104 84l04/96l lH l09H-09Hl095-09El5 l00176l580PHl09F+

0.01 l 0.33l 0.6lSAIlP 4l l

l100 88l04/96l lH l09H-09El095-09El5 l00175l580PHl098+

0.01 l 0.51l

,0.7lSAIlP1l l

l l04/96l lE l098-09H[095-09El5 l00175l580PHl09H+

0.39 l 0.45l

0.5l SCI lP 5l l

l101 89l04/961 lH l095-09Hl09H-09Bl5 l00175l580PHl098+

0.23 l 0.51l

.0.2lSAIlP 4l l

l113 89l04/966 lM l09H-09Hl0$H-09Hl5 l00175l580PHl09H+ 0.13 j 1.19l 0.4lSAIlP 4l l

l 94

  • 00l04/96 !

lH l09H-09Hj09H-09Ej$ l00175l580PHj09H+

0.40

[ 0.31l 0.3lSA!lP 4l l

l106 100l04/96; lH jo4H-VM l04H-VM j7 l00429l580FPl09H-0.01 l 0.44l 0.3lSAIlP 4l l

l100 140l04/96:

lH l08H-VM l08H-VM l7 l00194l580FPj09H+

0.40 l 0.57) 0.3l SCI l 2l l

l_ _I l.__ I I

l_I I

I I

! __ _ __ L_ l_ L.__ I NUMED OF TUDES SELECTED FROM CURRENT OffrAGE:

14 NUM3U. OF DATA RIcoRDS SELECTED FROM CURRENT OtTTAGE:

17 NO SED ANALYS:S REQUESTED DATA !!LECTION :~RITERIA:

Ind:. :nion Location : 09H [0.$0 to 09H p0.50 (Sqports. Only)

Per:fr: MAI. MC:. SAI, SCI REF^ ' OPTIONS.

Onis examinaticr. results matching criteria are included ROCERIDGE TECHNOLOGIES

CUMUIATIVE REPORT 04/06, BG3, CAI. VERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

OUTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTICN VARIABLES: Indication Location, Percent TIME:

00:21:11 l

l j EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLIN) DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION lVOL?Al MIL lDEGl % lCH lChNGl t

L._.L.__!

I L__ l l

l_I I

i i

l___1 _ I_._1 l ___._ I 1133j 57104/96l l E l05E-VM l055-VM l7 l00931l580FPl10B+ 0.21 l 0.53l l 90l8AIlP 4l l

L_.L__1 I

l.__f _ __l l___I I

I I

L _L__l_ l.__l

_I NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE:

1 i

NUMBER CF DATA RECORDS SELECTED FROM CURRENT OlffAGE:

1 NO TREND ANALYSIS REQUESTED 5

i DATA SELICTION CRITERIA:

ndicaticn 1ccation: 10H 0.50 to IDH p0.50 (Supports Only) l Fercent: M.AI, MCI,SAI, SCI REPORT C7710NSi l

?nly exa-ination results matching criteria are included i

l I

l f

1 l

ROCKRIDGE TECHNOLOGIES a

4

45 CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 S N GENERATOR 11 PAGE:

1 OF 1

'JTAGE DA*~A SET

CURRENT-DATE:

06/06/96 i

, ELECTION 7ARIABLES: Indication Location, Percent TIME:

00:25:56

      • NO CALLS IN THIS RANGE ***

DATA SELEC ION CRITERIA:

In:iication Location: DH 2.00 to DH p2.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

On'y examination results matching criteria are included s

i 1

l ROCKRIDGE TECHNOLOGIES

l CUMULATIVE REPORT 04/06, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR 11 PAGE:

1 OF 1

OUTAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME:

00:27:08 l

l l

l l ExAMI I

I EXAM EXTENT l l

l l

l l

(

l ROW lLIN) DATElHEATBl LEG l PROGRAM l ACTUAL lEXPl CAL l PRO 9El LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l

l_I_ I i

l_I I

l._l i

I I

l_L_I_I_I I

l103l 87l04/96l l N l045-VM l04H-VM l7 l00523l580FPlVE - 1.64

{ 0.78l l0.4 lSAIlP 4l l

l110l112l04/96l lB l04H-VM l04E-VM l7 l00376l500FPlVE + 1,66 l 0.67]

l0.4 lSAIlP 4 l l

l_l _I I

L_l L_ _I_I I

I I

l _ I__I__I _ I I

)

NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: '

2 1

NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

2 NO "AEND ANALYSIS REQLTSTED DAT) htLECTION CRITERIA:

J Indication Location: VH 2.00 to VH 2.00 (Supports Only},

l Perct2t: MAI, MCI,SAI, SCI REFCAT OPTIONS:

Only examination results metching criteria are included I

1 i

i

]

ROCKRIDGE TECHNOLOGIES

CIMJLATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STIJ.M CENERATOR 11 i

PAGE:

1 OF 1

OliAGE DATA SET CURRENT l

DATE:

06/06/96 SE"ICIION VARIADLES: Indication location, Percent TIMES 00:33:33 l

l l EXAM l l

l EXR4 EXTENT l l

l l

l l

l RO W l LIN l DATE l HEAT # l LE3 l PROGRN4 l ACTUAL j EX P l CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_I_I I

l_I I

l _.I I

I I

l _ l._ l_._ I ___. l_1 l 6l 6l04/96l lC [06C-065l06C-05El2 l00135l580PElVM +

1.79 l 1.74l l.3lSAIlP 2l l

l 10l 26l04/96l lC l05C-058l05C-05Hl2 l00132l580PHlVM - 0.02

( 0.27l l0.5lSAIlP li l

l 9l ei?4/961 lC jo6C-06Hl06C-065l2 l00148l580PElVM - 1.90 l 1.50l l.4lSAIlP 4l l

l 70l 72l04/96l lB l058-VM l05E-VM l9 l0(l512l580FPlVM + 0.81 l 1.02l l0.4lSAIlP 4l l

l l 9l125l04/96l lC j06C-06Hl06C-065l2 l00158l580PBlVM + 0.03 l 1.25l l1.0lSA1]P 4l l

l 9 l133 l 04/96 l lC lb6C-068l06C-065l2 l00156l5f0PBlVM - 1.15 l1.48l l0.3lSA!lP 1l l

1 _

l._._ !

I l

_l l

l_l I

i l

i_i_1_ _l._l_l

(

! G ER OF TUBES SELECTE FROM CURRENT OUTAGE:

6' l

N*X.:IR OF DATA RECORDS SILECTED FROM CURRENT OUTAGE:

6 i

NC ~7END ANALYSIS REQUESTED DATA SELECTION CRITERIA:

Ini;;ation Location: VM p2.00 to VM p2.00 (Supports Only)

Pe r:ent : MAI. MCI. SM, SC:

i l

REF:IT OPTION 5:

On'-

examination results matching criteria are included i

i l

l l

I l

I l

{

l

{

l l

l ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UMIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

UTAGE DATA SET

- CURRENT DATE:

06/06/96 1

ELECTION VARIABLES: Indication Location, Percent TIME:

00:35:21

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: VC

2. 00 to VC,

2.00 (Supports only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included l

l l

I 8

ROCKRIDGE TECHNOLOGIES I

CUMULATIVE REPORT 04/96, BCE, CALVEET CLYFFS, UNIT 1 l

STEAM GENERATOR 11 PAGE:

1 OF 1

'UTAGE DATA SET CURRENT DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

00:36:10

      • NO CALLS IN THIS RANGE ***

l DATA SELECTION CRITERIA:

Indication Location: DC p2.00 to DC. 2.00 (Supports Only) l-Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included i

l t.

ROCKRIDGE TECHNOLOGIES l

l l

l i

l l

CUMULATIVB REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

'7tAGE DATA SET CURRENT DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

00:50:26

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 10C 0.50 to log 0.50 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

only examination results matching criteria are included ROCKRIDGE TECHNOLOGIES

i CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

UTAGE DATA SET

CURRENT DATE:

06/06/96

, ELECTION VARIABLES: Indication Location, Percent TIME:

00:49r52 l

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

l Indication Location: 09C 0.50 to 09C. 0.50 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included e

J I

ROCKRIDGE TECHNOLOGIES l

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

7 AGE DATA SET CURRENT DATE:

06/06/96 JLECTION VARIABLES: Indication Location, Percent TIME:

00:45:16

      • NO CALLS IN THIS RANGE ***

1 DATA SELECTION CRITERIA:

Indication Location: OBC 1.00 to 08C 1.00 (Supports Only) j Parcent: MAI, MCI,SAI, SCI I

REPORT OPTIONS:

only examination results matching criteria ar,e included j

)

)

l ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

UTAGE DATA SET

CURRENT DATE:

06/06/96 2LECTION VARIABLES: Indication Location, Percent TIME:

00:44:07

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 07C 1.00 to 07C. 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included i

k t

t b

i l

i l

J i

i l

ROCliRIDGE TECHNOLOGIES i

i

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

UTAGE DATA SET

CURRENT DATE:

06/06/96 JLECTION VARIABLES: Indication Location, Percent TIME:

00:43:32

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 06C 1.00 to 06C 1.00 (Supports Only)

Parcent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included e

)

d i

i 0

J i

l l

i l

I ROCKRIDGE TECHNOLOGIES

2-v CUMUIATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 l

STEAM GENERATOR

11 PAGE:

1 OF 1

l UTAGE DATA SET CURRENT DATE:

06/06/96 I

SELECTION VARIABLES: Indication Location, Percent TIME:

00:42:56 l

      • NO CALLS IN THIS RANGE ***

1 DATA SELECTION CRITERIA:

Indication Location: 05C 1.00 to 05C 1.00 (Supports only)

Percent: MAI, MCI,SAI, SCI E

REPORT OPTIONS:

Only examination results matching criteria are included l

r h

f y

{

1 ROCKRIDGE TECHNOLOGIES l

CUMULATIVE REPORT i

04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

'1TAGE DATA SET CURRENT 4

DATE:

06/06/96 JLECTION VARIABLES: Indication Locatior., Percent TIME:

00:42:17

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 04C 1.00 to 04C 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included o

4 4

5 6

k i

ROCKRIDGE TECHNOLOGIES j

J

I CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UMZT 1 i

STEAM GENERATOR

11 PAGE:

1 OF 1

~7TAGE DATA SET CURRENT DATE:

06/06/96 I

.LECTION VARIABLES: Indication Location, Percent TIME:

00:41:37 j

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

l Indication Location: 03C 1.00 to 03C 1.00 (Supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OPTIONS:

Only examination results matching criteria are included l

1 1

I l

I

)

i i

l ROCKRIDGE TECHNOLOGIES 1

l

l I

1 I

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

"IfAGd' DATA SET

CURRENT DATE:

06/06/96

?LECTION VARIABLES: Indication Location, Percent TIME:

00:38:12 1

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 02C 1.00 to 02C pl.00 (Supports only)

Percent: MAI, MCI,SAI, SCI t

REPORT OPTIONS:

s Only examination results matching criteria are included e

i r

h ROCKRIDGE TECHNOLOGIES i

i

CUMULATIVE REPORT 04/96, BGE, CALVERf CLIFFS, UNIT 1 STEAM L1ENERATOR

11 PAGE:

1 OF 1

1UTAGE DATA SET

CURRENT DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

00:37:34 d

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 01C 1.00 to Olc 1.00 (Supports only)

. Ptrcent: MAI, MCI,SAI, SCI j

REPORT OPTIONS:

only examination results matching criteria are included i

l l

I i

ROCKRIDGE TECHNOLOGIES

_..,~

~ -., _.

CUMUIATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

OUTAGE DATA SET CURRENT DATE:

06/06/96 SELEC"I1ON VARIABLES: Indication Location, Percent TIME:

02:03:43 l

l l EXAM) l l EXAM EXTENT l l

l l

l lPC*'*lLINl DATEjHEAT9l LEG lPROGRAMj AC"IVALlEXPl CAL l PROBE l l

LC"ATION l VOLTS l MIL lDEGl t jCH lC} DIG l l __. l _ I I

l__ !

__1 l___l l

I i

_I _ i _ I _ i__._l _ 1 l129l 97l04/96l l5 l04H-VM l04H.VW l7 l00919l580FPj08H+ 0.61 l 0.71l l 67lSAIlP el l

l 35l 99l04/96l lH l045-04Hjo4H 04Hl1 l00155l610PHl04J+ 0.39 l 0.77l l0.3lSA1lP 4l l

l l

l04/96l lH l045 04Hl04H 04Hl1 l00155l610PHl04H+ 0.90 l 0.711 l0.3lSAIjP 4l l

')

l_I_l

.1 l __ I I

LI l-1_

l I _ l_L L _l_1 NUPGER OF TUBES SELEC" RED FROM CURRENT OUTAGE:

2 NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

3 NO U END ANALYSIS REQUESTED DATA SELEC" TION CRITERIA:

Indication Location: 01H pl.00 to 08H 1.00 (Supports Only)

Percenti MAI, MCI,SAI, SCI i

REPORT OPTIONSt Only examination results rr.atching criteria are included 1

ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 06/06, BGE, CALVERT CLIFFS, UNIT 1' j

STEAM GENERATOR 11 PAGE:

1 OF. 1 OtJTAGE DATA SET a CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Locotion, Percent TIME:

02:11:23 l

-l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL!DEGl 4 lCH lCHNGl l-.__ L_J l

L _I I

l_

I I

i 1

l _ L _l_ l _ i _ I 1 93) 37104/96l l a 109a-09El098-09Bl l00158l500DPl09H+ 0.34 l 0.45j l0.3lSAIjP 4l ' l l108l 4:104/96l l a l09m 09sl09s-09sl1 l00156l610Pnl098 c.01 1 0.20l I.3lSAIlP 4l l

]133l 57l04/96l lB l055-VM l05E-VM l7 l00931l580FPl10H+ 0 21 l 0.53l l 90lSAIlP 4l l

l1211 n104/96l l x l04s-vM l04s-vM l7 l0d757 l 580FP l 09H+ 0.49 l 0.51l l0.1lSAIlP 4l l

In01 72104/96l l n l09s-09sl09m-09sl5 -100170l580Psl095+ 0.11 l 0.771 l0.2lSAIIP 1l l

l 98l 74l04/96l l E l045-VM l045-VM l7 l00579l5#0FPl09H+

0.00 l 0.34l

[0.2lSAIlP 4l l

l128l 78l04/96l lE l04M.W l048-VC l7 - l00697l580FPl09E+ 0.20 l 0.61l l0.2lMAIlP 1l l

l'

)

104/96l' lB l04H-VM l045-VC l7 l00697l580FPl0SH+ 0.22 l 0.43l 10.2lMAIlP 1l l

\\103l 80104/96l lE l04H-VM l08E-DE l7 l00902l580FPl095- 0.01 l 1.26]

!0.2lSAIlP 4l l

l j

!04/96l lH l04H-VM l04E-DE l7 l00902l580FPj09R+ 0.09 l 1.25l 60lSAIl 1l l

1104] 84,04/96l I a 1098 09sl095 09 l5 l00176l580Psl09s+ 0.01 1 0.33l

0.6lSAIlP'4l l

l100l 88l04/96l

[B l098-09El09E 09Nl5 l00175l580PHl095+ 0.01 l 0.51l 0.7lSAIlP 4l l

l l

,04/96l l E l09H-09El095-09El5 - l00175l580PHl098+ 0.39 l 0.45l'

,0.5l SCI lP 5l l

l101l 89'04/96l l H l098-09Hl09H-09Bl5 l00175l580PHl09E+ 0.23 l 0.51l 0.2lSAIlP 4l l

l113l 89;04/96l

!E l09H-09El095-09El5 l00175l580PHj09H+ 0.13 l 1.191 0.4lSAIlP 4l l

l 94l100.04/96l E l09H 09Hl09H-09Hl5 l00175l580PHl09H+

0.40 l 0.31l 0,3lSAIlP 4l l

j106l100'04/96l H l04H-VM l045 VM l7 l00429l580FPl09H- 0.01 l 0.44{

0,3lSAIlP 4l l

l100l140'04/96l M l08H-VM l08H-VM l7 l00194l580FPl09H+

0.40 1 0.57l 0.3l SCI l 2l l

L l_

i

_I I

l_1 I

l 1

l-- - _ l _ l _ I_._J NUMBER CT "'UBES SELEC ED FROM CURRENT OUTAGE:

15 NUMBER OF OATA RECCROS SELECTED FROM CURRENT OUTAGE 18 NO TRENO }NALYSIS RE CESTED DATA SELIO." ION CRITER*A Indicatien Location: SPH 0.50 to 10H p0.50 (Supports Only)

)

Percent: V.AI, MCI,SA!. SCI REPORT C?~*0NS:

Only exa-: nation resdts matching criteria are included 1

i ROCKRIDGE TECHNOLOGIES

CUMUIATIVE REPORT 04/26, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGI:

1 OF 1

OLTTAGE DATA SET

CURRENT DATI:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIMT. :

02:15:M l

l l

l EXAM l l

l EXAM EXTENT l l

l l

l

{

l ROW l LI N l DATE l HEAT 8 l LEU l PROGRAM l ACTUAL j EX P l CAL l PROBE l LOCATION l VOLTS l MIL DFGl % lCH lCHNGl l _ L__I I

L__ l l

l_ _I I

I I

l_

_L_L l_I l 6l 6j04/96l l C l06C-06Hj06C-05Hl2 l00135l580PHlVM +

1.79 l 1.74]

.3lSAIlP 2l

{

l 10l 26l04/96l l C l05C-05Hl05C-0$Nl2 l00132l580PHlVM -

0.02 l 0.27l 0.5l$AIlP 1l l

l 9l 45l04/96l lC l06C-06Hl06C-06Hj2 l00148l580PHlVM -

1.90 l 1.50l

.4l$AIlP 4l l

l 70l 72l04/96]

lH l05H-VM l0$H-VM l9 l0d512l580FPlVM+ 0.81 l 1.02l

0.4lSAZjP 4l l

l103] 87]C4/96l l E l045-VM l04H VM l7 l00523l580FPjvu -

1.64 l 0.78l 0.4 lSAIlP 4 l l

l110l112l04/96l lE l048-VM l04H-VM j7 l00376l5db?PlVM + 1.66 l 0.67l 0.4l$AIlP 4l l

l 9]125l04/96l l C l06C-06Hl06C-06Hl2 l00158l580PHlVM +

0.03 l 1.25l

1. 0 lSAIl P 4 l

}

l 9l133l04/96l l C l06C-06Hl06C-06Hl2 l00156l580PHlV'M - 1.15 l 1.48l 0.3lSAIlP 1l 4

)

l_i_I I

l!

I l_I i

I l _ _ L l__._I _ !

NUMBER OF TUBES SELECTED FROM CURRENT OCTTAGE:

8..

NUMSER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

8 NO TREND ANALYSIS REQUESTED DATA SELECTION CRITERIA:

Indication Location DH D2.00 to DC b2.00 (Supports Only)

Percent: MAI. MCI,SAI. SCI REPCTsT OPTIONS:

Only examination results matching criteria are included ROCKRIDGE TECHNOLOGIES

-...-.. _ ~. -.

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

, 11 PAGE:

1 OF 1

'UTAGE DATA SET CURRENT DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

02:18:10 t

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 09C 0.50 to 10C. 0.50 (Supports only)

Parcent: MAI, MCI,SAI, SCI l

REPORT OPTIONS:

only examination results matching criteria are included i

I i

1 i

l ROCKRIDGE TECHNOLOGIES i

l

CUMULATIVE REPORT 04/96, BSE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

7UTAGE DATA SET

CURRENT DATE:

06/06/96

, ELECTION VARIABLES: Indication Location, Percent TIME:

02:18:59

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 01C 1.00 to 08C.pl.00 (supports Only)

Percent: MAI, MCI,SAI, SCI REPORT OfTIONS:

Only examination results matching criteria are included

\\

i i

l l

ROCKRIDGE TECHNOLOGIES i

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS UNIT 1 STEAM CENERATOR

11 PAGE:

1 OF 2

OUTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location,' Percent TIME:

01:27:23 l

1 l rx^Mi l

l Ex^M ExTEwT l l

l l

l l

lRoMILIsl : ATE l HEATS lLEGj PROGRAM l ACTUAL lExPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l

l-__I l-l_1 i

L_1 l

1 l

l_I_l_i_ L._

I l 61l 13l04/96l j H l06H-VM l06H-vM jl2 l00825l580FPl07H+24.48 l 0.56l l0.2lSAI(P 4l l

1101] 31l04/96l-l H l048-vM l04H vM j7 l00434l580FPl07H+ 5.56 l 0.63l l0.2lSAIlP 4l l

1 86l 32l04/96l:

lH l04H-vM l04H-vM l7 1002nl580FPl08H+ 15.26 l 0.74l l0.2l8AIlP 4l l

l 82l 40l04/961 lH l04H-vM104H-vMl7 l00183l580rPj0pH+ 2.66To+ 11.65l 0.42l 10.3lMSIlP 4l l

l104) 42l04/96l lH l04H-vM l04H-vM l7 jo0594l580FPj07H+15.87 l 0.35l l0.2lSAIlP 4l l

l101) 45l04/96l l H l04H-vM 104H-vM l7-l00599l586FPj065+ 20.037o+ 23.64] 0.45]-

10.4lMSIIP 4l l

l 691 53l04/96l l H l04H vM l04H.vM l9 l00482l580rP107H+ v.32 l 0.731 l0.3lSAIlP 4l l

l121l 55l04/96) lH l04H-vM l04H.vM l7 l00730l580rPj07H+ 17.16To+ 24.80l 0.541 l0.3lMSIlP 4l l

l l

l04/ul lH l04H-vM 1048-vM l7 l00730l580FPl08H+ 15.9270+ 21.15l 0.54l l0.2lMSIlP 4{

{

(130l 56104/96l lE l058-vM l05H.VM l7 l00730l580FPl08H+ 14*.05T0+ 18.03l 0.66l l0.2lMSIlP 4l l

l121l 61l04/96l l H l04H-VM l04H VM ]7 l00751l580FPl07H+ 11.51 l 0.60l 10.2lSAIlP 4j j

l l

l04/96l lH l04H-VM l048.VM l7 l00751l580FPl08H+ 14.02 l 0.76]

l0.5lSAI{f'4l l

l106) 66]C4/96l l H l08H-09Hj08H-09Hl1 l00156l610PHl08H+ 16.15 l l'.35j l0.3lSAIlP 2l l

' 43l 67l04/96) lH l06H-vM l06H-VM l11 l00974l580FPl06H+ 14.64T0+ 17.38l 0.55l l 79lMSIlP 4l l

l 104/96l l 8 l06H-VM l06H.VM ln l00974l580FPj06H+ 15.70 l 0.47l l117lMSIl 1l j

' 85l 69104/96l lE l04H.VM l04H.VM l7 l00327l580FPl08H+ 10.83T0+ 12.37l 0.60l l 0.4 lMSIlP 4 l l

121l 69104/96l lH l04H-VM l04H.VM l7 l00767j580FPj08H+

6.18TO+ 11.59l 0.29(

l0.3lMSIlP 4{

l 121l 71l04/96l

.l H l04H-VM l04H-VM l7 l00708l580FPl07H+ 6.12 l 0,45l l0.1lSAIlP 4l l

98] 74[04/96l lH l04H-VM l04H.vM l7 l00579l580FPl07H+ n.2870+ 16.96l 0.55]

l0.1lMSIlP 4l l

l 104/96l' l H l04H.VM l04H.VM j7 l00579l580FPl08H+

9.8170+ 18.67l 0.98l l0.2lMSIlP 4l l

'In j 77104/96l lH l04H-vM l04H.vM l7 l00697l580rPl06H+ 8.30To+ 23.40l 1.35l l0.3[MSIlP 2l l

l 104/96l l H l04H-vM l04H.vM l7 l00697l580FPl08H+ 15.64T0+ 15.92l 0.84l l0.2lMSIlP 1l l

123) 79104/96j lH l04H-vM l04H VM l7 l00914l580FPl06H+ 22.31T0+ 24.13l 0.57) l 89lMSIlP 4l l

84] 82104/96]

lH l04H-0781048-07Hl7 l00392l580FPl06H+ 10.19 l 0.59l l0.3lSAIlP 4l l

81l 85104/96l lH l04H-VM l04H-vM l7 l00398l580FPl06H+ 16.52 l 0.40l l0.2lSAIlP 4l

[

{

104/961

'l H l04H-vM l04H-vM p l00 n 8l580FPl07H+

7.3870+ 13.04l 0.37l l0.3lMSIlP 4l l

128l 86l04/96l lH l06H-07Hl065-07El1 l00918l580FPl06He 11.00TO+ 15.79l 0.67l l 97lMSIlP 4l l

56) 92104/96l lH l06H VM l06H-VM l11 l00952l580FPl07H+ 14.POTO+ 16.97l 0.41l l 71lMSIlP 4l l
125l 93[04/96l l H l0$H-vM l05H.VM 17 l00643l580FPl08H+

2.8070+

5.67l 0.60l

{0.3lMSIlP 4l l

85) 95(e4/96l lE l04H vM l04H-vM 17 l00407l580rPl08H+

2.0770+

5.46l 0.39l 10.2lMSIlP 4l l

60l 96l04/96l

}H l06H-VM l06H-vM l12 l00853l580FPj07H+

9.19T0+ 16.14l 0.43l l2.1lMSIlP 1l l

129l 97l04/96l' l H l04H VM l04H-VM l7 l00919l580FPl08H+ 0.61 j 0.71l l 67lSAIlP 4l l

35l 99l04/96l lH l04H.04Hl04H-04Hji l00155l610PHl04H+ 0.39 l 0.77l l0.3lSAIlP 4l

(

l lO4/9fl lH l04H-04Hl048-04Hl1 l00155j610PHl04H+

0.90 l 0.71l l0.3lSAIlP 4l l

, 451101104/96l lH l06H-vM l068-vM l n l00944l580rPl07H+

2.44 l 0.45l l105lSAIIP el l

l 104/96l lE l06H-vM l068-vM in l00944l580rPjo75+ 2.44 l 0.60]

(128lSAIl 11 l

105l101104/96]

lH l048-VM l04H-VM l7 j00425l580FPl0$H+

5.6170+

7.96l 0.58l l0.4lMSIlP 4l l

105l103l04/96l lH l05H-vM l05H-vM l7 l004nl580FPl07H. 2.71To+ 9.77l 0.941 l0.4lMSIlP 2l l

l.104/96l lH 105H.vM l0$H vM l7 100411l580rPj085+ 4.83To+ 20.19l 0.551 10.3lMSIlP 4l l

92l106104/nl lH l04H vM l04H.09El7 l00402l580rPl08H+

1.80To+ 18.81l 0.721 10.5lMSIlP 4l l

u0l106l04/96l l H l04H-vM l04H-vM 17 l00898l580rPl07H+

8.90To+ 14.39l 0.611 10.2lMSIlP 4l l

81l107104/#6]

lH l04H-vM l04H-vM 17 l002291580rPl07H. 5.82 1 0.25l 10.2lSAIlP 4 l l

.123]109104/96l lM l04H vM l04H-VM l7 l00752l580FPl085+ 17.73 l 0.44l l0.2l$AIlP 4l l

u1l1Hl04/96)

.lH 104H.vM 104H.vM l7 l00752l580rPl08H+ 6.55 l 0.42l 10.3lSAIlP 4l l

92l114l04/96l l H l04H.VM l048.VM l7 l00363l580FPl085+ 3.81 l 0.31l l0.4lMAIlP 4l l

_ _ L_J 1.

L_1 1

l__ l l'

l l

L__l l _ l _ L._ ]

ROCKRIDGE THCIDIOLOGIES

CUMUIATIVE REPORT 04/96 BGE, CALVERT CLIFFS. UNIT 1 1

STEAM GENERATOR 1 11 l

PAGE:

2 CP 2

OITTAGE DATA SET CURRENT DATEt 06/06/96 CELECT;ON VARIABLES: Indication Location, Percent TIME:

01:27 23

\\

l

} EXAM l

]

l EXAM EXTEFf l l

l l

l l ROW lLINl DATEl HEAT #l LEG lFROGRAMl AC".UALlEXPl CAL lPROBEj l

LOCATION l VOLTS l MIL lDEGl % lCH lCHNGj l _ _ l --. I I

l_I I__.

l _t i

I __

l I __ l _ L__ l _._ l _ I l

11241116l04/96l 1 H 104H-vM l04u vM l7 l007451580rPl078+ 18.38TO+ 19.801 0.601 l0.2lMSIlP 4l l

11:21118104/96l

} H 104n.vM l04n-ve l7 l00734l580rPl07s.

5.23TO+

6.551 0.58l 10.5lMSIlP 41 l

l1241120104/961 l E l04a-vH jo4H-v517 l00n1l580rPl078+ 9.54 l 0.291 10.3lSAIlP di l

\\ 85l125]Q4/96)

] H l06H 08Hj06H 085l7 l00h16l580FPj075+ 15.04 l 0.63l l0.2lSAIlP 4l l

11011125104/961 1 H l04H-vn 108s-vM l7 l00250l580rPl085. 3.02 l 0.84l l0.1lSAIlP 4l l

l1111125104/961 1 H l04H-vM l04n-vM l7 l00248l58erPj07a+ 6.28 l 0.50l l0.2lSAIlP 4l l

[1151125]D4/96]

)H l03H Y5 l035-VB l7 l00246l580rPl08E+ 10.7770+ 21.78l 0.80ll0.1lMSIlP 4l l

l 90)128104/96j l H l08H-08Hl088-08El1 l00161l610PHlChE+ 4.82 l 0.68l l0.2lSAIlP 4l l

l l

{04/96) lH l 08;I-08Hl 08H-085l1 l00161l610PBl085+ 5.19 l 0.32l l0.3lSAIlP 4l l

) 92l128l04/96) lH l04H VM l04H-VM l7 l00238 l580FP l06p+ 16.3970+ 24.06 l 0.42 l l0.4lMSIlP 4l l

1 1

104/961 lH l088-09Hl08n-09El4 l001801580rPl08E. 21.98 l 0.331 l0.2lSAIlP <l l

l 92l132l04/96]

l N lCfE-VM l085-VM l7 l00207l580FPj088+

4.86 l 0.40l l0.1l8AIlP 4l l

) 74\\138}04/961 lH l04H-vM jo4H-VM l9 l00589l580FPl088+ 1.83 l 0.21l 10.2lSAIlP 4l l

j 821138104/96) lH lTEC TEHl05H-08Bj7 100196l580FPj06H. 2.16T0+ 19.05l 0.19l l0.2lMSIlP 4l

{

s l

\\

)D4/96l lH ITEC-T2Hl05H-08El7 100196l580FPj078+

1.76T0+ 14.91l 0.27l l0.2lMSIlP 4l l

\\

l 104/96l lH l08H.VM l08H-VM l7 l00196l580FPl0$E.

3.0$TO+ 13.59] 0.15l l0.2lMSIlP 4l l

l

}

l04/96) lH lTEC-TEHl0$H-085l7 l00196l580FPl08E+

3.41T0+ 4.61l 0.24l l0.4lMSIlP 4l l

l _. l_I 1

l_I l

l __ i i

I I

l_ L__ L._ L _ !_ _ I NUMBER OF TUBES SELECTED FROM CURRENT OLTAGE:

48 NUMBER OF DATA RECORDS SELECTED FROM CURREN'* OtTIAGE:

62 NO TREND ANALYSIS REQUESTED DATA SELECTION CRITE,RIA:

Indication Location: 01H

-1.00 to 08H p-1.CL (Not at-Supporu-Percent: MAI.SAI.MSI REPORT OPTIONS:

Only examination results matching criteria are ir.cluded ROCKRIDGE TECHNOLOGIES o

~

-,~

- -......,. ~..

... ~. -. - - - -.-

CLDtVIATItT REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERA1VR

11 PAGE:

1 OF 1

}

OUTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: ' Indication Location. Percent TIMER 01:41:48 e

?

I 1.

j EXAM l l

l EXAM EXTENT l-l l

l l

l ROW lLINj DATEl HEAT #l LEG lFROGRAMl ACTUAL lEXPl CAL lFROBEj l

14 CATION l VOLTS l MIL lDEGl t lCH lCHNGl

~

l_l_l-l-

L._I I

l_I I

I 1

l_!_1_l __l_l l121l 55l04/96l'-

l E l04E-VM l045 VM l7 l00730l500FPl095+

l j121l 61l04/96) l E ]O45-VM l045-VM l7 l00751l500PPl09E+. 1.1670+

7.26l 0.47l l0.3l3481lP 4l j

l 5.39 l 0.64) l0.1lSAIlP 4\\

\\

l106l 68l04/56l l 5 ]O45-VM l04B-VC l7 l008$9l500FPl0956 5.6570+ 13.27l 0.46l l0.5lMSIlP 4j l

l106j 10l04/96j j E l04E-VM l045-vu j7 l00%25l580FPl0,95+ 15.29

- l 0.48l l0.2l8AZjP 4) l l

l123l 75l04/96l l E l045 VM l045-W l7 l00702l$40FPj095+

2.80T0+

3.86l 0.38l

{0.6lMsIlP 4l l

l100l 16l04/96l l E 105E-VM l055-VM l7 l00578l58%FPl095+ 4.01 l 0.45l l0.2j8AIlP 4)

)

l l123l 79l04/96l l E l045-VM l045-VM l7 l00914l500FPl095+

3.86TO+

5.21l 0.59l l 76lMSIlP 4l l

l 95l 93j04/96]

'] E ]D88-VM JOSE-VM l7 l00484l580PPl09E+

2.45-l 0.46l l0.2l8AZjP 4j j.

[

l_l._ I I

l _I I

l.__l l

I I

l_1_l.__1._ l__ !

NUMBER OF TUBES SELECTED FROM CURRErrr OUTAGE:

8..

NUMBER OF DATA RECORDS SELECTED FROM CURRENT OtrPAGEr

?

8 I

"#O TRE O ANALYSIS REQUESTED l

DATA SI"ECTION CRITERIAr t

Indicat".on Location: 09H 0.50 to 10H p0,50 (Not at Supports)

I Percer.:r MAI,SAI,MSI REPORT :PTIONSr I

i Only exenination results matching criteria are included l

P I

a l

i ROCKRIDGE TECHNOLOGIES

m_=

.m___~..mmm

._.._ - _ -, _ _m m _- -

.__-m_.-

j CUMULATIVE REPORT j

04/96, BCE, CALVERT CLIFFS. UNIT 1 STEAM GENERATOR a

Il PAGEz 1 OF 3

OlfrAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location. Percent TIME:

01:45:07 2

i i

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

lROWjLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPj CAL lPROBSl LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_I_I I

l_I I

L_1

.I I

I L_.L_ l._ l_1 l

{

l 63l 23l04/96l lN l065-VM l055-VM l11 l00787j 580FPlD5 + 19.96TO+ 20.97l 0.30l l0.5lMSIlP 4l l

l 58l 34l04/96l lH l065-VM l06B-VM l12 l00837l580FPlDE + 12.09TO+ 16.41l 0.57l (0.2lMSIlP 4l l

l 64l 40l04/96}

l M l068-VM l062-VM l11 l00792l$40FPlDH + 4.45

[ 0.64l l0.2lSAIlP 4j l

l 82l 40l04/96l l H l04E-VM l04E-VM j7 l00$83l580FPlVE + 7.3770+ 11.99l 0.82[

l0.6lMSIlP 4l

.l 1

\\105l 41}04/96]

l H l045-VM l045-VM l7 l00593l580FPlVE + 3.33 l 0.37) l0.4lSAIlP 4 l l

l115l 41l04/96l l H l045-VE l04E-VE l7 l00593l580FPlDN + 10.67 l 0.46l l0.4lSAIlP 4l

[

)

l106) 42104/96l l B ]04E-VM l04E VM l7 l00593l$40FPlDE + 2.21 l 1.26l l 0.4 lSAIlP 4 l l

.l102l 4Bl04/96l lE l04B-VM l045 VM l7 l00612l580FPlV8 +

4.2670+

9.52l 0.48l l0.8lMSI(P 4l l

l112l 50)04/96[

}H l04H-VM l04E VM l7 l00611l580FPlVE + 3.42 j 0.44l l0.4lSAIjP 4l l

l106l 52l04/96l J H l058-VM l05B-VM l7 l00687l580FPlDH.+ 15.9870+ 17.45] 0.53l l0.2lM81lP 4l l

\\ 96l 58]04/96l l E l068-VM l06H-VM l7 l00658l580FPjvH +

8.51 l 0.46l l0.2lSAIlP 4l l

l105l 58104/96]

l H lTEC-TEHjoSH VE j7 l00667l580FPlDE + 16.20 l 0.20l l0.4lSAIlP 4l l

}

}

j l04/96l l H jvH VM lVE -VM l7 l00667l580FPlVE+ 7.71 l 0.54l l0.5lSAI!P 4l l

l 81l 59]D4/96l

]H l04H-VM l04H-VM l7 l00307l580FPjvH + 13.60 l 0.65l l0.3lSAIlP 4l l

l 86l 60l04/96) l H l04H-VM l04H-VM l7 l00308 l580FPlVR +. 6.8470+ 10.92 l 0.35 ll0.5lMSIlP 4l l

l 91l 61l04/96l lN l048-VM l048-VM l7 l00646l580FPlVE + 11.92 l 0.38l l0.2lSAIlP 4l l

j l 80) 63104/96l lN l05H VM l05H-VM l7 l00316l580FPlVE +

9.53TO+ 14.04l 0.31l l0.3 lMSIlP 4 l l

i Bij 63l04/96l lH l04H VM l04H-VM l7 l00319l580FPjVM + 10.37T0+ 12.02l 0.46l 10.3lMSI(P 4{

l

}

1103l 63l04/96l lH l04H VM l04H-VM l7 l00647l580FPjDH + 12.56 l 0.89l l0.3lSAIlP 4l l

l 86) 64]C4/96]

lH l0$H-VM l058-VM l7 l00316l580FPlVE +

5.49T0+ 16.33] 0.34l l0.3lMSIlP 4l l

j l 86l 66]C4/96l lH l04H-VM l048-VM l7 l00323l580FPlVH +

3.76T0+ 13.77l 0.27l l0.3lMSIlP 4l l

l102) 66l04/96]

jH l04H.VM l04H-VC l7 l00632l580FPjDB + 11,60T0+ 14.39l 0.51l l0.3lMSIlP 4l l

}.

) 81} 67104/96l l H l04H-VM jodR-VM l7 l00325j580FPlVE +

8.88T0+ 12.17) 0.59l l0.3lMSIlP 4) l l103l 67l04/96l lN l04H-VM l048-VM l7 jo0631l5SOFPlDH + 8.74T0 13.68l 0.51l l0.4lMSIlP 1l l

i.

} 881 68l04/96l lH l04H-VH l04H-VM l7 l00327l580FPlVE + 2.82 l 0.44[

l0.2lSAIlP 4l l

l 96l 68l04/96l lH l04H.VM {04H-VM l7 l00627l580FPlVM +

5.66TO+ 11.48l 0.54l l0.3lMGIlP 4l l

l

\\ 81] 69]C4/96l lH l04H.VM l04H-VM l7 l00332l$80FPlVH +

7.69T0+ 11.05j 0.33l l0.3lMSIlP4l l

l 87l 69l04/96l lH l04H-VM l04H-VM l7 l00333l580FPlVH +

3.48

( 0.56l l0.4lSAIlP 4l l

}

l 86l 70l04/96l l H l04H-VM l04H-VM l7 l00328l580FPlVH +

3.3570+ 14.15l 0.32l l0.4lMSIlP 4l l

4 l102l 70l04/96l lH l04H-VM l04H-VM l7 l00626l580FPlDH + 13.41 l 0.50l l0.2lSAIlP 4l l

I 11121 72104/961 l H ]O4H-VM l04H-VM l7 l00557l580FPlvH +

3.24TO+

5.36l 0.23l l0.3lMSIlP 4l l

l 96) 74l04/96l lH l048 VM l04H-VM l7 l005801580FPlVE +

9.86 l 0.59l l0.2lSAIlP 4 l l

l

' l 98} 74l04/96l l 8 l04H-VM l04H-VM l7 l00579l580FPjVE +

6.36TO+ 15.99l 0.97l l0.5lMSIlP 1l l

3

} 81) 75l04/96l lB l04H-VM l04E-VM l7 l00374l580FPlVE + 10.72 l 0.39]

l0.5lSAIlP 4l l

] 87) 75l04/96l lH l045-VM l045-VM l7 l00383l580FPlVE + 3.24 l 0.61{

l0.4lSAIlP 4l l

l103l 75l04/96l lN l04H-VM*jo4H-VM l7 l00578l580FPlDH +

9.86 l 0.62l l0.4lSAIlP 4l l

j l100] 76]C4/96l lE l05H-VM l05H.VM l7 l00578l580FPlDH +

8.13T0+

8.70l 0.37l l0.3lMSIlP 4l l

l104l 76l04/96l l N l04H-VM l045-VM j7 l00580l580FPlVE + 7.85 l 0.54l l0.2lSAIlP 4l l

4 l103l 77l04/96l l H l04H.VM l04H-VM l7 l00570l580FPlDH +

6.7970+ 13.74l 0.65l l0.5lMSIlP 4l l

l l

l04/96l lB l04H VM l045-VM l7 lC0570l580FPlVE + 2.1770+ 10.78l 0.48l l0.3lMSIlP 4l l

)

l 96l 78l04/96l lH l04H-VM l04E VM l7 l00572l580FPlVE + 2.48 l 0.49l l0.2[SAIlP 4l l

)

l106l 78l04/96l lH l04H.VM l04H-VM l7 l00571l580FPjDE + 15.29 l 0.39l l0.2lSAIlP 4j l

f

]108l 78l04/96l lH lDH -VM lDH -VM l7 j o0570l580FPlDH + 14.05T0+ 18.07l 0.41l l0.5lMSIlP 4l l

s' l 81) 79l04/96l lH l048-VM l04H-VM l7 l00392 l580FPlVH + 10.30 l 0.08l l0.2lSAI{P 4l l

l 91l 79104/96l lB l04H-VM l045-VM l7 l00571l580FPjVE + 3.08 l b.36l l0.3lSAIlP 4l l

L l_1 1

l__.I I

_ L__ l l

l l

l _ i _ L_ L_ I ___ 1 ROCKRIDGE TECHNOLOGIES

CUMULATItfE REPORT 04/9s. SCE, CALVERT CLIFFS, tJNIT 1 STEAM UENERATOR 11 '

PAGEr 2 OF 3

OUTAGE OATA SET CURRI*NT DATE:

06/06/96 SELECT'"DN VARIABLES: Indication 1ccation, Percent TIME:

01:45:07 l

j l EXAM l l _ l EXAH EXTENT j l

l l

l l

IROWlL*Nl DATEl HEATS l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl t lCH lCHNGj l_._I _ l-I l_!

I l __I l

I l

l _ i __. l _ i _ l _ I 1103l s1104/9si l x lo4a-vM loan-vM l7 lo0544l5s0rPIDs + s.30To+ 12.3ol 0.53l lo.2lMsIlP 41 l

-.l e7l s3lo4/9sj l H jo4H-vM l045-vM l7 lco392lss0FPlVR + 9.90

{ 0.40l l0.2l8AIlP 1[

]

1103l e5lo4/9si l a lean-vM l04s-vM l7 l00s34l5:0FPlvu + 3.70To. lo.94l 0.54l l1.5lMsIIP <l l

l1o5l 87l04/9sl l R l04H-vM l04M-vM l7 l00bl9l5:0FPlDJI+ 7.21T0+ 17.43l o.4sll0.4lMSIlP4l l

l 9si esl04/9st l u loan-vM l04s-vM l7 l0051115 0rPlva + s 94 l 0.71l l0 3lSAIlP 4l j

l s3l s9lo4/9sl l u l04m-vM jo4m-vM 17 l0o39sl5sbrPiva + 7.s9 l 0.# 9l lo.2{8AIlP 4l l

11031 89104/951 I n l04s-vM lois-vM l7 1005csl5soFPlDE +

7.7670+ 14 5l 0 41l l0.5lMSIlP 4l l

l1o4l 90lo4/9sl l n 104n-vM l04a-vM 17 'l0050sl5:0FPlD$t+ 9.s070+ 10..sl J.37l l0.2lMSIlP4l l

l l

lo4/9sl l a l04n-vM loes-vM l7 - lCoS05l5:0rPjvn + ;.75To+ s.04] 0.3sl

[0.2lMSI(P 4 l l

l s3l 91]o4/9sl lE l04H-vM lDE -vM l7 jo045sl5:0FPjvH.+ 3.7s l 0.74l lo.3lMAIlP 4l l

-l.svl 91l04/9sl l a l04m-vM lois-vM 17 loo 4csiss0FPlvn + 9.s:To+ 10.01l o.47l l0.3lMSIlP %l l

l 91l 911c4/9sl l u l07a-vM l07s-vM l7 l00502l5s0FPlva + 2.s0To+ 11.00l o.50l lo.slMSIlP 4l l

l sej saiO4/9si l n 10ss-vM l05a-Da 112 lcos4sjss0rrlDH - 5.51 l

o'. sal l0.2lsAIlP4l t

l 911 93to4/9s]

l n loon vM l04s-vM 17 l0049315sorPlva + 2.91 l o.44l l0.5'sAIlP el l

l 92]100!c4/9sl l H l048-VM l04H VM l7 lCo429l5s0FPjvH + 12.2170+ 21.19l 0.2sl l0,2lMSIlP 4l l

l 94jlo0l04/9sl l N lo4H-VM l04H-vM l7 [o0429l5:0FPlDH + 2.40 l 0.5sl lo,3lSAIlP 4l l

j 9sl1C0!a4/9sl lH lo4H-vM l04H-vM l7 l00430l5soFPlvH + s.03

,l 0.51l l0.3lSAIjP 4{

l-l10s)103'04/9sl l E l04H-VM l04H.VM l7 l00429l5s0FPlvH +

5.7970+

s.s0l 0.39l l0.4lMsIlP 4l l

l 91l101J04/9sl lH l04H-VM lDH -vM j7 l00727l5:0FPlvH +

1.73TO+

3.csl 0.44l l0.3lMsIlP 4l l

l3o0l1C4l04/9sl l E l04R-VM lo45-vM l7 lo0727l5 0FPlDH + 7.o7T0+ 11.s4l 0.35l l0.2lMSIlP 4l l

l l

104/9sl l n 104n-vM l04n-vM 17 l00727l5 0FPlvH + 2.asTo+ 11.70l o.291 l0.5lMsIlP 4l l

l12sl104:04/9si l H l04H-VM l04H VM l7 l00s79l5:0FPlDH + 13.s2T0+ 20.29l 0.35l l0.2lMSIlP 4{

l l11s!113 04/9si lH l04u-vH l04n.vM 17 10o752lssorPlDH + 22.s3 l 0.41l l0.2lSAIlP 4l l

l125l111!04/$sl lH l04H-vM [04H-vM l7 l00752l$soFPlv' + 22.s0 l 0.44l l0.2lSAIlP 4l l

d l ssl112{04/9sl l H lo4H-vM l04H-vM l7 l0o22sl5sCFPlvH + 2.51 l 0.7sl l0.3lSAIlP 4l l

l 90l112:04/9sl lH l04H vM l04H-vM l7 l0o3s9lss0FPlvH + 1s.17 l 0.s1l l0.2lSAIlP 1l l

} e41114:04/9sl lH lots.vM l04u-vM l7 lo0227l5sorPlvn + 14.727o+ 1s.43l 0.45l l1.1lMSIlP 4l l

l 92l114l04/9s) l H l04H-VM l04H-vM l7 lo03s3lss0FPlvH + 1s.03 l 0.43l j0.2lMAIlP 4l l

l 94!114'04/9s) l R l07H-vH l07H VM l7 l003s1l5:0FPlDH + 10.75 l 0.47l

[0.slSAIlP 4l l

l 04/9sl l E jo7H-VM l07H-VM l7 l003s1l5:0FPjVH +

2.96T0+ 14.59l 0.32l l0.9lMsIlP 4l l

1 9 t n $ : 04/9s l l c l0sC-Osnl0sc 0snl2 l00t5sl5sePnlvM - 2.9s l 0.97l l 77lsAIIP 41 l

1105ln7:04/9st

.l H l0sn vM l0$u-vM 17 loo 7141ssorPIDs + 15.e5 l 0.4sl 10.2lsAIlP 1l l

)

I

04/9si i n 105u-vM l0sa-vM 17 lo0714l5sorPlvE + 3.15 l 0.29l lo.3lSAIlP C{

l l110l122104/9sl lH l04H-VM l04H-vM l7 l00254l5:0FPlDH + 33.31 l 0.50l l0.3lSAIlP4l l

l e5l123104/9sl l m losa-vM loss-vM l7 l00219lssorPlva + 12.59 l o.40l l0.2lsAIlP 4l l

l 99l125jo4/9sl lH l04H.VM l04H-vM l7 l002s1l$s0FPlvn + 2.43 l 0.4sj lo.1lSAIlP 4l

(

l101l125:04/9sl l n lo4a-vM 104n-vM l7 lCo25ol5sorPlva +

5.42 l 0.s3l lo.2lsAIlP el l

l e5l127l04/9sl l n 10ss-vM l0ss-vM l7 l0o21sl5sorPtvs + 3.30To+ 4.21l o.s0l

[o.2lMsIIP 11 l

l1c3 l127 : 04/96 l l n 104n-vM l04E-VM j7 (o024sl5soFPlDE + 12.95 l o.5ol lo.3l5LI(P 1l l

l1c51121 lo4/9s l lE l045.VM l04E-vM {7 l00715l5:0FPjDR + 11.o370+ 13.59) 0.44l jo.3lMSIlP4l l

l1131127}04/9s) l N l04H vM lo4H-vM l7 lCo243l$soFPlDH +

3.09T0+

4.sol 0.501 lo,9lMFIlP4l l

l2131129:04/9sl l u l04u-vM l04u vM l7 10024115:0rPlDu + 10.s7 1 0.30l l2.0lMsIlP 4l l

l 991131 04/9si i a loan-vM loen-vM l7 l0o21115:0rPlva + 11.12 l 0.4sl lo.2]SAIlP4l l

l s2l13:IO4/9sl l a {0su-vM l0ss-vM 17 l0019sl5sorPlvn +

3.01To+ 17.30l 0.45l l0.2lMsIlP 4l l

L__l a l

l __. I l

L._ I I

I I

l _ I __ l._ l _-_ i _._ I ROCKRIDGE TECHNOLOGIES

^

CUMUIATI'JE REPORT I

I 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

3 OF 3

OLTTAGE DATA SET j CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME:

01:45:07 NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE:

83 NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

89 NO TREND ANALYS15 REQUESTED DATA SELECTION CRITERIA:

Indication Location DH 2.00 to DC p2.00 (Not at Supports)

Percent: MAI, SAI,MS !

REPORT OFTIONS:

Only examination results matching criteria are included j

l l

l i

1 I

l LOCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11

+

PAGE:

1 OF 1

'JTAGE DATA SET

CURRENT DATE:

06/06/96

, ELECTION VARIABLES: Indication Location, Percent TIME:

01:59:03

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA-Zndication Location: 09C bO.50 to 10C 0.50 (Not at Supports)

Percent: MAI,SAI,MSI REPORT OPTIONS:

Only examination results matching criteria ar,e included j

e ROCKRIDGE TECm40LOGIES

CUMULATI1TE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

'UTAGE DATA SET

CURRENT DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

01:57:56

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 01C 1.00 to 08C, 1.00 (Not at Supports)

' Percent: MAI,SAI,MSI I

REPORT OPTIONS:

Only examination results matching criteria are included e

i ROCKRIDGE TECHNOLOGIES

l I

CUMULATIVE REPORT 04/9s BGE, CALvERT CLIFFS, UNIT 1 11' STEAM GENERATOR r

PAGE:

1 OF 1

OWAGE DATA SET CURRENT DATE:

Os/06/96 l

- SELECTION VARIABLES: Indication Location, Percent TIME 01:35:11

' i I

i 1

l ExAMI I

I EXAM EXTENT l l

-l l

l l

lRcwlLIsl DATElxEATslLEoIPROaRAMI ACTuaLIExPl CAL lPROBEl LOCATION tv0LTslMILloEGl t ICn lCunal l __ i_ I I

L._I I

l_l l

l 1

L _ L_.L_l _ l 1

l 7ei as[04/ssl l s l04u vu 104s.vu l7 l002s715:0rPl08a*12.s3 l 0.7sl 10.slPPzlP Si t

I ss; 30]O4/ssi l m l04a..vu l04s-vu ls l00472l5sorPl07a+ 1s.7s

- l 0.47l l0.5lPPzlP 5l

.l

-l s8{'3sl04/ssl l 5 l045 vu l048-vu ls l00472l500FPl08H+ 3.29 l 0.s7l l0.8(PPI{P 5l l

j

] <si 4:104/ssi l u losa.vu 10su.vu 111 100'is115:0rP10ss+

4.07 l 0.ssi 10.2lPPzlP Si i

l 1

l04/ssi l n 10sa.vu psu.vu l11 l007s1l5:0rPl08s. 7.30 l 0.47l 10.2lPPzlP 5l l

l sSI 42j04/ssl l N l045.vu l045-vu 19 l00472l550FPl075+ 1.11 l 0.42l l0.4lPPIlP 5l l

l ssi 44l04/sst i n 10ss-vu l0su.vu l11 l00791l$30FPl08M+ 1.94 l 0.83l l0.2lPP!lP 5l l

l 44 s4104/ssl 1 s l0su.vu l0sn.vu l12 100:4715:0rPl05a+ 22.s5 1 0.27l 10.5lPPztP 51 I

l04/ssi l n l0suavu l0su.vu 112 l00:47l580FPl07N+23.83 l 0.44l l0.5lPPIlP 5l l

l 52,102l04/9sl lH l0sH-vu l078.DH l11 l009s4l580FPjo7Jt+ 1s.41 l 0.7sl l 81lPP1{P Sl l

l112 102l04/9sl

.l M l04H.YR l04H.vH l7 l00420l580FPl08H+ 18.51 l 0.45l l0.7lPP!lPSl l

l s1 inl04/ssl l n 104u vu l03u.Vu l7,l00228l580FPl08H+ 13.78 l 0.53l l0.2lPP1lP Sl l

l 85.127l04/96l lH l08s.vu l08H.vu l7 l0021sl580FPl08H+ 1s.32 l 0.7sl l0.4lPPIlP 5l l

In4 12 j04/sst I n 104s vu l04a vu l7 l0024215:0FPl08H+

9.90 l 0.95l

]O.2lPPIlP 5l l

l _.__ l

]__:

'l l_l l

l I

L_1_ L_.L_l t-NDGER OF TUBES SELECTED FROM CURRENT OUTAGE:.

12 ND3ER OF DATA K.ICORDS SELECTED FROM CURRENT OWAGE:

14 NO U.END ANALYSIS REQUESTED DATA SELECTION 3ITERIA:

Int :stion loca:Lon: 01H 1.00 to 08H pl.00 (Not at Supports)

Per:ents PPI RETU T Ol*TIONS:

On?/ examinatict results matching criteria are included I

i i

e i

ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR -

11 PAGE:

1 OF 1

OLTIAGE DATA SET n CURRENT DATE:

06/06/96 SELIOTION VARIABLES: Indication Location, Percent TIMES 02:21:46 j

l l EXAM) l l EXAM EXTENT l l

l j

l l

l ROW lLINl DATElHCATNl LEG l PROGRAM] ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l

l_I I

L__I l

l_l l

I

_l l _ I_ _I _ I _ t.

{103l 53l04/96l l M l048-DE l045-DE l7 l00607l540FPl09H+ 12.53 l 1.18l l0.5lPPIlP 5l

__l l

l l

l04/96l l 5 l045-DE l04E-DE l7 l00687l580FPl09E+ 16.53 '

l 0.88]

l0.6lPPIlP 5l l

l1001 76]C4/961 l M l055-VM l058-VM l7 l00578l580FPj095+ 12.22 l 1.09l l0.3lPPIlP 5l l

l l

l04/96l lB l05E-VM l055-VM l7 l00578l580FPl,09H+ 13.21 l 0.75l l0.2lPPIlP 5l l

l102l 78l04/96l lH l045-VM l048-VM l7 l00573l580FPl095+ 13.43 l 0.96l l0.2lPPZlP 5l l

l l

l04/96l l E l045-VM l045-VM l7 l00573l500FPl098+ 17.10 l 1.24l l0.2lPPIlP 5l l

l100l 88l04/96l l 5 l045-VM l045-VM l7 l00511l580FPl098+ 11.55 l 1.57l l4.5lPPIlP 5l l

l105] 95j04/96j l E l045-VM l045-VM l7 l00478l580FPj69H+ 19,76 l 0.77l l0.8lPPIlP 5l l

l 1

l04/96l lH l04H.VH l04E VM l7 l00478l580FPj09H+20.37 l 1.15l' l0.5lPPIlP 5l l

l104 104l04/96l lH l04H-VM l048-VM l7 l00412l580FPl0JH+ 12.60 l 0.64l l0.4lPPIlP 5]

l l

l04/96l l H l04H-VM l04H-VM l7 l00412l580FPl09H+ 17.85 l 0.38) l0.3lPPIlP 5l l

l105 107l04/96l l H l04H-VM l04H-VM l7 l00396l580FPl09H+ 17.59T0+ 20.76l 0.73l l0.1lPPIlP 5l l

l105 109l04/96l l H l04H-VM l04H-VM l7 l00390l580FP j o9H+ 19.55 l 0.49l l0.6lPPIlP 5l l

l105 115l04/96l l H l04H-VM l04H-VM l1 l00352l580FPl09H+ 18.76 l 0.80l l0.5l9PIlP Sj

{

l 98 140l04/96l lH l 04H-VM l08H-VM l7 l00339l580FPj09H+ 11.85 l 0.57l l0.2lPPIlP 5l l

-l100 140j04/96l l H -l08H-VM l08H-VM l7 l00194l580FPl09E+ 12.93 l 0.61l l0.3lPPIlP 5l l

L_

_ I l

1._

I l

l_I I

I I

l _ l _l_I___ I I

NDSTR OF TUBES SELECTED FROM CURRENT OITTAGE:

11 IOGIR OF DATA RECORDS SELECTED FROM CURRENT CUTAG83 16 NC M ND ANALYSIS REQUESTED

' DATA 5 ELECTION CRITERIA:

Ir.h :ation Location; 09H p0.f.0 to 10H p0,50 (Not at Supports)

Per:ent PPI REFU

  • OPTIONS:

On' ' examination results matching criteria are included ROCKRIDGE TECHNOLOGIES

CUMUIATIVE REPORT 04/96, DGE, CALVERT CLIFFS. UNIT 1 STEAM GENERATOR 11 PAGE:

1 OF 1

OtTTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME:

02:26:09 l

] EXAM l j

j EXAM EXTENT l l

l l

l l

l ROW,LINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION JVOLTSlMILjDEGl % lCH lCHNGl l- -l l

l-l I

l_l l

l l

l_l-l_l_l_l l 68 22j04/96l l H l04E-VM l045-VM l9 l00454l540FPlDH+ 5.33 l 0.74l l0.3lPPIlP 5l l

l 55 51l04/96l lE l065.VMl065-VMl12 l00850l500FPjDu +

2.49 l 0.80) l0.4lPPIlP 5l l

j l 75: 63l04/96l l E l045-VM l045-VM l? l00316l580FPjvH + 14.22 l 0.34l l0.8lPPIlP5l l

l l102 78l04/96l l H l04M-VM l04E-VM l7 l0d573l58CFPlDR + 3.79 l 0.88l l0.5lPPZlP 5l l

l l04/96l l N l045-VM l045-VM l7 l00573l58;P2 ;ou + 4.75 l 0.45l l0.3lPPIlP 5l l

i l 73 - 81]04/96l l H l045-VM l045-VM l9 l00497l5fCFPlDH + 3.80 l 0.73) l0.3lPPIlP 5l l

l123' 87l04/96l l H lC55-VM l055-VM l7 l00918l580FPjDE+19.19 l 0.56l l105lPPIlP5l l

l 80 100l04/96l l M l04M-VM l038-VM j7 l00414l580FPlD'E + 3.54 l 1.03l l0.3lPPIl 2l l

. l 82 100l04/96l l E l04H-VM l03H-VM l7 l00413l500FPlDH + 2.55 l 1.01l l0.5lPP!lP 5l l

l100 104l04/96l l N l045-VM l04H-VM j7 l00727l580FPlDE

  • 3.19 l 0.75l l0.5lPPIlP 5j l

l105 107l04/96l lH l04H-VM l04H-VM l7 l00396l580FPjDH + 2.13 j 1.08l l0.3lPPIjP~5l l

l 64 110l04/96l lH l06H.VM l065-VM l11 l00809l580FPlDH + 3.26 l 0.66l l0.5lPPIl 2l l

l 68 110l04/96l l E l04H-VM l04H-VM l9 l00559l580FPlDH + 4,22 j 0.52l l0.5lPPIlP 5l l

l 92 114 l04/96 !

l H l04H VM l04H-VM l7 l00363l580FPlDH + 5.13 l 0.69l l1.2lPPIlP 5l l

l 90 116l04/96; l H l0$H-VM l05H-VM l7 l00351l580FPlDH + 5.89 l 0.64j l1.8lPPIlP $l l

l107 121l04/96!

l H l04H-VM l05H-VM l7 l00256l580FPlVH + 6.99 l 0.77l l0.2lPPIlP $l l

l 85 127lD4/96!

lH l00H.VM l08H-VM l7 l00216l580FPlDH + 4.74 l 0.79l l0.3lPPIl 2l l

l $* 128l04/96 !

lH l04H-VM l04H-VM l7 l00239l580FPlDH + 5.11 l 0.80j 10.2lPPIlP 5l l

l l04/96:

lH l00H-09El08H VH l7 l00182l580)PlDH + 5.51 l 0.79l l.3lPPIlP 5l l

l 55 129l04/96l lH l04H-VM l04H-VM l7 l00238l580FPlDH + 4.00 l 1.49l l0.4lPPIjP 5l l

l102 134l04/96!

lH l08H VM l08H.vM l7 l00202l580FPlDH + 3.79 l 0.09]

l0.2lPPIlP 5l l

l 83 145]O4/96l l H l04H.VM l08H-VM l7 l00314l580FPjpH +

3.68 l 0.77l l0.9lPPIlP Sj l

l 71 153l04/96.

lH lO5H-VM l05H-VM l9 l00597l580FPlVH + 3.16 l 0.81l l0.4lPPIlP $l l

L_ _-._1 l_I l

l_I I

I I

L_ I_ I_ I_-._ l--__ l NEXEER OF TUBES SELECTED FROM CURRENT OUTAGE:

21 ND'3IR OF DATA RECORDS SELECTED FROM CURRENT OtTTAGE:

23 NO ""F,.END ANALYS;S lie;)UESTED CATA SELECTION ~RITERIA:

Int:stion loca:1on DH V,00 to DC

>2.00 (Not at Supports)

Per:ent PPI REP M OPTIONS:

On2/ examinatien results matching criteria are included

w. %

E ROCKRIDGE TECHNOLOGIES

i CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

UTAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIMEt 02:26:58

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 09C 0.50 to 10C p0.50 (Not at Supports)

Percent: PPI REPORT OPTIONS:

Only examination results matching criteria are included l

l i

l l

\\

i l

ROCKRIDGE TECHNOLOGIES l

l

=

.~

i l

1 CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 I

STEAM GENERATOR

11 PAGE:

1 OF 1

'UTAGE DATA SET CURRENT

+

DATE:

06/06/96 ELECTION VARIABLES: Indication Location, Percent TIME:

02:27:36 I

1 1

l

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 01C 1.00 to 08C.bl.00 (Not at Supports)

Parcent: PPI REPORT OLTIONS:

Only examAnation results matching criteria are included l

l l

~

i l

1 l

I t

i j

l 4

l l

l l

l i

l l

\\

ROCKRIDGE TECHNOLOGIES

, _ _.,_ - _ _ _. -... _ - - _. - - - - ~ ~ ~ - - -

a.

_.2 m ____.._

.m _ a _ _ -

.m_..m m m

l CUMULATIVE ItEPokT 04/9s, BGE, CALvERT CLIFFS. UNIT 1 l

l STEAM CENERATOR t 11 PAGEt 1 OF 2

C7 A0E DATA SET s CURRENT DATEt 06/06/96 SE.ICTJUN VAMABLES: Indication location, Percent TIMEt 02:29:18 f

J l

l EXAW l

l EXAM EXTENT l l

l l

(.

l l G lLINI DATElHEAT8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION jVOLTSl MIL lDEdl t lCH lCicvGl L._.L_.)

F l_I 1

L._I I

l l

l-_.L _ I__ L_ L._

I l nl 13l04/96 L lH l0sH-vu l06s-vu l12 1008251580FP!07H+ 24.88 l 0.5sl 10.21sAIlP4l l

I 18l 28l04/961 lN l04H vM l04M vM l7 l00267l580FPl08H+12.s3 1 0.78l l0.slPP!lP 5l l

l s8i 30104/9s!

lH l04x-vu 10am-vu 19 l00472l580rPj07s+1s.7s l 0.471 10 5ln!lP 5l l

l101] 31104/9o lH l04s-vu 104m.vu 17 l00b41580rrl0,7H+

s.5s l 0.s31 l0.2lsult al l

l nl 32104/96:

l H l04m-vu l04m-vu 17 l 002731 s S 0rPl 08a.15.2 s l 0.74l 10 21sulP 4l l

l 68) 3sl04/96:

l H l045-VM l045-VM l9 l00472158bFPj085+ 3.29 l 0.s7{

l0.8lPPIlP 5l l

l 821 40104/96-l H l04m vu 104s-vu 17 l00283l580rPl00s. 2.6sTo+ u.ssi 0.42l l0.3 lus!lP 4l l

I 66i 42104/9s l H 10sH-vu l0sH-vM 111 l00791l500rPl0hH+ 4.07 l 0.sSI l0.2lnIlP si l

i j

104/96 lH l0sH-vM l0sH.vM l11 l007911580FPl08H+ 7.30 l 0.47l l0.3lPPIlP5l l

l Gli 42l04/96 I E 104H-vM l04H-vM l9 l00472l580FPl07s+ 1.11 l 0.42l ' l0.4lPPIlP 5l l

l104l 42l04/96 l N l04H vM l04H.vM l7 l00594l580FPl07H+ 15.87 l 0.35l l0.2 lsA!lP 4l l

l 66! 44l04/96 lH l06H-vM l06H.vM l11 l00791l580FPl08H+ 1.94 l 0.83l l0.2 lPPIlP 5l l

!101 45104/96 lN l04H vM 104H vM l7 l00599l580FPl06H+ 20.0370+ 23.64l O'45l l0.4lMsIlP 4l.

l 69 53 l 04 /n lH 104H-vM l04H-vM 19 l00482lsS0rPl07H.

7.32.

l 0.73l 10.31sAIlP <[

l

.221 55l04/n lH 104H-vM l04H.vu 17 l00730l580rP1078+ 17.1sTo+ 24.80l 0.541 l0.3;msIlP 4l l

l04/96 iH 104H-vu 104H.vu l7 l007301580rPjo8H+ 1s.92To+ 21.15l 0.54l l0.2 tusIlP 4l l

u0 56l04/96 iH 105H.vu 105H.vu 17 100730l580rP108H. 14.05To+ 18.031 0.6sl l0.2imsIlP 4l l

}121 61l04/96 lH l04H vH l04H.vM l7 l00751l$80FPl07H+ 11.51 l 0.s0l l0.2 ISM lP 4 l l

l' l04/96 l H i O4H.VM l04H-vM l7 l00751l580FPl08H+ 14.02 l 0.76l l0,5 lSMlP 4l l

{106 6sl04/96 lH l08H.09El088 09Ej1 l0015sls10PHl08H+ 16.15 l 1.35l l0.3 l5A!lP 2l l

43 h7]O4/96 lH !06H vM l06H.vN l11 l00974l580FPl06H+ 14.64T0+ 17.38) 0.55l l 79lMsIjP 4l l

i l04/96 lH !O6H.vu l06H.vu l11 l00974l$80rPl06H+ 15.70 1 0.47l l117 xsIl 1l l

85 s9l04/96 lH !04H.VM l04H-vM l7 l 00327 l 580FP l08H+ 10. 83T0+ 12.37 l 0.s0l.. l0.4,MSIlP 4 l l

i i121 69l04/96 iH l04H-vM l04H-vM l7 l00767l580FPj08H+

6.18T0+ 11.59l 0.29]

.l0.3 'MSIlP 4 l l

!121 71l04/96 lH l04H-vM l04H vM l7 l00708l580FPl07H+

6.12' l 0.451 l0.1]SAIlP 4l l

j

!n 74l04/n lH iO4H.vu l04H.vM l7 l00579l580rPl07H 11.287o. 1s.96} 0.55l 10.1ixsIIP el l

l.

104/n lH.048-vu l04H-vM l7 l00579l580FPl08H+

9.81TO+ 18.s7j 0,98l

'j0.2'MSIlP 4l l

't23 77104/96 lH iO4H-vu l04H-vM l7 l00697l580rPl06H.

8.30To+ 23.401 1.35l l0.3 :xsIlP 21 l

i l04/96 lN l04H vM l048-VM l7 l00697l580FPl088,1*e.64tQ 15.92 l 0.84 l l0.2iMsIlP 1[

l l123 79l04/96 lH l04H.vM l04H.vM 17 l00914l580FPl06H+ 28.3170+ 24.1.'l 0.57l l 89 'MsIlP 4 l l

l 84 82l04/96 iH iO4H.07Hl04H-07Hl7 l00392l580FPl06H+ If. 19 l 0.59l l0.3 j SAIlP 4 l l

! 81 85l04/96 lH 104HavM l04H-vM l7 l00398l580FPl068+ 1s.52 l 0.40l l0.2 SAIjP 4 }

l I

l04/n lH :04H.vu l04H-vM 17 l 00n8 l 580rP107H+ 7.387o+ 13.08) 0.37l 10.3 ;msI(P 4l l

128 86l04/96 lH ;06H-07Bl06H-07El1 l00918l580FPj06H+ 11.0070+ 15.79l 0.s7l l 97,xsIlP 4l l

l 56 e2l04/n lN 106H.vu l06H-vM lM l00n 2l580FPl07H+ 14.8070+ 1s.97) 0.41l l 71!NSIlP 4l l

lu5 nl04/96 lH 105H-vu l05H-vu l7 10 n u l580rPl08H. 2.80To+ 5.nl 0.s0l 10.2 :xsIIP 4l 1

i s.

94104/n lH 106H-vu l06H vu (12 l00:47l580rPl0?H+ 22.9s 1 0.27l l0.s PrIlP 5l l

l l

.l04/96 l H l06H-vM l06H vM l12 l00847l580PPjo7H+ 23.83 l 0.44l l0.5:PPIlP 5l l

. e5 95l04/96 lH IO4H-vu 104H-vn l7 l00407l580rPl08H+ 2.07To. 5.46l 0.391 10.2 usIlP 41 l

l s0 96lc4/96 lN 1065-vu 106H-vu l12 l00853l580FPl07H+ 9.197o+ 1s.14l 0.43l l2.1!xsIlP 1l l

l 45 101l04/94 lE l06H-vM l06H-vM l11 l00944l580FPl078+ 2.44 l 0.45l l105 f SAIlP 4l l

i l04/n l H 106H-vu ju H-vM l11 l00n4l580FPl07H+ 2.44 l 0.s0l l118;SAIl 1l l

11c5 101104/9s lH iO4H-vu l04H.vH l7 l00425l580FPl08H+ s.s1TO+ 7.961 0.58) l0.4 ;Mf!lP 4 l l

l 52 102l04/96 lH l06H vM l07H.DH l11 l00964lsSOFPlD7H+1s.41 l 0.7sl l FliPPIjP 5j l

t 1112 102104/n l N f04H-vH l04H vH 17 l00420lsB0rPl08H+ 18.51 l 0.451 10.7iPPIIP Si l

l i __. _ l -

la l

L_I l

l 1

l_ L._ _ _ L_1.___ l f.

ROCKRIDGE TECHNOLOGIES l

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS. UNIT 1 STEAM CENERATOR

11 PAGE:

2 OF 2

l OUTAGE DATA SET 1 CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIMEt 02:29:18

)

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

j l ROW lLINl DATEl HEAT #l LEG lPROGRAMj ACTUAL lEXPl CAL l PROBE l

'OCATION l VOLTS l MIL lDEGl t lCH lCHNGl 1._ i _ I I

L _I I

l_l l

1 i

L_ l_._ L __l _ l__ _ l l105l103l04/96l lH l05H.VM l05H-VM l7 l00411l580FPl07H+ 2.7170+

9.77l 0.94l l0.4lMSIjP 2l l

i

)

l l04/96l lH l0$H.VM l05H-VM l7 l00411l580FPl08H+

4.8370+ 20.19l 0,55]

l0.3lMSIjP 4l l

l l 92l106l04/96l lH l04H.VM l048-09Hl7 l00402j580FPl085+

1.8070+ 18.81l 0.72l l0.5lMSIlP 4l l

i l130l106]D4/96l lN l04H.VM l045-VM l7 l 00% 98 l 500FP l 07H+

8.90T0+ 14.39l 0.61l l0.2 lMSIlP 4 l l

l 81l197l04/96l l E l04H VM l04H-VM l7 l00229l580FPl07H+ 5.82 l 0.25l l0.2lSAIlP 4l l

l123l109l04/96l lB l04H VM l04H-VM l7 l00752l58tFPl08H+ 17.73 l 0.44l l0.2lSAIlP 4l l

l 81l111l04/96l lH l04H-VM l03H-VM l7 lOO228l580FPl08H+ 13.78 l 0.53l l0.2]PPIlP 5l l

3 l121l111]D4/96l l B l04H-VM l04H.VM l7 jo0752l580FPl03H+ 6.55 l 0.42l l0.3lSAIlP 4l l

l 92l114l04/96l l H l04H-VM l04H-VM l7 l00363l580FPj08H+ 3.81 j 0.31l l0.4lMAIlP 4l l

l124l116l04/96l lH l04H.VM l04H-VM l7 l00745 l 580FPl 07H+ 18.3 8TO+ 19. 8 0 l 0.6 0 l l0.2 lMSIlP 4 l l

l122l118l04/96l l T. l045 VM l04H-VC l7 l00734l580FPl07H+

5.23T0+

4.55l 0.58l l0.5lHSIlP 4 l l

f l1241120l04/96l lH l04H-VH l04H-VM l7 l00771l580FPl075+ 9.54 l 0.29]

l0.3lEAIlP 4l l

l 85l125l04/96l l H l06H-08Hl06H-08Hl7 l00216l500FPl07H+ 15.04 l 0.63l l0.2jsAIlP 4l l

l101l125l04/96l lH l04H-VM l08H.VM l7 l00250j580FPl08H+ 3.03 l 0.84l l0.1lSAIlP 4l l

l111!125l04/96l lN l04H-VM l04H-VM l7 l00248l580FPl07H+

6.28 l 0.50l l0.2lSAIlP 4l l

l115l125l04/96l l H l03H.VH l03H-VH l7 l00246l580FPl08H+ 10.77TO+ 21.78l 0.80l j0.1lMSIlP 4l l

l 85l127l04/96l lH l08H-VM l08H.VM l7 l00216l580FPl08H+ 16.32 l 0.76l l0.4lPPIlP 5l l

l 901128l04/96l lH l08H-08H]08H-08Hl1 l00161l610PHl08H+ 4.82 l 0.68l l0.2lSAIjP 4l l

l j

l04/96l lN l08H-08Hl0$H-08Hl1 l00161l fit *qjo8H+ 5.19 l 0.32j l0.3lSAIlP 4l l

l 92l128l04/96l lH l04H-VM l04H.VM l7 l 00238 l 580FPl06H+ 16.39TO+ 24.06 l 0.42 l l0.4lMSIlP 4l l

)

l l

l04 /96 l lH l08H-09Hjo8H-09El4 l00180l580FPl08H+ 21.98 l 0.33]

l0.2lSAIlP 4l l

l114l126l04/96l lH l04H.VM l04H-VM l7 l00242l580FPl08H+

9.90 l 0.95l l0.2lPPIlP 5l l

l 92!132l04/96l lH l08H-VM l08H-VM l7 l00207l580FPl08H+

4.86 l 0.40l l0.1lSAIjP 4l l

l 74l138l04/96l lH l04H-VM l04H-VM l9 l00589l580FPl08H+

1.83 l 0.21l l0.2 lSAIlP 4 l l

l l 82l138l04/96l lH lTEC-TEHl05H-08Hl7 l00196l580FPjo6H+

2.1670+ 19.05l 0.19]

l0.2 lMSIlP 4 l l

l l04/96l lH lTEC-TEHl05H-08Hl7 l00196l580FPl07H+

7.76T0+ 14.91l 0.27l l0.2lMSIlP 4l l

l l

l l04/96l lH l08H-VM l08H-VM l7 l00196l580FPl08H+

3,05TO+ 13.59l 0.15l l0.2lMSIlP 4l l

l

[

}04/96l lH lTEC-TEHl05H 08Hl7 l00196l580FPjo8H+

3.41T0+

4.61l 0.24l l0.4lMSIlP 4l l

IJ_ I I

L_I I

l__l l

l l

L_ L_L_L l_I NUMIER OF times SELECTED FROM CURRENT OUTAGE:

f> 8 fMMR OF DATA RECORDS SELECTED FROM CUP' RENT OUTAGE:

73 NO T?END ANALYSIS PEQUESTED DATA SELECTION CRITERIA:

Indication Location: 01H pl.00 to 08H pl.00 (Not at Supports)

Nrcent : MA1.PPI,SA1,MSI REPCRT OPTIONS:

Only examination results matching criteria are included ROCKRIDGE TECHNOLOGIES 4

CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, tJNIT 1 STEAM UENERATOR 2 11 PAGE:

1 OF 1

OUTASI DATA SET s CURRENT DATE:

06/06/96 SELEC"~*DN VARIABLES: Indication Location, Percent TIME:

02:50:33 l

i l EXAM l l

l EXAM EXTENT l l

j l

l l

lROWi *Nl DATElHEATNl LEG lFROGRAMl ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_4_I I

l

_I I

l_.l i

I I

l-._1-._ l_L l l

l103] 53l04/96}

l H l04H-DE l04H-DK l7 l00687l580FPl09E+ 12.53 l 1.18l l0.5lPPIlP 5l l

l l

l04/96l l E l048-DE l04H DE l7 j00687l580FPl095+ 16.53 l 0.88l j0.6lPPIlP Sj l

l121l 55l04/961 l N l04H VM l045-VM [7 l00730j580FPl098+

1.1670+ 7.26l 0.47l l0.3lMSIlP4l l

l1211 61l04/96l l N l04H-VM {045-VM l7 l00751l580FPl095+ 5.39 l 0.64l l0.1lSAIjP 4l-l l1061 68104/96l l x l04a-vu l04s-vC 17 100899l580rPld95+ 5.65To 13.271 0.46l 10.5lMSIlr 4l 1

l106] 70l04/96l l E l04H-VM l045-VM l7 l00625j540FPl098+ 15.29 l 0.48l l0.2lSAIlP 4l l

l1231 *sie4/96l l E l045-VM l04E-VM l7 l00702l580FPl095+ 2.8070+

3.86l 0.38l l0.6lMSIlP4l l

l100 76l04/96l lM 105s-VM l0$n-vM l7 l00578l580rPlass+ 4.01 l 0.451 l0.2lSAIlP 4l l

l 104/961 1 H l05s-vM l05s-vM l7 l00578l580rPl09u+ 12.22 l 1.09l l0.31PPIIP 51 l

l l04/96l l M l05H-VM l055.VM l7 l00578l580FPl095+ 13.21 j 0.75]

l0.2lPPIlP 5l l

l102, 78]04/96l l N lO4H-VM l04H-VM l7 l00573l580FPl09H+ 13.43 l 0.96l l0.2lPPIlP.5l l

l l04/96l lM l045-VM l048-VM l7 l00573l580FPj095+ 17.10 l 1.24l l0.2lPPIlP5l l

l123' 79l04/96l l H 1045-VM l045-VM l7 l00914l580FPl09E+ 3.8670+

5.21) 0.59l l 76lMSIlP 4l l

j100 - 88l04/96l l H l04H-VM l04H-VM l7 l00511l580FPl098+ 11.55 l 1.57j l4.5lPPIjP 5l l

l 95 93]04/961 l N l08H VM l08E-VM l7 l00484l580FPl09H+ 2.45 l 0.46]

l0.2lSAIlP 4l l

l105 55l04/96l l N l04H-VM l045-VMl7 l00478l580FPl095+ 19.76 l 0.77l l0.8lPPIlP 5l l

l l04/96l lH l04H-VM l04H-VM l7 l00478l580FPl09E+ 20.37 l 1.15l l0,5lPPIlP 5l l

l104 1:4l04/96l lH l04H-vM l045-vM 17 l00412l580rPl09s. 12.60 l 0.64l 10.4lPPIIP 5l l

l l04/96l l H l04H-VM l04H-VM l7 l00412l580FPl09H+ 17.85 l 0.38l l0.3lPPIlP 5j l

l105.107l04/96l l H l04H-VM l04B-VM l7 l00396l580FPj09H+ 17.59T0+ 20.76l 0.73]

l0.1lPPIlP 5l l

l105 1D9l04/96l lH l04H-VM l04H-VM l7 l00390j580FPj09E+ 19.55 l 0.49) l0.6lPPIlP 5l l

l105.115l04/96l lH l04H.VM l04H-VM [7 l00352l580FPj09H+ 18.76 l 0.80l l0.5lPPIlP 5l l

l 98 ".40l04/96l lH l 04H-VM l08H-VM l7 jo0339l580FPl09H+ 11.85 l 0.57l j0.2lPPIlP 5l l

l100 140l04/96l l H l08H-VM l08H-VM l7 l00194l580FPl09H+ 12,93 l 0.61l l0.3lPPIlP 5l l

l_ _I I

l_l l

l_._

I l

l 1

l _._ l_ l_i_ I__ l NUMBI?. DF TUDES SELECTED FROM CURRENT OUTAGES 18 NUMBI?. DF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

24 NO 771.';*) ANALYSIS REQUESTED DATA II*ECTION CRITERIA:

Indicad on Location 09H p0.50 to IDH 0.50 (Not at Supports)

Perce= MAI.PPI,SAI.MSI REPCC DPTIONS:

Only examination results matching criteria are included ROCERIDGE TECHNOLOGIES

- - ~.

-. - ~ ~ ~ ~ - - - - - - - ~ ~. - - -. -. - -, -

_ ~ ~. ~

~ _ -

-~--n d

A 5

o CUMULATIVE REPORT

?

j 04/96, BCE. CLLVERT CLIFFS, UNIT 1

\\

STEAM CENERATOR

11 PAGE:

1 0F 3

}

OUTAGE DATA SET CURRENT DATE:

06/06/96 f

SELE;' TION VAR! ABLES: Indication Location. Percent TIME:

02:52:02 i

l l EXAv l

l EXAM EXTENT l l

l l

l

[

lRCW 1.!Nl DATI MEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS lMILjDEGl % lCt lCHNGl f

L

_I l__ t I

__ I I

i 1

L_l_ l_._L_l_l j 68 22l04/96 l H l04H-VM l04H.VM l9 l00464l580FPlDH+ 5.33 l 0.74l l0.3lPPIlP 5l l

l 63 23l04/96 lH l06H-VM l05H-VM l11 l00787l580FPlDH + 19.96T0+ 20.97l 0.30l l0,5lMSIlP 4l l

j l 58 34l04/96 l H l06H.VM l06H.VM l12 l00837l580FPlDH + 12.09T0+ 16.41l 0.57) l0.2lMSIlP 4l l

i j 64 40l04/96 l H l06H-VM l06H.VM l11 l00192l580FPlDH + 4.45 l 0.64l l0.2lSAIlP4l l

l 82 40l04/96 l H l04H-VM l04H.VM l7 l00283l580FPlVH + 7.37T0+ 11.99l 0.82l l0.6lMSIlP 4l l

i l105 41l04/96 lH l04H-VM l04H VM l7 l00593l580FPlVM + 3.33 l0.37l l0.4lSAIjP 4l l

l115 41]04/96 l H l04H-v5 l04H VH l7 l00593{580FPlDH + 10.67 l 0.46l ' l0.4lSAIlP 4l l.

I j

jl06 42l04/96 lH jo4H.VM l04H.VM l7 l00593l580FPlDd + 2.21 l 1.26l l0.4lSAIlP4l l

l l102 48l04/96 l H l04H-VM l04H.VM l7 l00612l580FPjvH + 4.26T0+

9.52l 0.48l l0.8 lMSIlP 4 l

{

j l112 50j04/96 lH l04H-VM l04H-VM l7 l00611l580FPlVE,+ 3.42 l 0.44l l0.4lSAIlP4l l

l l 55 51l04/96 l H l06H-VM l06H-VM l12 l00850l580FPlDH + 2.49 l 0.80l l0,4lPPIlP $l l

f I

l106 52l04/96 l H l05H-VM l05H.VM l7 l00687l580FPlDH + 15.98T0+ 17.45l 0.53l l0.2lMSIlP 4l-l l 96 58l04/96

'l H l06H-VM l06H-VM l7 l00658l$80FPlVH+ 8.51 l 0:46l l0.2lSAIlP 4l

'l l106 58l04/96 lH iTEC-TEHl09H-VH l7 l00667l580FPlDH + 16.20 l 0.20l l0.4]S91lP4l

'l l

l04/96 lH VH -VM '7H -VM l7 l00667l580FPlVH + 7.71 l 0.54j l0.5lSAIlP4l l

l l 81 59l04/96 lH 04H-VM l04H VM j7 l00307l580FPlVH + 13.60

) 0.65]

l0.3lSAIlP 4l l

?

l l 86 '60l04/96 lN 04H-VM l04H-VM l7 l00308l580FPlVH +

6.84T0+ 10.92l 0.35l l0.5lMSIlP 4l l

f l 91 61l04/96 lH 04H.VM l04H-VM [7 l00646l580FPlVH + 11.92 l0.38l l0.2lSAIlP 4l l

[

j l 40 62l04/96 lH 105H-VM l05H.VM l7 l00316l580FPlVE +

9.5370+ 14.04l 0.31l l0.3lMSIlP 4l l

f i

l 75 63l04/96 lH lC4H-VM l04H-VM l7 l00316l580FPjVH + 14.22 l 0.34l l0.8lPPIlP 5l l

f l 81 63l04/94 lM,04H-VM l04H-VM j7 l00319l580FPlVE + 10.37T0+ 12.02l 0.46l l0.3lMSIjP4l' l

l103 63l04/96 lH 104H-VM l04H-VM l7 l00647l580FPlDH + 12.56 l 0.89l l0.3lSAIlP4l l

l 86 64l04/96 j H ;05H.VM l05H-VM l7 l00316l580FPlVH +

5.49T0+ 16.33l 0.34l l0.3lMSIlP 4l l

1 l 86 66l04/96 lH iO4H-VM l04H-VM l7 l00323l580FPlVH +

3.7670+ 13.77) 0.27l l0.3 lMSIlP 4 l l

l l102 66l04/94 lH ~04H-VM l04H.VC l7 l00632l580FPlDH + 11.6070+ 14.39l 0.51]

l0.3lMSIlP 4l l

)

l 81 67l04/96 lH.04H-VM l04H VM l7 -l00325l580FPlVH+

8.88T0+ 12.17l 0.59) l0.3lMSIlP 4l l

l l103 67l04/96 lH :04H-VM l04H-VM j7 l00631l580FPlDH +

8.74T0+ 13.68l 0.51l l0.4lMSIlP 1]

l l

l 88 68l04/96 lH 04H-VH l04H-VM l7 l00327l580FPlVH + 2.82 j 0.44l l0.2lSAIlP 4l l

l 96 68l04/96 lH 04H-VM l04H-VM 17 l00627l580FPlVH +

5.6670+ 11.48] O.54l l0.3lMSIlP 4l l

l 81 69l04/96 lH : 04H-VM l04H.W l00332l580FPlVH +

7.6970+ 11.05l 0.33!

l0.3lMSIlP 4l l

l 87 69l04/96 l M 04H.VM l04H VM l7 l00333l$80FPjVH + 3.48 l 0.56l l0.4lSAIjP 4l l

l 86 70l04/96 lH.04H-VM l04H-VM [7 l00328l580FPjvH +

3.35T0+ 14.15l 0.32l l0.4lMSIlP 4l l

{

l102 70l04/96 lH iO4H.VM l04H-VM l7 l00626l580FPlDH + 13.41 l 0.50l l 0.2 lSAIlP 4 l -

l l

l112 72l04/96 lH '04H.VM l04H-VM l7 l00557l580FPlVH + 3.2470+

5.36l 0.23l l0.3lMSI]P 4l l

l 96 74l04/96 lN l04H.VM l04H-VM l7 l00580l580FPlVH +

9.86 l 0.59l l0.2lSAIlP 4l l

l 98 74j04/96 lH 104H-VM l04H VM l7 l00519l580FPjVu +

6.36T0+ 15.99l 0.97l l0.5lMSIlP 1l l

l 81 75l04/96 lH 104H VM l04H-VM l7 l00374l580FPlVH + 10.72 l 0.39l l0.5lSAIlP 4l l

l 87 75l04/96 lH,04H-VM l04H-VM j7 l00383l580FPlVH + 3.24 l0.61l l0.4lSAIjP 4j l

l103 75l04/96 lH 04H-VM l04H-VM l7 l00578l580FPjDH+ 9.86 l 0.62l l0.4lSAIlP 4l l

l100 76l04/96 jH 105H-VM l05H VM l7 l00578l580FPlDH +

8.13T0+

8.70l 0.37l l0.3lMSIlP 4l l

l104.76l04/96 lH 04H.VM l04H-VM l7 l00580l580FPlVE + 7.85 j 0.54l l0.2lSA!lP 4l l

l l103 17l04/96 lE '04H-VM l04H-VM l7 l00570l580FPlDH +

6.79T0+ 13.74l 0.65l l0.5lMSIlP 4j

'l l

l04/96 lH,04H.VM l04H-VM l7 [00570l580FPlVH +

2.17T0+ 10.78l 0.48l l0.3lMSIlP 4l l

j l 96 78l04/96 lH l04H-VM l04H VM l7 l00572l580FPlVH+ '2.48 l 0.49l l0.2lSAIlP 4l l

l102 78l04/96 lH l04H.VM l04H-VM l7 l00573l580FP]DH + 3.79 l 0.88l l0.5lPPIlP 5l l

i i_ _l 1_

l L _l I

I I

I_l l.__l l

l l

l l

ROCKRIDGE TECHNOLOGIES i

i l

1

m

~_

m

.__m

__4

?

CUMULATIVE REPORT

)

04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

2 OF 3

d OUTAGE DATA SET CURRENT DATE:

06/06/96

' SELECTION VARIABLES: Indication Location. Percent TIME:

02:52:02 i

l l

l EKAMl l

l EXAM EXTENT l l

l l

l l

lROWjLINl DATEl HEAT 8l LEG l PROGRAM) ACTUAL lEXP] CAL l PROBE l 14 CATION l VOLTS l MIL lDEGl % lCH lCHNGl l

I' l._- L I l

l_I l

L_I I

l l

l_ L_l_ L l l

l l

l04/96l l H l04H-vM l04H-vM l7 l00573l$80FPlDH + 4.75 l 0.45l l0.3lPPIlP 5l l

1106l 78l04/96l lH l045-vu l04H-vM l7 l00571l540FPjDH + 15.29 l 0.39l l0.2lsAIlP4l l

l108] 78104/n l l H lDH -vu lDH -vM 17 l00570l580FPIDH + 14.05To+ 18.07l 0.41l l0.5lMsIlP4l-l j

l 81] 79104/n l l H l04H-vM 104H-vM 17 100'3921580rPlv5 + 10.30 1 0.n j - 10.21sAIIP 4l l

l l nl 79l04/nl l H l04H-vM l04H-vu 17 l00571l580rPlvH + 3.08 l 0.s5l l0.31sAIIP 4l l

l 73l 81104/nl l H l04H-vM l04H-vM 19 100497l58erPlDH +

3.80 l 0.731 10.3tPPIlP 5l l

l103l n t04/96l l H l04H-vM l04H-vM 17 l00544l580FPIDE + 8.30To+ 12.30) 0.u l l0.2lMsIIP 4l l

l 87) 83!04/96l lH l04H-vM l04H-vu l7 l00392l580FPlvh + 9.90 l 0.40l l0.2lSAIlP 1l l

l103l 85!04/96l lH l04H-vM l045-vM l7 l00534l580FPlvH +

3.70T0+ 10.94l 0.54l l1.5lMSIlP 4l l

j.

l1051 87:04/96l l H l04H-vu l04H-vx tv-l005191580rPIDE.+ 7.21To+ 17.43l 0.46l l0.4lMSIlP 4l l

l123l 87iO4/96l l H l058-vx l058-vM J7 l00918l580FPlDH + 19.19 l 0.56l l105lPPIlP Sl l

?

I nl 88,04/96l l H l04H-vu l04H-vM 17 l00511l540FPlvH +

8.94 l 0.71l l0.3l8AIlP 4l l

l 83l 89:04/96l l H l04H-vM l045-vu 17 jo0398l580FPlvH + 7.69 l O'.49]

l0.2lsAIlP 4l l

4 j

l103l 89 04/96l l H l04H-vu 104H-vM #7 400505l580rPIDH + 7.76To+ 14.05l 0.41l 10.5lMSIIP 4l l

l108l 90 04/nl lH l048-vu l04H-vM n l00505ls00rPlDH +

9.50TO+ 10.58l 0.37l l0.2lMSIlP 4l l

l l

04/96l lH l04H-vM l04H vM !7 j00505l580FPlvH +

5.75T0+

6.04) 0.38l l0.2lMSIlP4l l

j l 83) 91'04/96l l H l04H-vM lDH -vM ;7 [00456l580FPlvH +

3.78 l 0,74l l0.3lMAIlP4l l

l 871 91 04/96l lH l04H.vu l04H-vu !7 t00406l580rPlvH +

9.58To. 10.0tl 0.47]

l0.3lMSIIP el l

l 91l 91 04/96l l H 107H-vu l07H-vu 17 l00502l580FPlVH +

2.6070+ n.00l 0.50l l0.6lMSIlP 4j l

-l 66l 92.04/96l lH l0sH-vu l055-DH tu 1008481580rPIDH -

5.51 1 0.64l 10.2lsAIIP 4l l

} nl 93 04/nl lH l048 vu l04H-vx :7 1004931580rPjvH + 2.91 1 0.44l 10.5lsAIIP 4l l

i l 80l100 04/96l lH l04H-vu l03H-vM 7 100414l580FPlDH +

3.54 l 1.03l l0.3lPPIl 2l l

j 82l100'04/96l lH l 04H-W l 03H-vx 7 !00413l580rP[DH +

2.55 l 1.01l l0.5lPPIlP 5l l

j l 92l100 04/nl lH l045-vu 104H-vu o 600429l580rPlvH + 12.n T0+ n.19l 0.n l l0.2lMSIlP 4l l

l 94l100:04/nl lH 104H-vu l04H-VM 47 l004291500FPlDH +

2.40

0.56l l0.3lSAIlP 4l l

l nl100 04/nl l H 104H-vu lcsH-vu a IO04301580FPivH + 6.03 l 0.51l 10.3lsAIIP 4l l

}

l106l100.04/96l lH l042-vu l04H-vM i7 l00429l500FPjVH +

5.79T0+

8.80l 0.39l l0.4lMSIjP4l l

l 91l101'04/96l lH l04H-vu lDH -vM.7

00727l580FP]vH +

1.73T0+

3,05l 0.44l l0.3lMSIlP 4l l

j l100l104;04/96l lH l04H-vM l04H.vM '?

!00727l580FPjDH + 3.19 l 0.75l l0.5lPPIlP 5l l

l l

04/96l lN {04H-vu 1045-vu [7 100727l580FPlDH +

7.0770+ 11.84) 0.35l l0.2lMSIlP 4l l

l l

. 04/n l lH l04H-vu l048-vM j7 ;007271580rPlvH + 2.257o. n.701 0.291 l0.5lMsIlP 4l l

l128l104:04/96)-

lH l04H-Vu l048-vu i7 ;00879l580FPlDH + 13.8270+ 20.29l 0.35l j0.2]MSIlP 4l l

l105l107104/961 lH l04H-vu l045-vM l7 l00396l580FPjDE + 2.13 l 1,08l l0.3lPPIlP 5l l

l 64ln0 04/96l lH l06H-vu l06H-vx :n l008091580rPIDE +

3.26 1 0.66]

l0,5lPPIl 2l l

l 68ln0 04/ nl lH l04H-vu l04H-vu it !005591580rPIDH + 4.22 1 0.52l l0.5lPPIlP 5l l

In6ln0:04/nl lB l04H-vu l04H-vu 67 100752l580rPIDH + 22.63 l 0.41l 10.2lSAIIP 4l l

j luS11n 04/96l lH l04H-vM l045-vu,7

007521580rPlvH + 22.50 l 0.441 l0.2lSAIjP 4l l

i l 86l112;04/96l lH l04H-vu l045-Vx !? 100226l580FPjvH +

2.51 l 0.78l l0.3lSAIlP 4]

l l 90l112'04/96]

lH l04H-vu l04H-vu 17 l003691580FPlvH + 16.17 l 0.51l l0.2lSAIjP 1l l

1 841114*04/961 lN l04H-vM l04H-vu 17 Ic0227l580FPlvH + 14.7270+ 18.43l 0.45l l1.1lMSIlP4l l

l 92l114'04/96l lH l04H-vM l04H-vM 17 [00363l580FPlDH +

5.13 l 0.69l l1.2lPPIlP 5]

l l

l l

604/96l lH l045-vM l04H-vu 9 l00363l580FPlvH + 16.03 l 0.43l l0.2lMAIlP4l l

l 94l114.04/96l

}H l075-vM l07H-vM 17 l00361l580FPjDH + 10.75 l0.47l l0.6lSAIlP 4l l

l 1

- 04/nl lH l07H-vM 107H-vu 17 1003611580FPjv5 +

2.9670+ 14.59l 0.32l l0.9lMSIlP 4l l

1. 9l115.04/96l l e 106e-06Hl06C-06Hl2 100158l580PHlvM -

2.95 l 0.97l l 7718AIlP 41 l

l - _ I _ __-_ l l_l 1

LJ l

l l

l_i_ L L._l_l ROCKRIDGE TECHNOLOGIES

l 1

CUMULATIVE REPORT -

00/96 BCE, CALVERT CLIFFS, UNIT 1 l

STEAM GENERATOR 11 PAGEt 3 OF 3

i OUTAGE DATA SET

CURRENT DATE:

06/06/96 i

SELECTION VARIABLES: Indication Location. Percent TIMES 02:52:02 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l lRCWlLINl DATEl HEAT 8l LEG l PROGRAM] ACTUAL lEXPl CAL l PROBE l 14 CATION l VOLTS l MIL lDEGl % lCH lCIDiGl l_ L_.I I

l_I I

l

__I l

l I

1._., l _ L__ l.__. I i

l 901116l04/96l l H l05H VM l05H-VM l7 l00351l580FPlDH + 5.89 l 0.64l l1.8lPPIlP 5l l

l105l117l04/96l lE l05H-VM l0$N-VM l7 l00714l580FPlDH + 15.05 l 0.46l l0.2lSAIlP 1l l-f l

j l04/96l lB l05H-VM l05H-VM l7 l00714l580FPjv5 +.3.15 l 0.29l j0.3lSAIlP 4l l

l107l121l04/96l lH l04H-VM l05H.VM l7 l06256l580FPlVU + 6.99 l 0.77l l0.2lPPIlP 5l l

l110l122l04/96l lN l04H-VM l04H-VM l7 l00254l580FPl$H + 13.31 l 0.50]

l0.3l8AIlP 4l l

l 85l123l04/96l lH l08H-VM l08H.VM l7 l00219l500FPlVH + 12.59 l 0.40l l0.2lSAIlP 4l l

.l 99l125l04/96l lH l04H VM l04H-VM l7 l00251l580FPlVM + 2.43 1 0.46l l0.1l8AIjP 4l l

l101:125l04/96l lH l04H-VM l04H-VM l7 l00250l580FPlVH + 5.42 l 0.53l l0.2lSAIjP 4l l

l 85;121lD4/96l lB l088.VM l08H VM l7 l00216l580FPlDH + 4.74 l 0.79l l0.3lPPIl 2l l

l l

l04/96l lH l08H-VM l08H-VM l7 l00216l580FPlVH,+

3.3070+

4.21] 0.80l l0.2lM81lP 1l l

l103!127l04/96]

lH l04H-VM l04H-VM l7 l00246l580FPlDH + 12.95 l0.50l l0.3]sAIjP.1l l

]105 127lO4/96l lM l04H-VM l04H-VM l7 l00715l580FPlDH + 11.03T0+ 13.59l 0.44l' l0.3lMSIlP 4l l

l113 127 l 04 / 96 l lH l04H-VM l04H-VM l7 l00243l580FPlDH +

3.0970+

4.80] 0.50l l0.9lMSIlP 4l l

l 90 128l04/96i lH l04H VM l04H-VM l7 l00239l580FPjDR + 5.11 l 0.80l l0.2lPPIlP 5l l

l l04/96 lH l08H-09Hl0BH.VH l7 l00182l590FPlDH+

5.51 l 0.*19l l.3lPPIlP 5l l

l 95 129l04/96i lH l04H-VM l04H-VM l7 l00238l580FPlDH + 4.00 l 1.49l l0.4lPPIlP Sj l

l113 129l04/96 4 lH l04H-VM l04H-VM l7 l00241l580FPlDH + 10.67 l 0.30l l2.0lMSIjP 4l l

l 99 131l04/96i lH l08H.VM l08H-VM l7 l00211l580FPlVH + 11.12 l 0.46l l0.2lSAIlP 4j

{

l102 134l04/56, lH l08H-VM l08H-VM l7 l00202l580FPlDH +

3.79 l 0.09l l0.2lPPIlP 5l l

l 42 138l04/96!

lH l0BH-VM l08H-VM l7 l00196l580FPlVH + 3.0170+17.30l0.45l l0.2lMSIlP 4l l

l 83 145l04/96I lH l04H VM l08H.VM l7 lOO318l580FPlDH +

3.68 l 0.77l l0.9lPP1lP Sj j

j 73 153l04/96i lH l05H-VM l05H-VM l9 l00597l580FPlVE +

3.16 l 0.81l l0.4lPPIlP 5l l

1.__ __._ l l_1 i

L._. I I

I I

l _ i ___ l _ i _ l _1 NUM3IR OF TU5ES SELECTED FROM CURRENT OUTAGE:

101 NL73IR OF DATA RECGRDS SELECTED FROM CURRENT OUTAGE:, 112 NO ~'.END ANA* YSIS REQUgJTED b

DATA SELECTICS CRITERIA; Intration Lc :a t ion : DH p2.00 to DC p2.00 (Not at Support s)

Per:ent: MAI 771.SAI.MSI REFIKT OPTIONS:

Only examinatan results matching criteria are included ROCKRIDGE TECHNOLOGIES

i CUMULitTIVE REPORT l

04/96, BCE, CATNERT CLIFFS, UNIT 1 l

STLAM GENERATOR

11 PAGE:

1 OF 1

TTAGE DATA SET

CURRENT DATE:

06/06/96 i

. LECTION VARIABLES: Indication Location, Percent TIME:

02:55:48 i

i J

      • NO CALL 5 IN THIS RANGE ***

DATA SELECTION CRITERIA:

Indication Location: 09C p0.50 to 10C 0.50 (Not at Supports) i Parcent: MAI,PPI,SAI,MSI f

REPORT OPTIONS:

i Only examination results matching criteria are included l

l 1

l l

l l

l ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

1 OF 1

'UTAGE DATA SET CURRENT

]

DATE:

06/C6/96 JLECTION VARIABLES: Indication Location, Percent TIME:

02:57:58

      • NO CALLS IN THIS RANGE ***

DATA SELECTION CRITERIA:

)

Indication Location: 01C 1.00 to 08C. 1.00 (Not at Supports)

Parcent: MAI,PPI,SAI,MSI REPORT OPTIONS:

s only examination results matching criteria are included I

1 l

l s

1 I

ROCKRIDGE TECHNOLOGIES

=~ ~

COMULATItfE REPC3T 04/96, BGE, CALt'ERT CLIFFS, UNIT 1 STEAM CENERATOR

11 PAGE:

1 OF 3

OUTAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent, Probe TIME:

03:35:29 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE lIDCATION l VOLTS l MIL lDEGl % lCH lCHNGl L-_l _ I I

L._ l l

l_l l

l

--l

. L _ l _._ L._ l _ L_ - l l 27l 7l04/96l l C.lTEC+TEHlTEC-TEHj l00001l580ULlTSH+ 3.30 l 0.47l l143l 33l 1l l

l 68l 16l04/96l l C lTEC-TEHlTEC-TEHl l00024l580ULl03C+ 0.27 l 0.33l l 0l 12lP 4l l

l 80l 18l04/96l l C lTEC-TEHlTEC-TEHj jo0024l500ULl07H-0.74 l 0.49l l 0l 16lP 4l l

l 101 26l04/96l l C ln C-n slTEC-TEnl l00b11lsson lvu - 0.03 l 1.74l l 1sl 77lP 1l l

l tal 2sl04/96l l C lTEC-TEHITEe-TEHl l00103l5e00L104H+ 0.s2 l 0.621 l 0l 1 lP 4l l

l 86l 26l04/96l l C lTEC-TEHlTEC-TFHl l00024l58bULl07H-0.68 l 0.42l l 0l 14lP 4l l

1 731 28104/96l l C lTEC-TEHITEC-TEHl l00024l580utlDC - 1.79 l 0.55l l 0l 18lP 4l l

l 60l 34104/96l l C lTEC-TEHlTEC-TEHl

.l00019l5800Ll05H.

0.93 l 0.33l l Dj 16lP 4]

l l 51l 37!04/96l l C lTEC-TEHlTEC-TEHl l00019l580ULl07H- 0.06 l 0.29l l Dj 14lP 4l l

l 58l 36;04/96l l C lTEC-TEHlTEC-TEHj l00019l5000Ll015-0.93 l 0.46l l 0l 20lP 4l l

l 3sl 5:104/961 l C lTEC-TEHITEC-TEHl l00044l580Unl03H- 0.e8 l 0.251 l 01 10lP 4 l l

4 l 81l $*!04/96l l C lTEC TEHlTEC-TEHl l00118l580ULjVH + 1.23 l 0.54l l 0} 18lP 4l l

1 41l s3 04/96l l C ITEC-u nlTEC TEHj l00109lssoniTss+ 0.s6 1 0.44l l122l s2l 11 l

i 46l 54 04/96l l C lTEC-TEHlTEC-TEHl l00112l580ULj7SH+

1.16 l 0.91l l* !1l 25l 1l l

50l 54 04/96l l C lTEC-TEHjTEC-TEHl l00112l580ULlTSH+ 1.17 l 2.06l l150l 26) 1l l

J 1

47l 55 04/96l l C lTEC-TEHlTEC-TEHl l00109l580ULlTSH+

1.97 l 0.83l l137l 39l 1l l

i 53l 55 04/96l l C lTEC-TEHlTEC-TEHj l00112l580ULlTSM.

0.85 l 2.93l l"E7l 18l lj l

46l Si 04/96l l C lTEC TEHlTEC TEHl l00114l590ULlTSH+

1.04 l 0,50l lU Bl 38l 1l l

l 04/96l lC lTEC-TEHlTEC-TEHl l00114l580ULlTSH+ 1.71 l 0.66) l158[ 16] Il l

j 48l 51 04/96l l C lTEC-TEHlTEC-TEH]

l00113l580ULlTSH+ 1.55 l 0.70l l144) 32l 1l l

{

! 57l 57 04/96l l C lTEC-TEHlTEC-TEHj l00113l580ULlTSH+

0.81 l 2.79) l150) 26l 1l l

j 64l 56 04/96l l C lTEC-TEHlTEC TEHj l00113l580ULl02H.

0.93 l 0.52l l 0 l 18 l P 4 l l

l 11l EP 04/96l l C lTEC-TEHlTEC-TFHl l00046l580ULlTSC. 1.26 l 0.56l l.53l 26l 11 l

55] 5) 04/96l l C lTEC-TEHlTEC-TEHl l00113l580ULlTSH.

0.95 l 1.54l l*.56l 19l 1l l

{

581 e4 04/96l l C lTEC-TEHITEC-TEHI l00117l580unl02H+

3. e 0 l 0.44l l al 17lP el l

27l 65 04/96l l C lTEC-TEHlTEC-TEHj l00048l580ULlTSC. 1.26 l 0.63l l128] 13lP 1l l

i 57) (E 04/96l l C lTEC-TEHlTEC-TEHl l00117l580ULl02H+ 0.66 l 0.32l l D l 12 l P 4 l l

12el 7- 04/96l l C lTEC-TEHITEC-TEHI l00095l580ULl07H.

1.02 l 0.33l l 3 l 13 l P 4 l l

I 138l 7: 04/96l l C lTEC-TEHlTEC-TEHj l00096l580UL101H+ 0.93 l 0.56l l 0l 24lP 4l l

' 87l U 04/96l l C lTEC-TEHlTEC-TEHl l00121l5800Ll06C- 0.52 l 0.29l l D l 12 l P 4 l l

1104l 74 04/96l l C lTEC-TEHlTEC-TE.Hj l00039l580ULl09H. 0.39 l 0.96l l Dj 30lP 4l l

l137l 7' 04/96l l C lTEC-TEHlTEC-TEHl l00093l580ULl030-0.95 l 0.82l l 0l 26lP 4l l

1140l 75 04/96l l C lTEC-TEHlTEC-TEHj l00100l$80ULl05C+ 0.93 l 0.41l l 0l 17lP 4l j

106l 6
04/96l l C lTEC-TEHITEC-TEHl l00039l580ULl09H+

0.G3 l 1.10l l118l 34lP 1l l

l140j 81 04/96l l C lTEC-TEHlTEC-TEHl l00094l580ULl05C+

0.96 l 0.88l l 0l 29lP 4l l

l 70l 82 04/96l l C lTEC-TEHlTEC-TEHj l00126l580ULlTSH+

1.99 l 0.49l l134 l 22lP 1l l

i i 751 s) 04/961 l C lTEC-TEHlTEC-TEHj 100123l580utlTsH. 1.23 l 0.97l l146l 30l 1l l

(

l 78] 64 04/96l l C lTEC-TEHlTEC-TEHl l00123l580ULlTSH+

0.68 l 1.02l l139l 37l Il l

i138) 84 04/96l lC lTEC-TEHjTEC TEHl l00091l580ULl02C-0.C6 l 0.65l l 3 l 01l P 4 l l

! vil as 04/96l lC lTEC-nHITECenHI l0012slssonlTss. 0.9s l 0.941 (106l 64l 1l l

l l 60l Bf 04/96l l C lTEC.TEHlTEC-TEHl l00128l580ULlTSH.

1.20 l 1.36l l155] 20l' 1l l

l jl381 96 04/96l lC lTEC-TEHlTEC-TEHl l00087j580ULl02C, 0.90 l 0.44l l Dl 16lP 4l l

71l e7 04/96l l C lTEC-TEHjTEC-TEsl l0012sjsBOULITsa+ 0.87 l 0.52l l103l 66l 1) l l

j l

04/96l lC lTEC-TEHlTEC-TEHl l00128l580ULlTSB+

1.44 l 0.34l l116l s7l 1l l

I nl e 04/961 l C lTEC-TEHITEC-TEHI l000771580utlTSH+ 2.o5 l 1.54l l152l 25l 1l l

L _ l-_._

l l_1 i

L-._ I I

l l

L-_ l _ l-.__ l _ L._.I ROCERIDGE TECHNOLOGIES i

l

CUMULATIVE REPORT 04/96, PGE, CPLVERT CLIFFS. UNIT 1 STEAM CENERATOR 11 PACE:

2 OF 3

OUTAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent, Probe TIME:

03:35:29

)

{

}

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLIN] LATE l HEAT 8lLE0l PROGRAM l ACTUAL lEXPl CAL jPROBEl LOCATION

} VOLTS l MIL lDEGl % lCH lCHNGl l

l_ _.I i

1_ l I

L_. I l

I I

L._.L L L__t

_I l117l 87l04/96l l C lTEC-TEHjTEC-TEHl l00088l5800LlVC +

1.45 l 0.54l l 0l 20lP 4l l

l 57l 89l04/96l l C lTEC-TEHlTEC-TEHl l00129l580ULlTSH+

0.63 l 0.64l l158l 16l 1l l

l 76l 90]D4/961 l C lTEC-TEHlTEC-TEHl l0007.7j500ULlTSH+ 2.33 l 1.93l l146l 30j lj l

l 78l 90l04/96l l C lTEC-tEHlTEC-TEHl l00678l580ULjTSH+

1,77 l 0.83l l145l 31l 1]

l l140l 90l04/96l l C lTEC-TEHjTEC-TEHj l00088l580ULl01H-0.82 l 1.19l l 0! 33lP 4{

l l 71l 91l04/96l l C lTEC-TEHlTEC-TEHl l00072j580ULlTSHe 0.63 l 2.73l l 68l 82lP 1]

l l138l 92j04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl01C+

0.69 l 0.81l l 0l 25lP 4l l

l 67l 93l04/96!

l C lTEC-TEHjTEC-TEHj l00072l580ULlTSH+

0.86 l 1.25l l153l 22l 1l l

l105l 93l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl01C-0.24 l 0.71l

[ 0l 24lP 4[

l l139l 93l04/96i lC lTEC-TEHlTEC-TEHl l00089l5800Ll014-0.91 l 0.59l l 0l 20lP 4l l

l 69) 97l04/96l l C jTEC-TEHlTEC-TEHj l00071l580VLlTSH+

1.02 l 0.70l l123l 28lP 1l l

l l 80) 98l04/96!

l C lTEC-TEHlTEC-TEHl l00078l580ULl08H-0.24

{ 0.24l l 0l 11lP 4l l

l132l 98l04/96+

l C lTEC-TEH]TEC-TEHl

{00089l580ULl05C+

0.89 l 0.45l l 0 l 16 l P 4 l l

l l136] 98l04/96 l C lTEC-TEHlTEC-TEHj l00089l580ULj01H-0.89 l 0.55l l 0l 19lP 4l l

I l 35l 99l04/96 l C lTEC-TEHjTEC-TEHj l00069l580ULl04H+

0.98 l 0.49l l 0{ 26lP 4l l

l 6S} -99]O4/96 lC lTEC-TEHlTEC-TEHl l00011l5800LlTSH+

0.93 l 1.59l

{161l 13l 1l l

l137l101l04/96 j C lTEC TEHlTEC-TEHl l00092j580ULl09C+

0.77 l 0.39l l 0l 17lP 4[

]

} 4 91109l04/96 lC lTEC TEHlTEC-TEHl l00069l580ULlTSH+

1.46 l 0.73l l166l<101 1{

j l 531109l04/96' lC lTEC-TEHlTEC-TEHl l00069l580VLlTSH+

0.99 l 0.43l l130j 19lP 1l l

l 11l111l04/96.

l C lTEC-TEHlTEC-TEHl l00065l580ULl04H+

0.80 l 0.73l l 0l 28lP 4 {

l l 54l112l04/96' lC lTEC-TEHlTEC-TEHl l00069l580ULlTSH+

1.22 l 0.42l l126l 25lP 1l l

l125l113]04/96 lC JTEC-TEHlTEC-TEHl l00092l5000LjTSH+

0.71 l 0.95l l154l 21l 1l l

l 52l114l04/96 lC lTEC-TEHlTEC-TEHl l00068l580ULlTSH+

0.8B l 1.07l l146{ 30l 1l l

l128l114l04/96 lC lTEC-TEHlTEC-TEHj l00091l580ULjTSH+

0.63 l 1.55l l13Bl 38l 1l l

l 9l115l04/96 lC lTEC-TEHlTEC-TEHl l00066l580ULlVM - 2.95 l 0.66l l134{ 42l 1l l

l47l115l04/96 l C lTEC TEHlTEC-TEHj l00068l5800LlTSH+

1.11 l 0.75l

{153l 22l 1l l

l 42l118l04/96 l C lTEC-TEHlTEC-TEHl l00069l580ULlTSH.

1.90 l 0.68l l159l 15l 1{

l l 3l123l04/96 lH lTEH 06ClTEH-05Hl l00022l580ULlTSH+

0.52 l 0.97l l 67l 29lP 2l l

l l

l04/96 lC lTEC-06ClTEC-06Cl l00101l580ULlTSC+

0.90 l 0,70l l129l 33lP 1l l

l l122i124l04/96 lC lTEC TEHlTEC-TEHj l00081l580ULl10H+

0.52 l 0.63l l 0l 21lP 4 l l

l l

l04/96 l C lTEC.TEHlTEC-TEHl l00081l580ULl02C+

0.78 l 0.51l l 0 l 18 l P 4 l l

l 95l125l04/96 lC lTEC-TEHlTEC-TEHj l00099l580ULl05H-0.15 l

.65l l 0l 27[P 4l l

l 91l129l04/96 l C lTEC-TEHlTEC-TEHl l00074l580ULjoEH+

0.73 i

$9l l 0l 17lP 4l l

l E8}130l04/96' l C lTt:C-TEHlTEC-TEHj l00072l580ULlDH -

2.27 l 0.60l l 0 l 18 l P 4 l l

l 91l131l04/96;

) C lTEC-TEHlTEC-TEHl l00074l500ULl080+

0.65 l 0.27]

l Oj 13lP el l

l 63l143l04/96' l C lTEC-TEHlTEC-TEHl l00058l580ULlVM 1.83 l 0.29l l 0l 17lP 4 l l

l 92l144l04/966 lC lTEC-TEHlTEC-TEHl l 00074 l 5800Ll 02 H+

1.09 l 1.01l 0l 31lP 4 l l

l 63l157l04/96 l C lTEC-TEHlTEC-TEHl l00056l580ULl02C-0.93 l 0.69l l 0l 30lP 4l l

l 53l161l04/96 l C lTEC-TEHlTEC-TEHl l00056l580ULl05C.

0.03 l 0.33l l 0 l 14 l P 4 l l

l l

l04/96?

l C lTEC-TEHlTEC-TEHj l00056l580ULl02C+

0.06 l 0.51l l 0l 20lP 4l l

l 36l164l04/96' lC lTEC-TEHlTEC TEHl l00056l580VLlTSH+ 12.57 l 0.39l l 89j 75l 1}

l L_ I _1 1_l I

l __l._. _l i

I l _ I___ L _ i_ _!_ I ROCKRIDGE TECHNOLOGIES

CDMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1

{

i l

STEAM GENERATOR 4 11 PAGE:

3 OF 3

OUTAGE DATA SET t CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent, Probe TIME:

03:35:29

' NW2ER OF TUDES SELECTED FROM CURRENT OUTAGE:

81

{

NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

86 NO TREND ANALYSIS REQUESTED I

DATA SELECIION CRITERIA:

1 Percents 0 to 100%

Probe: 01 BOBBIN S

REPORT OPTIONS:

Only examination results matching criteria are included e

i l

1 i

I l

l l

I l

l l

i I

l 1

1 I

l l

i l

l l

1 ROCKRIDGE TECHNOLOGIES d'

1

(

/

CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFPS, (MIT 1 STEAM GENERATOR 11 PAGE:

1 OF 22 OUTA3E DATA SET CURRENT DATE:

06/06/96 SELE.710N VARI ABLES: Percent TIME:

03:40:45 l

j EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW LINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE] LOCATION l VOLTS l MIL lDE0l t lCH lCHNGl L._ - _ l -

l_

l

_I I

l_l 1

1 I

L_ L_ i _ l _ l.a___ l l 15 5l04/96l l C lTEC-TEHlTEC-TEHl l00103l580ULl06H+ 8.81 l11.40l l174lDNTjP 1l l

l 69 13l04/96l l C lTEC-TEHlTEC-TEHl l00024l580VLlVM + 24.96 l 9.25l l179lDNTlP 1]

l l 40 14l04/96l l C lTEC-TEHlTEC-TEHj l00014j580ULlVM+ 1.72 l 8.24j l174lDNTlP 1l l

l 2 fr 15l04/96l l C lTEC-TEHlTEC-TEHj l00'103l580ULlV)1 - 1.26 l12.56) l172lDNTlP1l l

l 49 15l04/96l l C [TEC-TEHlTEC-TEHl l00014l580ULlTSH+17.16 l4D.65l l174]DNTlP1l l

l 72 18l04/96]

l C lTEC-TEHlTEC-TEHl l00024 l58hULlTSH+ 22.40 l 5.06l l174lDNTlP1l l

l 17 19l04/96l l C lTEC-TEHlTEC-TEHl l00103l580ULj06H+ 9.43 l 6.67!

l172lDNTlP 1l l

l 3; 19l04/96l l C lTEC-TEHlTEC-TEHl l00015l580ULlVM

  • 1.84 l10.29) li79lDNTlP 1l l

l 69 19lO4/96l l C lTEC-TEHlTEC-TEHl l00024l500ULlDH + 6.91 l 6.71!

l178lDNTIP 1l l

l 7: 20l04/96l l C lTEC-TEHjTEC-TEHl lJ0025l580ULl08C+

6.39 l 7.99!

l1*19lDNTlP 1l l

l if 22l04/96]

l C lTEC-TEHlTEC-TEHj l00003l580ULl05H+ 19.85 l 5.13!

l1'i8lDNTlP 1l l

l 59 23l04/96l l C lTEC-TEHlTEC-TEHl l00017l580ULlDH + 23.38 l 7.111 l179lDNTlP 1l l

l 6-23l04/96l lC lTEC-TEHlTEC-TEHj l00025l580ULlVM + 24.15 l 7.92 l178lDNTIP 1l l

l 9; 23j04/96l l C lTEC TEHlTEC-TEHI l00029l580ULl09C+

1.57 l'.4.85 l"~8lDNTIP 1l l

l li 24l04/96l l C lTEC-TEHlTEC-TEHl l00011l580ULl04H+ 36.52

{ i.91 li'7lDNTiP 1l l

l Si 24l04/96!

l C lTEC-TEHlTEC-TEHl l00028l580ULl03C-1.16 l 5.94' l1'4 lDNTIP 1]

l l 3; 25 j '54 / 96 l lC lTEC-TEHjTEC-TEHj l00017l580ULlVM -

1.90 l f.27 l1 9lDNTlP ll l

l 5-25l04/96i l C lTEC-TEHjTEC-TEHl l00016l580ULlDH + 19.98

(;.48 l-9lDNT!P 1l l

l 6s 25l04,96l l C lTEC-TEH]TEC-TEHj 100024l580ULlvM + 25.40 1;..s8-l1 2lDNTIP 1l l

l li 26l04/96l lC lTEC-TEHlTEC-TEHj l00010l580ULl05C+ 7.42 l13.A7:

l1"8lDNT!P1l l

l 72 26l0</96l l C lTEC-TEHlTEC-TEHI lc0025l580aLl05C+ 19.93 l25.17 lD9lbHTi?1l l

l 33 27l04/96l' l C lTEC-TEHlTEC-TEH}

l00103]580ULlDC 1.35 l E.83 l3n6lDNT!P lj l

l 6i 27lu4/961 l C lTEC-TEHlTEC-TEHl l00024l580ULlVM + 24,74 l P.39 l1"9lDNTfP 1l l

l4+

29l04/96I l C lTEC-TEHITEC-TEHI l0001r,l580uLl01C+ 25.05 le. 21 l: 4lDNT:P 1l l

l 63 29l04/96!

lC lTEC-TEHlTEC-TEHl l00024l580ULlDH + 6.60 l11.504 l1'3lDNTIP 1l l

l 9-29]04/96l lC lTEC-TEHITEC-TEHI l00028l580ULl09H- 0.35

! s.71 l1 6lDNTlP 1l l

l 9i 29l04/96i l C JTEC-TEHlTEC-TEHj l00029l5800Ll0iHe 0.00 l

.12-l163lDNT!P 1l l

l 2: 30l04/96i lC lTEC-TEHlTEC-TEHI l c0011l s 8 0ULl oSH+ 15. 96 i 5.97-l: slDNT:P 11 l

l zi 30l04/96!

l C JTEC-TEHlTEC-TEH}

l00011l580ULlVM +

1.86 l i.03.

l1~4lDNijP 1l l

l 42 30l04/96!

l C lTEC-TEHlTEC-TEH) l 0 0016 l580ULlTSC. 32. 06 l . 3 5 l1'5lDNT'P 1l l

l 7: 30l04/96l l C lTEC-TEHlTEC-TEHI lc 0025l580Unl 07C+ 23.37 l13.00:

l1 9lDNT'P 1l l

l l04/961 l C lTEC-TEHjTEC-TEHl l 0 0025 l 580UL l 07C+ 23.12

] *. 3. 0 0 '

l1 9lDNTJP 1l l

l 86 30j04/96l lC lTEC-TEHlTEC-TEHl l00025j5800Ll03H+

0.67 l 5.514 l160lDNT]P 1l l

l 9i 30l04/96l lC lTEC-TEHlTEC-TEHl l00029l5800Ll09H+

0,24 l13.15j l161lDNTlP 1l l

l 95 30l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+

0.06 l13.41l l175lDNT]P 1l l

l 15 31104/961 l C lTEC-TEHlTEC-TEHl l00011l580ULl06C+

9.04 l 7,071 l161[DNTIP 1l l

l 43 31l04/96l l C lTEC-TEHlTEC-TEHl jo0019l580ULlTSH+ 18.11 l i.391 l1EllDNTIP 1l l

l 9'

31l04/96i l C lTEC TEHjTEC-TEHl l00029l580ULl09H+

0.00 l 5.141 l1'6lDNTIP 1l l

l (f 32l04/961 lC lTEC-TEHlTEC-TEHl l00019l580ULlVM + 2.20

[ 3.20i l150]DNTlP 1l l

l 96 32l04/96i l C lTEC-TEHlTEC-TEHj l00029l580ULl09H+ 0.36 l10.71!

l151 lDffTl D 1l l

l 3 *. 33l04/961 lC lTEC-TEHlTEC-TEHl l00019l580ULlVM - 2.02 l1;.471 l163]DiTT!P 1l l

l 47 33l04/96!

lC lTEC-TEHlTEC-TEHl l00019l580ULl02C+ 36.10 1;".401 l177lDNTlP 1l l

l 69 33l04/961 l C lTEC-TEHlTEC-TEHl l00025l580ULlVM + 24.82 l 7.771 l179lDNTjP 1l l

l 97 33l04/96l lC lTEC-TEHlTEC-TEHl l00028l580Ull07H+ 2.92 l 6.66l l173lDNT]P 1l l

l l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULj07H+

3.84 l16.521 l1~15lDNTlP 1l l

l __._ _ l Ll I

l_l l

l

_t

' ___ l _ l ___ L _ I_ l ROCKRIDGE TECHNOLOGIES

x

---.=

c

. ~.. -.

5 I

r CTMJLATIVE REPORT j

00/06, BGE, CALVERT CLIFFS, UNIT 1 I

f STEAM GENERATOR

11 PAGE:

2 OF 22 OUTAGE DATA SET s CURRENT DATE:

06/06/96 SELECTION VARIABLES Percent TIME 03:40:45 l

l l EXAM l l

l EXAM EXTENT {

l l

l l

l lkOWlLINl DATEl HEAT #l LEG lPROGRAMj ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDECl t lCH lCHNGl e

L._ L I I

L_I l

l_I I

I I

L_ l_ L l _l_l l

l l04/96l l C lTEC-TEHjTEC-TEHl l 0002 6 l 55 0ULl 08H+

8,61 l 5.24l l175lDNTlP 1l l

f l

l l04/96l l C lTEC-TEHlTEC TEHj l00028l560ULl08H+ 11.64 l 6.54]

l175lDNTlP1l l

i l

l l04/96l l C lTEC-TEHjTEC-TEHl l00028l543ULl09H+

0.44 l 6.25l l179lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00028l587ULl0,7C+ 12.56 l13,90l l173lDNTlP 1l l

l l

l04/96l l C lTEC-TEHjTEC-TEHl l00028l583ULl07C+

9.87 l 8.83l l175lDNTlP 1l l

l 54] 34l04/96l l C lTEC-TEHlTEC-TEHl l00019l563ULj05C+ 23.06 l14.06l l180lDNTlP 1l l

l 27l 35l04/96l l C lTEC-TEHlTEC-TEHl l00:06l5BOULl03C+ u.80 l49,54l l179lDNTlP 1]

l l 69l 35l04/96l lC lTEC-TEHlTEC-TEHl l0CO24l543ULlVM + 25.75 l11.20l

.l173lDNTlP 1l l

!101l 35l04/96l l C lTEC-TEHlTEC-TEHj l C 0 0 2 8 l 5 6 *,ULl 0 9H+

0.00 l 7.96l l172lDNTlP 1l l

' 28l 36l04/96l l C lTEC-TEHlTEC-TEHl l0C006l550ULlVMa+

3.57 l 8,72l l179lDNTlP 1l l

, 40l 36l04/96l lC lTEC-TEHlTEC-TEH) l00:18l5f 3ULl02C+ 36.67 l22.27l l175lDNTlP 1l l

l 41l 37l04/96l l C lTEC-TEHlTEC-TEHl l00:18l5E:ULlVM - 2.15 l 8,78l jl74lDNTlP 1l l

69l 37l04/961 l C lTEC-TEHlTEC-TEHj l0:026l563ULlVM + 24.58 l 7.68l l180lDNTlP 1l l

f 91l 37l04/961 lC lTEC-TEHlTEC-TEH!

l0**29l56 ULl09H+

0.00 l52.0Pe l174lDNTlP 1l l

931 37l04/961 lC lTEC-TEHlTEC-TEH) l00:28l5!:ULl09H+

0.00 l26.01) l176lDNTjP 1l l

l 97l 37l04/96l l C lTEC-TEHlTEC-TEHl l0:028l5i:ULl09H+ u.00 l32.32l l178lDNTlP 1l l

I

40) 38l04/96!

lC lTEC-TEHlTEC-TEHl l C * *.03 l 51:ULj c2H+ 33. 31 l 5.53l l174lDNTlP 1l l

l 92l 38l04/96l l C lTEC-TEHlTEC.TEHi lC:;28l5i:ULl09He 0.00 l15.59l l176lDNTlP 1l l

941 39l04/96l lC lTEC-TEHlTEC-TEHi l0:029]Si:ULl09H+

0.00 l55.67l l177lDNTlP lj l

98l 38l04/961 l C lTEC-TEHlTEC-TEHj lC 029lSi:ULl09H+

0.00 l43.29l l177lDNTlP 1l l

.00l 38l04/96l lC lTEC-TEHlTEC-TEH{

l0:*28l52:ULj09H+

0.00 l37.59l l176lDNT[P 1]

l h

69l 39l04/96; l C lTEC-TEHlTEC-TEH, lC"!26lSi:ULlVM + 25.11 l 7.00l l173lDNTlP 1l l

91l 39l04/96!

lC lTEC-TEHlTEC-TEHj l C :2 9lSi:ULlC9H+

0.00 l61,00l l177lDNTlP 1l l

I 93l 39l04/961 l C JTEC-TEHlTEC-TEHi lC :28l5E ULl09H+

0.00 l61.77]

l176lDNTlP 1l l

95l 39104/961 l C lTEC-TEHlTEC-TEHi l0:2 2 9 l 5 6 *UL j 0 9H+

0.00 l57.41l l178lDNTlP 1l j

.117l 39l04/96l lC lTEC-TEHlTEC-TEHI l00:28l56:ULl10H+

0.00 l 9,02l l177lDNTlP 1l l

l l04/96!

l C lTEC-TEHlTEC-TEH)

{ C;;2 A l5 5:ULl09C+ 18.4 9 l46,73l l170lDNTjP 1l l

l l54/96:

lC lTEC TEHITEC-TEHj l0:*2Sl56:ULl090+ 17.63 l30.91l l171lDKTjP 1l l

l l04/961 lC lTEC-TEHlTEC-TEHt l 0 0 :28 l 5 6 ;ULl 0 90+ 14.94 l23.59l l170lDNTlP 1l l

l lD4/96!

lC lTEC-TEHjTEC-TEHj l0:02Bl56:ULl09C+ 13.78 l10.10l l171lDNTjP 1l l

l l04/96i lC lTEC-TEHlTEC-TEHl l0:026 l56:ULl09C+ 10.87 l11.98l l170lDNTlP 1l l

l

[04/96l l C lTEC TEHlTEC-TEHf l0 *28l56:ULl09C+

9.32 l22.43l l174lDNTlP 1l l

j i

l l04/96!

lC lTEC-TEHlTEC-TEHj l00:28l5E;ULl09C+

8.82 l27.70l l174lDNT]P 1l l

l l04/96j 1C lTEC-TEHlTEC-TEHl l00:26l5E;ULl09C+

8.34

'25.43l l172lDPrTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00:28]5E:ULl09C+

1.87 l10.311 l171lDNTlP 1l l

f 28l 40l04/961 l C lTEC-TEHlTEC-TEHj l00:06l56:ULlVM +

1.94 l 7.32l l174lDNTlP 1l l

40l 4Djo4/9F.

IH lTEH 03HlTEH-03Hl l0:169l51'FLl02H+ 33.16 l82.79l l176lDNTlP 1l l

l

[

88l 40l04/96l l C lTEC-TEH]TEC-TEHl l00
2?l56:ULlVM + 20.51 l 9.54l l182]DNTlP 1l l

94l %l04/96j l C lTEC-TEHlTEC-TEHj l0 *28l5E;ULl09H+

0.03 l76.94]

l181lDNTlP 1l l

J

100l 40l04/96l lC l REC-TEH lTEC-TEH j l00:29l58:ULl09H+

0,00 l20.46l l379lDNTlP 1l l

102l 40l04/96l l C lTEC-TEHlTEC-TEHl l0:*28l5t:ULl09H-0.30 l53.07l l178lDNTlP ll l

I 59l 41l04/961 l C lTEC-TEHlTEC-TEH!

l00:21l5f:ULlTSC+ 22.39 l 9.43l l180lDNTjP 1]

l 69l 41l04/96i l C lTEC-TEHlTEC-TEH[

l0C;03l56:ULlVM + 24.01 l 5.41l l174lDNTlP 1l l

91l 41l04/96l l C lTEC-TEHlTEC-TEHl l00:29l56:ULl09H+ 0,00 l97.18l l176lDNTlP ll l

[ 93l 41l04/96l lC lTEC-TFHjTEC-TEHl l00:26l56:ULl09H+

0.12 l19.38l l182lDNTlP 1l

}

' _ I _1 l._ l 1

I I

I I

1 _ L_I_ l _ l _ I ROCKRIDGE TECENOLOGIES i

l

n _.

I CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERATCli.

11 PAGEt 1 OF 22 OtTTA7E DATA SE**

z CURRENT DATE:

06/06/96 SELEC00N VARIMLES ; Percent TIME:

03:40r45 l

l l EXAM' l

l EXAM EXTENT l l

l' l

l l

lkOWi'ONl DATE HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l14 CATION l VOLTS l MIL lDEGl % lCH lCHNGl l _. l._ I l_l 1

l_l l

1 l

(_I_

L_L_l_l l 95l 41l04/96-l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l71.73l l176lDNTlP1l l

l 97) 41l04/96 l C lTEC-TEHlTEC-TEHl l00028]580ULl09H+ 0.06 l48,06]

l184 lDNTlP 1l l

l 99l 41l04/96 l C lTEC-TEHlTEC-TEHl l00029l5POULl09H+

0.00 l26.85l l177lDNTlP1l l

l101l 41l04/96 l C lTEC-TEHlTEC-TEHl l 00'02 8 l 5 8 0UL l 0,9H +0.03 l78.95l l181lDNTlP 1l l

l103l 41l04/96 lC lTEC-TEHlTEC-TEHj l00029l580ULl09E+

0,00 l3 9. 51l l176lDNTlP1l l

i l117l 41l04/96 l C lTEC-TEHlTEC-TEHl l00028l58DULl09H+ 6.27 l 5.72l l181lDNTlP1l l

l 10 l 42l04/96 l C lTEC-TEHlTEC-TEHl l00104l580ULlVM + 0.86 l13.20l l173lDNTlP1l l

l 92) 42l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl0'9H+ 0.00 l45.98l l178lDNTlP1l l

l 94] 42l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l15.51l l179lDNTlP 1l l

l 96i 42l04/96 lC lTEC-TEHlTEC-TEHl l00028l580ULl09W+ 0.03 l74.81l l182lDNTlP 1l l

(

l 981 42l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l117.1l l177lDETjP lj l

l10Cl 42l04/96 l C lTEC-TEHlTEC-TEHl l00028l580ULj09H+ 0.00 l81.32l l181lDNTlP lj l

l102i 42l04/96 l C lTEC-TEHjTEC-TEHl l00029l580ULl09H+

0.00 l 8 3 '. 77 l l177lDNTlP 1l l

l104i 42l04/96 l C lTEC-TEHlTEC-TEHl l00028l580ULl099+ 0.12 l 6.73l l170lDNTlP1l l

l106. 42l04/96 lC lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l31.86l l178lDNTlP 1l l

l120; 42l04/96 lC lTEC-TEHlTEC-TEHj l00028l580ULlVM + 79.55 l 6.08l l178lDFTlP1l l

l 69! 43l04/96 l C l TIC-TEHlTEC-TEHl l00026j580ULl08H+ 6.73 l 6.53l l167lDNTlP 1l l

l l04/96 l C lTEC-TEHlTEC-TEHl l00026l580ULl08H+

8.01 l 9.06l l168]DNTlP 1l

]

l l

lD4/96 l C lTEC-TEHlTEC-TEHl l00026l580ULlD" + 2.23 l11.93l l167lDNTIP 1l l

l l

l l04/96 lC lTEC-TEHlTEC-TEHl l00026l5800Ll08C+

7.83 l 6.52l l172lDNTlP 1l l

l 91; 43l04/96 lC lTEC-TEHjTEC-TEHl lC0029l580ULl09H+

0.00 l50.85!

l178lDNTlP1l l

l l

[04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09C+

1.46 l10.86l l172lDNTlP 1l l

{

l 93j 43l04/96 lC lTEC-TEHlTEC-TEHl l00026l580ULl09n+

0.06 l47.08l l183lDNTlP 1l l

l l 95i 43l04/96 l C lTEC-TEHlTEC-TEH]

lG0029l580ULl09H+

0.00 l69,14l l178lDNTlP 1l l

l 97: 43l04/96 l C j!EC-TEHlTEC-TEHj l00028l580ULl09H- 0.06 l163.0l l178lDNTlP 1l l

l 991 43lO4/96 lC lTEC-TEHjiEC-TEHl l0 029l580ULl09H+

0.00 l68.02l l177lDNTlP 1l l

l l103! 43l04/96 lC iTEC-TEHlTEC TEHl l00029l580ULl09H+

0.00 l72.27l l177lDNTlP 1l l

}

l106: 43l04/96 l C { TEC-TEHlTEC-TEHl l m 2Gl580ULl09H+

0.09 l78.31l l180lDNTlP 1l l

l119: 43l04/96 lC lTEC-TEHjTEC-TEHl l00029l580ULl09H+ 19,15 l11.10l l177]DNTjP 1l l

l l04/96 lC lTEC-TEHlTEC TEHl l00029l5BOULl09H+20.15 l 8.35l l176lDNTlP 1l l

l 28; 44104/96 l C lTFC-TEH]TEC-TEHj

!00006l5BOUL]VM + 2.05 l12.11l l175lDNTlP 1l l

} 54i 44l04/96 lC lTEC-TEHlTEC-TEHl l00023l580ULl07H+ 15.35 l 5.10l l177lDNTlP1l l

l 92l 44l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l95.99l l177lDNTjP 1l l

l 94l 44l04/96 lC lTEC-TEHlTEC-TEHl l00028l580ULl09H+

0.06 l125.6l l179lDNTlP 1l l

l l

l04/96 l C lTEC-TEHlTEC-TEHj l00028l5800Ll03C+

7.84 l14.89l l184lDNTlP 1l l

l 961 44l04/96 lC lTEC-TEHlTEC-TEHl l00029l580UL]O9H+

0.00 l41.17l l179lDNTlP 1l l

l l 981 44l04/96 lC l TEC-TEH lTEC-TEH j l00028l580ULl09H+

0.00 l80.26l l180lLNTlP lj l

l100) 44l04/96 lC lTEC-TEHlTEC-TEHj l00029l580ULl09H+

0.00 l42.64l l178lDNTlP 1l l

(

l102l 44l04/96 lC lTEC-TEHlTEC-TEHl l0002Bl580ULl09H+

0.00 l72.64l l182lDNTlP lj l

l104l 44l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULjo9H+

0.00 l78.14l l178lDNTlP 1l l

l112i 44l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l20.74l l180lDNTlP 1l l

j 57! 4bl04/96 lC lTEC-TEHjTEC-TEHl l00022l5BOULl02C+

9.00 l 5.71l l180lDNTl 1l l

l l 69l 45l04/96 lC lTEC-TEHlTEC-TEHl l00026l580ULlW + 23.00 l 5.95j l170lDNTlP 1l l

(

l 91l 45l04/96 lC lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l60.77]

l178lDNTlP 1l l

l 93! 45l04/96 lC lTEC-TEHlTEC-TEHj l00028l5800Ll09H-0.09 l132.2l l179lDNTlP 1l l

l_L _I L._. I I

l__ l l__

I I

L_.L_ L_I__.l _ 1 ROCKRIDGE TECHNOLOGIES e

I

CUMULATIVE REPORT 04/06, BCE, CRLVERT CLIFrs, UNIT 1 l

STEAM CENFRATOR

11 PAGE:

4 OF 22 OUTAGE DATA SET

CURRENT DATE:

06/06/96 3

SELECTICN VARIABLES: Percent TIME:

03:40:45 l

'l l EXAM l l

j EXAM EXTENT l l

l l

l l

l ROW lL;Nl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L_ l_ l l

L_1 l

l __. I I

I I

L _I_I_ l_._I l

l 95l 45l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l44.24]

l178lDNTlP 1l l

1 l 97l 45l04/96l l C lTEC+TEHlTEC-TEHl l00028l580ULl09H+

0.00 l28.19l l181lDNTlP 1l l

l 99l 45l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l33.37l l177lDNTlP 1l l

j l101l 45l04/96l l C lTEC-TEHjTEC-TEHj l00028l580ULl49H-0.06 l32.41l l182lDNTlP1l l

l103l 45l04/96l l C lTEC-TEHjTEC-TEHj l00029l580ULl09H+ 0. 0f' l14.67l l178lDNTlP 1l l

l105 j 4 5 l04/96l l C lTEC-TEHlTEC-TEHl l 00028 l 58'0UL] 09H+0.15 l 7.19l jl81lDNTlP 1l l

S l109) 45l04/96l l C lTEC-TEHlTEC-TEHl l 0002 R j 5800L } 0,9H+

1.15 l 9.37l l181lDNTlP1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHj l00028l580ULl04C+'3,59 l23.55l l178lDNTlP 1l l

l 28l 44104/96l l C lTEC-TEHlTEC-TEHl l00041l580ULlVM + 2.10 l 8.30l l172lDNTlP 1l l

5 l 40l 46!04/96l l C lTEC-TEHlTEC-TEHl l00041l580ULl05H+ 11.21 l 7.61l l172lDNTlP 1l l

l 92l 4fl04/96l l C lTEC-TEHlTEC-TEHj ju0030l580ULl09H+

0.00 l127.4l l174 lDNTl P "1l l

l 94l 4fj04/96l l C lTEC-TEHjTEC-TEHj l00030j580ULl09H+

0.24 l24.37l l176lDNTlP 1l l

l 96l 4fl04/96l l C lTEC-TEHlTEC-T5'Hj l00030l580ULl09H+

0.00 l74.29]

l175lDNTlP 1l l

l 98) 4 5104/961 l C lTEC-TEHlTEC-TEHl l00030l580UL]O9H+

0.00 l73.00l l178 lDNTlP 1l l

l100l 4?l04/96l l C lTEC-TEnjTEC-TEHl l00030l500ULl09H+

0.00 l52.79]

l178lDNTlP 1l l

l202l 4fl04/96l lC lTEC-TEHlTEC-TEHl l00030l580UL]09H+

3.12 139.34l l177lDNTlP lj l

l110l 4f jo4/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

3.15 l 5.67l l177!DNTlP lj l

4 l114l.* 04/96l l C lTEC-TEHlTEC-TEHl l00030l5800Ll09H+

3.12 l29.98l l178'DNTlP 1l l

l 41l 4'!04/96l l C lTEC-TEHlTEC-TEHl l Col 23l580ULlVM -

1.92 l11,99j l175lDNTlP ll l

l 69l 4*!04/96l l C lTEC TEHlTEC-TEHj l00123l580ULlVM + 24.68 l 5.66l l179lDNTlP 1l l

l 91) 4" 04/96l l C lTEC-TEHlTEC-TEHj l00030l580ULjo9H+

3.00 l80.75l l176 lDNTlP 1l l

l 93l 4" 04/96l lC lTEC-TEHlTEC-TEHj l00030l580ULl09H+

3.03 l91.56l l176lDNTlP 1l l

l 95) 4~ 04/96l l C lTEC-TEHlTEC-TEHj l00010l$80ULl09H, 3.00 l77.14l l177lDNTlP 1l l

l 97l 4~404/96l l C lTEC-TEHlTEC-TEHl l00030l500ULl09H+

3.00 l16.93l l178lDNTlP 1l l

l 99l 4",04/96l lC lTEC-TEHlTEC-TEHj l00030l580VLl09H+

3.00 l50.38l l176lDNT;( 1l l

l105 l 4",04/96 l l C lTEC-TEHlTEC-TEHl l00030{580ULl09H+

3.00 l24.49l l177!DNTlP 1l l

l315l 4* 04/96]

lC lTEC-TEHlTEC TEHl l00030l580ULl09H+

3.00 l14 51l l178!DNTlP 1l l

l 761 4 f :04/96l l C lTEC-TEHlTEC-TEHl l00118l$800Ll07H+

5.08 l 5.42l l176!DNTlP 1l l

l100l 41!04/96l l C lTEC-TEHjTEC-TEHj l00030l580ULl09H+

0.00 l108.1l l377]DNTlP 1l j

l102l 4i!D4/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

3.00 l22.12l l178lDNTlP 1l l

l1101 4f!04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.15 l16.38l l177IDNTlP 1l l

l114l4i104/96l l C lTEC-TEHjTEC-TEHl l0003015800Ll09H+

3.15 l37.37l l178lDNTlP 1l l

l126l 4i104/96l l C lTEC-TEHlTEC-TEHl l00096l580ULlVC +

7.42 l 7.20l l181lDNTlP 1l l

l 69l 4F204/96l lC lTEC TEHlTEC-TEH}

l00109l5000LlVM + 21.64 l 5.23l l177lDNTlP 1l l

l 91l 4 ? ;04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09C+

1.15 l 9.09l l174lDNTlP 1l l

l 93l 4)l04/96l l C lTEC-TEHlTEC-TEHl

{00030l580ULl09H-0.03 l26.81l l178tDNTlP 1l l

l 95l 4s iO4/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.09 (37.99l l178]DNTlP 1l l

.l101l 4i104/96 l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.00 112.44l l179fDNTlP 1l l

l103] 4 ;- i O4/96 l lC lTEC-TEHlTEC-TEHl l00030l580ULj09H+

0.00 l19.09l l100lDNTlP lj l

l105 l 4 & 4 04/96l l C lTEC-TEHlTEC-TEHl l0DC30l580ULl09H+

0.09 l 9.81l l178lDNT[P lj l

l109l 4)!O4/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09H-0.09 l 5.85l l177lDNTlP 1l l

l111l 47:04/96l lC lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.00 l a.75l l179lDNTlP lj l

l115l 49104/96l l C lTEC-TEHlTEC-TEHl l00030l500ULl09H+

0.06 l24.84l l178lDNTlP 1l l

l121] 4i!04/96) l C lTEC-TEHlTEC-TEHj l00030l580ULl09H+

0.24 l13.09l l178]DNTlP 1l l

l 92l E !04/96l lC lTEC-TEHlTEC-TEHl l00031l580ULl09H-D.12 l24.96l l100lDNTlP 1l l

L_ l _

_l l._ I I

l_1 I

I I

l _ l _._. L_. l _ l __ I ROCKRIDGE TECHNOLOGIES

I 4

k 1

CUMULATIVE REPORT 04/96, BGE, CnLVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

5 OF 22 OLTTAGE DATA 6ET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIMEi 03:40:45

)

b l

l

-l EXAM l l

l EXAM EXTENT j l

l l

l l

l ROW lLINl DATElHEATWl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lD"Gl t lCH lCHNGl l_l l

I l_l l

1._ I l

1 i

L_ L l _ L l.,_l l

l l04/96l l C lTEC-TEHlTEC-TEHj l00031l580ULl08C+ 21.19 l 6.15l l176lDNTlP 1l l

l 94l 50l04/96l~

l C lTEC-TEHlTEC-TEH]

l00030l580ULl09H-0.06 l47.79l l182lDNTlP 1l l

l 98l 50l04/96l l C lTEC-TEHlTEC-TEHj l00010l580ULl09H+

0.00 l42.87l l179lDNTlP 1l l

l100l 50]O4/96l l C lTEC-TEHlTEC-TEHj l00631l580ULl09H+

0.00 l38.68l l180lDNTlP 1l l

l102l 50l04/96l lC lTEC-TEHjTEC+TEHl l00030l580ULl09H+ C 00 l38.43l l180lDNTlP 1l l

l 91l 51l04/96l l C lTEC-TEHlTEC TEHl l00031l580ULl09H+

0.00 l37.94l l179lDNTlP 1l l

l l

l04/96l lC lTEC-TEHlTEC-TEHj l00031l560ULl09H+ 2.12 l 9.26l l177lDNTlP 1l l

l l 931 51l04/96l l C lTEC-TEHITEe-TEHj l000301580ULl09H+

0.06 l75.79) l178lDNTlP ai l

l 95l 51l04/96l l C lTEC-TEHlTEC-TEHl l00031l580VLl09H+

0.06 l41.59l l180lDNTlP l

l101l 51l04/96l lC lTEC-TEH]TEC-TEHl l00030l580ULl09H+

0.00 l68.16l l178lDNTlP 1l l

l103l 51l04/961 lC lTEC-TEHlTEC-TEHl l00031l580ULl09H+

C.09 l29.30]

{180lDNTlP 1l l

l105] 51l04/96l lC lTEC-TEHlTEC-TEHj l00030l580ULl09H+

0.00 l10.91]

l179lDNTjP lj l

l117l 51l04/961 l C lTEC-TEHlTEC-TEHl l00030l500ULlDH +

8.61 l16.80l l178lDNTlP 1l l

l 28] 52l04/96l l C lTEC.TEHjTEC-TEHI l00:45l580uL]vm + 2 73 l 5.62l 1174lDNTIP 1l l

l 921 52}04/96l lC lTEC-TEHlTEC-TEHj l00031l580ULl09H+

c.09 l93.11l l178lDNTlP lj l

l 94l 52l04/96l lC lTEC-TEHlTEC-TEHj l00:30l580ULl09H-0.03 l69.32l l178lDNTlP lj l

l100l 52l04/96l lC lTEC-TEHlTEC-TEHj l00:31lf20ULl09H+

C.00 l99.28l l175lDNTlP 1l l

l l102l 52l04/96l lC lTEC-TEHlTEC-TEHl l00:30l580ULl09He 0.03 l80.61l l181lDNTlP 1l l

l104l 52104/96l lC lTEC-TEHITEC-TEHl loc:31l58autl09H+

t,.06 626.51l l180lDNTlP 1l l

l106l 52104/96l lC lTEC-TEHlTEC-TEHl l00:30l580ULlD9H+ C 03 l19.68l l178lDNTlP lj l

l 91l 53l04/96l lC lTEC-TEHlTEC-TEHj l0C031l5800Ll09H-0.33 l78.29l l177lDNTlP 1l l

.l l 93l 53l04/961 lC lTEC-TEHlTEC-TEHj l 00:3 a l 5 e cuLl 09H e C.00 l97.52l l178lDNTIP il l

l 95l 53104/96l lC lTEC-TEHlTEC-TEHj l00:31l580ULl09H-C.03 l101.9l l179lDNT'P 1]

l l 99l 53l04/96l lC l TEC-TEH l TEC-TEH j l00:31l500ULl09H-C.33 l13.10l l178lDNTlP 1l l

l101l 53l04/96l lC lTEC-TEHlTEC-TEHl l0C 30l5800Ll09H.

C.06 l48.13l l178lDNTlP il l

l103l 53l04/96l l C lTEC-TEHlTEC-TEHl l0CC31l580ULl09He 0.00 l98.93l l178lDNTlP 1l l

l105l 53l04/96l lC lTEC-TEHlTEC-TEHl l0C:30l5BDULl09He C 00 l102.8l l177lDNTlP lj l

l107l 53[04/96l lC l'1 EC-TLH lTEC-TEH ]

l000 1l560VLl09H+

0.06 l49.87l l179lDNTlP 1l l

11091 53104/961 l C lTEC-TEHlTEC-TEHl l00:3 3 l58 006l 09H.

.03 134,78l l177jDNTlP 1l l

t l111] 53l04/96l lC lTEC-TEHlTEC-TEHj l00031l580ULl09H-0.06

[23.06l l181lDNTlP 1l l

l 30l 54l04/96l lC lTEC-TEHlTEC-TEHl l0C046l580ULlVM +

4.81 l 7.21l l178lDNTIP 1l l

l 92l 54l04/96l lC lTEC-TEHlTEC-TEHl l00:30l580ULl09H+

0.00 l69.82l l178lDNTlP lj l

l 94l 54l04/96l l C lTEC-TEHlTEC-TEHl l00:31l580ULl09H+

0.09 l78.50]

l180lDNTlP 1l l

l 96l 54l04/96l l C lTEC-TEHjTEC-TEHl l0003Dl5800Lj09H-C.12 l99.02l l182]DNTlP 1l l

l 98l 54l04/96l lC lTEC-TEHlTEC-TEHl l00031l5800Ll09H+

D.00 l45.73l l180lDNTlP 1l l

l100] 54j04/96l l C lTEC-TEHlTEC-TEHl l00:3Dl580ULl09H+

0,03 176.35l l179lDNTlP 1l l

l102l 54l04/96l lC lTEC-TEHlTEC-TEHj l00C31l580ULlJ9H-D.03 l120.7l l176lDNTlP 1l l

l104l 54l04/96l lC lTEC-TEHlTEC-TEHj l00031l580ULl09H+

0.12 l45.41l l179lDNTlP 1l l

l110l 54l04/96l lC lTEC-TEHlTEC-TEHl l00C30l580ULl09H+

0.00 l12.69l l179lDNTlP 1l l

l 91l 55104/96l lC lTEC-TEHlTEC-TEHl l00031l580ULl09H+

0.00 l53.90]

l179lDNTlP 1l l

l 93l 55l04/96l lC lTEC-TEHlTEC TEHj l00030l580ULl09H-0.03 l50.50l l177lDNTlP 1l l

l 95l 55l04/96l lC lTEC-TEHlTEC-TEHj l00031l580VLl09H+

0.15 l10.99l l180lDNTlP 1l l

l 97l 55j04/96l lC lTEC-TEHlTEC-TEHl l00030l580ULl09H-0.03 l86.40l l178lDNTlP 1l l

l l

jo4/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09C+

3.85 l 6.02l l175lDNTlP 1l l

l 991 55l04/96l lC lTEC-TEHjTEC-TEHl l00:31l580Unl09H.

0.03 l52.95l l179lDNTIP 1l l

1 l_l-1 I_

I 1

1 _l l

I I

L._ L_ I_ l I_ l ROCKRIDGE TEC'HNOLOGIES

^

i i

CtWOLATIVE REPOST 04/06, BG/., CALVERT CLIFFS, UNIT 1 1

STEAM GENERATOR

11 PAGE:

6 OF 22 OUTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 j

l l EXAMl l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl i

!_k I I_l l

l-l l

l l

l_ l_l l

l~l l101l 55l04/96l l C lTEC-TEHlTEC-TEHl l00030l5800Ll09H+

0.03 l114.9l l178lDNTlP 1l l

l103) 55l04/96l l C lTEC-TEHjTEC-TEHl l00031l580VLl09H+

0.06 l82.64l l179lDNTlP 1l l

l105] 55l04/96l l C lTEC-TEHjTEC-TEHl l00030l58CULl09H+

0.06 l35.83l l180lDNTlP 1l l

l111] 55l04/96l l C lTEC-TEHlTEC-TEHl l 00031 l 580UL l 0,pH-0.06 l30.20l l180lDNTlP 1l l

j l113l 55l04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.15 l 9.19l l177lDtiflP 1l l

l 20l 56l04/96l l C lTEC-TEHlTEC-TEHl l00047l58hULl05H+ 31.48 l 5.32l l174lDNTlP 11 l

l 28l 56l04/96l l C lTEC-TEHlTEC-TEHj l00047l580ULlVM + 1.95 l20.98l l174lDNTlP 1l l

l 74l 56l04/96l l C lTEC-TDilTEC-TEHl l00119l580ULl04H+ 27.37 l 5.31l l172lDNTlP 1l l

l 92l 56l04/96l l C lTEC-TEHjTEC-TEHj l00033l580ULl09H+

0.03 l35.35l l185lDNTlP 1l l

l 94l 56l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l135.5l l173lDFrjP 1l l

l 96l 56j04/96) l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.00 l65.80l l100lDNTlP 1l l

I l100! 56l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l60.42l l181lDNTlP 1l l102l 36l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l19.47l l176lDNTlP 11 l

{

l1041 56l04/96l lC lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l71.18l l180lDNTlP7l l

l106; 56l04/961 l C lTEC TEHlTEC-T*Hj l00032l580ULl09He 0.00 l31.37l l176]DNTlP 3l l

l110! 56104/96l l C lTEC-TEHjTEC-Te.4l l00030l580ULl09H+

0.09 l11.80l l179lDNTlP ll l

l112; 56l04/96l l C lTEC TEHlTEC-TE:l l00031l580ULl09H+

0.00 l11.12l l181lDNTlP 1l l

l118! H l04/96 l l C lTEC-TEHlTEC-TEHl

.,030j580ULl05C+ 14.54 l 5.13l l177lDNTlP 1j l

l 91) 57104/96i l C lTEC-TEHjTEC-TEHj l00033l5800Ll09H+

0.00 l37.15l l181lDNTlP 1l l

{

} 931 57l04/96i l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l122.8l l174lDNTlP 3l

[

l l 956 57l04/96l l C lTEC-TEHlTEC-TEHl l00033l5BOULl09H+

0.09 l103.1l l184lDNTlP 1l l

l 97! 57l04/961 l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l131.2l l174lDNTlP 1l l

]

[ 99l 57l04/96!

l C lTEC-TEHlTEC+TEHl l00033l5800Ll09H+

0.00 l25.96l l181lDNTlP 1l l

l101! 57l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l35.81l l176lDNTlP 1l l

i l103) 37l04/96l l C lTEC-TEHlTEC-TEHj l00033l5800Ll09H+

0.00 l14.20l l152lDNTlT 1l l

l105l 57l04/961 l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+

0.00 l35.43l l176lDNTlP 1l l

l107l 57l04/96l l C lTEC-TEHlTEC-TEHl l00033l500ULl09H+

0.00 l26.57l l181lDNTlP 1l l

l l111j E7l04/96l lC lTEC-TEHjTEC-TEHl l00033l580ULl09H+

0.00 l18,09l l182lDNTjP 1l l

l 40; 56l04/96l l C lTEC-TEHlTEC-TEHl l00047l580ULlC2H+ 36.59 l52.72l l177lDNTlP lj l

l j

104/96l l C lTEC-TEHlTEC-TEHl l00047l580UL]D3H-0.74 l10.10l l177lDNTlP 1]

l I

[ 82j 56104/96l l C lTEC-TEHlTEC-TEHl l00119l580ULl03H+

4.60 l12.86l l173lDNTlP 1]

l l 92i 58l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l30.58l l181lDNTlP 1l l

l 94) 58l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H-0.06 l151.4j l176lDNTlP 1l l

l 96i 56l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l56.46l l181lDNTlP 1l l

l 98l 58l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l57.17l l177lDNTjP 1l l

l100] 58l04/961 lC lTEC-TEHlTEC-TEHl l00033l5BOULl09H+

0.00 l22.69l l184lDNTlP lj l

l102l 58l04/96l l C lTEC-TEHjTEC-TEHj l00032l580ULj09H+

0.00

' 7 59l l175lDNTlP 1l l

l1064 58l04/96l lC lTEC-TEHlTEC-TEHl jo0032l580ULl09H+

0.00 07l l176lDNTjP 1l l

l112l 56l04/96i l C lTEC-TEP/TEC-TEHj l00033l5800LlVC + 14.22 l 5,02l l181lDNTjP 1]

l l 41l 59l04/96l

[ C [TEC-TEHlTEC-TEHl l00113l5800LlVM -

1.86 l 8.90l l171lDNTlP 1]

l l 91l 59l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l43.01l l181lDNTlP 1l l

l 93; 59l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00

[127.7l 1173lDNTlP 1l l

l 951 59l04/96l l C lTEC-TEHlTEC-tdt l l00D33l580ULl09H+

0.00 l65.41l l182lDNTlP 1l l

l 97l 59l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l48.49l l176lDNT[P 1l l

l105! 59l04/961 l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l15.00l l177lDNTlP 1l l

LtI i

l_i l

Ll l

l l

L_. I_ L._ L I_ l ROCKRIDGE TECHNOLOGIES

. ~.

i I

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM OENERATOR 11 PAGE 7 OF 22 OUTAGE OATA SET r CURRENT DATES 06/06/96 SELECTI C VARIABLES: Percent TIMES 03:40145 l

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lL3 DATEl HEAT 81 LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l IDCATION l VOLTS l MIL lDEGl % lCH l CILTil L I _._.

I L_ l-I L._. ]

I I

I I ___ l _ l _ l _ l __ l l107) Sir 04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l 5.831 l180lDNTlP 1l l

l 40l 6" 04/96l l C lTEC-TEHjTEC-TEHl l00047l580ULj01H+ 23.87 l 8.59l l178lDNTlP 1l l

l l 78l 6; 04/96l l C lTEC-TEHlTEC-TEHj l00119l580ULl01H+ 28.16 l 5.08l l182lDNTlP 1l l

)

l 92l 6; 04/96l l C lTEC-TEHlTEC-TEHj l00033l580ULl0pH- 0.12 l86.91l l184lDNTjP 1l l

l 94]

6' 04/96l l C lTEC-TEHjTEC-TEHl l00032l5800Ll09H+ 0.00 l80.11l l175lDNTlP1l l

l 96l 6: 04/96l l C JTEC-TEHlTEC-TEHl jo0033l588ULl09H. 0.14 l71.88l l179lDNTlP lj l

l 98l 6; 04/96l l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+

0.00 l57.36l l177lDNTlP 1l l

l 41l 6- 04/96l C lTEC-TEHlTEC-TEHl l00115l580ULlVM -

1.94 l11.58l l172lDNTlP 1l l

4 l 47l (* 04/96l i C lTEC-TEHjTEC-TEHl l00113l580ULlTSH+18.89 l12.94l l173lDNTlP 1l l

l 91l E*. 04/96l

! C lTE'C-TEHlTEC-TEHj l00033l580ULl09H- 0.33 l90.27l l177lDNTlP 1l l

l l

04/96]

C lTEC-TEHlTEC-TEHl l00033l580ULl09C+

0.33 l 7.30l l357lDIClP 1l l

l 93l (*. 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l75.62l l174lDNTlP 1l l

j 95l ff. 04/96l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.06 l20:71l l185lDNTlP lj l

l 97l

(*. 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 j91.42l l175lDNTlP 1l l

(

l 99l (;. 04/96l C lTEC-TEHlTEC-TEHj l00033l580ULl09H.

0.22 l47.97l l180lDNTlP lj l

l101l El 04/96l C lTEC-TEHlTEC-TEHl l00032l580VLl09H+

0.00 l40.58l l175lDNTlP 1l l

l103l i'. 04/96l C lTEC-TEHlTEC-TEHl l00033l580ULj09H+

0.00 l 7.67l l179lDNTlP 1l l

1105) (; 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l34.48l l175lDNTlP lj l

l107l ('. 04/96l C lTEC-TEHjTEC-TEHl l00033l580ULl09H-0.03 l28.26l l185lDNTlP 1l l

l109l (; 04/96)

C lTEC-TEl:lTEC-TEHl l00032l580ULl09H+

0.00 l24.91l l174lDNTlP 1l l

{

l113l fl 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l26.12l l176lDNTlP 1l l

l115) 04/96l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-0.28 l15.51l l182lDNTjP 1l l

1 l117) i; 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl10C-0.03 l 9.87l l17blDNTlP 1l l

l 92l (; 04/96l C lTEC-TEHlTEC-TdHl l00033l580ULl09H-0.39 l46.08]

l119lDNTlP 1l l

l 94l i' 04/96l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H.

0.06 l27.8Dl l183lDNTlP 1l l

l 96l f" 04/96l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+

0.00 l27.25l l175lDNTlP 1]

l l 98l f; 04/96l C lTEC-TEHlTEC-TEHj l00033l500ULl09H-0.42 l36.43l l182lDNTlP 1l l

l100l f; C4/96l C lTEC-TEHjTEC-TEHl l00032l580ULl09H+

0.00 l80.97j l176lDNTlP 1l l

l102l (; 04/96l C lTEC-TEHlTEC-TEHj l00033l580ULl09H+

0.0V l25.94l l182lDNTlP 1l l

l110l f* 04/96l C lTEC-TEHlTEC-TEHl lD0033l580ULl09H+

0.06 l21.33l l186lDNTlP 1l l

l 91l 63 04/96l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H-0.22 l58.51l l181lDNTlP 1l l

{

l l

04/96l C ITEC-TEHlTEC-TEHl l00033l580ULl09H+ 2.11 l 7.38l l175lD!TrlP 1l l

l 93l f3 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l68.48) l175lDNTlP 1l l

l 95] 63 04/96l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-0.03 l72.73) l186lDNTlP 1l l

l101l (? 04/96l C lTEC-TEHlTEC TEHl l00032l580UL]O9H+

0.00 l74.54]

l175lDNTlP 1l l

l103l 63 04/96l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H+

0.25 l22.16l l183lDNTlP1l l

l105l (3 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l92.81) l174lDNTlP 1l l

l107l 63 04/96l C lTEC-TEHjTEC-TEHl l00033l580ULl09H+

0.03 l73.75) l184lDNTlP 1l l

l109l 63 04/96l C lTEC-TEHlTEC-TEHl l00032l580ULl04H+ 13.65 l21.10l l172lDNTlP 1l l

l127l (3 04/96l C lTEC-TEHlTEC-TEHl l00095l580ULl09H+ 0.00 l 7.01l l180lDWTlP 1l l

l 92l 64 04/96l C lTEC-TEHjTEC-TEHl l00033l580ULl09H+

0.09 l41.55l l185lDNTlP 1l l

l 94 l (4 04/96l C lTEC-TEHjTEC-TEHj l00032l580ULl09H+

0.00 l73.01]

l175lDNTlP 1l l

l 98] 64 04/96l C lTEC-TEHlTEC TEHj l00032l580ULl09H+

0.00 (13.92l l176lDNTlP 1l l

l100l 64 04/96)

C lTEC-TEHjTEC-TEHj l00033l580ULl09H-0.03 l126.8) l182lDNTlP 1l l

l102l E4 04/96l C lTEC-TEHlTEC TEHl l00032l580ULl09H.

0.00 l55.31l l177lDNTlP 1l l

l_._ l _

I

_I I

l_1 1

I I

I.__ L _i_ l__! _ I ROCKRIDGE TECHNOLOGIES

w--..

~. --.

+- - - _.

=-

. ~.. -

+

CUMULATIVE P.EPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 3 M GENERATOR 11 PAGE:

8 OF 22

  • 7TAGE DATA SET CURRENT DATE:

06/06/96 5 ELECTION VARIABLES: Percent TIME:

03:40:45 l

l IXAMl l

l EXAM EXTENT l l

l l

l l

ROW lLINl OATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATICN l VOLTS l MIL DEGl t lCH lCHNGl l_._ t I

l _._ I I

l_ !

l l

l l _ _ _l

_l___l _ l 104l 64l04/96l l C lTEC-TEHjTEC-TEHl l00033l580ULl09H+

0.03 l18.71l 179lDNTlP 1l l

06l 64l04/96l l C lTEC-TEHjTEC-TEHj l00032l580ULl09H+

0.00 l50.67l

-176lDNTlP 1l l

57l 65l04/96l l C lTEC-TEHlTEC-TEHl l00117l580ULl02C+ 37.51 l52.49l 177lDNTlP 1l l

91l 65l04/96l l C lTEC-TEHlTEC-TEHj l00033l580ULl09H+ 0.00 l21.13l

.381lDNTlP 1l l

93l 65l04/96l l C lTEC-TEHjTEC-TEHj l00032l580ULl09H+

0.00 l39.97) 175lDNTlP 1l l

97l 65l04/96l l C lTEC-TEHlTEC-TEHj l 000341580'UL j o9H+

0.06 l34.57l 182lDNTlP 1l l

j 99l 65l04/96l l C lTEC-TEHjTEC-TEHl l00035l5800Ll09,H+

0.06 l72.14l 182lDNTjP 1l l

(

'01l 65l04/96l l C lTEC-TEHlTEC-TEHj l00034j580ULl09H+

0.00 l62.49l 182lDNTlP 1l l

  • D3l 65l04/96l l C lTEC-TEHjTEC-TEHl l00035l580ULl09H+ 0.03 j55.38l 180lDNTlP 1l l

f 105l 65l04/96l l C lTEC-TEHlTEC-TEHl l00034j5800Ll09H+ 0.00 l67.24l 181lDNTlP 1l l

92l 64l04/96l l C l1EC-TEHlTEC-TEHl l00035l580ULl09H-0.09 l35.32}

184lDNTlP il l

94l 66l04/96l l C lTEC-TEHlTEC-TEHj l00034l580ULl09H+

0.00 l 7.91l 182lDNTlP 1l l

98l 66l04/96l lC lTEC TEHlTEC-TEHl l00034l580ULl09H+

0.09 l22.41l 181lDNTlP ll l

' 30l 66l04/96l l C lTEC-TEHlTEC-TEHj l00035l580ULl09H+

0.03 l56 42l 184lDNTlP 1l l

i

  • 02l 66l04/96l

}C lTEC-TEHlTEC-TEHl l00014l580ULl09H+

0.06 l 6.18l 180lDNTlP 1l l

.10l 66l04/96l l C lTEC-TEHlTEC-TEH]

l00034l580ULl07H+ 22.56 l b.93l 179lDNTlP 1]

l 91l 67j04/96l l C lTEC-TEHjTEC-TEHl l00035l580ULl09H+

2.51 l i v, ** 9 l 179lDNTlP 1l l

33l 67104/96l lC lTEC-TEHlTEC-TEHj

[00034l580ULl09H+

".00 l50.49l

~8*2]DNTlP 1l l

95l 67l04/96l lC lTEC TEHjTEC-TEHl l00035l580ULl09H+

0.03 l54.74l 184lDNTlP 1l l

97l 67l04/96l l C lTEC-TEHlTEC-TEHl l00034l500ULl09H+

0.00 l15.19l 179lDNTlP 1l l

l 99l 67104/96l lC lTEC-TEHlTEC TEHl l00035l580ULl09H+

0,06 l32.67l 183lDNTlP 1l l

)3l 67l04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H+

0.06 l15.27l 187lDNTlP 1l l

135j 67l04/96l lC lTEC-TEHlTEC-TEHl

{00034l580ULl09H+

0.00 l22.78l 182lDNTlP 1l l

f 6l 68l04/96l l C lTEC-TEHlTEC-TEHl l00117l580ULl04H+ 12.19 l 6.07l

80lDNTlP 1l l

76l 68l04/96l l C lTEC-TEHlTEC-TEH) l00120l580ULl01C+ 17.16 l 6.25l 161lDNTlP 1l-l 92l 68l04/96]

l C lTEC-TEH]TEC-TEHl l00035l580ULl09H+

0.03

{36.29l

84lDNTlP 1l l

ii4 l 68 l04/96l lC lTEC-TEHlTEC-TEH}

l00034l580ULl09H-c.18 l29,67l

  • 81lDNTlP 1l l

i

!?D[ 68iO4/96l

) C lTEC TEHlTEC-TEHj l00035l580ULl09H+

0.03 l38.09l 184lDNTjP 1l l

l#1l 69l04/96l lC lTEC-TEHlTEC TEHl l00035l5900Ll09H-0.09 l45.29]

183lDNTlP 1l l

I 93l 69104/96l lC jTEC-TEHlTEC-TEHl l00034l5EDULl09H-0.12 l43.97l 181lDNTlP 1l l

l 95[ 69104/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H+

0.00 l63.37l 183lDNTlP 1l l

97l 69l04/96l l C lTEC-TEHlTEC-TEHl l00034l580ULl09H+

0.00 l24.43l 183lDNTlP 1l l

99l 69l04/96l

, C lTEC-TEM lTEC-TEHj l00035l580ULl09H+

0.15 l51.11l 182]DNTlP 1l l

  • 29l 69l04/96l l C lTEC-TEHlTEC TEHl l00096l580ULl05C+ 20.90 l26.23l 178lDNTlP ll l

I 92l 70l04/96l l C lTEC-TEHjTEC-TEHl l00037l580ULl09H+

0.06 l29.33l 177lDNTlP 1]

l 94l 70l04/96l lC lTEC-TEH}TEC-TEHl l00036l580ULl09H+ 0.20 l34.44l 178lDNTlP 1l l

96l 70j04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H+

0.27 l10.90l 184lDNTjP 1l l

98l 70l04/96l lC lTEC-TEHlTEC-TEHl l00130l580ULl09H+

0.00 l67.57l 180lDNTlP 1l l

  • D01 70l04/96l l C lTEC-TEHlTEC-TEHl l00035l580UL]O9H-0.03 l4 9,54 l 184lDNTlP 1l l

l 104/96l l C lTEC-TEHlTEC-TEHl l00035]5800LlDH + 12.95 l 8.60l 186lDNTlP 1l l

i 102] 70l04/96l lC lTEC-TEHlTEC-TEHj l00130l580ULl09H+

0.00 l56.69l 181lDNTlP 1l l

120l 70104/96l lC lTEC-TEHlTEC-TEHl l00035l580ULlVH +

3.53 l41.79l 173lDNTlP 1l l

l l04/96l lC lTEC-TEHlTEC-TEHl l00035l580ULl08C+

9.39 l13.06l 179lDNTlP 1l l

l l04/96l lC lTEC-TEHlTEC-TEHl l00035 j 5800Ll06C+ 18.42 l14.08l 180lDNTlP 1l l

l 104/96l lC lTEC-TEHlTEC-TEHl l 00035 l5B OULl 06C+ 17.36 l 6.24l 175lDNTlP 1]

l

)

_ f.__.:

I l _. I I

l_I I

l l

l_

l_l._l_l ROCKRIDGE TECHNOLOGIES

~.

~..

.-a CUMU1ATIVE REPORT 04/96, ECE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE:

9 0F 22 OUTAGE DATA SET i CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME 2 03:40:45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL DEGl % lCH lCHNGl l

l_l- _I I

l_l I

l_l l

I I

l_

__l L I i

l Gil 71l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09b 0.03 l 8.71l 284lDNTlP 1l l

l l 93l 71l04/96l l C lTEC-TEHlTEC-TEHl l00036l580ULl09b 0.03 l38.78]

,179lDNTlP 1l l

I l 95l 71l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09E- 0.06 l41.36l 178lDNTlP 1l l

l 97l 71l04/96l l C lTEC-TEHlTEC-TEHl l 00'036 l 58 0ULl 0,9E.

0.00 l21.61l 1179lDNTlP 1l l

l 99l 71l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl0Sb 0.20 l31.61l

'177lDNTlP 1l l

l101l 71l04/96l l C lTEC-TEHlTEC-TEHl l00036l58h0Ll09E.

0.00 l69.86l

'176lDttTlP 1l l

l107l 71l04/96j l C lTEC-TEHlTEC-TEHl l00036l580ULl09b 0.00 l 5.16l 180lDNTlP 1]

l l 72l 72l04/96l l C lTEC-TEHlTEC-TEHj l00116l$80ULlDH - 22.16 l10.65l 173lDNTlP 1l l

l 92l 72[04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09E- 0.09 l36.12l 178lDNTlP 1l l

l 96l 72l04/96l l C lTEC-TEHlTEC-TEHj l00037l580ULl09E-0.03 l 8.60l 178lDNTlP 1l l

l 98l 72l04/96l lC lTEC-TEHlTEC-TEHl l00036l580ULl09E-0.16 l94.53l 179lDNTlP 1l l

l200l 72l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09E- 0.26 l58.00l 178lDNTlP 1l l

l102l 72l04/96) l C lTEC-TEHlTEC-TEHl l00036l580ULl09E- 0.00 l43.10l 179lDNTlP 1l l

l104l 72l04/96l lC lTEC-TEHjTEC-TEHj l00037l5800Ll09E-0.03 l32.94l 178lDNTlP 1l l

l l110l 72l04/96l lC lTEC-TEHlTEC-TEHj l00036l580ULl09b 0.00 l10.35l 179lDNTjP 1l l

l120l 72l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULlVC -

4.46 112.85l

  • 75]DNTlP 1l l

l 35l 73l04/96l lC lTEC-TEHlTEC-TEHl l00048l580ULlVM -

0.00 l12.90l 181lDNTlP ll l

l 91l 73l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09b 0.06 l34.10l 177lDNTjP 1l l

l 93l 73l04/961 l C lTEC-TEHITEC-TEHI l :c36l580ULl09E 0.03 176.411 178lDNTlP 1l l

'l 95l 73l04/96l l C lTEC-TEHjTEC-TEHl l00037]S80ULl096 0.09 l29.10l 178lDNTlP 1l l

l l

l04/961 l C iTEC-TEHlTEC-TEHI l0 c37l580utl090 0.03 l 8.44l

.75lDNTlP 1l l

l 97l 73l04/961 lC lTEC-TEHlTEC-TEHl lCO:36l580ULl096 0.06 l81.87l 178lDNTlP lj l

l 99l 73l04/96l l C lTEC-TEH j TEC-TEH j l00037l580ULl09b 0.12 l43.83l

83!DNTlP 1l l

l 52l 74l04/96!

lC lTEC-TEHlTEC-TEH]

l C 0116 l 58 0ULl 04 0-5.80 l19.47l 175lDNTlP 1l l

l l 58l 74{04/96l l C lTEC-TEHlTEC-TEHl l0'117l580ULl01E 0.72 l 7.00l

  • 73lDNTlP 1l l

l l

l l04/961 lC lTEC-TEH ITEC-TEH I le:117l580utivM -

3.80 l c.59l

73]DNTIP ll l

l l

l04/961 i C lTEC-TEHlTEC-TEHl lC0117l580ULl060- 21.8e l16.02l

l 92} 74l04/96) l C lTEC-TEHlTEC-TEHl lCM40l580ULl09b 3.03 j49.96l 176lDNTlP 1l l

l 94l 74l04/96; I e {TEC-TEHITEC.TEHI lC: 401580ULl096 0.09 l20.93l

79lDNTIP al l

l102l 74l04/96l lC lTEC TEH{TEC-TEHl lC0038l580ULl09b 0.00 l14.16l

80lDifrlP 1l l

l114l 74104/96l lC lTEC-TEHlTEC-TEHl

[00038l580ULl07b 8.63 l 7.91l 172lDNTlP 1l l

l 69l 75l04/96!

lC lTEC-TEHlTEC-TEHl lC0117l580VLlDH -

7.57 l 5.30l

'.77lDNTlP 1l l

l 91l 75l04/96l l C lTEC-TEH{TEC-TEHl l00040l580ULj096 0.00 l58.19l 182lDNTlP 1l l

l l

l04/961 l C lTEC-TEHITEC-TEHI lc0 401580ULl09b 1.96 l 8.10l 76lDNTIP 11 l

l 93l 75l04/96{

l C lTEC-TEHITEC-TEHl l00040l500ULj09E-0.00 l 8.01l 180lDNTlP 1l l

l 95l 75l04/96) l C lTEC-TEHlTEC-TEHl l 00'039 l 580UL l 09E- 0.09 l43.31l

83lDNT]P 1l l

l 991 75]D4/961 l C lTEC-TEHlTEC-TEHl l00039l580ULl09b 0.15 l29.08l 182lDNTjP 1l l

l111l 75l04/96l l C lTEC-TEHlTEC-TEHl l00039l5800LlVM - 29.04 l 8.31l 175lDNTlP 1l l

l 92l 76l04/96i lC lTEC-TEHlTEC-TEHl l00040l580ULl09H-0.15 l12.11l 177lDNTlP 1l l

I l 94l 76l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09b 0.03 l68.61l 179lDNTlP 1l l

l 961 76l04/961 lC lTEC-TEHITEC-TEHl l00039l580utl09b 0.00 l29.861

81lDNTlP 1l l

l1101 76l04/961 lC l TEC-TEH l TEC-TEH l l00038l580ULl09b 0.00 l17.82l 178lDNTlP 1) l l 41l 77l04/961 1 C lTEC-TEHlTEC-TEHl l00120l580ULl01E-28.72 (12.53l 178lDNTlP 1l l

l l

l04/96!

lC lTEC-TEHlTEC-TEHj l00125l580ULl01E-28.72 l 9.71]

178lDNTlP 1l l

l 451 77l04/96]

lC lTEC-TEHlTEC-TEHl l00181l580ULlVM -

2.00 l 6.16l 174lDNTlP 1l l

l_L _l l_1 I

l_ I I

I I

L _. ___l _ I _ L _I ROCERIDGE TECIDf0LOGIES 4

1

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFPS, UNIT 1 STEAM GENE M TOR

11 PAGE: 10 OF 22 OUTAGE DATA SET
CURRENT DATE:

06/06/96

]

SELECTION VARIABLES: Percent TIME:

03:40:45 l

l 1 UAM]

l l EXAM EXTENT l l

l l

l l

l l Row lLINI : ATE l HEM #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION lVOLTSIMILlDEGl t lCH lCHNGl

)

1._._ l ____ I I

l_l I

l _I 1

l l

l__ _ L L l_ L._ _ l l 69l 77l04/96l l C lTEC-TEHlTEC-TEHl l00117l580ULlVM+24.78 l 5.82l l174lDNTlP 1l l

l 91l 77l04/96l

-l C lTEC-TEHlTEC-TEHl l00040l580VLl09H- 0.09 l25.38l l179lDNTlP 1l l

l 93l.77l04/96l l C lTEC-TEHlTEC-TEHj l00039l5800Ll09H- 0.15 l33.87l l193lDNTlP lj l

l 95l 77l04/96l l C lTEC-TEHlTEC-TEHl l 00'038 l580ULl Q9H-0.06 l58.60l l175lDNTjP 1l l

l 97l 77l04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+

0.09 l 95.4 8 l l177lDNTlP 1l l

l 99l 77l04/96l l C lTEC-TEHlTEC-TEHl l00030l58buLl09H- 0.21 l29.81l 1177lDNTlP 1l l

l 92l '8l04/96l l C lTEC-TEHlTEC-TEHl l 00040 j 580ULl 0,9H+

0.03

!41.63l l178lDNTlP 1l l

1 94l 78l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H+ 0.00 l39.01l l180lDNTlP 1l l

l 96l 78l04/96l lC lTEC-TEHjTEC-TEHl l00039l580ULjo9H+

0.06 l13.65l l182lDNTlP 1l l

l100l 78l04/96l l C lTEC-TEHjTEC TEHl l00039l580ULl05H+ 15.65 l 7.33l l176lDNTlP 1l l

l l

l04/96l l C lTEC-TEHjTEC-TEHl l00039l580ULl05H+ 16.19 l 9.48l l183lDNTlP*1l l

l l

l04/96l lC lTEC-TEHlTEC-TEHj l00039l580ULl09H-0.03 l33.53l l181lDNTlP lj l

l102l 78l04/96]

lC lTEC-TEHjTEC-TEHl l00038l580ULl09H+

0.06 l26.32]

l181lDNTlP 1l l

132l 78l04/96l lC lTEC-TEHlTEC TEHl l00093l5800Ll10H+ 20.40 l16.97l l173lDNTlP 1]

(

, 91l 79l04/961 lC lTEC-TEHITEC-TEHl l000401580ULj09H+

0.00 l38.451 1179lDNTIP ll l

93l 79l04/96l lC lTEC-TEHlTEC-TEHl l00040l580ULjo9H-0,06 l55.30l l176lDNTlP 1l l

95l 79l04/96l lC lTEC-TEHjTEC-TEHj

}00039l580ULl09H+

0.00 l 70.4 0 l l179lDNTlP 1]

l

.97l 79l04/96l lC lTEC-TEH]TEC-TEHl l00038l580ULl09H-0,12 l93.55l l171]DNTlP 1l l

99] 79l04/96l lC lTEC-TFHlTEC-TEHl l00039l580ULl09H+

0.00 l23.27l l182lDNTlP lj l

I

> 101l 79104 / 9 6 l l - lTEC-TEHITEC-TEHI l00038l580ULl09H-0.27 l24.95l l174lDNTlP 1l l

135l 79104/961 l C lTEC-TEHjTEC-TEHl l00094l580ULjTSC+ 21.39 1 0.08l l184lDNTlP 1l l

l 92l 80l04/96]

lC lTEC-TEHlTEC-TEHj l00040l580ULl09H-0.06 147.55l

{178lDNTlP 1l l

94l 80lC4/96l lC lTEC-TEHlTEC-TEHj l00039l580VLl09H-0.21

]S6.91l l181lDNTlP 1l l

96l 80104/96l j C lTEC-TEHlTEC-TEHl l00039l580ULl09H-0.03 163.18l l179lDNTjP 1l l

!!00l 80l04/96l lC lTEC-TEHlTEC-TEh!

l00039l5EDULl09H.

0.00 l 5.09l l179lDNTlP 1l l

i102] 80l04/96l l C lTEC-TEHlTEC-TEHl l0003Bj580ULl09H.

0.09 l 9.19l l173lDNTlP 1l l

41l 8tl04/961 l C lTEC-TEHlTEC-TEHI l00127l580uLl01C. 19.64 I s.151 l179lDNTlP 11 l

i 851 61l04/96l lC lTEC-TEHITEC-TEH]

l 0012 0 l S e outl 050+ 31. 6 3 l 5.09l 1181lDNTIP 11 l

, 91l 81l04/96l lC lTEC-TEHlTEC-TEHl l00040l580ULl09H+

0.06 125.85l l100lDNTlP 1l l

l l04/96l lC ]TEC-TEHlTEC-TEHl

[00040l580ULl09H+

2,19 l11.20l l172lDNTjP 1l l

' 95l 81l04/96 l l C JTEC TEHlTEC-TEHl l00039l580ULl09H.

0.00 l117.7) l177lDNTjP 1l l

l 971 81l04/961 lC ITEC-TEHITEC-TEHl l00038l580utl09H-0.03 196.93l l171lDNTIP 11 l

i 99l 81l04/96l lC lTEC-TEHlTEC-TEHl l00039l580UL]O9H+

0.00 l60.88) l181lDNTlP 1l l

101l s1l04/96l lC lTEC-TEHlTEC-TEHI l00038l580utl09H-0.15 l24.56l l174lDNTIP 1l l

l 40l 82l04/96l lC lTEC-TEHlTEC-TEHj l00127l580ULlTSC+ 19.03 l 1.11l l178lDNT]P 1l l

4 92l 82l04/96l lC lTEC-TEHlTEC-TEHj l0004nlE80ULl09H-0.12 94.82l l172lDNTlP 1l l

i 94l 82l04/96l lC lTEC-TEHlTEC-TEHl l00039l580ULl09H+

0.00 l84.C5]

l179lDNTlP 1l l

i 96l 82l04/96l lC l TEC-TEH j TEC-TEH l l00039l880ULl09H+

0.00 l157.9l l176lDNTjP ll l

1 98l 82l04/96l lC (TEC-TEHlTEC-TEHl l00038l500ULl09H+

0.06 l101.1l l173lPATlP 1l l

1100l 82l04/96]

lC lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.09 l149.2l l176lDNTlP 1l l

  • 102l 82l04/96l lC lTEC-TEHlTEC-TEH]

l00038l580ULl09H+

0.03 l24.41l l176lDNTlP 1l l

'104l 82]C4/96l l C ITEC-TEHlTEC-TEHl l 0003 9 l 58 0ULlTSH+ 27.4 0 l 5.54l l177lDNTlP 1l l

l l04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+

0.09 l12.62j l182lDNTlP 1l l

l 13 08l 82l04/96l l C lTEC-TEHjTEC-TEHl l00039l580ULl09He 0.09 l75.75l 1179lDNTlP 1l l

j i110l 82l04/96l lC lTEC-TEHlTEC TEHl l00038l500ULl09H+

0.03 l11.60l l177lDNTlP 1]

l lJ l

I _I l

l __ l l

l l

l l_l__l _ I _ l 4

ROCKRIDGE TECHNOLOGIES i

L

~_

~-

+

1 l

CUMULATIVE REPORT l

04/06, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR s 11 PAGE: 11 OF 22 OUTAGE DATA SET CURRENT DATE:

06/06/96 l

SELECTION VARIABLES: Percent TIME:

03:40:45 l

i l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

lROHILINI dan l HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lCEGl % lCH lCHNGl

{

l_I_l l

l_l l

L__ l l

1 I

l_l_l_l l_l t

-l 37l 83104/961 l C lTEC-TEHlTEC-TEHl l00127l500ULivM + 2.96 l 8.061 l174lDNTlP ll l

l l 91l 83l04/96l l C lTEC-TEHjTEC-TEHl l00040l580ULjo9H+

0,06 l31.24l l190lDNTlP1l l

l 95l 83104/96l l C InC-TEHjTEC-TEHl l0gD391580uLlosH+

0.00 170.801 l180lDNTIP11 l

{

} 97l 83l04/96l l C lTEC-TEHlTEC-TEHl l00038l580ULl0pH+

0.00 l184.8l l167lDNTlP 1l l

l 99l 83l04/96l l C lTEC-TEHln C-TEHl -l00039l580utl09H+ 0.00 1108.81 l:50lDNTIP 11 l

l101l 83104/96l l C lTEC-TEHITEC-nHl l00038l58BULl09H- 0.12 l51.72l l173lDNTlP 1l l

l l105l 83104/96l l C lnC-TEHlnC-nHI l00038l580UL]O9H+ 0.09 l23.00l I:78lDNTlP 1l l

l127l 83104/96l lC lTEC-TEHlTEC-TEHl l00093l580ULl06H+ 14,75 l 5.38l l175lDNTlP 1]

l l 40) 84l04/96l l C lTEC-TEHlTEC-TEHl l00126l580ULlVM +

1.97 l 9.72l lD BlDNTlP 1l l

l 94i 84l04/96l lC lTEC-TEHlTEC-TCHl l00130l500ULl09N+

0.00 l27.49l lli2lDNTlP 1l l

l l 96 84104/961 l C lnC-nHlnc-TEHj l00038l580ULl09H+ 0.00 l82.60l l U 9lDNTlP 11 l

l l04/96{

lC lTEC-TEHlTEC-TEHj l00038l580ULlVM + 17.79 l10.89l l176lDNTlP 1l l

l20: 84l04/96l lC lTEC-TEHlTEC-TEHj l00038l580ULl09H+ 0.06 l85.50l l D 3lDNTlP 1l l

l102 84l04/96l l C lTEC-TEHlTEC-TEHj l00130l580ULl09H+ 0.00 l20.18l llillDNTlP1l l

)

l104 84j04/96l l C lTEC-TEHlTEC-TEHl l00038l580%l09H- 0.15 l 6.291 l1 4lDNTlP 1l l

l 1

l106' 84l04/961 l C lTEC-TEHlTEC-TEHj l00038l580ULl09H- 0.18 l44.43l l1'5]DNTIP 1l l

ln: 84l04/96I lC lTEC-TEHlTEC-TEHl l00130l580ULl09H+

0.00 l41.49l l;i2lDNTjP 1l l

l 37 85l04/96!

l C lTEC-nHITEC-TEni 100127l580ULl06C+ 14.16 l 7.46!

1 0lDN-lP 1l l

l l04/96i lC lTEC-TEHlTEC-TEHj l00127l580ULj06C+ 13.20 l 7.13l li'2lDNTlP 1l l

I l 41 85l04/96i l C lTEC TEHlTEC-TEHl l00128l580ULjVM + 2.06 l11.14l l;'7lDNTjP 1l l

l 9: 85l04/961 l C lTEC-TEHlTEC-TEHl l00087l5800Ll09H+ 2.26 l 6.72l liiplDNTlP 1l l

l l04/96!

lC lTEC-TEHjTEC-TEHj l 00087 l 58 0CLl 09C+

0.67 l 8.74l l *

4 l

l l04/96 l C lTEC-TEHjTEC-TEHl l00087l580C]09C- 0.33 l 7.60l l;*3lDNTlP 1l l

j l

l04/96.

l C lTEC-TEHjTEC-TEHl

,jo0087l580ULl08C+

4.78 l 7.27[

l;*4 lDN*lP 1l l

I ln 85l04/96 IC lnC-TEH ITEC-nHI l000881580cl09H-0.29 l62.521 l: 6lDNTlP 11 l

j 95 85l04/96;

[ C lTEC-TEHlTEC-TFHl l00087l580CLl09H+

0.03 l54.19l l1*' 3 l DNT l P l j l

j 97 s5l04/96 l C lTeC.TEHlTEC-Tt o l0008815a0CLj09H+

0.12 l81.59l l1*6lDNTlP 1j l

l l 99 85l04/96-i e inC-TEHITEC-nHj l00087lt:0CLl09H+

0.00 l86.28!

l1 1lDNTlP 11 l

l 1101. 65l04/96l l C lnC-TEHlTEC-TEHl l00088l580CLl09H-0.12 l15.44l l'. 5lDNTjP lj l

l l103 85l04/96i lC lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.06 l27.771

-l; 6lDNTlP 1l l

l h 07 - 65104/96' lC lTEC-nHITEC-nH j l00087l580ULl09H-0.03 l32.67l l: 4lDNTlP 1l l

l109' 85l04/96 lC lTEC-TEHlTEC-TEHj l00088l580ULl09H-0.06 l44.37) l1~6lDNTlP lj l

ins s5{04/96.

l C lnC-TEHlTEC-TEHI l00087l580uLl09H+ 0.17 l 8.96l l: 2lDNTlP il l

l 40 86l04/965 lC lTEC-TEHlTEC-TEHl l00128l580ULlVM +

2.00 l 6.05]

j '. i l l DNT [ P 1 l l

l 84' 86]Q4/96i l C lTEC-TEHlTEC-TEHl l00128l580ULj06C+ 23.08 l 9.16]

l;'9lDNTlP 1l l

l l 92' 86l04/96:

jC lTEC-TEHlTEC-TEHj l00087l580ULjD9H+ 0.06 l$4.93l l1'3lDNTlP 1l l

l 94i 86l04/96f lC lTEC-TCH]TEC-TEHl l00088l580ULl09H+ 0.03 l130.11 l-"3 lDNTl P 1l l

l 96: 86104/96t lC j nC-nH lnC-nHI l00087l580ut109H+

0.03 l78.67l l: 2lDNTIP 1l l

l St 86l04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ '0.00 l70.09) l1'5lDNTlP 1l l

l10: 86:04/96; lC lTEC-TEHl tee-nH I l00087l580ULl09H+

0.00 l37.971 l 74lDNTlP 1l l

l l102. 86lu/96 !

lC InC-TEHlTEC-TEH I l00088l580utl09H-0.09 l27.271 l: 4lDNTlP 1]

l

{104 86l04/96!

lC lTEC TEHlTEC-TEHl l00087l580ULl09H-0.06 l42.63l l1'3lDNTlP 1l l

l10s. 86l0<./96 i lC [nC-TEH ITEC-nHl l00088]580ULl09H+

0.06 156.82l l176]DNTIP 11 l

l108; 86l04/96i lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.00 l51.26l l178lDNTlP 1l l

l11C; 86lO4/96) lC lTEC-TEHlTEC-TEHj l00088l580ULl09H+

0.30 l33.82l l17 9 lDNTl P 1 l l

L _._ _ l l_1 l

l._ l l

l l

L_ L._l _ i _ t _ l ROCFJtIDGE TECENOLOGIES l

I

l j

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS. UNIT 1 l

I STEAM GENERATOR 11 PAGE: 12 OF 22 OUTAGE DATA SET

CURRENT DATE:

06/06/96 l

SELECTION VARIABLESr Percent TIME:

03:40:45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATE] HEAT 8l LEG lPROGRAMl ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L l_l I

l_I I

l_l l

l l

l_I_I_L_L_l l114j 86l04/96l l C lTEC-TEHjTEC-TEHj l00088l580ULl09H+ 0.30 j45.92l l176lDNTlP1l l

l116l 86l04/96l l C jTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.09 l16.23l l175lDNTlP 1l l

l 67l 87l04/96l l C lTEC-TEHlTEC-TEHl l00128l580ULlVM + 23.22 l 5.89l l171lDNTlP 1l

.l l 69) 87l04/96l l C lTEC-TEHlTEC-TEHl l00129l580ULlDH + 7.77 l 7,91l l176lDNTlP 1l l

l 91l 87l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H. 0.03 l66.38l l172lDNTlP 1l l

l'93l 87l04/96l l C lTEC-TEHjTEC-TEHj l00088l5800Lj09H+ 0.03 l122.7l -l175lDNTlP lj l

l 95l 87l04/96l l C lTEC-TEHjTEC-TEHj l00087l580ULl09H+ 0.03 l128.9l l170lDNTlP lj l

l 97l 87l04/96l l C lTEC-TEHlTEC-TEHl l00088j5800Ll09H+ 0.12 l118.0l l175lDNTlP 1l l

l 99l 87l04/96l lC lTEC-TEHlTEC-TEHl l00087l500ULl09H+ 0.12 l118,0l l172lDNTlP 1l l

l l103] 87l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.00 l57.38l l173lDNTjP 1l l

l105l 87l04/96l l C lTEC-TEHlTEC-TEHl l00088l5800Ll09H.

0,12 l108.5l l176lDNTlP 1l l

l107l 87]C4/96l l C lTEC-TEHjTEC-TEHj l00087l580VLl09H-0.18 l13.19l l171lDNTlP lj l

l109l 87104/96l l C lTEC-TEHlTEC-TEHf l00088l5800Ll09H+

0.03 l21.32l l177lDNTlP 1l l

l 40l 88104/96l l C lTEC-TEHlTEC-TEHj l00128l580VLlVM +

1.85 l 9.36l l177lDNTlP 1l l

l 92l 88!04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.03 l37.63l l173lDNTlP 1l l

l 94l 86IC4/96]

l C lTEC TEHlTEC-TEHl l00087l580ULl09H-0.03 l128.0l l110lDNTlP 1l l

l 96l 88;04/96l l C lTEC-TEHlTEC-TEH!

l00088l580ULl09H- 0.03 l129.8) jl74lDNTlP 1l l

l 98l 88 04/96l l C lTEC-TEHlTEC-TEC lC0087l580 ult 09H+

0.06 l53.58l l175lDNTlP 1]

l j100l 66 LO4/96l l C j'IEC-TEHlTEC-TEH1 i00088l580ULlD9H+

0.12 l50.24l l178lDNTlP 1l l

l114l 88l04/96l l C lTEC-TEHlTEC-TEHl

%D088l580ULjo9H-0.03 l59.79l l175lDNTlP 1l l-l l118l 96604/96l l C lTEC-TEHjTEC-TEH1 300088l580ULl10H+

0.C0 l 9.61l l181lDNTlP 1l l

l j 91l 89!04/96l l C lTEC-TEHlTEC-TEH]

l00087l580ULj09H+ 0.00 l46.40l l179lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC TEH!

l00087l580ULl09C+ 1.96 l14.62l l168lDNTlP 1l l

j 93l 89}04/96]

l C lTEC-TEHlTEC-TEHl l00088l500ULl09H-0.03 l95.65j l174lDNTlP 1l l

l 95l 89'04/96l l C lTEC-TEHlTEC-TEHl lC0087l580UL]O9H+

0.00 l84.09l l171lDNTlP 1l

}

f l 97l 89104/96l l C lTEC-TEHlTEC-TEH!

l00088l580ULl09H+

0,00 l91,57]

l175lDNTlP 1l l

l101l 89'04/96l l C lTEC-TEHjTEC-TEHj l00088l580ULl09H+

0.18 l18.68l l176lDNTlP 1l l

l103l 89;04/96l l C [TEC-TEHlTEC-TEHl l00087l5800Ll09H+

0.15 l 6.10l l176lDNTjP 1l l

1105l eir,04/96 l l C lTEC-TEHlTEC-TEH j l00088l580ULl09H+

0.00 l10.39l l182lDNTlP 1l l

j l209l 69l04/96l lC [TEC-TEHjTEC-TEHj l00088l580ULl09H+

0.27 l11.85l l175lDNTlP 1l l

l113l 89l04/96l l C lTEC-TEH]TEC-TEHj lCD088l580ULl09H-0.21 l14.11l l174lDNTlP 1l l ~

l119l 89l04/96l l C lTEC-TEHlTEC-TEH]

l 0 0087 l $80UL] C 9H + 0.03 l24.64l l173lDNTlP 1l j

i l127) 89]04/96l l C lTEC-TEHjTEC-TEHj l00087l580ULl10C-2.05 l 5.07l l177]DNTlP 1l l

l l

j04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09C+ 19.78 l $.79]

l175lDNTlP 1l l

l 92l 90l04/96l l C lTEC-TCHlTEC-TEHl l00087l580ULl09H-0.03 l39.98l l171lDNTlP 1l l

l 94l 90104/96l

} C lTEC-TEHlTEC-TEHl l00088l500ULl09H+ 0.12 l30.80l l175lDNTlP 1l l

l 96l 90104/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09He 0.00 l63.73l l178lDNTlP 1l l

l 98l 90l04/96l l C lTEC-TEHlTEC-TEHl l00088]580ULl09H+

0.00 l12.13l l182lDNTlP 1l l

l100l 90104/96l l C lTEC-TEHlTEC-TEHl l00100l5800Ll09H+ 0.00 l29.00l l181lDNTlP 1l l

l l

104/96l l C lTEC-TEHjTEC-TSHl l00087l580ULl09H+

0.03 l27.74l l173lDNTlP 1l l

l102] 90l04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.21 l19.19l l173lDNTlP 1]

l l110l 90l04/96l l C lTEC TEHlTEC-TEH) l00088l580ULl09H+

0.15 l18.23]

l177lDNTlP 1l l

l114l 90l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.18 l17.03l l175lDNTlP 1l l

l 91l 91l04/96]

l C lTEC-TEH[TEC-TEHl l00087l5800Ll09H+

0.00 l42.09l l178lDNTjP 1l l

l l 93l,91104/96l l C lTEC-TEHlTEC-TEHl l00088l5BOULl09H+ 0.27 l49.99l l175lDNTlP 1l l

l _ l -__ '

l l_l l

L_I I

I L

l __ L__ l __ L._ I _ I l

ROCKRIDGE TECHNOLOGIES l

l l

.~

__m i

CUMUIATIVE REPORT 04/96, DGE, CQLVERT CLIFFS, UNIT 1 1

STEAM GENERATOR 11 PAGE: 13 OF 22 OUTA3I DATA SFT i CURRENT DATE:

06/06/96 SELECION VARIABLES: Percent TIME:

03:40 45

)

1 i

I l

l EXAM!

l l EXAM EXTENT l l

l l

l l

j l ROW *INl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L

m _l l_!

I l __ l l

I I

L_ l_l _._ L _I _ l l 95! nl04/961 l C lTEC-TEHITEC-TEHI l000871580utl09H-0.03 l21.36l l17slDNTIP 11 l

i l 97, 31l04/96l l C lTEC-TEHlTEC-TEH]

l00088l580ULl09H+

0.21 l48.31l l174lDNTlP 1l l

l 99: 91l04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+

0.09 l42.50l 1175lDNTlP 1l l

l103 51l04/96; l C lTEC-TEHlTEC-TEHl l 00087 l 5800Ll 0,9H+

0.00 l10.82l l178lDNTlP lj l

l109 P1l04/96i l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.12 l20.97l l176lDNTlP 1l l

j l60, 12l04/961 l C lTEC-TEHlTEC-TEHl l00072l58hULlTSC+

7.18 l 8.80l l182lDIUlP1l l

l 92 32l04/96l lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.06 l108.2l l168lDNTjP 1l l

l 94 32l04/96i l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l55.49l l175lDNTlP 1l l

I l 96 12l04/96' l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.09 l60.05l l172lDNTlP 1l l

l 96 32l04/96' l C ITEC-TEHlTEC-TEHl l00088l580ULl09H+

0.15 l31.81l l175lDNTlP 1l l

f l10c 32104/96 lC ITEC-TEHITEC-TEHl l 00087 l 580UL] O9H+

0.09 l42.25]

!174lDNTlP 1]

l l

l106 12l04/96 l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.15 l49.15l l176lDNTlP 1l l

l11C 12l04/96 lC '~EC-TEHlTEC-TEHj l00088l580ULl09H+

0.21 l 24'. 37 l

!176lDNT]P 1l l

l l12i 32l04/96 l C 'TEC-TEHlTEC-TEHl l00088l580ULlTSC+ 22.07 l 5.68l

!176lDNTlP 1l l

{

l 91 13l04/96 lC ;TEC-TEHjTEC-TEHl l00087l580ULl09H+ 0.00 l31.56l 174lDNTlP 1l l

l 93 13l04/96 lC !!EC-TEHlTEC-TEHl l00088l580ULl09H-0.03 l46.12l 8175lDNTlP 1l l

lH Hj04/96 lC iTEC-TEHlTEC-TEHj l00087l580ULl09H+

0.03 l56.33l

'173lDNTlP1l l

l 97 H]04/S6 lC '!EC-TEHlTEC-TEHl l00088l5800Ll09H+

0.09 l35.64) 176lD!UlP 1l l

l 9? !)l04/96 lC '!EC-TEHjTEC-TEHl l00087l580ULl09H-0.15 l14.72l

171lDNTlP 1l l

l1C) i3l04/96 l C j'EC-TEHlTEC-TEHj l00087l500ULl09H-0.29 l d.03l

'178lDNTlP 1l l'

j l

l1C7 13104/96 lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.09 l30.82l 174lDNTlP 1l l

]

l (10 ir Hl04/96 lC iTEC-TEHjTEC-TEHl l00068l580ULl09H+- 0.21 l33.05l 175lDNTlP 1l l

(

l 94 i4jo4/96 lC TEC-TEHlTEC-TEHl l00088l580ULl09H.

0.15 l16.05l 176lDNTlP 1l l

l 9s ul04/96 lC iTEC-TEHITEC-TEHI l00097l580ULl09H+

0.03 l58.10l 173lDNTjP 1l l

l1c2 nl04/96 lC lTEC-TEHlTEC-TEHl l00088l5BOULl09H+

0.12 115.06l 176lDNTlP 1l l

{

l104 74l04/96 lC TEC-TEHlTEC-TEHj l00087l580ULl09H+

0.00 l43.91]

175lDNTlP 1]

l l10f 14l04/96 lC 1TEC-TEHlTEC-TEHl l00088l580ULl09H+

0.09 l73.51l 175lDNTlP 1l l

l106 ~4104/96 lC !EC-TEHlTEC-TEHl l00007l580ULl09H+

0.03 l39.02l 174lDNTlP 1l l

lu: +4104/96 l C iTEC-TEHlTEC-TEHl l00088[580ULl09H-0.12 l18.19l 176lDNTlP 1l l

l l04/96 i C 'TEC TEHlTEC-TEH]

l0008el580ULl01C+ 33.82 l 9.701 173lDNTIP 1l l

l116 14{04/96 l C J TEC-TEHlTEC-TEHl l00088l5800Ll10H-0.06 l65.85l 175lDNTlP 1l l

j l12s +4104/96 lC lTEC-TEHlTEC-TEHj l00089l580ULlTSC+ 22.93 l 6.00l 171lDNTlP 1l l

l 91 15l04/96 lC [TEC-TEHlTEC-TEHj l00087l580ULl09H-0.03 l27.18l

.172lDNTlP 1l l

l 93 15l04/96 lC l'"EC-TEHlTEC-TEHj l00088l580ULl09H+

0.03 l97.89l l175lDNTlP 1l l

l 95 35l04/96 l C lTEC-TEHjTEC-TEHl l00087l580ULl09H-0.06 l39.79l 173lDNTlP 1l l

l 97 15104/96 lC iTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l101.41

'173lDNTlP 1l l

l 99 35l04/96 lC iTEC-TEHITEC-TEHI l00087l580ULl09H+

0.00 l62.42l

<178lDNTlP 1l l

l l

l04/96 lC lTEC-TEHjTEC-TEHl l00087l580ULl09C-0.21 l 5.86]

1179lDNTlP 1l l

f l101 55l04/96 lC [TEC-TEHlTEC-TEHj l00088l580ULl09H+

0.15 l34.98l

'175lDNTlP 1l l

j' l103 nl04/96 l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+

0.00 l62.04l 172lDNTjP 1l l

l l107 15l04/96' lC lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.03 l31.30l l171lDNTlP 1l l

l l109 35104/96 lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+- 0.09 l14.17]

!173lDNTlP 1l l

l117 15l04/96 lC lTEC-TEH]TEC-TEHl l00088l580ULl10H+

0.00 l84.17l il73lDNTlP1l l

l119 15l04/96 lC l'EC-TEHlTEC-TEHl l00087l580ULl10H+

0.00 l 9.48l

?175lDNTlP 1l l

l 92 16104/96 lC lTEC-TEHlTEC-TEHl l00087l5800Ljo9H-0.06 l24.53l

!173]DNTlP 1l l

l __ _ 1 L!

I l_I I

l-I l _ -_ L__I _ l _ I ROCERIDGE TECHNOLOGIES a

i

CUMULATIVE REPORT 04/9% BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 14 OF 22 OtTTAGE CATA SET t CURREN7.

DATE:

06/06/96 SELECT"N VARIABLES; Percent.

TIME:

03i40t45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l ROW l1 *N[ DATEl HEAT 8 l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl I

l_ L._ I I

L_I I

l._. l l-I L L L_L._L l

l 94) Ef104/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 l55.49l l182lDNTlP 1l l

l 96l 9(l04/96l l C lTEC-TEHlTEC-TEHj l00087l5800Ll09H+

0.09 l88.42l l170lDNTlF 1l l

l100l ifl04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULjo9H-0.06 l 5.33l l173lDNTlF 1l l

T l108) if104/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl0$H+ 0.00 l47.54l l174lDNTlF 1l l

l110l Si!04/96l l C lTEC-TEHlTEC-TEHj l00088l5800Ll09H+ 0.06 l24.14l l176lDNTlF 1l l

j118l ifl04/96l l C lTEC-TEHjTEC-TEHl l00088j580hl10H+ 0.00 l* 9.20 l l181lDNTlF 1l l

1 l128l 16104/96l

[ C lTEC-TEHlTEC-TEHl l00089l580UL]O9,H+

0.23 l 5.09l l180lDNTlF 1l l

{

l 47l i :04/96l l C lTEC-TEHlTEC-TEHl l00072l5800Ll04H+ 6.29

) 5.85l l178lDNTlF 1l l

I

'l 91 l P ~' ' 0 4 / 9 6 l l C lTEC-TEHlTEC-TEHl l00087l500ULl09H+ 0.03 l31.82l l176lDNTlF 1l l

4 l

l 04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09G+ 2.12 l12.35l l169lDNTlF 1l l

7 l 93l 37'04/96l l C lTEC-TEHlTEC-TEHl l00088j580ULl09H-0.06 l94.63l l174lDNTlF fl.

l l 95 l 3"'. 04/96 l l C lT4C-TEHlTEC-TEHj l00087l580ULj09H+ 0.03 l82.41l l174lDNTjF 1l l

l 97l l' 04/96l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.06 l142.1l l172lDNTlF 1l l

l 99l i~ 04/96l ClTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.00 l66.01l l176lDNTlT 1l l

l105l i~ 04/96l C lTEC-TEHlTEC-TEHl l00088l580ULl02C+ 17.85 l 5.58l l171lDNTlF 1l l

l l

04/96l C lTEC-TEHlTEC-TEHl l00088l5800Ll02C+

6.41 l 5.18l l171lDNTlF 1]

l l107l i~ 04/96l C lTEC-TEHlTEC-TEHl l00087l580ULl09H.

0.03 l 5.67l l174lDNTl7 1l l

l109l l' 04/96l C lTEC-TEHlTEC-TEHj l00088l580ULl09H-0.06

{63.58l l174lDNTl7 1l l

I l 92l 11 04/96l C lTEC-TEHlTEC-TEHj l00076l580ULl09H-0.09 l30.61l l176lDNTlF 1l l

l l

04/96l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.03 l32.98]

l174lDNTlF 1l l

s l 94l e 04/96l C lTEC-TEHlTEC-TEHj l00088l5800Ll09 l 94l 98l04/96l l C lTEC-TEHlTEC TE1l l00088l5800Ll09 l 96l c 04/96l C JTEC-TEHjTEC-TEHl l00087l580ULl09H-0.12 l108.3l l169lDNTlF 1l

{

i j 98l 16 04/96l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l78.68l l181lDNTlF 1l l

l100) Si 04/96l C lTEC-TEH!TEC-TEHl jo0007l580ULl09H+

0.00 l11.52l l173lDNTlF 1l l

{

l102) si 04/96' C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.03 l27.81l l176lDNTlF 1l l

l110l it 04/96l lTEC-TEHlTEC-TEHj l00088l580ULl09H+

0.15 l21.27l l175lDNTlP 1l l

l 69l Ji 04/96l C lTEC-TEHlTEC-TEHl l00071l580ULlVM + 24.86 l 6.39l l180lDNTl7 1l l

l 91l ' 04/96l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.03 l41.80l l176lDNTjF 1l l

)

l l

04/96[

C lTEC-TEHlTEC-TEHl l00087l5800Ll09H+

1.94 l 7.86l l168lDNTjF 1l l

l l 93l if 04/96]

C lTEC-TEHlTEC-TEHj l00088l580ULl09H+

0.00 l62.25l l181lDNTlF 1l l

l 95l 31 04/96)

C lTEC-TEHlTEC-TEHl l00087l580ULl09M+

0.06 l22.28l l173lDNTlF 1l l

l 97l if 04/96l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l74.53l l181lDNTlF 1l l

l 99l 37 04/96l

. C lTEC-TEHlTEC-TEHl l00087l580ULl09H- 0.12 l98.71l l173lDNTlF 1l l

[101l ii 04/96l C lTEC-TEHlTEC-TEHl jo0088l5800Ll09H+

0.03 l34.41l l176lDNTlF 1l l

l105l 11 04/96l i C lTEC-TEHlTEC-TEHl l00088l580HLl09H+

0.00 l28.30l l176lDNTlP 1l l

l107l ii 04/96l C lTEC-TEHlTEC-TEHl l00087j580ULl09H+ 0.06 l26.54l l173lDNTlF 1l l

4 l117l H 04/96l C lTEC-TEHlTEC-TEHl jo0088]5800Ll10H+

0.00 l25.61l l182lDNTlF 1l l

l119l il 04/96l

! C lTEC-TEHlTEC-TEHj l00087l580ULl10H+ 0.12 l 6.08l l173lDNTlF 1l l

l121l 13 04/96l C lTEC-TEHlTEC-TEHj l00088l580ULl10H+ 0.00 l 5.97l l100lDNTlF 1l l

l 50l11' 04/96l C lTEC-TEHlTEC-TEHj l00071l580ULlVM - 2.00 l 5.35l l179lDNTlT 1l l

l92lC 04/96l C lTEC-TEHlTEC-TEHj l00087l580ULl09H-0.06 l17.09l l173lDNTlF 1l l

l 94l10 04/96l C lTEC-TEHlTEC-TEHj l00088l580ULj09H+ 0.00

{14.88l l182lDNTlF 1l l

l 96l1: 04/96l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+

0.06 l55.73l l174lDNTlF 1l l

l100l1' 04/96l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l76.79l l180lDNTlP lj l

l102l1:* 04/96l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l82.99}

l181lDNTjF 1l l

l __ L_

l

'__l 1

L_ I I

I l-L_I_ L_L l_l ROCERIDGE TECHNOLOGIES

I l

CUMULATIVE REPORT

)

00/96, BGE, CALVERT CLIFFS, UNIT ;

STEAM GENERATOR 11

'FAGE:

15 OF 22 OtfrAGE DATA SET CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 l

l l EXAMj l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCAT::N l V;" TS I M:". j DEG l % lCH lCHNGl l_l_l l

l_1 I

l.-._ I l

l 1

L _J _ l_I _ !_._ i l104l100l04/96l l C lTEC-TEHlTEC-TEHj l 00087 l 58 0ULl : 9H e 0.00 l17.62l l176lDNTlP 1l l

11081100104/96l l C lTEC-TEHITEC-TEHi l 000871580uti: 9H+

0.00 137.50l l181lDNTlP 1l l

l118l100l04/96l l C lTEC-TEHlTEC-TEHl l 00068 l 58 0ULl;0H+

0.00 l21.97l l181lDNTlP 1l l

l 37l14l04/961 l C lTEC-TEHlTEC-TEHj l0dO69l580ULll6H+ 16.76 l 7.98l l180lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHj l 00069 l 580ULl:7H-1.20 l3C.14l l178lDNTlP 1l l

l l

l l04/96l

[ C lTEC-TEHlTEC TEHj l00069l58tULl:H + 13.96 l39.98l l177lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00069l580ULl*.N -

0.73 j24.85l jl?7lDNTlP 1l l

l l

l l04/96l l C lTEC-TEHjTEC-TEHl l00069l580VLl:6C+ 22.90 l 1.47]

l181lDNTlP 1l l

l 39l101l04/96l l C lTEC-TEHjTEC-TEHl l 00068 l 5 8 0ULl :7H+

0.27 l 6.16l l176lDNTlP 1l l

7 l

l 104/96l l C lv w T HITEC-TEHI l00068 l580ULj:6c+ 19.37 l 5.51l l174lDNTIP 1l l

l 69]i01i04/96l

! C lTEC-TEHlTEC-TEHI l0007115800L1.N + 24.38 l 6.37l l180lDNTlP 1l l

l 91l101l04/96l

]C lTEC-TEHlTEC-TEHl l D008 7 l 58 0ULl :iH*

3.00 l17 36l 1175lDNTlP 1l l

l 93l101l04/96l l C lTEC-TEHlTEC-TEHl l 00088 l 58 0ULl : 9H+

0.00 l76.78l 1176lDNTlP 1l l

1 l 95l101104/96l l C lTEC-TEHjTEC-TEHl l 00087 l 5 8 0ULI : iH+

0.00 l6E.32l l171lDNTlP 1l l

l 97l101iO4/96l lC lTEC-TEHlTEC-TEHl l 00088 l 5 8 0UL I : 7H +

0.0C 153.12l jl80lDNTlP 1]

l l 99l101iO4/96) l C lTEC-TEHlTEC-TEHl l 00087158 0ULl ;iH-0.24 l1'3.1l 1171] UTlP 1l l

1101l101'04/96l l C lTEC-TEHITEC-TEHI l 00088 l S e 0UL! :iH+

.00 189.:7l 1175lDNTlP 1l l

l103l101;04/96l l C lTEC-TEHlTEC-TEHl l 00087 l 5 9 0UL I : iH-2.16 l8:,92l

!172lDNTlP 1l l

l105l101]C4/96l l C lTEC-TEHjTEC-TEHj l 00088 l 5 8 0UL l :iH+ ;. 0 0 134 :4l 182lDilTlP 1l l

l l107l101104/96l l C lTEC-TEHjTEC-TEHI l 0008715 8 0UL I : 3H+

.00 l57.93l l178lDNTlP 1l l

l109l301104/961 lC lTEC-TEHlTEC-TEHj l 0008 8 ] 5 8 0ULl

  • iH+ 15. 34 l (.79l

[170lDNTlP 1l l

1117l101!O4/96l lC lTEC-TEHlTEC-TEHl l 00088 l 5 8 0UL ' 5C+ 15.46 l i.421 172lDNTlP 1l l

l121l1ct 04/96l l C lTEC.TEHlTEC-TEHl l 0008815 8 0UL i : < H+ 15.10 l !.e31 176lDNTIP 11 l

l l

'04/96l j C lTEC-TEHlTEC-TEHl l 0008 8 l 5 6 0ULI iH+ 1$.6E l 9.63l

176lDNTlP 1l l

l l

04/96l lC lTEC-TEHITEC-TEHl l00088ls u UL;_ H+
.0c I n. 621 182lDNTlP 1l l

1121l10t:04/96l lC lTEC-TEHlTEC-TEHl l 00 091 l 5 8 0UL G ' H-0.06 l (.54l l181lDNTlP 1l l

1133l101 04/96l l C ITEC-TEHITEC-TEHl l00092l$e0Uu:H + :s 25 l1" 40]

176lDNTlP 1l l

f 70l102:04/96l l C lTEC-TEHITEC-TEH6 l 00071l S e :uL ash. 24.23 11: 641

179lDNTIP 11 l

l 92l102iO4/96l l C lTEC-TEHlTEC-TEHl l00087l59 **L!

iH+

.00 136 6l l179lDNTlP 1l l

l 94l102l04/96l l C lTEC-TEHlTEC-TEHl l 0008 8 ] 5 8 0UL I : :-H+

0.06 16e ' ' '

'1'4lDWlP 1l l

l 96l102104/96l l C lTEC-TEHlTEC-TEHj l 0006715 8 0ULl : iH+

0.00 l49.10l 178lDNTlP 1l l

l 98l102:04/96l l C lTEC-TEH]TEC-TEHl l D008 815 9 0UL: :iH+

0.00 lH.78l

~81lDNTlP 1l l

l100l102104/96l l C lTEC-TEHlTEC-TEHj l 0008 7 l 5 8 0ut! : 3H.

.06 l7:.asl il?1lDNTlP 1l l

1102l102l04/96l l C lTEC-TrHITEC-TEHj l00088158 cull:3H+

0.00 l113.01 il74lDNTlP 1l l

l106l102lC4/96l lC lTEC-TEHlTEC-TEHl l 00087 l 5 8 0UL l:iH+

0.00 l4(.57l (174lDNTlP 1l l

l122l102iO4/96l l C lTEC-TEHlTEC-TEHl l00088 l 5 8 0ULl

  • H+

0.00 l13.79l (180!DNTlP 1l l

l 21l103iO4/96l l C lTEC-TEHlTEC-TEHl l 0006 9 l 5 8 0ULl'.N +

0.52

] !.36l il74lDNTlP 1l l

l 91l103iO4/96l l C lTEC-TEHjTEC-TEHl l 00086 l 58 0ULl : 9H+

0.00 l43.07l 1181lDNTIP 1l l

l 93l103104/96l l C lTEC-TEHITEC-TEHI l 000e 5 l 5 8 0UL l: aH.

.12 173.:91 1175lDNTlP 2l l

l 95l103l04/96l l C lTEC-TEHjTEC-TEHl l 00086 l 58 00Ll: 7H+

0.00 l21.59]

l179lDNTlP 1l l

l 97l103l04/96l l C lTEC-TEHlTEC-TEH]

l00085l580ULl iH+

0.54 l61.59) 1175lDNTlP 1l l

l 99l103l04/96l l C lTEC-TEHlTEC-TEHl l 00086 l 5 8 0ULl :iH+

0.21 l12.08l 1180lDNTlP 1l l

1101l103iO4/96l l C lTEC-TEHlTEC-TEHj l 00085 l 5 6 0ULl : 3H+

0.06 l103.9l l174lDNTlP 1l l

i l103l103104/96l l C lTEC-TEHlTEC-TEHl l 00086 l 58 0ULl;iH+

0.00 l32.93]

l181lDNTlP l

l105l103l04/96l l C lTEC-TEHlTEC-TEHf l00085l5800Ll:&H+

0.09

{59.21l l178lDNTlP l

L._1 I

l_1 l

LI 1

l l- _'__ L_l___1 _ t ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, DCE, C EVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE 16 OF 22 OUTAGE DATA SET t CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

lRDWlLINl DATEl HEAT #l LEG l PROGRAM l ACTUALjEXPl CAL l PROBE]

LOCATION l VOLTS l MIL]DEGl % lCH lCHNGl I_L I i

1._

l l

Ll l

l

!. _ l_ _ l _ L _l l

l107l103l04/96l l C lTEC-TEHlTSC-TEHl l00086l5800Ll09H+

0.00 l34.98l l177lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00100l580ULl09H+ 0.00 j35.53l l180lDNTlP 1l l

l 92l104l04/96l l C lTEC-TEHlTEC-TEHl l 00086 l580ULl 09H+ 0.00 l50.26l jl60lDNTlP 1l l

l 94l104l04/96l l C lTEC-TEHlTEC-TEHl l0dO85l580ULl09H+ 0.06 l110.0j l173lDNTlP 1l l

l 96l104l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l81.41l l181lDNTlP1l l

l 98l104l04/96l l C lTEC-TEHlTEC-TEHj l00085l5 foul l09H- 0.03 l59.93l l176lDNTlP 1]

l l102l104l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H- 0.12 l 5.76l l176lDNTlP 1l

[

l106l1C4l04/26l l C lTEC-TEHlTEC-TEHj l00085l580ULld9H+ 0.06 l61.45l l175lDNTlP 1l l

l124l1:4l04/96l lC lTEC-TEHlTEC-TEHj l00092l5800Ll10H-0.15 l 5.12l l178lDNTlP 1l l

l l 91l1:5l04/96l l C lTEC-TEHlTEC-TEHl l 0 0086 l 58 00L l 09,H+

0.00 l59.82l l181lDNTjP 1l l

l 93l1:5104/96l l C lTEC-TEHITEC-TEHI ic0085l580ULl09H+

0.18 l 74. 04 l l175lDNTlP*1l l

l 95l105l04/96l l C lTEC-TEHITEC-TEHI l:00861580uLl09H+ 0.00 144.43l l181lDNTlP lj l

l 97l1c5l04/96l l C lTEC-TEHITEC.TEHI l:0085l580utl09H+

0.03 11:5.61 l174lDNTIP 1l l

J 4

j l 99l1:5l04/96l l C lTEC-TEHlTEC-TEHl l 0086l580ULl09H+

0.00 l21.49l l193lDNTlP 1l l

l101l1:5l04/96l lC lTEC-TEHlTEC-TEHl

.00085l580ULl09H+

3.00 115.63l l178lDNTlP 1l l

l111l1csl04/961 l C lTEC-TEHlTEC-TEHl i:0086l580ULlvC +

1.53 11:.92l l175lDNTlP 1l l

l117l1:sl04/96l l C lTEC-TEHITEC-TEPl

3085l58cULl10H-3.03 l1'.12l l175lDNTIP ll l

l l

l04/96l l C lTEC-TEHlTEC-TEHl 0085l5BOULl10b 3.06 l f.32l l178lDNTlP 1l l

l119l105j04/96l l C lTEC-TEHlTEC-TEHj

3086l580%l10H+

3.15 l::.56l l161lDNTlP 1l l

l121l1:5l04/96l l C lTEC-TEHlTEC-TEHl

!!D005l580ULl10H+

0.09 l20.92l l179lDNTlP 1l l

l123l1:3104/96l lC lTEC-TEHlTEC-TEHl

3091l580U*l10H+

3.00 l 1.95l l183lDNTlP 1l l

l 92l1:6l04/96l l C lTEC-TeHITEC-TEHI

30861580cl09H+

3.00 l4:.14l l180lDNTIP 1l l

l 94l106l04/96l l C lTEC-TEHlTEC-TEHl 20085l580Cl09H+

0.09 l97.72l l174lDNTlP 1l l

j l 96l1:6l04/96l l C lTEC-TEHjTEC-TEHj 3086l580ULl09H+

0.00 l35.66l l182lDNTlP 1l l

l 98l10i104/96l lC lTEC-TEHlTEC TEHj 3085l580ULl09H+

3.00 l24.30l l179lDNTlP 1l l

)

l120l1:fl04/96l lC lTEC-TEHlTEC-TEHl

, 0 008 6 l 5 8 0% l10H+

3.00 jl5.65l l183lDNTlP 1l l

l l

l04/96l lC lTEC-TEHjTEC-TEHI 0086 l58 CULL 09C+ ;3.77 l 9.28l jl60lDNTlP 1l l

l122l1:fl04/96) l C lTEC-TEHlTEC-TEHl

~:0851580ULl10H.

0.09 l35.06l l178lDNTlP 1l l

l 91l1:Tl04/961 lC lTEC-TEHITEC.TEsl 2 086 l 5 8 u. 10 9H+

0.0c le7.481 11e1lDNTIP li l

l 93l1:7l04/961 l C lTEC-TEHITEC-TEHI i :085l580c!09H-3,0E lI!2.0l l174lDNTlP 1l l

l 95l107l04/96l l C lTEC-TEHlTEC-TEHl 20086l580ULl09H+

3.00 l6-62l l181lDNTlP lj l

l 97l1:7l04/96l l C lTEC-TEHlTEC-TEHl

0085l580C]09H-3.09 l55.39) l176lDNTlP 1l l

l l

l04/96l l C lTEC-TEHITEC TEHi i:0085l580ULl08C+ 15.36 l e.53l l175lDNTlP 1l l

l 99l107l04/96l l C lTEC-TEHlTEC-TEHl 3:0086]580ULl05H+

3.00 l31.35l l181lDNTlP 1l l

l103l1:7l04/96l lC lTEC-TEHjTEC-TEHI f 0086l580ULl09H+ o.00 169.70l l181lDNTlP ll l

4 4

l107l1H04/96l l C lTEC-TEHITEC TEHI 1:0086l580ULl09H+ 0.00 l11.02l jl80lDNTlP 1l l

l123l1:7l04/961 l C lTEC-TEHjTEC-TEHj i:00911580ULl10H+

0.15 l17.24l l182lDNTlP 1l l

l133l1:7l04/96l l C lTEC-TEHlTEC-TEHj J:0092l500ULl09H+

0.21

) 6.12l l179lDNTlP 1l l

l 94l1:e104/96l lC lTEC-TEHITEC-TEHI 1:0085l580cl09H.

3.27 l45 i8l l175lDNTIP 11 l

j l 96l1:6l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l1:4.9l l179lDNTlP 1l l

l 9811:5l04/96) lC lTEC-TEHlTEC-TEHl 00085l580ULl09H+

0.03 l60.86l l176lDNTlP 1l l

l100ll:Bl04/96l lC lTEC-TEHlTEC-TEMl

! 0086l580ULl09H+

0.00 l32.89l l182lDNTlP 1l l

l102l106l04/96l lC lTEC-TEHjTEC TEHl i:0085l580ULl09H+

3.00 l4 48l l175lDNTlP 1l l

l104l1:fl04/96l lC lTEC-TEHjTEC-TEHl l:0086l580ULl09H+

3.00 l25.96l l181lDNTlP 1l l

l20611:sl04/96l l C lTEC-TEHITEC TEHI l:0085l5800Ll09H-0.06 l25.10l l175lDNTlP 1l l

l_l_l 1

1 _l 1

l ___ !

I I

I L.__I__.l_ I_ _l _ I i

ROCKRIDGE TECHNOLOGIE3

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 t

l j

STEAM GENERATOR s 11 PAGE: 17 OF 22 OUTAGE DATA SET

CURPENT DATE:

06/06/96 SELECTION t*ARIABLES: Percent TIME:

03:40:45 l

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl CATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE lLOCATION l VOLTS l MIL l DELL % lCH lCID4Gl l

1._ _l _ I I

l____l l

1.__ l l

l 1

l_I_l_ L _l_l l106l108l04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULjo9H+ 0.00 l17.29l l182lDNTlP 1l l

l l118l108l04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl10H-0.06 l38.57l l174lDNTlP 1l l

l 69l109l04/96l l C lTEC-TEHlTEC-TEHj l00068l580ULlVM + 25.14 l 8.19l l172lDNTlP 1l l

l 91l109l04/96l l C lTEC-TEHlTEC-TEHl l 00'08 6 l 58 0ULl 0,9H+ 0.00 l24.90l l182lDNTlP 1l l

l 93l109l04/96l l C lTEC-TEHlTEC-TEHl l00085l580UL]09H+ 0.09 l46.75l l175lDNTlP 1l l

l 95l109l04/96l l C lTEC-TEHlTEC-TEHj l00086l58tULl09H+

0.00 l32.87l l182lDNTlP 1l l

l 97]IO9l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H- 0.12 l86.08l l172lDNTlP 1l l

l 99l109l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l30.33l l182j0NTlP 1l

}

l101l109l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l29.00) l176lDNTlP 1l l

l103l109l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l64.38l l181lONTlP lj l

l119l109l04/96l lC lTEC-TEHlTEC-TEHl jo0086l580ULl10H+

0.00 l12.07l l181lCNTlP*3l l

l121l109l04/96l l C lTEC-TEHjTEC-TEHl l00085l580ULl10H+

0.06 l24.17l l175lONTlP 1l

.l l 92l110j04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+

0.00 l19.16l 1180l0NTlP 1l l

l 94 l110 l 04 /96 l lC lTEC-TEHlTEC-TEHi l00085l5800Ll09H+

0.00 l31.41l l17610NTlP 1l l

l 96l110l04/96j l C lTEC-TEHlTEC-TEH1 l00086l580ULl09H+ 0.00 l14.23l l181l0NTlP 1l l

l 98 l110 l 04 /96 l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H+

0.06 l18.34l 1178lDNTlP 1]

l l106l110l04/96l lC lTEC-TEHlTEC-TEHl l00085j580ULl09H+

0.00 l14.94l l174f0NTlP 1l l

i *.2 0 l110 l 04 / 96 l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+

6.41 l 5.13l il78l:NTlP 1l l

l l04/96l l C lTEC-TEHlTEC-TEHi l00086l580ULl09H+

7.28 j 5.07l l178 pNTlP 1l l

j l04/96l l C lTEC-TEHlTEC-TEH1 l00086l580ULl09H+ 9.25 l 6.77l l1781NTlP 1l l

r l

l

}04/96l l C lTEC-TEHlTEC-TEHj l00086l5800Lj09H+ 10.61 l 5.01l l178j:NTlP 1l l

  • 28}110l04/96l l C lTEC-TEHlTEC-TEH!

l00091l500ULl0BH+ 19.59 l19.26l 1177CNTlP ll l

l 104/96l lC lTEC TEHlTEC-TEHJ l00091l5800Ll01C+ 30.48 l25.82l il771 NTlP 1l l

1 E9l111l04/96l lC lTEC-TEHlTEC-TEHl l00068l580ULlVM + 24.60 l 6.61l

!17310NTlP 1l l

91l111l04/96l lC lTEC-TEHlTEC-TEH(

l00086l580ULl09H+

0.00 l42.94) 11811:NTlP lj l

i 93l111l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.09 l48.58l

{176IONTlP 1l l

j 95l111]O4/96l lC lTEC-TEHlTEC-TEHj l00086l580ULl09H+

0.00 l31.16l 1181i:NTlP 1l l

' '3l111l04/96l lC lTEC-TEHlTEC-TEHj l00086l580ULl08H+ 17.97 l 6.56l l179i NTlP 1l l

l lC4/96l l C lTEC-7EHlTEC-TCHl l00086l580ULl09H-0.77 j 6.76l l1751NTlP 1l l

l l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H-C.68 l 5,50l

'179l:NTlP ll l

8 l

l l04/96l lC lTEC-TEHlTEC-TEHj l00086l580VLl09H-0.30 l10.12l

,179l:NTjP 1l l

1 l

l04/96]

lC lTEC-TEHlTEC-TEHj l00086l580ULl09H-0.18 l10.03l jl?6lONTlP 1l l

l l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09C+

0.96 l 9.67l l179lONTlP 11 l

i*19l111l04/96l l C lTEC-TEHlTEC TEHl l00086l580ULl10C+

0.99 l 8.65l l174j!NTlP 1l l

l l

l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09C+ 15.26 l 6.98l l174l0NTlP 1l l

l123l111l04/$6l l C lTEC TEHlTEC-TEHl l00091l580ULl10C-1.10 l13.95{

l179lONTlP 1l l

l 301112l04/96l lC lTEC-TEHlTEC-TEHj l00067l580ULl02C+ 10.97 l 6.74l l191lONTlP 1l l

j i 58l112 j 04/ 96 l l C lTEC-TEHlTEC-TEHl l00069l580JL} 07H+ 19.66 l 6,07l l180lDNTlP 1l l

l l

l04/94j lC }TEC-TEHlTEC-TEHl l00069l580ULl07H+ 20.54 l15.95l l100lONTlP 1l l

l 92l112l04/96l l C lTEC-TEHlTEC-TEHl l00086l5800Ll09H+

0.00 l25.13l l182lDNTlP 1l l

l 941112l04/96l l C lTEC-TEHjTEC-TEHj l00085l580ULl09H-0.06 l43.31l l175l0NTlP 1l l

l 96l112l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l22.79l l179lCNTlP 1l l

j l 9Bl112l04/96) l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+

0.00 l17.51) l179lDNTjP 1l l

)

1102l112l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+

0.09 l24.15l l176lDNTlP 1l l

j120l112l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl10H+

0.00 l54.86l 117BjDNTlP 1l l

l_L I I

L _I l

l_I I

l 1

l _ ! _ L_._ I _ I _ I ROCE. RIDGE TECHNOLOGIES i

i l

l

-~~

CUMUIATIVE REPORT 04/96, BCE, CALVERT CLIFFS. UNIT 1 i

i STEAM GENERAT n 11

AGE
18 OF 22

)

OCTTAGE DATA EET

CURRENT DATE:

06/06/96 SELEC' !ON VAR

  • ABLES : Percent TIME:

03:40:45

)

i l

l l EXAM l

l EXAM EXTENT l l

l l

l l

l ROW l*INl DATE' HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL lPROBEj LOCATION JVOLTSl MIL l:EGl % lCH lCHNGl i

i_ L._ l 1_i I

L._ l l

l j

f _l _ L._ l_ l_ l l

l122l112l04/96.

lC lTEC<TEHlTEC-TEHl l00085l580ULl20H+ 0.00 l18.71l l176lDNTlP 1l l

l 35l1:3[04/96:

l C lTEC-TEHlTEC TEHj jo0065l580ULlVM -

1.44 l 7.34l l 3lDNTlP 1l l

l 69);13l04/96' l C lTEC-TEHjTEC-TEHl l00068l5800L]VM + 24.46 l 6.78l j;73lDNTlP 1l l

l 91];;3l04/96 l C lTEC-TEHlTEC-TEHl l 00'08 6 ] 58 00Ll 0,9H +0.00 l36.44l l182lDNTlP1l l

l l 93l1'3l04/96 lC lTEC-TEHlTEC-TEHl l00085l5800Ll09H-0.09 l94.94l l173lDNTlP ll l

l 95l113l04/96 l C lTEC-TEHlTEC-TEHj l00086l58hULl09H+ 0.00 l29.47l l178lDNTlP 1l j

l 97l113l04/96 l C lTEC-TEHlTEC-TEHl l00085l580ULl09H- 0.12 l97.30l l U SlDinflP 1l l

l 99l;".3l04/96 l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+

0.00 l129.9l j*75lDN.lP 1l l

l101];;3l04/96 l C lTEC-TEHlTEC-TEHl j00085l580ULl09H+ 0.00 l74.27l lU 8lDNT P 1l l

l1031J.3l04/96 l C lTEC-TEHlTEC-TEHj l00086l580ULl09W+ 0.00 l36.36l l178lDNTlP 1l l

l105l;;3l04/96 l C lTEC-TEHlTEC-TEHl l00085l580ULl09He 0.00 l52.80j lU5lDNTlP1l l

l117!;;3l04/96 l C lTEC-TEHlTEC-TEHl l 00085 l 580UL j l0H+

0.00 l 50. 4 9 l l;i6lDNTlP 1l l

l121);'.3 j 04 /9 6 lC lTEC-TEHlTEC TEHl l00085l580ULl10H-0.03 l50.25l l D 6lDNTlP 1l l

l123 [;'.3 l 04 /96 l C lTEC-TEHlTEC TEHj l00091l580ULl10H- 0.06 l33.98l l1!1lDNTlP 1l l

l 12j:.14l04/96 lC lTEC-TEHlTEC-TEHl l00065l580ULl06He 8.02 l*4.87l

];13lDNTlP 1l l

l l

l04/96 l C JTEC-TEHlTEC-TEHl l 00065 l 580ULl 06C.10.41 l18.04l l;iOlDNTlP 1l l

l 921;A'l04/96 l C ITEC-TEHjTEC-TEHl l00066l580ULl09H+

0.00 141.24l l. 9 l DNTl P 1 l l

l 941;* 4 l04/96 lC lTEC TEHlTEC.TEHj l 000 0 5 l 580ULl 09F-0,06 l86.60l

};"4lDNTlP 1l l

l 96 !;'.4'l 04/9 6 lC lTEC-TEHlTEC-TEHl l00066l580ULl09H+

0.00 176.69l j;*5lDNTlP1l l

l 98l1".4l04/96 lC lTEC-TEHlTEC-TEHl l00085l580ULl09H.

0.00

!4 9.32 l l.*76lDNTlP 1l l

l100j;;4l04/96 lC lTEC-TEHlTEC-TEHj l00066l580ULl09H+ 0.00 l34.02l l~i3lDNTlP1l l

l102j;;4l04/96 lC iTEC TEHjTEC-TEHl l00065l580ULl09H-0.09 l37.77l l 7 6lDNTlP 1l l

l104l.;4l04/96 lC lTEC-TEHlTEC-TEHj l00086l580ULl09H.

0.06

[20.97l

[;i2lDNTlP 1l l

j l106l1;4l04/96 lC lTEC TEH]TE'C-TEHl l00065l580ULl09H.

0.00 l24.22l lP 7lDNTlP 1l l

l118l1;4l04/96 l C lTEC-TEHlTEC-TEHj l00005l52" A-0.00 l 6.48l 1 7 6lDNTlP 1l l

l122l;;4l04/96 lC lTEC-TEHlTEC-TEHl l 0008 5 W LIL t 10H.

0.00 l24.30l l P 5lDNTlP 1l l

l 69l*.;5l04/96 lC lTEC TEHjTEC-TEHl l 0006 9 l 680ULlVM. 24.84 l 6.49l jr 9lDNTlP 1l l

l 93j1'5l04/96 lC lTEC-TEHlTEC TEHl l00085l580ULl09H-0.09 l32.25l l1~6lDNTlP 1l l

l 97:.;5l04/96 lC lTEC-TEHlTEC-TEHl l 00'; e 5 l 58 0UL l 09H.

0.03 l35.36l l'*6lDNT[P 1l l

l101);;5l04/96 lC lTEC-TEHlTEC-TEHl l00085l580VLl09H.

0.36 l;5.49l l 7 6lDNTlP 1l l

11214;;5l04/94 l C lTEC-TEHlTEC-TEHj l00065l580ULl10H+

0.00 l 7.10l l1* 9lDNTlP 1l l

l 36;.;6l04/96 lC lTEC TEHlTEC-TEHj

]C0065l580ULl09H.

0.00 l29.13l lr 5lDNT[P 1[

l

}

l 98l1;6l04/96 lC lTEC TEHlTEC-TEHl l00086l580ULl09He 0.00 l23.94l l'i3lDNTlP 1]

l i

l106t*;6l04/96 l C lTEC-TEHlTEC-TEHl l00083l580ULl09He 0.15 l 5.14l lLi3lDNTlP 1l l

j l120);;6l04/96 lC lTEC-TEHlTEC-TEHl l00083l580ULl09H+

0.49 l 5.15l j ",5 3 l DNT l P 1 l l

l126l1*6l04/96 l C lTEC-TEHjTEC-TEHl l00100l580ULl09H- 0.24 l 6.27l l*79lDNTIP 1l l

l 69l;;7l04/96 l C lTEC TEHlTEC-TEHj l00069l580ULlVM + 25.01 l 6.69l l1 9lDNTlP 1l l

l 87); 7l04/96 l C lTEC-TEHlTEC-TEHj l000761580ULl06H+

8.49 l 6.12l lP7lDNTlP 1l l

l 91l*17l04/96 l C lTEC-TEHjTEC-TEHl l00083l580ULl09H+ 0.23

[ 6.67]

llillDNTlP 1l l

l107l117l04/96 lC lTEC-TEHlTEC TEHl l00083l580ULja9H+ 0.03 l15,92l l1f3lDNTlP 1l l

l 12l1*8l04/96 l C lTEC-TEHlTEC-TEHl l 00066 l 580ULl 06C+ 7.79 l13.58l l1f 2lDNTlP 1l l

l102i";8l04/96 l C lTEC-TEHlTEC-TEHl l00083l580VLl09H+ 0.17 l 7.70l l1f2lDNTlP lj l

l 69l";9l04/96 lC lTEC-TEHlTEC TEHj l00069l580ULlVM + 25.10 l 7.06l l r 9lDNTlP 1l l

l 91l;*9l04/96 lC lTEC-TEHlTEC-TEHl l00084l580UL]VM - 1.0; l13.53l lLi5lDNTlP 1l l

l l

l04/96 lC l TEC-TE.H lTEC-TEHl l00084l580VLl09C. 1.97 l15.63l lli4lDNTlP 1l l

1 _L__I l _I I

l_I I

I l

l l___ L_ L_ I_ I j

ROCT. RIDGE TECENOLOGIES i

I

I l

CUMULATIt'E REPC3T 04/96, BGE, CALVERT CLIFFS, UNIT 1 i

l STEAM CENERATOR

11 PAGE: 19 OF 22 Ot.f!' AGE DATA SET r CURRENT DATEi 06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 l

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl EATElHEATWl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl t lCH lCHNGl l

l,,,,,,,, l _ l l

l_j l

l_l l

l l

l _ l,_,l _ l,,_,j _ l f

l 97l119l04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULj09H+ 0.00 l35.98l l178lDNTlP 1l l

.l 99l119l04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULl09H+ 0.30 l16.85l l178lDNTlP 1l l

l 98l120l04/96l l C lTEC-TEHlTEC-TEHl l00084j5800Ll09H+ 0.21 l28.60l l178lDNTlP 1]

l l102l120l04/96l l C lTEC-TEHlTEC-TEHj l00b84l580ULlopH+

0.00 l17.16l l178lDNTlP 1l l

l106l120l04/96l l C lTEC-TEHlTEC-TEHl l00084l5800Ll09H+ 0.00 l38.92l l177lDNTjP 1l l

r l 69l121l04/96l l C lTEC-TEHjTEC-TEHl l00069l58hULlVM + 24.56 l 6.77l l179lDNTlP 1l l

l l 91l121l04/96l l C lTEC-TEHlTEC-TEHj l00081l580ULl09He 0.06 l23.06l l190lDNTlP 1l l

]

l l

l04/96l lC lTEC-TEHjTEC-TEHl l00081l580ULl09C+

0.49 l34.47l l185lDNTlP 1l l

f l

l l04/96l l C lTEC-TEHlTEC-TEHl l00081l580ULl09C- 0.52 l28.36l l184lDNTlP 1l l

l l

l04/96l lC lTEC-TEHlTEC-TEHl l00081l580ULl06C+ 18.52 l 8.27l l184lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHj l00081l5800Ll08C+17.63 l17.18l jl86lDNTlP 1l l

3 l 93l121l04/96l l C lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.03 l62.48l l185lDNTlP 1l l

l l 97l121l04/96l lC lTEC-TEHlTEC-TEHl l00081l580UL]O9H+

0.74 l 7'.29) l189lDNTlP 1l l

l105l121l04/96l l C lTEC-TEHjTEC-TEHl l00064l5800Ll09H+ 0.00 l11.54l' l175lDNTlP 1l l

l107l121l04/96l lC lTEC-TEHlTEC-TEHl l00084l500ULl09H+

0.00 l53.37]

l177]DNTlP 1l l

l109l121l04/96l lC lTEC-TEHlTEC TEHl l00084l500ULl08H+ 16.14 l 5.85l l358lDNTlP 1.]

l l

l' l04/96l lC lTEC-TEHlTEC-TEHj lC0084 l500ULl08H+ 18.52 l 9.37l l175lDNTlP 1l l

}

l 104/96]

lC lTCC-TEH}TEC-TEHl l00084l580ULl09H-2.74 l 6.73l l174]DNTlP 1l l

l l

l04/96l lC lTEC-TEHl72C-TEHl l00084l580ULl09H-0.18 l27.54l l178lDNTlP 1l l

l l

'}04/96l

} C lTEC-TEH]TEC-TEHl l00084l580ULl09C+ 1.17 l 1.06l l176lDNTlP 1l l

l 30l1 Dl04/96l lC lTEC-TEHlTEC-TEHl l00063l580ULl01H+ 12.91 l 8.55) l177lDNTlP 1l l

l l

l04/96j lC lTEC-TEHlTEC-TEHl lC0063l580ULl01H+ 13.46 l13.50l l176lDNTlP 1l l

l 38l122j04/96l l C lTEC-TEHlTEC-TEHj l00063l5800Ll04C+ 2.63 l22.56l l175lDNTlP 1l l

l 46l122!04/96l lC lTEC-TEHlTEC-TEHl lC0069l580ULlVM + 5.15 l 8.99l l179lDNTlP 1l l

l 92l122l04/96) lC lTEC-TEHlTEC-TElj 300081l5SCULl09H+ 0.00 l77.94]

l184lDNTjP 1l l

l 94l122l04/96l l C lTEC-TEHlTEC-TEHl l G 'J 081 l 58 0ULl 09H+ 0.00 176.89l l184lDNTlP lj l

l 96l122l04/96l lC l TEC-TEH l TEC-TE H j l03081]5800Ll09H+ 0.06 l11.75l 1185lDNTlP lj l

l102l122l04/96l lC lTEC-TEHjTEC-TEIl jfC081l560ULl09H-0.03 l 5.71]

l190lDNTlP 1l l

l106l122l04/96l lC lTEC-TEHlTEC-TEll

C061l580ULl09H+

0.15 l 5.08l l185lDNTlP 1l l

{

l 15l123l04/96l l C JTEC TEHlTEC-TE4l l00063l580ULl06H+

7.74 l17.58l l174lDNTlP 1l l

j j 69l123l04/96l l C lTEC TEHlTEC-TEHl l00069l580ULlVM + 24.80 j 7.11l l181lDNTlP 1l l

l 91l123l04/96l lC lTEC-TEHlTEC-TEHj l00081l580ULl09H+

0.09 l47.86l l185lDNTlP 1l l

l l

l04/96l lC lTEC-T1:HlTEC-TEHj l00081l580UL]09H+ 2.17 l13.42l l175lDNTlP 1l l

l 93l123l04/96l lC lTEC-TEHlTEC-TEHl l00081l560ULl09H+ 0.03 l55.82l l194lDNTlP 1l l

l 95l123l04/96l lC lTEC-TEHlTEC-TEHj l00081l580ULl09H+

0.09 l12.67l l183lDNTlP 1l l

l 97l123iO4/96l lC lTEC-TEHlTEC-TEHl l00081l580ULl09H+

0.03 l30.07]

l186lDNTlP 1l l

l

-l l04/96l lC lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 1.57 l13.72l l186lDNTlP 1l l

l101l123l04/96l l C lTEC-TEHlTEC-TEHj l00081l5800Ll09H+

0.06 l 6.81l l185lDNTlP 1l l

l123l123l04/96l lC lTEC TEH]TEC-TEHl l00092l5000Ljl0H-0.14 l 6.05l l172lDNTlP ll l

.l 92l124l04/96l lC lTEC-TEHlTEC-TEHl l00081l580VLl09H+ 0.15 l105.0l l183lDNTlP 1l l

l 94l124l04/96l l C lTEC-TEHjTEC-TEHl l00081l5800Ljo9H+ 0.29 l112.9l l183lDNTlP1l l

l l 96[124l04/96l l C lTEC-TEHlTEC-TEHl l00081l$80ULjVH + 15.50 l 8.17l l181lDNTlP 1l l

l 98l124l04/96) lC lTEC-TEHlTEC-TEhl l00081]580UL]09H+

0.09 l34.47l l186lDNTlP 1l l

l 35l125l04/96l lC lTEC-TEHlTEC-TSHl l00062l580ULl06H+ 21.83 l 5.88l l176lDNTlP 1l l

l

}

l l04/96l lC lTEC-TEHlTEC-TEHl l00097l580UL]06H+ 22.45 l 4.83]

l175lDNTlP 1]

l l

L_ l_I l

l_t l

l _._ I l

l 1

l_l __I_ L L_ I I

ROCKRIDGE TECHNOLOGIES I

l CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 20 OF 22 OWAGE DATA SET t CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL]EXPl CAL lPRODEl LOCATION jVOLTSlMILlDEGl t lCH lCHNGl L l__l l

1._ I I

l_1 I

I I

L L_l l_ _l l

l 69l125l04/96l l C lTEC-TEHlTEC-TEHl l00069l5800LlVM+25.11 l 6.90l l179lDNTlP 1l l

j 91l125l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+

0.00 l52.47l l185lDNTlP 1l l

f l 93l125l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.09 l71.37l l185lDNTlP1l l

l 99l125l04/96l l C lTEC TEHlTEC-TEHl l00099l580ULl0pH+ 0.06 l26.10l l186lDNTjP 1l l

l101l125l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09C+

9.80 l 5.27l l 10lDNTjP 1l l

l121l125l04/96l l C lTEC-TEHlTEC-TEHl l00081l586ULl06H+15.73 l19.53]

l180lDNTlP 1l l

l 12l126l04/96l l C lTEC-TEHlTEC-TEHl l00062l580ULl06C+

9.94 l17.73l l177lDNTlP 1l l

l 72l126l04/96l l C lTEC TEHlTEC-TEHl l00074l580ULl07C+ 18.92 l 9.34l l178lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHj l00068l580VLl07C+ 18.52 l 9.53l l175lDNTlP 1l l

l 82l126l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl07H+ 14.85 l15.30l l177lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00073l580UL]08H+

1.13 l14.26]

l177lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08H+ 10.34 l23.56l l173lDNTjP 1l l

.)

l l04/96l l C lTEC-TEHlTEC-TEHl

{00073l5800LlDH + 3.37 j15 33l il75lDNTlP 1l l

f l

l l04/96l l C lTEC-TEHjTEC-TEHl l00073l580VLlVH +

1.67 l23.26l l178lDNTlP 1l l

[

l l

l04/96l l C lTEC TEHlTEC-TEHl l00073l580ULlVH +

4.59 l 8.14l jl80lDNTlP 1l l

(

l l

l04/96l l C lTEC-TEHlTEC-TEHj l00073l5800LlVH +

5.51 l 7.51l l180lDNTlP 1-l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl jo0073l580ULlVM -

1.34 l 9.34l t175lDNTjP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C-0.69 l 6.02l

'179lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl07C+ 15.26 l 8.98l

.181lDNTlP 1l l

l 92l126l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+

0.09 l46.72l

!184]DNTjP 1l l

l 94l126l04/96l l C lTEC-TEHlTEC-TEHl jo0099l580ULl09H+

0.06 l79.21l 1184lDNTlP 1l l

l 96l126l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+

0.03 l86,10l

!183lDNTlP 1l l

l 98l126l04/96l l C lTEC.TEHlTEC-TEHj l00099l580ULl09H+

0.12 lh.ell

'186]DNTlP 1l l

l l 69l127l04/96l l C lTEC-TEHlTEC-TEHl l00069l580ULlVM + 25.10 l 6.69l

'179lDNTlP 1l l

l 91l127l04/96]

l C lTEC-TEHlTEC-TEHl l00079l5800Ll09H+

0.12 ls5.63)

'185lDNTlP 1l l

l l

j04/96l lC lTEC-TEHlTEC-TEHl l00079l580ULl09H+ 2,16 l22.51l

'176lDNTlP 1]

l l 93l127l04/96l l C lTEC-TEHlTEC-TSHl l00080l580ULl09H+

0.09 l72.76l

'177lDNTlP 1l l

l l

104/96l l C lTEC-TEHlTEC-TEHl

[00099l580ULl09H+

0.09 l78.25l 185lDNTlP 1l l

[

_l 95l127l04/96l l C lTEC-TEHlTEC-TEHj l00079l580ULl09H+

0.00 l25.94l 184lDNTlP 1l l

l 97l127104/96l l C lTEC-TEHlTEC-TEH]

l00099l580ULl09H+

0.00 l56.73l

.86lDNTlP 1l l

l l

l04/96l l C lTEC-TEH]TEC-01Hl l00080l580ULl09H+

0.06 l50.05l

!178lDNTlP 1l l

l 14l128l04/96l l C lTEC-TEHlTEC-TEHl l00057l580UL]O6C+

8.73 l16.46l li81lDNTlP 1l l

l 92l128l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULl09H+

0.00 l51.59l l180lDNTlP 1l l

l 98l128j04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl09H+

0.03 l 8.47l 1180lDNTlP lj l

l110l128l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULlVC+

2.27 l 6.53l l172lDNTlP 1l l

l107(129l04/96l l C lTEC-TEHjTEC-TEH) l000741580ULl09H+

1.71 l13.20l il78lDNTlP ll l

[

] 38l130l04/96l l C lTEC-TEHlTEC-TEHl l00061l580ULlC2H+ 32.40 l12.27l l176lDNTlP 1l l

l 69l131l04/96l l C lTEC-TEHlTEC-TEHj l00072l580ULlVM + 24.38 l 7.40l

!178lDNTlP 1l l

l 93l131l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl09H+

0.15 l19.00l 1179lDNTlP 1l l

l 38l132l04/96l l C lTEC-TEHlTEC-TEHl l00061l580ULlTSC+ 19.81 l 5.56l l172lDNTlP 1l l

l 92l132l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULl09H- 0.26 l 7.47l

!178lDNTlP 1l l

l 69l133l04/96l l C lTEC-TEHlTEC-TEHl l00072l5800LlVM + 23.54 j 8.35l

{178lDNTlP1l l

l l 95l133l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULl09H+

0.29 l 5.56l 1176jDNTlP 1l l

l 80l134l04/96l l C lTEC-TEHjTEC-TEHl l00072l5BOULl08H+ 15.21 l1b.15l l180]DNTlP 1l l

l 96l134l04/96l l C lTEC-TEHlTEC-TEHl l 0'J073 l 58 0UL l 09H+

0.30 l 5.51l 1177lDNTjP 1l l

L._i_ I I

l__ !

I L._ I I

I I

L_. L-._ l-l_ I_ t ROCKRIDGE TECHNOLOGIES j

CUMULATIVE REPORT 04/96, BGF. CALVERT CLIFFS, UNIT 1 STEAM 3ENERATOR

11 PACE: 21 OP 22 OUTAGE OATA SET t CURRENT DATE:

06/06/96 SELECT *0N VARIABLES: Percent TIMES 03:40:45 i

l l EXAM) l l EXM MENT l l

l l

l l

lROh jL3l DATElWT8! LEG lPPOGhAM] ACTUAL lEXPl CAL l PROBE l LOCATION lVOLTSjMILlDEGl t ICH lCHNGl l __ L_ I l

L _ L.

l L_._ l l

l l

l _ L-._l._l _ L _.i l 41l135 l04/96l l C lTEC TEHlTEC-TEHl 'l00058l580ULlVM -

1.76 l 5.92l l177lDNTlP il l

l l 69l115l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULlVM + 24.17 l 6.45l l176lDNTlP 1]

l l 97l13fl04/96l l C lTEC-TEHjTEC-TEHj l00073j580ULl09C+

0.64 l12.53l l179lDNTlP 1l l

l36l13fl04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULlV){4 1.84 l 5.98l l175lDNTlP1l l

l 31l m l04/96l l C lTEC-TEHITEC-TEHl l000581580UnivM -

1.68 l 6.86l l176lDNTjP ll l

I l 35l m l04/96l l C lTEC-TEHITEC-TEHI l00058l581utivM - 1.36 l 5.631 1178lDurlP 1l l

{

l69l11"104/96l l C lTEC-TEHlTEC-TEHl l00073l580ULlVM + 24.06 l 8.36l l174lDNTlP 1l l-

)

l 77l;3*j04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C-1.15 l6.30l l176lDNTlP 1l l

l l

l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl07C+ 16.89 l 6.06]

l179lDNTlP 1l l

l 97l13*l04/96l l C lTEC-TEHlTEC-TEHl jo0073l580UL]O7H+ 16.92 l 7.02l l175lDNTlP 1l l

l l

!04/96l l C lTEC TEHITEC-TEHI l 000n l 580ULl 08H+

0.48 l7.70l l175lDNTIP'tl l

l l

104/96l l C lTEC-TEHlTEC-TEHl l00073l5800Ll08H+

4.19 l 9.48]

l175lDNTjP 1l l

l l

. M /96l l C lTEC-TEHlTEC-TEHl l00073]580ULl08H+

7.72 l 9.18l l176lDNTlP 1l l

l l

iJ4/96l l C lTEC-TEHlTEC-TEHl l00073]580ULl08H+ 10.46 l10.30l jl75lDNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHl l00073l580UL]O8H+ 13.37 l 7.96l l175lDNTlP 1l l

l l

'04/)6l l C lTEC-TEHjTEC-TEHl l 00073 l5800Ll08H+ 19.93 l 7.66l l175lDNTlP lj j

l l

04/96l l C jTEC-TEHjTEC-TEHj l00073l580ULl09H-1.97 l 9.16l l175lDNTlP 1l l

l J

.04/96]

l C lTEC-TEHlTEC-TEHj l00073l580ULl09H- 0 47 l12.37l l176]DNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHl l00073l5800Ll09H+

0.80 l23.86l l176lDNTlP 1l l

l l

04/961 l C lTEC-TEHITEC-TEHI l00073l580ULl08C+ 17.90 l 9.06l l173lDNTjP 1l l

l l

<04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C+ 16.42 l 6.21l l174lDNTlP 1l l

l l

l 04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C+ 12.53 l 6.06l l174lDNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C+ 11.02 l10.55l l175lDNTlP lj l

l l

04/96l l C lTEC-TEHlTEC-TEHl l00073l5800Ll08C+

8.89 l 5.79l l176lDNTlP 1l l

l 46)n i 04/961 l C lTEC-TEHITEC-TEHl l 00058l58uULl 05H. 30.55 l 6.571 l180lDNTlP 1l l

l l

.04/96l l C lTEC-TEH{TEC-TEHl l00058l580ULl06H-2.32 l 6.53l l180lDNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHj l00058l580ULl06H+

0.21 l10.94l jl80lDNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHj l00058j580ULl06C+

4.56 l 9.20]

l181lDNTlP 1l l

l l

04/96l l C lTEC-TEHITEC-nHI l00058l580Utl06C+

2.66 l 7.53]

l181lDNTlP tl l

l l

04/96l l C lTEC-TEHlTEC-TcHj 100058l580UL]O6C.

1.18 1 9.581 1182lDNTlP li l

1 l 92l'3f:04/96l l C lTEC-TEHjTEC-TEHj l00074l580ULl09H+

0.0D l 5.44l l179lDNTlP 1l l

l 96l13i.04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULl09H+

0.62 l 6.49]

l185lDNTlP 1l l

l nl:39:04/96l l C lTEC-TEHITEC-TEHl l00058l580ULlvM - i.e2 l 9.84l l194lDNTIP il l

} 37l137.04/96l l C lTEC-TEHlTEC-TEHl l00059l580ULlVM -

1.57 l11.70l l176]DNTlP 1l l

l l

04/96l l C lTEC-TEHlTEC-TEHl l00059l580ULlVM +

1.86 l 9.14l l180lDNTlP 1l l

l 69); l04/96l l C lTEC-TEHjTEC-TEHl l00073l580ULlVM + 24.44 l 7.64l l174lDNTlP 1l l

l 35l;4; 04/96l lC lTEC-TEHlTEC-TEHl l00058l580ULlVM -

1.*

l 6.40l l 1lDNTlP 1l l

l 69l~41:04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULlVM + 24.36 l 6.45l l372lDNTjP 1l l

l 93l14'. 04/96l l C lTEC-TEHjTEC-TEHl j00073l580ULlTSH+ 28.50 l 7.44l l173lDNTjP lj l

l 38l:4:;04/96l l C lTEC-TEHITEC-TEHl l00058l580ULl0.C+

2.74 l 8.52l 1178lDNTIP 1l l

l 64l:4::04/96l l C lTEC-TEHITEC-TEHI l00059l580ULIDH. 24.63 l 8.84l 1175lDNTIP 1l l

l 90l:4::04/96l l C lTEC-TEHlTEC-TEHI 100074]580unlvM -

1.73 l11.10l l180lDNTjP 1l l

l 31l;43:04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULlVM -

1.60 l 5.22l l177lDNTlP 1l l

l 67l143104/96l l C lTEC TEHlTEC-TEHl l00074l580ULl07C+ 2.10 l 7.38l l177lDNTjP 1l l

l 69l1,3 '04/96l l C lTEC-TEHjTEC TEHl l00074l580UL]VM + 22.47 l 7.56l l179lDNTlP 1l l

l _._ I _

l I_]

l L__. I I

l l

L -l___l _l_-_i _ 1 ROCKRIDGE TECHNOLOGIES l

l l

~.. -. - -

~.

CUMUIATIVE REPORT 04/D6, BGE, CALVERT CLIFFS, UNIT 1 o

STEAM GENERATOR

11 PAGE: 22 OF 22 CITTAGE DATA SET i CURRENT DATE:

06/06/96 SELECTION VARIABLES: Percent TIME:

03:40:45 l

l l EXAM l l

l EXAM EXTENT l l

l l

l l

! ROW lLINl DATEl HEAT 8l LEG l PROGRAM l AC'!1JAL APl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl 8 lCH lCHNGl i

L _ L _l I

l_l l

1-_

1 l

l 1

l_l _l__l._ L _I j 37l145l04/96l l C lTEC-TEHjTEC-TEHl liOO59l580ULlVM -

1.72 l 8.01) l176lDNTlP 1l l

j l

l l04/96l l C lTEC-TEHlTEC-TEHj l00659l580ULlVM +

3.63 l 8.39) l178lDNTlP1l l

I 69l145l04/96l l C lTEC-TEHlTEC-TEHj l00t?3l580ULlVM + 24.32 l 8.69l l173lDNTjP 1]

l j 34l146l04/96l l C lTEC-TEHlTEC-TEHj l0df58l580ULlDH +

0.21 l 6.26l l177lDNTjP 1l l

}

l 85l147l04/96l l C lTEC-TEHlTEC TEHj l0007Jl580ULjo1H+ 22.72 l 8.60l l172lDNTlP 1l l

37l151l04/96l l C lTEC-TEHjTEC-TEHl l00059l$ foul lVM -

1.56 l13.55l l178lDNTlP 1l l

69l151l04/96l l C j"TC-TEHlTEC-TEHl l00074j5805lVM + 23.96 l 7.08l l178lDNTlP 1l l

69l153l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULlVM + 24.56 l 7.98l l171lDNTlP1l l

14l154!04/96]

l C lTEC-TEHlTEC-TEHl l00054l580UIl06C+

P.80 l17.57l l179lDNTlP 1l l

l 42l254104/96l lC lTEC-TEHlTEC-TEHl l00058l500%l01C+

1.69 l21.59l l181lDNTlP 1l l

l 104/96l l C lTEC-TEHjTEC-TEHl l00058lSesuLj07C+

1.10 115.281 1183lDNTlP 1l j

j l

l04/96l l C lTEC-TEHjTEC-TEHj l00058l5,OULl07C+

0.60 l22.05]

l181lDNTlP 1l l

{

l 104/96l lC lTEC-TEHlTEC-TEHl l00058l58)ULl07C-0.91 l 6.61l l182lDNTlP 1l l

l 04/96]

j C lTEC-TEHlTEC-TEHj l00058)".80ULl06C+ 20.24 l 5.45l l179lDNTjP 1l l

3 48l154 04/96l lC lTEC-TEHlTEC-TEHl l 0 0,8 l 5 0 0UL l DH -

0.42 l10.91l l177lDNTlP 1l l

69115s:04/96l l C lTEC.TEHITEC-TEHI lc2073l580UnivM + 24.73 i 6.42]

l176lDurlP 1l l

34l156:04/96l l C lTEC-TEHlTEC-TEHl l04056l580ULlVM +

3.76 l28.77l l175lDNTlP 1l l

38l156 04/96l 1 C lTEC-TEHITEC-TEHI l00'56l580ULl02H+ 32.27 l26.78]

l178lDNTIP ll l

l 13l157.04/96) lC lTEC-TEHlTEC-TEHl l00/53l580ULlVM +

0.21 l 7.04l l175lDNTlP 1]

l

)

31l157l04/96l l C lTEC-TEHjTEC-TEHl lfdOS6l580ULlVM -

1.70 l 9.20j l176lDNTlP 1l l

37l157-04/96l lC lTEC-TEHjTEC-TEHj l00057l580ULjVM +

5.29 l12.12l l176lDNTlP 1l l

I 571157 04/96l l C lTEC-TEHlTEC-TEHI l00057l580ULl07H+

2.86 l22.72l l175lDNTlP il l

l 55l159 04/96l 1C lTEC-TEHITEC-TEul 100056l580unlvM.

1.97 l11.54]

l176lDNTIP 1l l

13l161'04/96l l C lTEC-TEHjTEC-TEHl l00050l580ULl06C+

8.18 l13.68j jl82lDNTlP 1l l

31l161'04/96l lC lTEC-TEHlTEC-TEHl l00057l5FMVM -

1.49 l 8.99l l178lDNTlP 1l l

31l163:04/96]

l C lTEC-TEHlTEC-TEHl l000f6l580ULlVM 1.66 l 8.78l l175lDNTlP lj j

35l163404/91l lC lTEC-TEHlTEC-TEHl l00056l580ULlVM -

1.97 l 7.31l l180lDNTlP 1l l

l l_

l l_l l

l_l l

l l

l _ l _ l _ l

_.I _ I 7.YdER CT TUHES SELECTED FROM CURRENT OUTAGE:

841 DEER CF DATA RECORDS SELECTED FROM CURRENT OUTAGE:

972 20 TRENO ANALYSIS REQUESTED OATA EELE" TION CRITERIA:

Dreent: ONT

.~.EPORT C CIONS:

Or.ly exa-ination results matching criteria are included I

1 I

ROCKRIDGE TECHNOLOGIES

~

~. ~. -

-.,~ - -_ _-

~ - - - -

. ~. -. - -.

l CUMULATIVE REPORT l

04/96, BCE, CALVERT CLIFFS. UNIT 1 l

STEM GENERATOR 11 PAGEr 1 OF 15 OtTTA';E DATA EET CURRENT i

DATE:

06/06/96 i

SELE:* ION VARU.BLES: Indication location, Percent TIMEt 03:57:17 l

l l

I f

l l EXA

l l EXAM EXTENT l l

l j

j l

l ROW "1Nl DATI HEAT #lLD3(PROGRAM l ACIUALlEXPl CAL lPROBEj LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_ _I l_f I

l_l i

I I

L_. l._ l L_ L_ l l 97 29l04/96i l C lTEC-TEHlTEC-TEHl l00028l540ULjo9H-0.35 l 8.71l l176lDNTlP 1l l

s l 96 30l04/96.

l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.24 l13.15l l181lDNTlP 1l l

l 95 30104/96 l C lTEC TEHlTEC-TEHI 100,028158 0VLl 09H+

0.06 l13.41l l175lDNTjP1l l

l 91 31l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULl0SH+

0.00 l 8.14l l176lDNTjP1l l

l l 96 32l04/96:

l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.36 l10.71l l181lDNTlP 1l l

I 97 33104/96-1 C lTEC-nHlnC nHI l00028l58tULl09H+ 0.44 l 6.25l l179lDNTIP1l l

'101 35l04/96 l C lnC-nHITEC-TEHl l 00028 ! 580ut.l 09H+

0.00 l 7.96l 1172lDerfjP 11 l

l 91 37l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l52.00l l174]DNTlP 1l l

j 93 37l04/96 l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+

0.00 l26.01l l176lDNTlP 1l l

l l 97 37104/96 l C lTEC-TEHlTEC-TEHl l00028l580VLl09H+ 0.00 l32.32l l178lDNTlP1l l

1 l 92 38l04/96 l C lTEC-nHinC-TEHj l00026l580ULl09H+ 0.00 l15.59l l176lDNTlP1l l

l 94.38l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULl09H+

0.00 l55.67l l177lDNTlP 1l l

l 96 38l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l43.29l l177lDNTlP 1l l

l1C: 38l04/96 lC lTEC-TEHlTEC-TEHl l00028l580VLl09H+ 0.00 l37.59l l176lDNTlP 1l l

l l

9',

39]O4/96 lC lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l61.00j l177lDNTlP 1l l

l 93 39l04/96 l C lTEC-TEHlTEC-TEHj l00028(580ULl09H+

0.00 l61.77l l176lDNTlP 1l l

l 95 39l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l57.41l l178lDNTlP 1l l

l l11-39l04/96 l C lTEC-TEHITEC-TEHI l00028l580ULliOH. 0.c0 l 9.02l l177lDNTIP 1l l

l 94 40l04/96 lC lTEC-TEHlTEC-TEHl l00028l580ULl09H+

0.03 l76.94l l181lDNTlP 1l l

I l10: 40j04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULl09H+

0.00 l20,46l l179lDNTlP 1l l

l10; 40l04/96 lC lTEC-TEHlTEC-TEHl l00020l580ULl09H-0.30 l53.07l l178]DNTlP 1l l

l 9'

41l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 197.18l l176lDNTjP 1]

l

(

l 93 41l04/96 lC lTEC-TEHlTEC-TEHl l00028lb80ULl09H+

0.12

{19.38l l182lDNTlP lj l

}

l 95 41l04/96 l C {TEC-TEHlTEC TEHj l00029l5POULl09H+

0.00 l71.73l l176lDNTlP 11 l

l 9-ul04/96 l C lTEC-TEHlnC-TEHI lc0028ls80ULl09H+

0.06 148.06l 1184lDNTIP ll l

l 95 ul04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l26.85l l177lDNTlP 1l l

l10' 41l04/96 lC lTEC-TEHlTEC-TEHj l00028l580ULl09H+

0.03 l78.95l l181lDNTjP 1l l

l l1e1 ul04/96 lC lTEC-nHlnC-TEH j l00029l580ULl09H.

0.00 l39.51l 1176lDNTlP il l

ln 42104/96 lC lTEC-TEHITEC-TEHI ic0029l500ULl09H+

0.00 l45.98}

l178]DNTlP ll l

l l 94 42l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULj09H+

0.00 l15.51l l179lDNTlP 1l l

l 9f 42{04/96 lC lTEC-TEHlTEC-TEHj

{00028l580ULl09H+

0.03 l74.81l l182lDNTlP 1l j

l 93 42l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00, l117.1l l177lDNTlP 1l l

l l10: 42104/96 i C InC-TEHITEC-nH l l00026l580ULl09H+

0.00 181.32l l181lDNTIP 1l l

{

l102 42l04/96 l C lTEC-TEHlTEC-TEHl l00029l580UL109H+

0.00 l83.77l l177lDNTlP 1l l

l104 42l04/96 l C lTEC-TEH}TEC-TEHl l00028l580ULl09H+ 0.12 l 6.73l l180lDNTlP 1l l

l106 uj04/96 l C lTEC-TEHlTEC-TEHl l000291580ULl09H+

0.00 l31.86l 1178lDNTIP 11 l

l 91 43l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULl09H+

0.00 l50.85l l178lDNTlP 1l l

l 93 43l04/96 l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+

0.06 l47.08l l183lDNTlP 1l l

l 95 ul04/96 l C lTEC-TEHITEC-TEHl l000291580ULl09H.

0.00 l 6 9.141 l178lDNTIP ll l

l 97 43l04/96 l C lTEC-TEHlTEC-TEHl l00028l580ULl09H- 0 06 1163.0l l178lDNTjP 1l l

l 99 43l04/96 l C lTEC-TEHlTEC-TEHj l00029l580ULl09H+

0.00 l68.02l l177lDNTlP 1l l

l103 43l04/96 j C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l72.27l l177lDNTlP 1l l

l1C3 43l04/96 l C lTEC-TEHlTEC-TEHl J00028l5800Ll09H+

0.09 l78.31l l180lDNTlP 1l l

l 92 44l04/96 l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l95.99l l177lDNTlP 1l l

l 94 44l04/96 lC lTEC-TEH]TEC-TEHl l00028l580ULl09H+

0.06 l125.6l l179lDNTlP 1l l

l_ _I l ___ I l

L_ l l

l 1

L_ l __ I_ L._. l._ __ l t

ROCTJtIDGE TECHNOLOGIES a

_.m._;..

l CUMULATIVC REPORT 04/96, BGE, CALVERT CLIFFS. UNIT 1 STEAM GENERATCR 11 PAGE:

2 OF 15 OUTA';E DATA SET CUldiENT DATE:

06/06/96 SELECTION VA3EIABLES: Indication Location. Percent TIME:

03:57:17 l

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

1 l ROW lLINl DATEl HEAT #l LEG lPPOGRAMl ACTUAL lEXPl CAL lH.0BEj

.COATION l VOLTS l MIL lDEGl 8 lCH lCHNGl l_L _I I

L._ I 1

l_I I

I I

l_ _ l._ l _ l._ _I _ 1 l 96l 44l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+

0.00 l41.17l l179lDNTlP 1l l

l l 98l 44l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+ 0.00 l80.26l l180lDNTlP 1l l

l100l 44l04/96l l C lTEC-TEHlTEC-TEH) l00029l560UL]O90 0.00 l42.64 l l178lDNTlP lj l

l102l 44l04/96l l C lTEC-TEHlTEC-TEH) l 00028 l58 0UL! 0,9H+

0.00 l72.64l l182lDNTlP 1l l

l104l 44l04/96l l C lTEC-TEH!TEC-TEHj l00029l5800Ll09He 0.00 l78.14l l178lDNTlP 1l l

l1121 44l04/96l l C lTEC-TEHlTEC-TEHj l00029l540UL]09H+ 0.00 l20.74l l180lDNTjP 1l l

l 91l 45l04/96!

l C lTEC-TEHjTEC-TEHl l 00029 l 5 6 0UL l 0,9H+

0.00 l60.77!

l178lDNTlP 1l l

1 l 93l 45l04/96'.

l C lTEC-TEHlTEC-TEH) l00028ltiOULl09H-

  • 09 l132.2]

l179lDNTlP 1l l

l 95l 45l04/96' l C lTEC-TEHlTEC-TEHi l00029l5800Ll09H+

0.00 l44.24]

l178lDNTlP 1l l

l 97) 45l04/96:

l C lTEC-TEHlTEC-TEH]

l00026l5iOULl09H+

0.00 j28.19l l181lDNTjP 1l l

l 99] 45l04/96 l C lTEC-TEHlTEC-TEHj l00029l5i3ULl09W 0.00 l33.37l l177lDerTl P 1l l

l101l 45l04/96 l C lTEC-TEHlTEC-TEHj l00028l560ULl09H-0.06 l32.41l l182lDNTlP 1l l

l103] 45l04/96 l C lTEC-TEHjTEC-TEHl jo0029l560ULl090 0.00 l14'. 67 l l178lDNTlP 1]

l l105) 45l04/96 lC lTEC-TEHlTEC-TEHl l00026l5iOULl09H+. 15 l 7.19l l181lDNTlP 1l l

l109l 45l04/96 lC lTEC-TEHlTEC-TEHI l 00 02 8 l!! 0ULl 0 9L 15 l 9.37l l181lDNTlP lj l

l 92) 46l04/96 lC lTEC-TEHlTEC-TEH!

l 0 0 0 30 l 5 i 3ULl 09L

  • .00 l127.4l l174lDNTlP 1l l

l 94l 46l04/96 j C lTEC-TEHlTEC-TEHI l C 0 0 3 0 l E i OULl 0 9H+

. 24 l24.37]

l176lDNTlP 1l l

l 96l 46l04/96 lC lTEC-TEHlTEC-TEHl

[00:30j5iOULlC9H+

'.00 l74.29l l175lDNTlP 1l l

l 98l 46l04/96 lC lTEC-TEHlTEC-TEHi l0:030l5i:ULl09b. 00 l73.00l l178lDNTlP lj l

l100l 46iO4/96 lC lTEC-TEHlTEC-TEH1 l 0 0 0 30 l E i OUL l 09b

.00 l52.79l l178lDNTlP 1l l

l102l 4fl04/96 lC lTEC-TEHjTEC-TEHI l00030j5!0Utl09H+

".12 l39.34l l177lDNTlP 1l l

l110l 46104/96 lC lTEC TEHlTEC-TEH1 l0::30l5 lLLl09H+

.15 l 5.67l l177lDNTlP 1l l

l114} 46l04/96 lC lTEC-TEHlTEC-TEH' l0::30l5t0ULl09H+

.12 l29.98l l178lDNTlP 1l l

l 91l 47{04/96 lC lTEC-TEHlTEC-TEH; l0:230l!! ULl09H+

.00 l80.75l l176lDNTlP lj l

l 93l 47l04/96 lC lTEC-TEHjTEC-TEHj l 0 0 2,3 015 !0ULl 090

-.03 l91.56l l176lDNTlP1l l

l 95j 47104/96 lC lTEC-TEHlTEC-TEH!

l0:030l5 0ULl09W

.00 l77.14l l177lDNTlP 1l l

l 97l 47l04/96 lC lTEC-TEHlTEC-TEH' l 0 ~ : 3 0 l! t :ULl 0 9b

.00 l16.93l l178lDNTlP 1l l

l 99l 47lC4/96 lC lTEC-TEHlTEC-TEH' l 0 0 : 3 0 lii:UL l 096

.00 l50.38l l176lDNTlP 1l l

l105! 47104/96 lC lTEC-TEHlTEC-TEHl l0 ;30j5t0ULl09H+

.00 l24.49l l177lDNTlP 1l l

l115.l 47!04/96 lC lTEC-TEHlTEC-TEHj l00:30l!!OULl09H+

  • .00 l14.51l l178lDNTlP 1l l

l100l 48l04/96 lC lTEC-TEHlTEC-TEHI l 0 0 : 3 0 l 5 E OULl 0 9H+

.00 l108.1l l177lDNTlP lj l

l102l 46104/96 lC lTEC-TEHlTEC-TEH!

l C C : 30 l 5 i OUL l 09H+

.00 l22.12l l178lDNTlP lj l

l110l 4Sl04/96 lC l TEC-TE*1lTEC-TEH j l00 30l5500Ll09H+ *.15 l16.38l l177lDNTlP 1l l

.l114l 48104/96 lC lTEC-TEHlTEC-TEHj l 00 :3 0 l S t 0ULl 09H +

15 l37.37l l178]DNTjP 1l l

l 93l 49]D4/96 lC lTEC-TEHjTEC TEHl l 000 30 l 5 i OULl 09H-0.03 l26.81l l178lDNTlP1l l

j j 95] 49l04/96 lC lTEC-TEHjTEC-TEHl l00030l560ULl090 0.09 l37.99l l178lDNTlP 1l l

j l101] 4 9l04/96 l C lTEC-TEHlTEC-TEH) l 0 0 03 D j ii 0ULl 09H+

0.00 l12.44l l179lDNTlP 1l l

j l103) 49l04/96 l C lTEC-TEHlTEC-TEHj l 0 0030 l!i OULl 0 9H +

0.00 l19.09l l180lDNTlP 1]

l l105l 49104/96 lC lTEC-TEHlTEC-TEHl l 00 0 30 l E i OULl 0 9H+

0.09 l 9.81l l178lDNTlP 1l l

l109l 49l04/96 l C lTEC-TEHlTEC-TEHl l 0 0030 l 5 8 0VLl 09H-0.09 l 5.85]

l177lDNTlP 1l l

1111l 49104/96 l C lTEC-TEHlTEC-TEHl l 00 0 3 0 l 5 i OUL j 09H +

0.00 l 8.75l l179lDNTlP 1l l

l115l 49104/96 l C lTEC-TEHlTEC-TEHj l 0 0 03 0 l 5 5 0ULl 09b 0.06 l24.84l l178lDNTlP 1l l

l121l 49104/96 l C lTEC-TEHlTEC-TEH]

l 00030 l 5 5 0ULl 09H+ 0.24 l13.09l l178lDNTlP 1l l

l 92l 50j04/96 lC lTEC-TEHlTEC-TEHl jo0031l550ULl09H- 0.12 l24.86]

l180]DNTlP 1l l

l 94) 50l04/96 lC lTEC-TEHlTEC-TEH]

l C 0 0 3 0 l 5 ! 0UL l 0 9H-0.06 l47.79) l182lDNTlP 1l l

I_I_l I_l l

Ll l

l l

l_l

!_l_!

I l

RLCKRIDGE TECHNOLOGIES i

t 1

l

I l

[

CUMULATIVE REPORT 04/96, BCEi CAbtfERT CLIFFS, UNIT 1 STEAM GENERATCR s 11 PAGE:

3 OF 15 OUTAGE DATA SET

CURRENT DATE:

06/06/96 i

SELECTION VARIALLES: Indication locatico Pen 2nt TIMER 03:57:17

+

j

'l l

l EXAMf l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATE 't EAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lOEGl 4 lCH lCHNGl l

l_ l I

l_l i

l_l l

l 1

l_l-_.L l_l_ _I i

l 98l 50l04/96 l C lTEC-nHjTEC-TEHl l00030l580ULl09H+

0.00 l42.87l l179lDNTjP 1l l

1100l 50l04/98.

l C lTEC-nHlnC-TEHI l00031l580ULl09H+

0.00 l38.68l l180lDNTlP 1l l

l102l 50l04/96 l C lnC-nHlTEC-TEHl l00030l5800Ll09H+

0.00 l38.43l l160lDNTlP 1l l

j l 91l 51]D4/96:

l C lTEC-TEHlTEC-TEHj l00'031l580ULl0pH+

0.00 l37.94l l179lDNTjP 1l l

l l 93l 51l04/96i l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+

0.06 l75.79l l178lDNTlP lj l

l 951 51104/96<

l C lTEC-TEHjTEC-TEHi l00031158bULl09H+ 0.06 l41.59l l180lDNTlP 1l l

-l101l 51l04/96 l C lTEC-TEHjTEC-TEHl l00030l580ULl09H+

0.00 l68.16l l178lDNTjP 1]

l 11031 51104/96 l C ITIC-TEHlTEC-TEHl l00031l580ULl09H+ 0.09 l29.30) l19 0lDifflP 1l l

l l105l 51l04/96 l C l:IC-nHlnC-TEHl l00030l580ULl09H+

0.00 l10.91l l179lDNTlP 1l l

l 92} 52l04/96 l C lTEC-TEHlTEC-TEHl l00031l580ULl09W+

0.09 l93.11l l178lDNTlP 1l l

l 94l 52l04/96 lC lTEC-TEHlTEC-TEHl l00030l580ULl09H-0.03 l69.32l l178lDNTlP 1l l

l l100l 52l04/96 l c ine-TEHinC-TEHl iO00311580utl09H+

0.00 199.28l l175lDNTlP 1l l

'l102l 52l04/96 l C l TIC-TEHjTEC-TEHl l00030l580UL]O9H+

0.03 l80.61l l181lDNTlP 1l l

l104l 52l04/96 l C l7IC-TEHlTEC-TEHl l00031l580ULl09H+ 0.06 l36.51l l160lDNTlP 1l l

l106l 52104/96 l C l:ZC-nHlTEC-TEHl l00030l580ULl09H+

0.03 l19.68l l178lDNTlP 1l l

l 91) 53l04/96 l C l7EC-TEHlTEC-TEHl l00031l5800Ll09H-0.33 l78.29l l177lDNTlP 1l l

l 93l 53l04/96 l C l TIC-TEHlTEC-TEHl l00030l580ULl09H+

0.00 l97.52l l~78lDNTlP lj l

l 95] 53l04/96 l C l7IC-TEHlTEC-TEHl l00031l580ULl09H-0.03 l101.9l lM9lDNTlP 1l l

l 99l 53l04/96 l C l7IC-TEHlTEC-TEHl l00031l580ULl09H-0.33 l13.10l

!!78lDiffjP 1l l

l101l 53l04/96 l C l TIC-TEHlTEC-TEHj l00030l580ULl09H-0.06 l48.13l l178]DNTlP 1l l

l103l 104/96 lC l:IC-TEHlTEC-TEHl l000311580ULl09H+

0.00 l98.93l lM8lDNTlP 1l l

l105] 53104/96 lC l:IC-TEHITEC-TEHl l000301580ULl09H.

0.00 l102.8]

1177lDNTlP lj l

l101l 53l04/96 l C l:IC-TEHlTEC-TEHI l00031l580ULl09H+

0.06 l49.87l l* 79lDNTlP 1l l

i l109l 53l04/96 l C l TIC-TEHlTEC-TEHl l00030l580CLl09H+

0.03 l34.78l l177lDNTlP 1]

l l111l 53l04/94 l C l TIC-TEHlTEC-TEHj l00031l580ULl09H-0.06 l23.06l-l161lDNTjP 1l l

l 92l 54l04/96 lC l7EC-TEHlTEC-TEHl l00030l580CL]O9H+

0.00 l69.82l l178lDNTlP 1l l

[

l 94j 54l04/96 l C l7IC-TEHjTEC-TEHl l00031l580ULl09H+

0.09 j78.50l lli3lDNTjP 1l l

I l 96l 54l04/96 l C l7IC-TEHjTEC-TEHl l00030l580ULl09H-0.12 l99.02l l1!2lDNTlP 1l l

l 98l 54l04/96 l C (7IC-TEHlTEC-TEHl l00031l580U*l09H+

0.00 l45.73l lliOlDNTjl 1l l

l1001 54l04/96 iC l:IC-TEHITEC-nHl l00030l580ULl09H+ c.03 (76.351 l179lDNTIP 1l l

l102l 54l04/96 l C l:IC-TEHITEC-TEHj l00031l580uLl09H-0.03 l220.7l lM6lDNTIP ll l

l104l 54lC4/96 l C l TIC-TEHlTEC-TEHl l00031l580ULl09H+

0.12 l45.41l l179lDNTlP 1l l

{

l110l 54]04/96 l C ITrC-TEHlTEC-TEHl l00030l580ULl09H+

0.00 l12.69l l179lDNTlP 1l l

l 91l 55l04/96 l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+

0.00 l$3.90l 1179lDNTlP II l

l 93l 55l04/96 l C l~EC-TEHlTEC-TEHl

{00030l580ULl09H-0.03 l50.50l l177lDNTlP 1l l

l nl 55l04/96 l C lnC-nHlnC-nHl l000311580ULl09H+ 0.15 l10.99l l1!0lDNTlP il l

l 97l 55l04/96 l C l TIC-TEHlTEC-TEHl l00030l580ULl09H-0.03 l86.40l l178lDNTlP 1l l

l 99l 55l04/96 l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.03 l52.95l l179lDNTlP 1l l

l1011 55l04/96 l C In C-TEHlTEC-TEHI l00030j5800Ll09H+

0.03 l114.9l lM8lDNTlP 1l l

l103l 55l04/96 l C l TIC-TEHlTEC-TEHl l00031l580ULl09H+

0.06 l82.64l lM9lDNTlP 1l l

l105l 55l04/96 l C l TIC-TEHlTEC-TEHl l00030l580ULl09H+

0.06 l35.83l l160lDNTlP 1l l

l1111 55l04/96 l C lnC-nH jTEC-TEHl l00031l580ULl09H-0.06 l30.20l Ilf0lDNTjP lj l

l113l 55l04/96 l C l TIC-TEHlTEC-TEHl l00010l580ULl09H+

0.15 l 9.19l l177lDNTlP 1l l

j l 92l 56l04/96 l C l TIC-TEHlTEC-TEHl 100033l580ULl09H+

0.03 l35.35l l165lDNTlP ll l

l 94] 56l04/96 l C l7IC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l135.5l lM3lDNTlP 1l l

I _ l _ l-l _._ I l

l_l I

i I

L l_l_l_i_l i

ROCERIDGE TECIDIOLOGIES I

i

~

a i

CUMULATIVE REPORT 04/06, BGE, CALVERT CLIFFS, UNIT 1

)

STEAM GENERATOR 11 PAGE:

4 OF 15 OUTAGE DATA SET

CURRENT DATEt 06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME:

03:57:17 j

l l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINj DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPj CAL lPROBEjLOCATION l VOLTS l MIL lDEGl t lCH lCHNGl L _I _ I I

L__I I

l.__ l l

I I

l_ _L _I_

L l.: ]

l 96l 56l04/96l j C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

9.00 l65.80l l180lDNTlP1}

}

l100l 56l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.00 l60.42l l181lDNTlP 1l l

l102l 56l04/96l l C lTEC-TEHjTEC-TEHj l00032l580ULj09H+

3.00 l19.47l l176lDNT[P 1l l

l104) 56]D4/96l l C lTEC-TEHlTEC-TEHj l 0 0'033 l 58 0ULl 0,9H + 3.00 l71.18l l180lDNTlP1l l

l l106l 56l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 3.00 l31.37l l176lDNTjP1l l

l110l 56l04/96l l C lTEC-TEHlTEC-TEHl l00030l58hULl09H+ 3.09 (11.80l l179lDNTlP1l l

l112l 56l04/96l l C lTEC-TEHjTEC-TEHl l00031l580ULl09H+ :.00 l11.12l l181lDNTlP1l l

l 91] 57l04/96l l C lTEC-TEHlTEC-TEHl lC0033l580ULj09H+

.00 l37.15l l181lDNTlP 1l l

l 93} 57104/96l l C lTEC-TEHlTEC-TEH) l00032l580ULl09He

.00

[122.8l l174lDNTlP 1l l

l 95[ 57l04/96l l C lTEC-TEHjTEC-TEHj l00033l580ULl09H+ :.09 1103.1l l184lDNTlP 1l l

l 97l $7l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

.00 l131.2l l174lDNTlP'll l

- )

l 99l 57l04/96l l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H+

0.00 l25.96l l181lDNTlP 1l l

l101l 57l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

.00 l35.81l l176lDNTlP 1l l

l l203l 57l04/96l l C lTEC-TEHlTEC-TEHl lC:033l580ULl09H+

.00 l14.28l l182lDNTlP 1l l

j l105l 57l04/96l l C lTEC-TEHlTEC-TEHj l c 0 032 l 58 0ULl 0 9H +

00 l35.43[

l1*l6lDNT[P 1l l

l107l 57l04/96l l C lTEC-TEHlTEC-TEHl lC0033l580ULl09H+

.00

[26.57l l181lDNTlP 1l l

l111l 57j04/96]

l C lTEC-TEHjTEC-TEHl lC0033l580ULl09H+

.00 l18.09l l182lDNTlP 1l l

j l 92; 38]C4/96)

] C lTEC-TEHlTEC-TEHj l C ; 0'3 3 ] 5 80UL f 0 9H.

.00 l30.58l l181lDNTlP 1l l

l 94l 58l04/96l l C lTEC-TEHlTEC-TEHj l0:032l580ULl09H-

.06 1151.4l l176lDNTlP 1l l

l 96) 58l04/96) l C lTEC-TEHlTEC-TEHl lC0033[500ULl09H.

.00 l56.46l l181lDNTlP1l l

l 98l 58l04/96l lC lTEC-TEHlTEC-TEHj l C;.,32 } 5 60UL j 09H+

0 'i (57.17l l177lDNTlP 1l

}

l100l 58l04/96l l C lTEC-TEHlTEC TEHj lC0033l560ULl09H+

.00 l22.69l l184lDNTlP 1l l

l1021 58l04/96l l C lTEC-TEHlTEC TEHl l0*032l590ULl09H+

.00 l 7.59l l175lDNTlP 1l l

1106) 58l04/96l l C lTEC-TEHlTEC-TEHj l0:032l590ULl09H+

00 l13.07l l176lDNTlP lj l

l 91i 19l04/96l l C lTEC-TEHlTEC-TEHl l00 33l580ULl09H+

.00 j43.01l l181lDNTlP 1l l

l 93l 59l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

.00 l127.7l l173lDNTlP ll l

l 95] 59l04/96l l C lTEC-TEHjTEC-TEHj

[0:033[580ULl09H.

.00 l65.41l l182lDNTlP 1l l 97l 59l04/96l l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+

.00 l48.49l l176lDNTlP 1l l

l1051 59l04/96l l C lTEC-TEHlTEC-TEHl lC0032l580ULl09H+

.00 l15.00[

l177lDNTlP 1l l

{107! 59l04/96]

l C lTEC-TEHlTEC-TEHl l C 0 033 l5 80UL l C 9H.

,00 l 5.83l jl80lDNTlP 1l l

1 921 60l04/961 l C lTEC-TEHlTEC TEHl lC0033l580ULl09H-

.12 l86.91l l184lDNTlP 1l l

l 94! 60l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULlD9H+

.00

{80.11l l175lDNTlP 1l l

l 961 60l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-

.14 l71.88l l179lDNTlP 1l l

l 98l 60l04/96l l C lTEC-TEHlTEC-TEHl l00032l5BOULl09H.

,00 l57.36l l177lDNTlP 1l l

} 91l 61104/96l lC lTEC-TEHlTEC TEHl l00033l5800Ll09H-0.33 l90.27l l177lDNT[P 1]

l l 93) 61]04/96l l C lTEC-TEHjTEC+TEHl l00032l580ULl09H.

.00 l75.62l l174lDNTlP1l l

l 95l 61l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

.06 l20.71l l185lDNTlP 1l l

l 97l 61l04/96l l C lTEC-TEHjTEC-TEHl l 00032 l5 80ULl 09H+

. 00 l91.42l l175lDNTlP ll

{

7 l 99l 61l04/96l j C lTEC-TEHlTEC-TEHl j

l101] 61[04/96l l C lTEC-TEHlTEC-TEHl_

l00033l580UL]C9H-

  • 22 l47.97l l180lDNTlP 1l l

l00032l5800Ll09H+

.00 l40.58l l175lDNTlP ll l

5

' l103] 61l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

.00 l 7.67l l179lDNTlP1, l

l105? 61l04/96l l C lTEC-TEHlTEC-TEHl l0C032l580UL]O9H+

.00 l34.4Bl l175lDNT[P 1l l

l107l 61l04/96l l C lTEC TEHlTEC-TEHl l00033l580ULl09H-

.03 j28.26l l185lDNTlP 1l l

l109) 61]D4/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

.00 l24.91l l174lDNTlP1l l

1 l1131 61l04/96l l C lTEC-TEHlTEC-TEHj lC0032l5800Ll09H+

.00 l26.12l l176lDNTlP 1l l

l _ L_ l.

1 L _1 l

lI I

I I

L _ I_ !___ L._ l.___ I 1

4 ROCKRIDGE TECIDIOLOGIES 1

CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

5 OF 15 OtJTAGE DATA SET r CURRENT DATE:

'4/06/96 SELECTION VARIABLES: Indication location, Percent TIME:

C3:57:17 s

l l

l EXAM l l

l EXAM EXTENT l l

l l

l l

l ROW lLINl DATElHEATNl LEG l PROGRAM l ACTUALjEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl t lCH [CHNGl L _l.__l i

1_I l

l_l I

l 1

l _ i __ I-._ L _ L_ _ l lt15l ul04/96l l C lnC-TEHITEC-TEHj l00033l580utl09H- 0.28 l15 51l l182lDNTIP ;l i

l 921 62104/96l l C lTEC-TEHlTEC-TEHl l00033lb80ULl09H-0.39 l46.08]

l179lDNTlP

  • l l

l 94l 62l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H- 0.06 l27.80l l183lDNTlP ".]

l l 96l 62104/96l l C lTEC-nHlTEC-TEHj I OO'032 l 58 0% l 0,9H+ 0.00 l27.25]

l175lDNTlP *l l

i.

I 98) 62l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-0.42 l36.43l (182lDNTlP *l l

j l100l 62l04/96l l C lTEC-TEHlTEC-TEHl l00032l58bULl09H+ 0.00 l80.97l l176lDNTlP ;)

l j

l102l 62l04/96l l C lTEC-TEHjTEC-TEHl l00033l580ULl09H+

0.00 l25.94l

[182lDNTlP *l l

$~

l110] 62l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.06 l21.33l l186lDNTlP *l l

I l 91] 63l04/96l l C lTEC-TEHlTEC-TEHl l000331580ULl09H-0.22 l58.51l l181lDNTjP ;l l

l 93l o]O4/96l l C lnC-TEHlTEC-TEHI l00032l580ULl09u.

0.00 l88.48l il75 lDffrlP *-l l

l 95l 63l04/96l l C lTEC-TEHlTEC TEHl l00033l580ULl09H-0.03 l72.73l l186lDNTlP 1l l

l101l 63l04/96l l C lTEC-TEHlTEC-TFHj l00032l580ULl09H+ 0.00 l74.54l (175lDNTlP Ll l

l103l 43104/96) l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.25 l22.16l f183lDNTlP "l l

l105l 63l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+

0.00 l92.61l 4174lDNTlP *!

l l107l 63i04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+

0.03 l73.75l

'184lDNTlP Ll l

l127l 0 :04/96l l C lTEC-TEHlTEC-TEHl l00095l580ULl09H+

0.00 l 7.01l

'180lDNTlP *l l

l 92l 44sJ4/96l l C lTEC+TEHlTEC-TEHl l50033]S80ULl09H+. 0.09 l41.55l

'185lDNTlP 11 l

1 9(l e4 !04/96l l C lTEC-TEHlTEC TEHL l00032l580ULl09H+

0.00 l73.01l 175lCNTlP 1; l

l 98; %,04/96l l C lTEC-TEHlTEC-TEHj l00032j580ULl09H+

0.00 l13.92l 276lDNTlP ll l

l100l (4l04/96j lC lTEC TEHlTEC-TEHl l00033l580ULjo9H-0.03 l126.8l 182lDNTlP ll l02l 64104/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l55.31l '177lDNTlP ;( l 4 l204} (4104/96l lC lTEC-TEH]TEC-TEHl l00033l580ULl09H+ 0.03 l18.71l 179lDNTlP ;' l jl06l (4;04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l50.67l 176lDNTlP 1. l l 91l H t04/96l l C lTEC-TEHITEC-TEHl l00033l580utl09H+ 0.00 l21.13l 181lCNTjP, l l 93l f5104/96l l C [TEC-TEHlTEC-TEHl l000321580ULl09H+ 0.00 l39.971 175lDNTlP 1. l 4 l 97l fik04/96l lC lTEC-TEHlTEC-TEHl l00034l500ULl09H-0.06 l34.57l 182lDNTlP 1. l l 99l 65!04/96l lC lTEC-TEH]TEC-TEHl l00035l5800Lj09H+ 0.06 l72.14l 182lDNTlP _ l l101l *EiO4/96l lC lTEC-TEHlTEC-TEHl l00034l5800Ll09H+ 0.00 l62.49l 382lDNTlP ;! l 1103l e<104/961 l C lTEC-TEHlTEc-TEHI l00035l580VLl09H+ 0.03 l55.38l 180lCNT{e ti l ]105l 45!04/96l lC lTEC-TEHlTEC-TEHl l00034l580VLl09H+ 0.00 l67.24l 181lDNTlP

  • I l

5 l 92l H!O4/96l l C lTEC-TEHlTEC-TEHj l00035l580ULl09H. 0.09 l35.32l. 184 lD?rrj P '. ! l l 94l isiO4/96l l C [TEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.00 l 7.91l 182lDNTlP ll l l 98l Eij04/96l l C lTEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.09 l22.41l 191lDNTlP ;! l l100l H !04/96l j C lTEC-TEHlTEC-TEHl l00035l580ULl09H+ 0.03 l56.42l .284lDNTlP ;! } l102l 66104/96l l C lTEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.06 l 6.48l 100lDNTlP Li { l 93l 67]C4/96l l C lTEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.00 l50.49l 182lDNTlP ;! l l 95l 67iO4/96l l C lTEC-TEHlTEC TEHj l00035l580ULl09H+ 0.03 l54.74l ,184lDNTlP Li l l 97l 67l04/96l l C lTEC-TEHlTEC-TEHj l00034l5800Ljo9H+ 0.00 l15.19l

179lDNTlP ;j l

l 99l 67104/96l l C lTEC-TEHjTEC-TEHl-l00035l580ULl09H+ 0.06 l32.67l 183lDNTlr - l l103] 67l04/96l l C lTEC-TEHITEC-TEHI l00035l580ULl09H+ 0.06 l15.27l 4287]DNTIP -l l 1105l U l04/96) l C lTEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.00 l22.78l 182lDNTlP *! l } M l 65104/96l l C lTEC-TEHlTEC-TEHj l00035l580ULj09H-0.03 !36.29l

184lDNTlP *l l

j 941 41:04/96l l C lTEC-TEHjTEC-TEHj l00034l580ULl09H-0.18 l29.67l 1181lDNTlP *-l l 1100l sei m 96l l C lTEC-TEHITEC-TEHI l00035lSe0ULl09H+ 0.03 l38.09l 4184lDNTlP *l [ l 911 6i104/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H-0.09 l45.29l !183lDNTlP Li l l_l _! 1 L_.I l l ___ l l l l _.- ___. I _ L___, ___ I ROCKRIDGE TECHNOLOGIES

1 CUMULATIVE REPORT 04/96, EGE, CALVERT CLIFFS, UNIT 1 STEAM GENLTATOR 11 PAGE: 6 CF 15 'OtfrAGE DATA SET CURRENT DATER 06/06/96 SELECT *CN VARIABLES: Indication Location, Percent TIMT;: 03:57:17 I l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lL*Nl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGj ) l_ l _I I l_ _l I l_I I I I l _ l _ I_.l _ l l l 93l f9l04/96l l C lTEC-TEHlTEC-TEHj l00034]580ULl09H-0.12 l43.97l l181lDNrlP 1l l j l 95l ("vl04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H+ 0.00 l63.37l l183lDNTlP lj l l 97l f9l04/96l l C lTEC-TEHlTEC-TEHl l00034l5800Ll09H+ 0.00 l24.43l l183lDNTlP 1l l l 99l f9l04/96l l C lTEC-TEHlTEC-TEHl l 00035 l 580ULl 0,9H+ 0.15 l51.11l l182lDNTlP 1l l l 92l 70l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H+ 0.06 l29.33l l177lDNTlP 1l l l 94] 70l04/96l l C lTEC-TEHlTEC-TEHj l00036l5BDULl09H+ 0.20 l34.44l l178lDNTlP 1l l l 96l ~0l04/96l l C lTEC-TEHjTEC-TEHl l00035l580ULl09H+ 0.27 l10.90] l184lDNTlP 1l l { l 98l *;f04/96l l C lTEC-TEHlTEC-TEHj l00130l580ULlC9H+ 0.00 l67.57l l180lDNTlP li l l100l "Oj04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H-0.03 l49.54l l184lDNTlP 1l l l102l ";l04/96l l C lTEC TEHlTEC-TEHl l00130j580ULl09E+ 0.00 l56.69l l201lDNTlP 1l l l 91l 7l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H-0.03 l 8.71l l184lDNTlP 1l l l 93j *;l04/96l l C lTEC-TEHlTEC-TEHj l00036l580ULl09H-0.03 l38.78l l179lDNTlP 1l l { l 95l ** l04/96l l C lTEC-TEHlTEC-TEHj l00037l580ULl09H+ 0.06 l 41'. 36 l l178lDNTlP 1l l l 97; '"!04/96l lC lTEC-TEHlTEC-TEHl l 99) ^;iO4/96l l C lTE'*-TEHlTEC-TEHl. l00036l580ULl09H+ 0.C0 l21.61l l179lDNTlP 1l l l00037l580ULl09H+. 0.20 l31.61l l177lDNTlP lj l l101l ';104/96l l C lTEC-TEHlTEC-TEHl l00036l580ULl09H+ 0.00 l69.86l l176lDNTlP 1l [ I l101l ";jo4/96l l C lTEC-TEHjTEC-TEHj l00036l580ULl09H+ 0.00 l 5.16l l180lDNTlP 1l l l 92l 2!04/96l l C lTEC-TEHlTEC-1EHl l00037l580ULl09H-0.09 l36.12l l178lDNTlP 1l l l 96l '2jo4/96l l C lTEC-TEHlTEC-TEHl l0CO37l580ULl09H. 0.;3 l 8.60l }178lDNTlP ll l l 96l ~2104/96j l C lTEC-TEHlTEC-TEHl [00036l580ULjo9H-0.16 l94.53l l179lDNTjP 1l l l100j 7104 /96 l l C lTEC-TEHlTEC-TEHl l0CO37l580ULl09H+ 0.26 l58.00l l178lDNTlP 1l l l102; ~ ~. i O 4 / 9 6 l l C lTEC-TEHlTEC-TEHj l00036l580ULl09He 0.00 l43.10l l179lDNTlP 1l l l104L ~;iO4/96l lC lTEC-TEHlTEC TEHl !00037l5800Ll09H-0.C3 l32.94l l178lDNTlP 1l l l110! 2 5 04/96l l C lTEC-TEHlTEC-TEHl l00036l580ULl09H+ 0.00 l10.35l l179lDNTlP 1l l j 91! i;04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H+ 0.06 l34.10l l177lDNTjP 1l l l 93} ~3!04/96l lC lTEC-TEHjTEC-TEHl l00036l580ULl09H+ 0.03 l76.41l l178lDNTjP 1l l l 951 ~3jo4/96l l C lTEC-TEHlTEC TEdl l00037l580ULl09H+ 0.09 l29.10l l178lDNTlP 1l l l 971 '!04/96l l C lTEC-TEHjTEC-TEHj l0CO36l580ULic9H+ 0.06 l81.87l l178lDNTlP 1l l l 99l

04/96l lC lTEC-TEHlTEC-TEHj l0
337l580ULl09H+

0.12 l43.83l l183lDNTlP 1l l' l 92l 4104/96l l C lTEC-TEHjTEC-TEHj l00040l5800Ll09H+ 0.03 l49.96l l176lDNTjP ll l l 94l ~4!04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.09 l20.93l l179lDNTlP 1l l l102! "4104/96l l C lTEC-TEHlTEC-TEHl l0003Bl580ULl09H+ 0.00 l14.16] l180lDNTlP ll l q l 911 5104/96l l C lTEC-TEHjTEC-TEHl l00040l5800Ll09H+ 0.00 l56.19l l182lDNTlP 1l l l 93l i104/96l lC lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.00 l 8.01l l180lDNTlP 1l l l 95) "I104/96l l C lTEC-TEHlTEC-TEHl l00039l580ULjo9H+ 0.09 l43.31l l183lDNTlP 1l l l 99l '!l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H+ 0.15 l29.08l l182lDNTlP 1l l ) l 921 'f)04/96l l C lTEC-TEHjTEC-TEHj l00040l580ULjo9H-0.15 l12.11l l177lDNTjP 1l l { l 94l ~fl04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H-0.03 l68.61l l179lDNTlP 1l l l 961 *f104/96l l C lTEC-TEHlTEC-TEHj l00039l5800Ll09H+ 0.00 l29.86l l181lDNTlP 1l l l110l *fl04/96l l C lTEC-TEHlTEC-TEHj l00038l580ULl09H+ 0.00 l17.82] l178lDNTlP 1l l l 91l "l04/96l l C lTEC-TEHlTEC-TEHj l00040l580ULl09H-0.09 l25,38] l179lDNTlP 1l j j 93l N 104/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H-0.15 l33.87] l183lDNTlP 1l l l 95l ~~l04/96l l C lTEC.TEHlTEC-TEHj l00038l580ULl09H-0.06 l58.60l l175lDNTlP 1l l l 97l "l04/96l lC lTEC-TEHlTEC-TEHl l00039l580ULl09He 0.09 l95.48l l177lDNTlP ll l l 99l "l04/96l l C lTEC-TCHlTEC-TEHj l00038l580ULl09H-0.21 l29.81l l177lDFflP 1l l l_._ l __ i l j _l l 1_. l l l l l__ I_ l_l._ i_ l ROCKRIDGE TECHNOLOGIES

~ CUMULATIVE REPORT 04/96. BCE, CALVERT C11 FPS, IMIT 1 STEAM CENERATOR 11 PAGE: 7 OP 15 CITTACE DATA SET CURRENT DATE: 06/06/96 SELECTICN *."ARIABLESr Indication Location, Percent TIME: 03:57:17 l l l EXAM l l l E)AM EXTENT l l l l l l iROWlLINI OATEl HEAT 8jLEGlPRUGRAMl ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l _l_ J l l __ l 1 1 _l i I I L l _l_._l_ ! 1 !- 92l 78l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.03 l41.63l l178lDNTlP lj l 1 94l 78104/96l l C lTEC-TEHlTEC-TEHj l00039l5800Ll09H+ 0.00 l39.01] l180lDNTlP 1l l

96) 78l04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+

0.06 l13.65l l1'2lDNTlP 1l l

100l 78104/96l l C lTEC-TEHjrEC-TEHj l 00'03 9 l 580ULl 0pH-0.03 l33.531 l181lDerrlP 1l l

1102l 78l04/96l l C lTEC-TEHjTEC-TEHl l00038l580ULl09H+ 0.06 l26.32l l181lDNTlP 1l l j 91l*)9l04/96l l C lTEC-TEHlTEC-TEHl l00040l58hULl09H+ 0.00 l38.45l l179lDNTlP 1l l ' 93l 79104/96l l C lTEC-TEHlTEC-TEHj l000401580ULl09H-0.06 l55.30l l176lDNTlP 1l l 95} 79;04/96l l C lTEC-TEHlTEC-TEHj l00039l5800Ll09H+ 0.00 l70.401 l179lDNTlP lj l

97) 79:04/96l l C lTEC-TEHlTEC-TEHl jo0038l580ULl09H-0.12 l93.55l l171lDNTlP 1l l

99] 79,04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.00 l23.27l l182lDNTlP 1l l 101l 79l04/96l l C lTEC-TEHlTEC-TEHl l00036l580ULl09H-0.27 l24.95l l174lDNTlP1l j 92] 80 04/96l l C lTEC-TEHjTEC-TEHj l00040l580ULl09H-0.06 l47.55l l178lDNTlP 1l l 94l 80 04/96l l C lTEC-TEHjTEC-TEHj l00039]S80ULl09H-0.21 l 5 8 '. 91 l l181lDNTlP 1l l 96l 80 04/96l l C lTEC-TEHlTEC-TEN) l00039l580ULl09H. 0.03 l63.18l ,'179lDNTlP 1l l 100l 80 04/96l l C lTEC-TEHlTEC-TEH, l00039l580ULl09H+ 0.00 l 5.09l l179lDNTjP 1l l 102) 60 04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.09 l 9.19l l173lDNTlP 1l l 91l 81 C4/96l l C lTEC-TEHlTEC-TEH! l00040l580ULl09H+ 0.06 l25.85l l180lDNTlP 1l l 95l 81 C4/96l l C lTEC-TEHlTEC-TEHl l00039l580VLl09H+ 0.00 l117.7l !177lDNTlP 1l l 97l 81 04/96] l C lTEC-TEHlTEC-TEHl l00038l580ULl09H-0.03 l98.93l l171lDNTjP 1l l 99l 81 04/96l l C ' NC-TEHlTEC-TEHj l00039l5800Ll09H+ 0.00 l60.88l l181lDNTlP 1l l 101l 81 04/96l' l C lTEC MEHlTEC-TEHi l00038l580ULl09H-0.15 l24,56l l 174 l DN"'l P 1 l l 92l 82 04/96l l C jTEC-TEHl'1EC TEH j l00040l580ULl09H-0.12 l24.82l 1172lDNTlP 1l l 94l 82 C4/06l I J l TEC-TEH l TEC-TEH j l00039l580ULl09H+ 0.00 l84.05l l179lDNTlP 1l l 96] 82 04/96l l C iTEC-TEHlTEC-TEH; lc00391580unl09H+ 0.00 1157.9l l176lDNTlP lj l 98] 62 04/96l l C lTEC-TEHjTEC-TEH! jo003Bl580ULl09H+ 0.06 l101.1l l173lDNTlP 1l j j 100l 82 04/96l } C lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.09 l149.2l l176lDNTlP 11 l 102l 82 C./96l } C lTEC-TEHlTEC-TEHj l00038l5BOULl09H+ 0.03 l24.41l 1176lDNTlP 1l l { 104l 82 C4/96l l C lTEC-TEHlTEC-TEHI l00039l580ULl09H+ 0.09 l12.82l l182lDNTlP 1l l 208l e2 c4/96l l C lTEC-TEHlTEC-TEHj l00039l5800Ll09H+ 0.09 l75.75l 1179lDNTlP 1l l 110 l 8 2 ' 0 4 /96 l l C ltEC-TEHlTEC-TEHj l00038l580ULl09H+ 0.03 l11.60l l177lDNTlP 1l l 91l 83:04/96l l C lTEC-TEHjTEC-TEN] l00040l5800Ll09H+ 0.06 l31.24l 1180lDNTlP 1l l 95l 83 c4/961 i C [TEC-TEHITEC-TEHl l000391580ULl09H+ 0.00 l70.80l l180lDNTlP 1l l 97l 83iO4/96] l C lTEC-TEHlTEC-TEHj l00038l580ULl09H+ 0.00 {184.8l l167lDNTjP 1l l 99l 83'04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.00 l108.Bl {180lDNTlP lj l ( 101] 83'04/96l lC lTEC-TEHlTEC-TEHl l00038l500ULl09H-0.12 l51.72l l173lDNTlP 1l l 105] 83'04/96l lC lTEC-TEHlTEC-TEHl l00038l580ULl09H+ 0.09 l23.00l l178lDNTlP 1l l { 94l 64 04/96l l C lTEC-TEHlTEC-TEHl l 0013 0 l 580Ur l' n1+ 0.00 l27.49l l182lDNTlP 1l l 96l 84 04/96l j C lTEC-TEHlTEC-TEHl l00038l5s0ULl09H+ 0.00 l82.60] l179lDNTlP 1l l 100l 84:04/96l l C lTEC-TEHlTEC-TEH[ l00038l580ULl09H+ 0.06 l85.50l l173lDNTlP 1l l ( 102l 84 04/96l lC lTEC-TEHlTEC-TEH} l00130l580ULl09H+ 0.00 l20.18l l181lDNTjP 1l l 104l 84.04/96l l C lTEC-TEHlTEC-TEHj l00038l580ULl09H-0.15 l 6.29l l174lDNTlP 1l l 108) 84'04/96{ l C jTEC-TCHlTEC-TEHi l00038l580ULl09H-0.18 l44.43] l175lDNTlP 1l l 110l 84:04/96l l C lTEC-TEHlTEC-TEHl l00130l580ULl09H+ 0.00 l41.49] l182lDNTlP 1l l

93) 85 04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H-0.29 l62.52l l176lDNTlP 1l l

3 95l 85 04/96l l C lTEC-TEHlTEC-TEHj l00087l5800Ll09H+ 0.03 l54.19l l1*'0lDNTlP lj l _l_ l l_l l L_ I I I I L._. l _ l_ I _ L._ _ I ROCTJtIDGE TECHNOLOGIES

w

m CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 I STEAM GENERATOR 11 PAGE: 8 OF 15 OtJfAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIML 03:57:17 i l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl CATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL lF ET6l;4 CATION l VOLTS lMM.lDEGl t lCH lCHNGl l_l_I I i_i i I_l I i_ i L_l._i_l_ ]._ l l 97l 85l04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H-0.12 l81.59l l176lDNTlP ll l l 99l 85l04/96l l C lTEC-TEHlTEC-TEHj l00087l580UM N H+ 0.00 l86.28l l171lDNTjP 1l ~ l l101l 85j04/96l l C lTEC-TEHlTEC-TEHl j00088l5NULl09H- 0.12 l15.44l l175lDNTlP 1l l l103] 85l04/96l l C lTEC-TEHlTEC-TEHj l 0 0087 ' 58 0ULl 0,9H+ 0.06 l27.77l l176lDNTlP 1l l l107l 85l04/96l l C lTEC-TEHlTEC-TEHl l 0008 *, l 5 8 0UL l 09H- 0.03 l32.67l l174lDNTlP 1l l i l109l 85l04/96l l C lTEC-TEHlTEC-TEHl l 00088 l581ULj 09t!- 0.06 l44.37l l176lDNTlP 1l l l115\\ 85l04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09H+ 0.17 l 8.96l l172lDNTlP 1l l l j 92l'86l04/96l lC lTEC-TEhlTEC-TEHj l00087l580VLl09H+ 0.06 l54.93l l173lDNTjP 1l l l 94l 86l04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.03 l130.1) l173lDNTlP 1l l l 96l 86l04/96} l C lTEC-TEHlTEC TEHl jo0087l580ULl09H+ 0.03 [78.67l l172lDNTlP 1l l l 98l 86l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 l70.09l l175lDNTlP'll l l100) 86l04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.00 l37.97l l174lDNTlP 1l l l102l 86l04/96l lC lTEC TEHlTEC-TEHl l00088l5800Ll09H-0.09 l27.27l l174lDNTlP 1l l l104l 86l04/96l l

  • lTEC-TEHjTEC-TEHl l00087l580ULl09H-0.06 l42.63l 1173lDNTlP 1l l

l106l 86l04/96l lC lTEC-TEHlTEC-TEHl l00088l500ULl09H+ 0.06 l56.82l (176lDNTlP lj l l105l 86l04/96I l C lTEC-TEHlTEC-TEHl l00087l5800Ll09H+ 0.00 l$1.26l !178lDNTlP 1l l { l110j 86l04/96l lC lTEC-TEHlTEC-TEHl l00088l5800Ll09H+ 0.30 l33.82) !179lDNTlP lj l l114l 8(l04/96! j C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.30 l45.92l '176lDNTlP 1l l l116l 86l04/96i l C lTEC TEHlTEC-TEHj l00087l580ULl09H+ 0.09 l16.23l l175lDNTlP 1l l l 91] 87l04/96l l C lTEC-TEHjTEC-TEHl l00087l580VLl09E. 0.03 l66.38l !172lDNTlP 1l l l 93l 87l04/96) l C lTEC-TEHlTEC-TEHl l00088l580ULl09H. 0.03 l122.7) f175lDNTlP 1l l } 95l 87l04/96! lC lTEC-TEH)TEC-TEHl l00087l580ULl09H+ 0.03 l128.9l '170lDNTlP 1l l ] 97l 87l04/966 lC lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.12 l118.0l 175lDNTlP 1l l l l 99l 87l04/96' } C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.12 l118.0l f172]DNTlP lj l l103l 87l04/96.! l C'lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 157.3Bl il73lDMTlP 1l l l105l 87l04/96! l C lTEC-TEHlTEC-TEHl l00088l580ULl09H-0.12 l108.5l l176lDNTlP 1l l l107l 87l04/96l l C lTEC-TEH]TEC-TEH] l00087j580ULl09H-0.18 l13.19l 171lDNTlP 1l l l109l 87l04/961 lC lTEC-TEHjTEC-TEHl l00088]580ULl09H+ 0.03 l21.32) !177lDNTlP 1l l l 92l 88l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.03 l37.63) 7173lDNTlP 1l l l 94l f8l04/96l lC lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.03 l128.0l

  • 170lDNTlP'1l l

l 96l 88l04/96i lC lTEC-TEHlTEC-TEH} [00088l580ULl09H-0.03 l129.8) !174lDNTlP 1l l l 98[ 88l04/96l lC lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.06 l53.58l !175lDNTlP 1l l l100l 88]C4/961 lC lTEC-TEHlTEC-TEHl l00088l500ULl09H+ 0.12 l50.24l 1178lDNTjP 1l l l114l 88l04/96i l C lTEC TEHlTEC-TEHj l00088l580ULl09H-0.03 l59.79) '175lDNTlP 1l l ] l118l 88l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l 9.61) !181lDNTlP 1l l l 91l 99l04/96,' lC lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.00 l46.40l f179lDNTlP 1l l l 93l 89l04/96! l C lTEC-TEHlTEC-TEHl l00088l580ULl09H-0.03 l95.65l !174lDNTlP 1l l l 95l 89l04/96! l C lTEC-TEHlTEC-TEHl l00087l580ULl09H. 0.00 l84.09l 1171lDNTlP 1l l l 97l 89l04/96l l C lTEC-TEHjTEC-TEHj l00088l580ULl09H+ 0.00 l91.57l il75lDNTlP 1l l l101l 89l04/961 lC lTEC-TEHlTEC-TEHj l00088l580ULl09H. 0.18 l18.68l !176lDNTjP 1l l l103l 89l04/96; l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.15 l E.10l f176lDNTlP 1l l l105l 89l04/96l lC lTEC-TEHlTEC-TEHj l00088l580UL]D9H+ 0.00 l10.39l 1182lDNTlP 1l l l1091 89l04/96l l C jTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.27 l11.85l 1175lDNTlP 1l l l113l 89l04/96! l C lTEC-TEHlTEC-TEHl l00088l580ULl09H- 0.21 l14.11l il74lDNTlP 1] l l119l 89l04/965 lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.03 l24.64l {173lDNTlP 1l l !_I_I 1 l_ L. I ! _l l i I L._:_ l _ i _ I _ I ROCKRIDGE TECHNOLOGIES

- ~ l CUMULATIVE REPORT l 04/96, BGE, CALVERT CLIFFS, UNIT 1 I STEAM GENERATOR 11 PAGE: 9 CF 15 OtJTAGE DATA SET CURRENT DATE: 06/06/96 l SELECTION VARIABLES: Indication Location, Percent TIME: 03:57:17 l l l EXAM l l l rXAM EXTENT l l l l l l l l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE lLOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l _L I I L_I I l_1 I I I l_ L._I_ L._I_ _l l 92l 90l04/96l l C lTEC-TEHjTEC-TEHl l 00087 l 580ULl09H- 0.03 l39.98l l171lDNTlP 1l l l l 94l 90l04/96l l C lTEC-TEHlTEC-TEHl l00088l500ULl09H+ 0.12 l30.80l-l175lDNTlP 1l j l 96l 90j04/96) lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l63.73l l178lDNTlP 1l l l 98] 90l04/96l l C lTEC-TEHjTEC-TEHl l C 0h98 l 580UL j o,9H+ 0.00 l12.13l l182lDNTlP 1l l l100l 90l04/96l lC lTEC-TEHjTEC-TEHl lC0100l580ULl09H+ 0.00 l29.00l l181lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TSHl l00087l58bULl09H+ 0.03 l27.74l l173lDNTlP 1l l l102l 90l04/96l lC lTEC-TEHlTEC-TEHl lC0088l580ULl09H+ 0.21 l19.19l l173lDNTlP lj l l110l 90l04/96l l C lTEC-TEHlTEC-TEHl l C 008 8 l 5 800Ll 0'9H+0.15 l18.23l l177lDNTlP 1l l l114l 90l04/96l lC lTEC-TEHlTEC-TEHj l00088l5800Ll09H+ 0.18 l17.03l l175lDNTlP 1l l l 91l 91l04/96l l C jTEC-TEHlTEC-TEHj lC0087l580ULl09H+ 0.00 l42.09l l178lDFTlP 1l l l 93l 91l04/96l lC lTEC-TEHjTEC-TEHl lC0088l580ULl09H+ 0.27 l49.99l l175lDNTlP".l l l 95l 91l04/96l l C lTEC-TEHjTEC-TEHl l C 0087 l 580ULl 09H-0.03 l21.36[ l173lDNTlP1l l ( 97l 91l04/96l lC lTEC-TEHlTEC TEH! l C 008 8 l580ULl 09H+ 0.21 l48.31l l174lDNTlP 1l l l 99l 91l04/96l lC lTEC-TEHlTEC-TEHj [00087l5800L]O9H+ 0.09 l42.50l l1751DNTlP 1l l l103l 91l04/96j l C lTEC-TEHjTEC-TEHl l 0387l5800L}09H+ 0.00 l10.82l l178lDWTlP 1l l I l109l 91l04/96l lC lTEC.TEHlTEC TEHj lC0088l500ULl09H+ 0.12 l20.97l l176lDNTlP 1l l l 92l 92l04/96l lC lTEC-TEHlTEC-TEHj l 0087l580ULl09H+ 0.06 l108.2l l168lDNTlP 1l l l 94] 92l04/96l lC lTEC-TEHlTEC-TEHj l: 0 088 l 5 8 0ULl 09H+ 0,00 l 55.4 9 l l175lDNTlP 1l l l 96l 92l04/96l [C {TEC-TEHlTEC-TEHj l0:087l580ULl09H-0.09 l60.05] l172lDNTjP 1l l l 98l 92l04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.15 l31.81l l175lDNTlP 1l l l200l 92l04/96l lC lTEC-TEHlTEC-TEHl l : 0 087 l5800L; 0 9H+ 0.09 j42.25] l174lDNTlP 1l l l106l 92l04/96l lC lTEC-TEHlTEC-TEHl l 0088]S60ULl09H+ 0.15 l49.15l l176lDNTlP lj l l110j 92l04/96l lC lTEC-TEHlTEC-TEH[ l:0088l580ULl09H- 0.21 l24.37l l176lDNTlP 1l l l 91l 93l04/96l lC lTEC-TEHlTEC-TEHl l0:087l580ULl09H, 0.00 l31.56l l174lDNTlP 1l l l 93l 93l04/96l lC lTEC-TEHlTEC-TEHl (00088l5800Ll09H-0.03 l46.12l l175lDNTlP 1l l l 95l 93l04/96l lC lTEC-TEHlTEC-TEHl l0 087l580ULl09H+ 0.03 l56.33l l173lDNTlP 1l l l 97l 93l04/96l lC lTEC-TEHlTEC-TEHl l:20861580ULl09H+ 0.09 l)5.64l l176lDNTlP 1l l l 99] 93l04/96l lC lTEC-TEHlTEC-TEHl l ~ 08 7l 5 80ULl 09H-3.15 l14.72) l171]DNTlP 1l l l103l 93l04/96l lC lTEC TEHlTEC-TEH) l~2087l580ULl09H- 0.29 l 8.03l l178lDNTlP 1l l jl07l 93l04/96l lC lTEC-TEHlTEC-TEHl l0*087l580ULjo9H+ 0.09 l30.82l l174lDNTlP 1l l l109l 93l04/96l lC lTEC-TEHlTEC-TEHl l 0 08 8 l 58 0ULl 09H+ 0.21 l33.05l l175]DNTIP 1l l l 94l 94l04/96} lC lTEC-TEHlTEC-TEHl lC0008l580ULl09H- 0.15 l16.05l l176lDNTlP 1l l ) j 96l 94l04/96l l C lTEC-TEHjTEC-TEHl l 0087l5BOULl09H+ 0.03 l58.10l l173lDNTlP 1l l l102] 94l04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.12 l15.06l l176lDNTjPlj l l104] 94l04/96l lC lTEC-TEHlTEC-TEH[ l00087l580ULl09H+ 0.00 l43.91l l175lDNTjP 1l l l106l 94l04/96l lC lTEC TEHlTEC-TEHl lC0088l500ULl09H+ 0.09 l73.51l l175lDNTlP lj l l108l 94l04/96l lC lTEC-TEHlTEC-TEHl l 0087l580ULl09H+ 0.03 l39.02] l174lDNTlP 1l l [110l 94l04/96l lC lTEC-TEHlTEC-TEHl {00088]580ULl09H-0.12 l18.19l l176lDNTlP 1l 8 q l118l 94l04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl10H-0.06 l65.85l l175lDNTlP 1l l 1 l 91l 95l04/96l lC lTEC-TEHlTEC-TEHl lC 087l580ULl09H-0.03 l27.18l l172lDNTlP lj l l 93l 95l04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.03 l97.89l l175lDNTlP1l l l 95l 95l04/96l l C lTEC-TEHlTEC-TEHl lC?087l580ULl09H. 0.06 l39.79l l173lDNTlP 1l l .l 97l 95l04/96l lC lTEC-TEHlTEC-TEHl lC0088l580ULl09H+ 0.00 l101.4l l173lDNTlP 1l l l 99l 95l04/96l l C lTEC-TEHlTEC-TEHj l 0 0087 l 580ULl 09H+ 0.00 l62.42l l178lDNTlP 1l l l101l 95l04/96l lC lTEC-TEHlTEC-TEHl l000881580ULl09H+ 0.15 l34.98l l175lDNTlP 1l l l_l. _i I L_ I I l __ f I I I L _ I _ L_ l__ I _ l ROCK 7tIDGE TECHNOLOGIES i

.m __m m CUMULATIVE REPOR? 00/96, BGE, CaLVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 10 OF 15 OUTAGE DATA SET 1 CURRENT 3 DATE: 06/06/96 SELECTION VARIABLES: Indication Locataan, Percent TIME: 03:57:17 l l l EXAM l l l EXAM EXTENT l l l l l l jROWlLINl DATEl HEAT #[ LEG lPROGRAMj ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHtt3 l L_ l -- I I l_1 l L_I I I I L_. l ___ L_ I_1.__ l l103l 95l04/96l l C lTEC-TEHjTEC-TEHj l00087l580ULl09H+ 0.00 l 62. 04 l. l172lDNTlP 1l l l107j 95l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULj09H. 0.03 l31.30l l171lDNTlP 1l l l109l 95l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.09 l14.17l l173lDNTlP 1l l 4 l117l 95l04/96l l C lTEC-TEHjTEC-TEHl l00b8Bj580ULl10H+ 0.00 l84.17l l173lDNTlP 1l l l119l 95l04/96l l C lTEC-TEHlTEC-TEHl l00087l5800Ll10H+ 0.00 l 9.48] l175lDNTlP 1l l l 92l 96l04/96l l C lTEC-TEHlTEC-TEHl l00087l58tULl09H-0.06 l24.53l l173lDNTlP 1l l l 94[ 96l04/96] l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 l55.49l l182lDNTlP 1l l l 96l 96l04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09H-0.09 l88.42l l170lDNTlP 1l l l100l 96l04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H-0.06 l 5.33l l173lDNTlP 1l l l108l 96l04/96l l C lTEC-TEHjTEC-TEHl l 00087 l 580ULl 09ti+ 0.00 l47.54l 1174lDNTlP 1l l l110l 96l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0 06 l24.14l !;76lDNTlP 1l l l118l 96l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l19.20l l;81lDNTlP lj l l128) 96l04/96l l C lTEC-TEHlTEC-TEHl l00089l580ULl09H+ 0.23 l 5.09l !" 80lDNTlP 1l l l 91l 97l04/96l l C lTEC-TEHlTEC-TEHl l00087j580ULl09H+ 0.03 l31.82l i;76lDNTlP 1l l l 93l 97l04/96l l C iTEC-TEHlTEC-TEHl l00088l580VLl09H-0.06 l94.63l 174lDNTlP 1l l l 951 97l04/96l lC lTEC TEHlTEC-TEHl l00087l580ULl09H+ 0.03 l82.41l ,174lDNTlP 1l l l 97) 97l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.06 l142.1l I;72lDNTlP 1l l l 99l 97l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0,00 l66.01l 176lDNTlP 1] l l107l 97l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULj09H-0.03 l 5.67l ';74lDNTlP 1l l l109l 97l04/96l l C lTEC-TEHlTEC-TEHl 'l00088l580ULl09H-0.06 l63.58l 1174lDrGlP 1l l l 92l 98l04/96l lC lTEC-TEHlTEC-TEHj l00078l5800Ll09H-0.09 l30.61l I;76lDNTlP ll l l l l04/96l lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.03 l32.98l l"_74lDtGlP 1l l l 94l 98l04/961 l C !!EC-TEHlTEC-TEHl l00084l560ULl09H+ 0.21 l37.56l 75lDNTlP 1l l l 96l 96l04/96l l C lTEC-TCHlTEC-TEHj l00087l580ULl09H-0.12 l106.3l ,;69lDNTlP 1l l l 98l 98l04/96l l C lTEC-TEHlTEC-TEHj l00088l5800Ll09H+ 0,00 l78.68l ,.81lDt3lP 1l l l100] 98l04/96l lC l TEC-TEU lTEC-TEH l l00087l5a00Ll09H+ 0.00 l11.52l l173lDNTlP 1l l l102l 9el04/96l l C lTEC-TEHlTEC-TEHl l00388l580VLl09H+ 0.03 l27.81l l176lDNTlP 1l l l110l 98l04/96l lC lTEC-TEHlTEC-TEHl l0C088l580ULl09H+ 0.15 l21.27l !;75]DNTlP 1l l l 91{ 99l04/961 l C lTEC-TEHjTEC-TEHj l00087l580ULl09H-0.03 l41.80l {;76lDNTlP 1l l l 93l 99l04/96[ l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.00 l62.25l i"81lDNTlP 1l l l 95l 99]C4/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.06 l22.28l i;73lDNTlP 1l l l 97l 99l04/96[ l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0,00 l74.53l 1"BllDNTlP 11 l l 99l 99l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.12 l98.71l I;73lDNTlP 1l l l101l 99l04/96l l C lTEC-TEHlTEC-TEHl l00088l5800Ll09H+ 0.03 l34.41l !;76lDNTlP 1l l l105l 99l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULj09H+ 0.00 l28.30l l*76lDNTlP ll l l107l 99l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.06 l26.54l l.73lDNTlP 1l l l117j 99l04/96j l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l25.61l ]*82lDNTlP 1l l l119) 99l04/96l l C lTEC-TEHlTEC-TEHl l00087j580ULl10H+ 0.12 l 6.08l I;73lDNTlP 1l l l121l 99l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l 5.97l l1BOlDNTlP 1l l l 92l100l04/96l lC lTEC-TEHlTEC-TEHj l00087l5800Ll09H-0.06 l17.09l !;73lDNTlP 1l l l 94l100l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 l14.88l l182lDNTlP 1] l l 96l100l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.06 l55.73l l;74lDNTlP 1l l l100l100l04/96l l C lTEC-TEHjTEC-TEHj l000871580ULjo9H+ 0.00 l76.79l l180lDNTlP 1l l l102l100j04/961 l C lTEC-TEHlTEC-TEHj l00088l5800Ll09H+ 0.00 l82.99l l;81lDNTlP 1l l l104(10Dl04/96l lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l17,62l I;76lDNTlP 1l l L_ I_ I L__ l I l_I I I I L ' __ L_ I ___ L_._ I ROCKRIDGE TECHNOLOGIES

i CUMULATIVE REPORT 04/96, BCE, CALUERT CLIFFS, UNIT 1 I STEAM GENERATOR

11 PAGE: 11 OP 15 OLTTAGE DATA SET CURRENT DATE:

06/06/96 ) SELECTION VARIABLES: Indication Locat. ion, Percent TIMEi 03:57:17 { l l l ExAMI I l EXAM EXTENT l l l l l l l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL]EXPl CAL l PROBE l IsDCATION jVOLTSjMILlDEGl t lCH lCHNGl l__ l._ l l l_ ! l l_l l l l _ _l_ l_.l__I__l l l108l100l04/961 l C lTEC-TEHITEC-nHl l00087l580UL109H+ 0.00 l37.50l l181lDNTlP 1l l l118l100104/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl10H+ 0.00 l21.9tl l181lDNTlP1l l l l 91l101l04/96l l C lTEC-TFHlTEC-TEHl l00087l580ULl09H+ 0.00 l17.06] l175lDNTlP 1l l l 931101l04/96l l C lTEC-TEHlTEC-TEHl l0dO88l580ULjo9H+ 0.00 l78.98l l176lDNTlP lj l j l 951101104/96l l C lTEC-TEHlTEC TEH) l00087l580ULl09H+ 0.00 l68.32l l171lDNTIP 1l l 1 97l101l04/96l l C lTEC TEHITEC-TEH] l00088lSt0ULl09H+ 0.00 153.12l l180lDNTIP ll l l 99l101l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H- 0.24 l113.1l l171lDNTlP1l l .l101l101l04/96l. l C lTEC-TEHlTEC-TEHl l00088l580ULld9H+ 0.00 lR9.07l l175lDNTlP 1l l l103l101l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H- 0.18 ls1.92) l172lDNTlP 1l l l105l101104/96l 1 C lnC-TEHITEC-TEHI l00088l580usl0nt. 0.00 l34.041 1182lDNTlP2i l 1107l101104/96i l C lTEC-TEHlTEC-TEHI l00087l580usl09H+ 0.00 157.83l l 178 lDNTl P -1 l l !121i101104/96l l C lnC-nHlnC-nHl l00088l580ULl10H+ 0.00 l33.82l l182lDNT[P 1l l l127!101l04/96l l C lTEC-TEHlTEC-TEHl l00091l580DLl10H-0.06 l 6.54l {181lDNTlP 1l l l 921 02l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l38.08) l179lDNTlP 1l l l 94i102l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.06 !68.77l jl74lDNTlP 1l l l 96l102l04/S6l l C lTEC TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l49.30l l178lDNTlP 1l l l 98(102l04/9Gl l C lTEC-TEHlTEC-TEHj l00088]580ULl09H+ 0.00 l93.78l l181lDNTlP 1l l l100!102j04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.06 l71.89l l171lDNTlP 1l-l 1102:102l04/96l l C lTEC-nHlTEC-nHl l00088l580ucl09H. 0.00 1119.0l l174lDNTlP 1l l l106l102l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULj09H+ 0.00 l46.87l l174lDNTlP 1l l 1122;102l04/96l lC l REC-nHlnC TEHl l00088l580uL110H+ 0.00 l13.79] l180lDNTIP 1l l l 91f103l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l43.07j l181lDNTlP ll l l 93i103l04/96l l C lTEC-TEHjTEC-TEHj l00085]580ULl09H-0.12 l73.09l l175lDNTlP 1l l l 95}103l04/96l l C lTEC TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l27.59l l179lDNTlP 1l l l 99!103l04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+ 0.21 l12.081 l180lDNTlP 1l l 1101t1C3l04/96l lC lTEC-TEHjTEC-TEHj l00085l580ULl09H+ 0.06 1103.9l l174lDNTlP 1l l l103 ( *.03 } 04/96 l l C jTEC TEHlTEC-TEHj l00086l580UL]O9H+ 0.00 l32.93l l181lDNTlP 1l l l10$!*03l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.09 l59.21l l178lDNTlP 1l l l107:103l04/96l l c lTEC-TEHlTSC-TEHl l00086l500ULl09H+ 0.00 l34.98l l177lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00100j580ULl05H+ 0.00 l35.53l l180lDNTlP 1l l l 92l104]C4/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 j%0.26l l180lDNTlP1l l l 941104l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.06 l110.0l l173lDNTlP 1] l l 96!104l04/96l l C lTEC-TEH{TEC-TEHl l00086l580ULl09H+ 0.00 l81.41l l181lDNTjP 1l l l 981104l04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.03 l59.93l l176lDNTlP 1] l l1021104]04/96l l C lTEC-TEHlTEC-TE3l l00085l580ULl09H-0.12 l 5.76l l176lDNTlP 1] l l106l104]C4/96l l c lnC-TEHlTEC,TEHj 100085l580ULl09H+ 0.06 l61.45] l175lDNTlP 11 l l124 104l04/96l l C lTEC-TEHlTEC-TEHl l00092l580ULl10H-0.15 l 5.12l l178lDNTlP 1l l l 91i'.05l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULj09H+ 0.00 l59.82l l181lDNTlP 1l l l 93!105l04/96l l C lTEC-TEHlTEC-TEHj l00085l580UL]09H+ 0.18 l74.04l 1175lDNTl? 1l l i' l 95l*05jo4/96l l C lTEC-TEHlTEC-TEHj l 00086 l 580t%l 09H + 0.00 l44.43j l181lDNTlP 1l l l 97[105l04/96) l C lTEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.03 l105.6l l174lDNTlP 1l l l 99l105l04/96l lC lTEC-TEHlTEC-TEHl l00086l580VLl09H+ 0.00 l21.49l l183lDNTlP 1l l l101 [' 05 l 04 / 96 l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l15.63l l178lDNTlP 1l l l117a05l04/96l l C inc..nHITEC-nHl l00085l58eutl10H-0.03 l17.12l l175lDNTjP 1l l l1191105l04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULl10H+ 0.15 l20.56l l181lDNTlP 1l l l 1._. ' _ l l 1._ l l _ l_l 1 l l l _ i__ l_ L_ I_ I { i i 4 4 ROCKRIDGE TECHNOLOGIES l l

~ -- ~.. I l l CUMULATIVE REPORT 04/96, DGE, CALVERT CLIFFS, UNIT 1 STEAM GENIRATOR 11 PAGE: 12 0F 15 DUTAGE CATA SET CURRENT DATE: 06/06/96 SELECTICS VARIABLES: Indication Locat,lon, Percent TIME: 03:57:17 4 l i l EXAMj l l EXAM EXTENT l l l l l [ [ lROHlLIN DATEl HEAT 8 l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS lM'*.lDEGl % lCH lCHNGl l _ l--_ l l_l 1 l_I I I .I l__L l_.L_.L _l l121l10s 04/96l l C lTEC-TEHITEC-TEHI l00085l580uLl10H+ 0.09 l20.921 l179lDNTlP 2l l l123l105 04/96l l C lTEC-TEH]TEC-TEHj l00091l580ULl10H+ 0.00 l 7.95l l183lDNTjP 1l l l 92l106 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l40.14l l180lDNTlP 1l l l } 94l106 04/96) l C lTEC-TEHlTEC-TEHl l 0 0'08 5 l 5 8 0VLl 0,9H+0.09 l97.72l l174lDNTlP 1l l l 96l106 04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+ 0.00 l35.66l l182lDNTjP 1l l l 98]10E 04/96l l C lTEC-TEHlTEC-TEHl l00085l58bULlG9H+ 0.00 l24.30l l179lDNTlP 1l l l120j106 04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULl10H+ 0.00 l15.65l l183lDNTlP 1l l j l122l106 04/96l l C lTEC-TEHlTEC-TEHl l00085l5800Lj10H+ 0.09 l35.06] l178lDNTjP 1l l t ! 91l107 04/96l l C lTEC-TEHlTEC-TEH] l00086l580ULl09H+ 0.00 l67.48l l181lDNTlP 1l l 93l107 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.06 l102.0l l174lDNTlP 1l l l l 95l107 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l61.62l l181lDNTlP'1l l I 97l107 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.09 l55.39l l176]DNTjP 1l l 99l107 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l31.35l l181lDNTlP 1l l 103l107 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l69,70] (181lDNTlP 1l l l

107l10' 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l11.02l {180lDNTlP lj l .123l107 04/96l l C lTEC-TEHlTEC TEHl l00091l5800Ll10H+ 0.15 l17. 24 l l182lDNTlP 1] l 133l10i 04/96l l C lTEC-TEHjTEC-TEHj l00092l580ULl09H+ 0.21 l 6.12l 1179lDNTlP 1l l' 94l10f $4/96l lC lTEC-TEHlTEC TEHl l00085l580ULl09H+ 0.27 l45.78l !175lDNTlP 1l l 96l106 04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l104.9l '179lDNTlP ll l 98l109 04/96l jC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.03 l60.86l 1176lDNTlP 1l l 100l106 04/96l l C ITEC-TEHlTEC-TEHl l00C86l580ULl09H+ 0.00 l32.89l l182lDNTlP 1l l i 102l1C6 04/96l lC !TEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.00 l41.48l 1175lDNTlP 1l l 104l106 04/96l l C lTEC-TEHlTEC-TEH) l00086l580ULl09H+ 0.00 l25.96l +181lDNTlP 1l l 106l10E 04/96l l C lTEC-TEHlTEC-TEHl lD008bl580ULl09H-0.06 l25.10l. l175lDNTlP 1l l q 108l106 04/96l l C lTEC-TEHlTEC TEHl l00086l580ULl09H+ 0.00 l17.2 9 l !182]DNTjP 1l l 118l10s 04/96l l C lTEC TEHlTEC-TEHl l00085l$80ULl10H-0.06 l38.57l il74lDNTlP 1l l 91l105 04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULl09H+ 0.00 l24.90l l182lDNTlP 1l l 93l109 04/96l l C lTEC-TEHlTEC-TEHl l000851580ULl09H+ 0.09 j46.75l il75lDNTlP lj l 95l10& 04/96l lC lTEC-TEHlTEC-TEHl l00C86l500ULl09H+ 0.00 l32.87l l182lDNTlP 1l l 97l101 04/96l lC lTEC-TEHjTEC-TEHl l00085l580ULl09H-0.12 l86.08l 7172lDNTlP 1l l ) 99l103 04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l30.33l 1182lDNTlP 1l l 101l109 04/961 l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l29.00l l176lDNTlP 1l l 103l109 04/P6l lC lTEC-TEHlTEC-TEHj l00086l580UL]O9H+ 0.00 l64.38l l181]DNTlP lj j 119l109 04/96l l C lTEC-TEH]TEC TEHl l00086l580ULl10H+ 0.00 l12.07) !181lDNTlP 1l l .121l109 04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULj10H+ 0.06 l24.17l !175lDNTlP 1] l 92l110 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l19.16l l180lDNTlP ll l l 94l117 04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.00 l31.41l l176lDNTlP 1l l 96l110 04/96l lC lTEC-TEHlTEC-TEHl l00086l5800Ll09H+ 0.00 l14.23l l181lDNTlP 1l l 98l11C 04/96l lC lTEC-TEH]TEC TEHj l00085l580ULl09H+ 0.06 l18.34l jl?8lDNTlP 1l l 106l110 04/96l l C lTEC-TEHlTEC TEHl l00085l580ULl09H+ 0.00 l14.94l l174lDNTlP 1l l 91l111 04/96l l C lTEC-TEHlTEC TEHl l00086l580ULl09H+ 0,00 l42.94l l181lDNTlP 1l l 93l11*.04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H. 0.09 l48.58] il76lDNTjP 1l l 95l111 04/96l l C jTEC-TEHlT'4C-TEHl l000861580ULl09H+ 0.00 l31.18l l181lDNTlP 1l l l ( 103l111 04/96l l C lTEC-TEHjTEC-TEH1 l00086l580ULl09H-0.30 l10.12l l179lDNTlP 1l l l 04/96l l C lTEC-TEHlTEC-TEHl l00086l5800Ll09H-0.18 l10.03l 1176lDNTlP 1l l _L I l_I l l_I l l l _ L L._ l-_ I __ I __ I 4 ROCKRIDGE TECHNOLOGIES i l l l l

... _, ~. ~, l CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GINERATOR

11 PAGEt 13 OF 15 OUTAGE CATA SET CURRENT DATE:

06/06/96 SELECTICN VARIABLES: Indication Location, Percent TIME: 03:57:17 ( j' l EXAM l l l EXAM EXTENT l l l l l l l lkOWlL:N DATElUEAT#lLEGj PROGRAM l ACTUAL lEXPl CAL l PROBE l 14 CAT 10N lv0LTSl MIL'DEGl t lCH lCHNGl l l_i_ l l_I I l_l l l l l___L _.l_._l__._l. _,l l l 92l112 04/96] l C lTEC-TEHjTEC-TEHl l00086l580ULjo9b 0.00 l25.13l 1182lDNTlP lj l l 94l112,04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H- 0.06 l43.31l l175lDNTlP 1l l l l 96l112 04/96l l C lTEC-TEHjTEC-TEHj l00086l580ULl09b 0.00 l22.79l l179lDNTlP ll l l 98l1'2'04/96l l C lTEC-TEHlTEC-TEHl l 00'085 l580ULl 0,9b 0.00 l17.51l l179lDNTlP 1l l l202l112 04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H. 0.09 l24.15l l176lDNTlP 1l l l120l112 04/96l l C lTEC-TEHlTEC-TEHl l00086l58bULl10b 0.00 l54.86l 3178lDNTlP 1l [ l122l112 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl10b 0.00 l18.71l il76lDNTlP 1l l l 91l1;3 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl096 0.00 l36.44l 1182lDNTlP 1l l l 93l113 04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl096 0.09 l94.94l f173lDNTlP 1l l l 95l1;) 04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULjo96 0.00 l29.47l l178lDNTlP 1l l l 97l1H 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09b 0.12 l97.30l !175lDNTlP*1] l l 99l1*) 04/96l lC lTEC-TEHlTEC-TEHl l 00086 l 58 0ULl 09H-0.00 l129.9l ,175lDNTlP lj l l101l1"3 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09b 0.00 l 74'. 27 l 178lDNTlP 1l l l103l1;s 04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09E. 0.00 l36,36l 178lDNTlP 1l l l105l1M 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09b 0.00 l52.80l 175lDNTlP ll l l117l1; 04/96l l C lTEC-TEHlTEC-TEHl l0008Sl580ULl10b 0.00 l50.49l 176lDNTlP 1l l l121l1*3 04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl10H. 0.03 l50.25l 176lDNTlP 1\\ l ) l123l1M 04/96l l C lTEC-TEHlTEC-TEHl l00091l580ULl10H-0.06 l33.98l ~81lDNTlP 1l l ] l 92l114 04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09b 0.00 j41.24l 179lDNTlP ll l l 94l114 04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H-0.06 l86.60l 1174lDNTlP 1l l l j 96l1;4 04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09b 0.00 l76.69l 175lDNTlP 1l l l 98l;*.4 04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl096 0.00 l49.32l 176lDNTlP 1l l l100l1;. 04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULl096 0.00 l34.02l 180lDNTlP 1l l l102l1;4 04/96l lC lTEC-TEHlTEC-TEHl j o 0085 l 50 0CLl 0$H-0.09 l37.77l 176lDNTlP 1l l104l1., 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl096 0.06 l20.97l 182lDNTjP 1l l l106l114 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H- 0.00 l24.22l 177lDNTjP 1l l l118l1;4 04/96l lC lTEC-TEHjTEC-TEHl l 00085 l 580ULl10H-0.00 l 6.48l 178lDNTlP 1l l l122l1;4 04/96l j C lTEC-TFHlTEC-TEHl l00085l580ULl10H-0.00 l24.30l 175lDNTlP 1l l l 93l1;i 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.09 l32.25l 176]DNTlP 1l l l 97l1;! 04/96l lC lTEC TEHlTEC-TEHl l00085l500ULl09b 0.03 l35.36l

  • 76lDNTlP 1l l

jl01l1. 04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H. 0,36 l 15. 4 9 l 176lDNTlP 1l l l121l1;! 04/96] l C lTEC-TEHlTEC-TEHl l00085j580ULl10H- 0.00 l 7.10l 179lDNTlP 1l l l 96l1D 04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl096 0.00 l29.13l

175lDNTlP lj l

l 98l1;f 04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09b 0.00 l20.94l

183lDNTlP 1l l

l106l1;* 04/96l l C lTEC-TEHlTEC-TEHj l00083l580ULl09b 0.15 l 5.14l 183lDNTlP 1l l j l120l1;f 04/96l l C lTEC-TEHlTEC-TEHl l00083l580ULl096 0.49 j E.15l 183lDNTlP 1l l l126l1*.3 04/96l lC lTEC-TEHlTEC-TEHl l00100l580ULl09H-0.24 l 6.41l 179lDNTjP 1l l l 91l1;* 04/96l l C lTEC-TEHlTEC-TEHl l00083l580ULl09b 0.23 l 6.67]

181lDNTlP lj l

l207l1;" 04/96j j C lTEC-TEHlTEC-TEHj lD0083l580ULl09b 0.03 l15.92l l183lDNTlP 1l l l102l115 04/96l l C lTEC-TEHlTEC-TEHl l00083l580ULl096 0.17 l 7.70l l182lDNTlP 1l l l 97l13 04/96l l C lTEC-TEHjTEC-TEHl l00084l580ULl09b 0.00 l35.98l

176lDNTlP 1l l

l 99l1*.i 04/96l l C lTEC-TEHlTEC-TEHj l00084l580ULl09b 0.30 l16.85l 178lDNTlP 1l l l 98l1;: 04/96l { C lTEC-TEHlTEC-TEHl l00084l580ULl09H. 0.21 l28.60l ,178lDNTlP 1l l l202l1; 04/96l l C lTEC-TEHjTEC-TEHl l00084l580ULl09H. 0.00 l17.16l '178lDNTlP 1l l l106l12: 04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULl09b 0.00 l38.92) '177lDNTlP 1l l l _ ! _._. l l_1 I l_l l l I l ____ - l_ L._ I _ I ROCKRIDGE TECHNOLOGIES

1 I CUMUIATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 E*EAM GENEMTOR 11 PAGEt 14 OF 15 C".7TAGE DATA SET CL%ENT DATE: 06/06/96 SILECTION VARIABLES: Indication Location, Percent TIME: 03:57:17 1 1 l l NAM l l 1 EXAM EXTENT l l l l l l ! ROW lLINl U.TEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE lLOCATION [ VOLTS l MIL lDEGl t lCH lCHNGl i._ l._ l- _.-_ l - l_I I l_1 1 I I 1_ L_L l _I 1 l .i 91l121l 04 / 96 l l C lTEC-TEHlTEC-TEHl 'l00081l580ULl09H+ 0.06 l23.06l l190lDNTlP 1l l

93l121l04/96l lC lTEC-TEHlTEC-TEHl l000A1l5800Ll09H+

0,03 l62.48l l185lDNTlP 1l-l

105l121l04/96l lC lTEC-TEHlTEC-TEHl l00084l580ULl09H+

0.00 l11.54l l175lDNTlP 1l j

  • 07l121l04/96l l C lTEC-TEHlTEC-TEHl l 00084 l 580ULl 0,9He 0.00 j53.37l l177lDNTlP 1l l

Iit9j121l04/96l l C lTEC-TEHjTEC-TEHl l00084l580ULl09H-0.18 l27.54l l178lDNTlP 1l l 92l122lC4/96l lC lTEC-TEHlTEC-TEHl l00081l58hULl09H+ 0.00 l77.94l l184lDSTjP ll l 94 l122 l 04 /96 ] lC lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.00 l76.89l l184lDNTlP 1l l 96 l122 l 04 /96 l lC lTEC-TEHjTEC-TEHj l00081l580ULjo9H+ 0.06 l11,75l l185lDNTlP 1l l - 02l122l04/96l l C lTEC-TEHlTEC-TEHj l00081l580ULl09H-0.03 l 5.71l fi90lDNTlP 1l l 106l122l04/96l l 0 lTEC-TEHlTEC-TEHl l00081l580ULl09U+ 0.15 l 5.08l 1185lDNTlP 1] l 91l123 l 04 /96 l l lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.09 l47.86l i185lDNTlP*1l l 93l123l04/96l l C lTEC-TEHlTEC-TEHl l000811580ULl09H+ 0.03 l55.82l

184lDNTjP 1l l

95 l123 l 04 / 961 l lTEC-TEHlTEC-TEHj l00081l580ULjo9H+ 0.09 l12.67l .183lDNTlP 1l l 97l123l04/96l l jTEC-TEHlTEC-TE9l l00081l580ULl09He 0.03 l30.07l ,;66lDNTlP 1l l ".01l123 l 04 '96 l l 0 lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.06 l 6.81l .*85]DNTlP lj l 123 l123 l 04 / 96 l l : lTEC-TEHlTEC-TEHl l00092l580ULl10H-0.34 l 6.05j

72lDNTjP lj l

92l124l04/96l l0 lTEC-TEHjTEC-TEHl l00081l580ULjo9H+ 0.15 l105.0l .;83lDNTlP 1l l 94 l124 l 04 / 96 l l 2 lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.29 l112.9l .183lDNTlP 1l l 98l124l04/96l l lTEC-TEHlTEC-TEHl l00061l580ULl09H+ 0,09 l34.47l 186lDNTlP ll l-91l125l04/96l l2 lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.00 l52.47] .;85lDNTlP ll l l 93l125l04/96l l 0 lTEC-TEHlTEC-TEHl l00099l580ULj09H+ 0.09 l71.37l !185lDNTjP lj l 9 9 l125 l 04 / 96 l l 0 lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.06 l26.10l 186lDNTlP 11 l 92l126l64/s6l l0 lTEC-TEHjTEC-TEHl l00099l580ULl09H+ 0.c9 146.72l .;84lDNTlP 1l l $<. il26 p4 <96 l l: ITEc-TEHlTEC-TEHI l000991580utl09H. 0.e6 !?9.211 84lDNTjP if I ] 96l1Ml04/96l l lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.03 l86.10l

  • 91lDNTjP ll l

98 l126 l 04 '9 6 l l2 lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.12 l26.81l 186lDNTlP 1l l

  • 1l121l04/96l l : lTEC-TEHlTEC-TEHj l00079l580ULl09H+

0.12 l55.63l 185lDNTlP 11 l ) 93l127l04/96l l ; lTEC-TEHlTEC-TSHj l00080j580ULl09H+ 0.09 l72.76) 177lDNTlP ll l l l l04'96l l: lTEC-TEHlTEC-TEHj l00099l580ULl09H, O.09 l78.25l 185lDNTlP 1l l 95 l 12'i l 04 / 96 l l 2 lTEC-TEHlTEC-TEH) l00079l580ULl09H+ 0.00 l25.94l 184lDNTlP 1l l 97[127l04 96l 1: lTEc-TEHITEC-TEHI ,100099l580ULl09H+ 0,00 156.73l 186lDNTlP 1l l l l04 96l t: lTEC-TEHITEC-01HI l000801580usl09H+ 0.06 150.051 78lDNTlP 1l l 92l128l04/96] l 0 lTEC-TEHlTEC-TEHl l00074l580ULl09H+ 0.00 l51.59l 1180lDNTlP 1l l 98l128l04/96l l: lTEC-TEHjTEC-TEHl l00073l580ULl09H+ 0.03 l 8.47l !;80lDNTlP 1l l 93l131l04/96l l : lTEC-TEHlTEC-TE4l l 00073 ]580ULl09H+ - 0.15 l19.00l

179lDNTlP lj l

92l132104/96l l: lTEC-TEHITEC-TEHl l00074l580utl09H. 0.26 l 7.47l

178lDNTlP 1l l

95l133l04/96l l lTEC-TEHlTEC-TEHl l00374l580ULl09H+ 0.29 -l 5.55l f176lDNTlP 1l l 96l134l04'96l l lTEC-TEHlTEC-TEHl l00073l5800Ll09H+ 0.30 l 5.51l

177lDNTlP 1l l

97 l137 l 04 /9 6 l l lTEC-TEHjTEC-TEHl l00073l580ULl0$H. 0.47 l12.37l .176lDNTlP 1l l 92l138l04/96l l lTEC-TEHlTEC-TEHl l00074l580ULl09H+ 0.00 l 5.44 l 1179lDNTlP 1l l __._ I _ I l LI l l__ l - l 1 i l_ _I_l_1_ t ROCERIDGE TECHNOLOGIES

.-....=2 CLNULATIVE REPoitT 04/96, BGE, CALtERT CLIFFS, UNIT 1 j STEAM CENERATOR 1 11 i PAGEs 15 OF 15 - OLTTAGE DATA SET

CURRENT DATES C6/06/96 SELECTION VARIABLES: Indication Location, Percent TIME:

03:57:17 NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: 619 NUM3ER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 625 NO TREND ANALYSIS REQUESTED DATA SELECTION CRITERIA: 8 ,i i Indication Location: 09H 0.50 to 10H bo.50 (Supports Only) Percent: DNT 4 i REPORT OPTIONS: C nly examination results matching criteria are included l I 4 'r A ROCKRIDGE TEC30TOLOGIES I i

-- =,.. CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR 1 11 PAGE: 1 OF 1 CUTAOE DATA SET CURRENT DATE: 06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME: 04:06:34 l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl LATE l HEAT #l LEG l PROGRAM l ACTUALjEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl t lCH lCHNGl I _ _i _.i I l! I l_l l I I l L _L I_l _ I l 91l 61l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09C+ 0.33 l 7.30l l357lDNTlP 1l l l117l 61l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl10C-0.03 l 9.87l l175lDNTlP 1l l l 95) 73l04/96l l C lTEC-TEHlTEC-TEHj l00037l580ULl09C+ 0.03 l 8.44l l175lDNTlP1l l l l 91l 85l04/96l l C lTEC-TEHjTEC-TEHl l 0dO87 l 580ULl 0,9C- 0.33 l 7.60l l170lDNTlP 1l l j 99l 95l04/96l l C lTEC-TEHlTEC-TEHl l00087l580VLl09C- 0.21 l 5.86l l179lDNTlP 1l l l117l105l04/96l l C lTEC-TEHlTEC-TEHj l00085l58tULl10C-0.06 l 8.12l {178lDHTlP 1l l l 91l121l04/96l l C lTEC-TEHlTEC-TEHl l00081l580ULl09C+ 0.49 l34.47l l185lDNTlP 1l l L_ L _I I L._. I i L! I i* I L L._ L _l I I NUG ER OF TUDES SELECTED FROM CURRENT OUTAGE: 7 NUGER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 7. NO ** REND ANALYSIS REQUESTED I ATA SELECTION CRITERIA: Inh:ation Location: 09C 0.50 to 10C 0.50 (Supports Only) Per:er.t: DNT EEFORT OPTIOUS: Only examination results matching criteria are included d J 4 W I ROCKRIDGE TECENOLOGIES e .i

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 l STEAM GENERATOR 11 PAGE: 1 OF 1 OtfrAGE DATA SET CURRENT DATE: 06/06/96 SELECTION VARIABLES: Indication Location. Percent TIME: 04:09:46 l l l EXAM l l l EXAM EXTENT l l l l l l lROWjLINl DATEl HEAT #l LEG l PROGRAM l ACTUALjEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_i_I I l_I I L_I I I I L_ L_ i _ ( _ I _.__.I l 99l 29l04/96l l C lTEC-TEHlTEC-TEHj l00029l580ULl01H+ 0,00 l 5.12l l183]DNTjP 1l l l 88l 30l04/96l l C lTEC-TEHlTEC-TEHj l00025l580ULl03H+ 0.67 l 5.51l l380lDNTlP1l l l 40l 58l04/96l l C lTEC-TEHjTEC-TEHj l00047l580ULl03H-0.74 l10.10l l177lDNTlP 1l l l 58l 74l04/96l l C lTEC-TEHlTEC-TEH[ l00117l580ULl07H-0.72 l 7.00l l173lDNTlI 1l l l 39l101l04/96l l C lTEC-TE!!lTEC-TEHj l00068l580ULl07H+ 0.27 l 8.16l l176lDNTlP1l l l 97l137l04/96l l C lTEC-TEHlTEC-TEHl l00073]580ULl08H+ 0.48 l 7.70l l175lDNTlP1l l l 46l138l04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULl06H+ 0.21 l10.94l l180lDNTlP 1l l L_I_I I l_ L_ l L_.I I I I l_ L._ L._ L_ !_ I NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: 7 NUMBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 7 NO TREND ANALYSIS REQUESTED DATA SELECTION CRITERIA: Indication Location: 01H pl.00 to 08H hl.00 (Supports Only) Percent: DNT REPORT OPTIONS: Only examination results matching criteria are included i I ROCK 1LIDGE TECHNOLOGIES

~.~,. ~.. l CUMULATIVE REPORT 04/96, EDE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 !,.JE 1 OF 1 OLTTAGE DATA SET CURRENT DATE: 06/06/96 SELECTION VARIABLES: Indication Location, Percent TIME: 04 :23:f 2 1-1 I nAMI i i uAM EXTENT.. I 1 l l l l lRowiuNl DATElHEATNl LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl i l__ L__ l 1 l_1 I l_1 1 I I l _ L__ l _ f._._ l I-j 27] 35l04/96l l C lTEC-TEHlTEC-TEHl l00006l580ULl03C+ 0.80 l4 9.54 l jl79lDNTlP1l l l 82l126l04/96l l C lTEC-TEHlTEC-TEHl l00073]580ULl08C- 0.69 l 6.02l l179lDNTlP 1l l l 42l154]C4/961 l C lTEC TEHlTEC TEHj l00058l580ULl07C+ 0.60 l22.05) l181lDNTjP1l l l 'l l04/96l lC lTEC-TEHlTEC-TEHj. l00b58l580ULl07C- 0.91 l 6.61l l182lDNTlP 1l l l _._ I _ I I l __I I L__I I I I l __ I _ I _1.__ l l ) NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: 3 h*JMDER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 4 NO TRIND ANALYSIS REQUESTED DATA SELECTION CRITERIA: Indication Location: 01C pl.00 to 08C >1.00 (Supports Only) Percer.t : DNT j I REECRT OPTIONSt only examination resul s matching criteria are included 1 I' 4 l l ROCKRIDGE TECHNOLOGIES a l l l

CUMULATIVE REPORT 04/06 BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 1 OF 2 O!TTAGE DATA SET

CURRENT DATE:

06/06/96 SELECTION VARIABLES: Indication Location, Percent TIMES 04:24:44 I i i EXAMI I l EXAM EXTENT l l l l l l lRONlr,1Nl DATElHEATW l LEG l PROGRAM l AC"UALj EXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH.lCHNGl 'l_I_I I l_1 l L._I I I I l _ I___l-._1_ _I l l 40l 14l04/96l l C lTEC-TEHlTEC-TEHl l00014l580UL]VM + 1.72 l 8,24l l174!DNTlP 1l l --l 29l 15l04/96l l C lTEC-TEHlTEC-TEHl l00103l580ULlVM - 1.26 l12.56l l172lDNTjP 1l l l 31l 19l04/96l l C lTEC-TEHlTEC-TEHj l000.15l580ULlVM - 1.84 l10.29l l179lDNTlP 1l l 'l 31l 25l04/96l l C lTEC-TEHlTEC-TEHj l06017l580ULjvM - 1.90 l 8.27l l178lDNTlP ll l I 35l 27164/961 1 C lTEC-TEHjTEC-TEHj l00103l5800LlDC - 1.35 l 5.83l l356]DNTlP 1l l l 28l 30l04/96l l C lTEC-TEHlTEC-TEHj l00011l580ULlVM + 1.86 l 8.03] (174lDFflP 1l l 1 l 28l 40l04/96l l C lTEC-TEHlTEC-TEHl l00006l580ULlVM + 1.94 l 7.32l l174lDNTlP 1l l i l 10l 42l04/96] l C lTEC-TEHlTEC-TEHl l00104l5800LlvM + 0.86 l13.20l l173]DNTlP 1l l j 41l 47l04/96l l C lTEC-TEHlTEC-TEHl l00123l580ULlVM - 1.92 l11.99l l175lDNTjP 1l l 'l 28l 56l04/96l l C lTEC-TEHlTEC TEHj l00047l580ULjVN + 1.95 l20.98l l174lDNTlP 1l l l 411 59104/961 l C lTEC-TEHlTEC-TEHl l00113l580ULlVM - 1.86 l 8.90l l171lDNTlP*1l l l 41l 61l04/96l l C lTEC-TEHlTEC-TEHj l00115l580ULlVM - 1.94 l11.58l l172lDNTjP 1l l ]~35l 73]O4/96] l C lTEC TEHlTEC-TEHj l00048l580ULlVM + 0.00 l12.90l l181lDNTlP 1l l l 45l 77l04/96l l C lTEC-TEHlTEC TEHl l00181l5800LlVM - 2.00 l G.16l l174lDNTlP 1l l l 40l 84l04/96l l C lTEC-TEHjTEC-TEHj l00126l580ULlVM + 1.97 l 9.72l l178lDNTlP 1l l l 40l 86l04/96l l C lTEC-TEHlTEC-TEHl l00128l580ULlVM + 2.00 l 6.05l l181lDNTlP 1l l l 40l 88l04/96l l C lTEC+TEHjTEC-TEHj l0012Bl580ULlVM + 1.85 l 9.36l l177lDNTlP lj l l 501100l04/96l l C lTEC-TEHlTEC-TEHI l00071l580uLlvM - 2.00 l 5.35l l179lDNTlp it l l 37l101l04/96l j C {TEC-TEHlTEC-TEHl l00069l580ULlVM - 0.73 l24.85l l177lDNTlP 1l l l 21l103l04/96l l C lTEC-TEHjTEC-TEHl l00069l580ULlVM + 0.52 l 5.96l l174lDNTlP 1l l l111l105l04/96l l C lTEC-TEHlTEC-TEHl l00006l580ULlVC + 1.53 l10.92l l175lDNTjP 1l l l 35l113l04/96l l C lTEC-TEHlTEC-TEHj l00065l580ULlVM - 1.44 l 7.34l l 3lDKrlP 1l l { l 91l119104/96l lC lTEC-TEHlTEC-TEHl l00084l580ULlVM - 1.02 l13.53l l1751DNTlP ll l l 82(126l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULlVH + 1.67 l23.26] l178lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULlVM - 1.34 l 9.34l l175lDNTlP 1l l l 41l135l04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULlVM - 1.76 l 5.92l l177lDNTlP 1l l ] l 36l136l04/96l l C lTEC-TEHlTEC-TEHl l00056l580ULlVM + 1.84 l 5.98l l175lDNTlP 1l l l 31l137l04/96l l C lTEC-TEHlTEC-TEHl l00058l5800LlVM - 1.68 l 6.86l l176lDNTlP 1l l l 35l177l04/961 l C lTEC-T1.HITrC-TEHI l0005sl5BOUnivM 1.36 l 5.63l l198lDNTlP ll l 4 l 31l139l04/96l l C lTEC-TEHjTEC-TEHj l00058l580ULlVM - 1.82 l 9.84[ l174lDNTlP 1l l l 37l139l04/96l l C lTEC-TEHlTEC-TEHj l00059l580ULlVM - 1.57 l11.70l l176lDNTlP 1l l l l l04/96[ l C lTEC-TEHlTEC-TEHj l00059l580ULlVM + 1.86 l 9.14l l180lDNTlP 1l l l 35l141104/96l l C lTEC-TEHlTEC-TEHl l000581580ULlVM - 1.96 l 6.40l l 1lDNTjP 1] l l 90l142l04/96l l C lTEC-TEHlTEC-TEH] l00074l580ULlVM - 1.73 l11.10l l180lDNTlP 1] l l 31l143l04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULlVM - 1.60 l 5.22l l177lDNTlP 1l l l 37l145l04/96) j C lTEC-TEHlTEC-TEHl l00059l5800LlVM - 1.72 l 8.01l l176lDNTlP 1l l l 37l151l04/96l l C lTEC-TEH]TEC-TEHj l00059l580ULlVM - 1.56 j13.55l l178lDNTlP 1l l j 48l154l04/96l .l C lTEC-TEHlTEC-TEH{ l00059l5800LlDH - 0.42 l10.91l l177lDNTlP 1l l q l 13l157l04/96l l C lTEC TEHlTEC TEHl l00053l580ULlVM + 0.21 l 7.04l l175lDNTlP 1l l l 31l157l04/96l l C lTEC-TEHlTEC-TEHl l00056l580ULlVM - 1.70 l 9.20l l176lDNTlP 1l l -l 55l159l04/96l lC lTEC-TEHlTEC-TEHj l00056l580ULlVM + 1.97 l11.54l l176lDNTlP 1l l l 31l161l04/96l l C lTEC-TEHlTEC-TEHj l00057l580ULlVM - 1.49 l 8.99l l178lDNTlP 1l l l l 31l163l04/96l l C lTEC-TEHlTEC-TEHl l00056l580ULlVM - 1.66 l 8.78l l175lDNTlP 1l l j 35l163l04/96l l C lTEC-TEHlTEC-TEHj l00056l580ULIVM - 1.97 l 7.31l l180lDNTlP ll l 1-l._J l L _I I l_I I I I l _-.L _ I _ I_ _l _ _I 1 i ROCKRIDGE TECHNOLOGIES 4

= l 1 CUMUIATIVE REPORT '04/96, E38, CALVERT CLIFFS UNIT 1 (" TAM GENERATOR 11 PAGE: 2 OF 2 ] i ' l WAGE DATA SET CURRENT DATE: 06/06/96 ! ELECTION VARIABLES: Indication Location, Percent TIME: 04:24:44 T.HBER OF TUBES SELE'TED FROM CURRENT OUTAGE: 42 EKBER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 44 I i 53 TREND ANALYSIS REQUESTED I i CATA SELECTION CRITERIA:

ndication Location: DH p2.00 to DC )2.00 (Supports Only) 7ercent Oh7 l

72 PORT OFTIONSt r.ly examination results matching criteria are included 1 j l i 1 1 l l ROCKRIDGE TECHNOLOGIES

e-CUhfULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 1 OF 8 OUTAGE DATA SET i CURRENT DATE: 06/14/96 SELECTION VARIABLES: Percent. TIME: 10:10:19 I l l l EXAbfl l l EXAM EXTENT l l l l l l l ROW lLIN) CATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l IDCATION lVT *Sl MIL lDEGl % lCH lCID4Gl l_I_ _I I l_t I LI I i l l_ l __L l-_i _ I l 31} 3l04/96l lH l ] l l00000l l l l l lTBPl l l l 30l 4l04/96l lNl l l l00000l l l l l lTBPl l l l 6l 6l04/96l l H *l l l l00000l l l l l [TBPl l l l 27l 7l04/96l lH l l l l00b00l l l l l lTBPj l l l 61l 13j04/96l lH l l l l00000l l l l l lTBPl l l l 75l 15lC4/96l lMj l l l00000l l l l l lTBPl l l l 17l 17l04/96l lH l l l l00000l l l l l lTBPl l l l 10) 22l04/96l lHl l l l00000l l* l l l lTBPl l l l 26l 22l04/96l lHl l l l00000l l l l l lTBPl l l l 68l 22l04/96l lH l l l l00000l l l l l (TBPl l l l 17l 23l04/96l lH l l l l00000l l l l l lTEPl -l l l 63l 23l04/96l lHl l l l00000l l l l l lTBPl l l l l 10l 26l04/96l lH l l l j00000l l l l l (TBPl l l l 78l 28l04/96l lH l l l l00000l l l l l (TBPl l l \\ 68l 30l04/96l lH l l l l00000l l l l l j7BPl l l (101l 31l04/96l lH l l l l00000l l l l l (TBPl l l l 64) 32l0'/96l lH l l l l00000l l l l l lTBPl l l l 86l 32lC /96l lH l l l l00000l l l l l [TBP{ l l l 58} 34l04/96] jH l l l l00000l l l l l lTBPl l l l 68l 36l04/96l lHl l l l00000l l l l l [TBPl l l l 1] 37l04/96l lHl l l l00000l l l l [ {TBPl l l i 93l 37l04/96l lH l [ l l00000l l l l l lTBPl l l l 64l 40lc4/96l lNl l l l00000l j l l l lTBPl l l l 82l 40l04/96l lHl l l l00000j j l l l lTBPl l l l105j 41l04/96l lH l l l l00000l l l l l lTBP[ [ l l j115l 41l04/96l lH l j l l00000l l l l l lTBPl l l l 2l 42l)4/96l l Hl l l l00000l l l l l lTBPl l l [ 66l 42l04/96l l H l l l l00000) i l l l lTBPl l l l 68l 42l04/96l lH l l l l00000l l l l lTBPl l l l l104l 42l04/96l lH l l l j00000l 1 l l l lTBPl j l [ l106l 42l04/96l lHl l l l00000} l l l l lTBPl l l 1108l 42j04/96l lH l j l lC0000l l l l l lTBPl l l l 3] 43l04/96l lH l l l l00000l l l l l lTBPl l l 1 5l 43l04/96l lHl l l l00000l l l l l lTBPj l l l 12l 44l04/96l lHl l l l00000l l l l l lTBPl l l l 62l 44l04/96l lNl l l l00000l l l l l lTBPl l l j 66l 44l04/96l lH l l l l l00000l l l l l [TBPl l l k ] 9) 45l04/96l lHl l l l00D00l l l l l lTBPl l l l 91l 45l04/96l lN l l l l00000l l l l l lTBPl l l 1101l 45l04/96j lNl l l l00000l l l l l [TBPl l l l 80l 46l04/96l lHl l l l00000l l l l l lTBPl l l l 82) 46l04/96l lNl l l l00000j l l l l (TBPl l l ! 75l 47l04/96l lHl l l l00000l l l l l lTBPl l l l 79l 47l04/96l lE l l l l00000) l l l l lTBPl l [ 85l 47j04/96l jHl l l l00000l l l l l lTBPl l l l_1_i i l __ I l _ _ l-._ L. _ I l_ l L_ L_ l_._l__ l _ I POCKRIDGB TECHNOLOGIBS )

CUMULATJt!E CEPORT 04/96, ECE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

2 OF 8 OITTAGE DATA SET

CURRENT DATE:

06/14/96 SELECTION VARIABLES: Percent TIME: 10:10:19 l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPJ CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l -__ l ---_1 1 l_ _l I l-___ t i I I L l _. l __ l __.L,_ l l 91) 47l04/96l lNl l l l00000l l l l l lTBP] l l l 20l 48l04/96l lHl l l l00000l l l l l lTBP) l l l 56l 48l04/96l lNl l l l00000l l l l l (TBPl .l j l102l48l04/96l lN l l { l 00'000 l l, I l l lTBPl l l l 67l 49l04/96l lBl l l l00000l l l l l lTBPl l l l 46l 50l04/96l lMl l l l00000l l l l l (TBPl l j l112l 50l04/96l lM l l l l00000l l l l l lTBPl l l l 55l 51l04/96l lHl-l l l00000l l l l l lTBPl l l l 81] 51l04/96l lHl l 1 l00000l l l l l lTBPl l l l 60] 52l04/96l lMl l l l00000l l l l l lTBPl l l l 66) 52l04/96l lH l l l l00000l l l l 1 lTBPl

  • l l

l 72l 52l04/96l lHl l l l00000l l l l ( lTBPl l l l106l52l04/96l lHl l l l00000l l l l l lTBPl l l l 41l 53l04/96l lHl l l l00000l l l l lTEPl l l l 47l 53l04/96l lH l l l l00000l l l l lTBPl l l l 69] 53l04/96l lH l l l l00000l l l l lTBPl l l } B7l 53l04/96l lHl l l l00000l l l l lTBPl l l l 97l 53l04/96l lH l l l l00000l l l l (TBPl l l l103l 53l04/96l lH l l l l00000l l l l lTBPl l l r l 46l 54l04/96l lH l l l l00000l l l l (TBPl l l l 48) 54(04/96l-lE l l l l00000l l l } lTBPl l l l 50l 54l04/96l lH l l l l00000l l l l lTBPl l l l 64l 54l04/96l lN l l l l00000l l l l (TBPl l l } 70j 54l04/96l lH l l l l00000l l l l lTBPl l l l 23l 55l04/96l lHl l l l00000l l l l l lTBPl l l l 47l $$[04/96l lHl l l l00000l l l l l lTBPl l l l 49l 55l04/96l lHl l l l00000l l l l (TBPl l l l 51l 55l04/96l lH l l l l00000l l l 1 (TbPl l l l 53l 55j04/96l lH l l l l00M0l l l l lTBP) l l l121l 55l04/96) 'l H l l l l00000j l l l lTBPl l l l 46l 56l04/96l lHl l l l00000l l l l {TBPl l l l 48l 56l04/96l lN l l l l00000l l l l lTBPl l l l100] 56l04/96l lH l l l l00000l l l l jTBP) l l l130l 56l04/96l lM l l l l00000l l l l ) (TBPl l l l 17l 57jo4/96l lNl l l l00000l } l l lTBPl l l l 57l 57l04/96l lH l l l l00000l l l l l lTBPl l l l133l 57l04/96l lHl l = l l00000l l l l l lTBPl l l l 20l 58l04/96l lBl l l l00000l l l l l lTBPl l l l 32] 58l04/96l lH l l l l00000l l l l l (TBPl l l } 96l 58l04/96] jH l l l l00000l l l l l l TOP ( l l l106l 58l04/96l lH l l l l00000l l l l lTBPl l l l 11l 59l04/96l lHl l l l00000l l l l l lTBPl l l l 13l 59l04/96l lHj l l l00000l l l l i (TBPl l l l 15l 59l04/96l lMl l l l00000l l l l l lTBPl l l l 17l 59l04/96l lHl l l l00000l l l l [ lTBPl l l l _I____I I L_I I l-_ I I l I l _ I_. l_ I _ I_ I ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFPS, UNIT 1 STEAM GENERA 7.>R 11 PAGE: J OF 8 OLiAGE DATA SET s C"JRRENT DATE: 06/24/96 EI!ICTION VAAIABLES t Percent TIME: 10:10:19 l l EXAM l l l EXAM EXTENT l l l l l l l row lLINl DA3l HEAT $lI.EGlPfiOGRAMl ACTUAL lEXPl CAL lPROBEj LOCATION l VOLTS l MILL?EGl % lCH lCHNGl L.__L._i l I.___I I l_l i I l L__ L_ l___ L _ l_ I 1 19l 59l04/96l lE l-l l l00000l l l l l lTBPl l l j 23l 59l04/96l lN l l l l00000l l l l l lTBPl j l 45l 59l04/96l lE l l l l00000l l l l l lTBPl l 1 ' 55l 59l04/96l lEl l l l00000l l, l l lTBPl l l 69l 59l04/96l lB l l l l00000l l l l lTBPl l } j 81] 59l04/56l lE l l l l00000l l l l lTEPl l } 4l 60l04/96l lE l l l l00000l l l l lTBPl l l ' 14l 60l04/56l lBl l l l00000l l l l lTEPl j 16l 60l04/96 l 1B l l l l00000l l l l lTBPl l 54l 60l04/9fl lB l l l l00000l l l l JTBPl l 56l 60l04/96l lB l l l l00000l l l l (TBPl

  • l 86l 60l04/S6]

lE l l l l00000l l l l lTEP) l 15] 61l04/9 6 l lE l l l l00000l l l l l TSP) l 17l 61l04/56l lR l l l l00000l l l l lTBPl l 63l 61l04/56l lB l l l l00000l l l l lTBPl l 73l 61l04/56l lB l 1 l l00000l l l l lTBPl l 31l 61l04/96) lE l l l l00000l l l l lTEPl l 121l 61l04/56] lE l l l l00000l l l l lTEPl l 10l 62l04/96 l lE l l l l00000l l l l lTBP] l 18l 62 j04/56 l lE l l l l00000l l l l l TSP l l 24l 62l04/f 6l lB l l l l00000l l l l lTEPl l 80l 62l04/96l lE l l l l00000l l l l lTBP) l 75l 63l04/56l lB 1 l l l00000l l l l lTBPl l 81l 63l04/76l lE l l l l00000l l l l lTBPl l 103 l 63l04/96 l lE l l l l00000l l l l lTEPl l 121l 63l04/y6 l lB l l l j00000l l l l (TEPl l 18l 64l04/9 6 l lE l l l l00000l l l l lTBP] l 86l 64l04/76l }E i l l l00000l l l l lTBPl l 63j 65l04/$6l lE l l l l00000l l l l lTBP l ' l 46l 66l04/56i lE l l l l00000l l l l lTBPl l 86l 66l04/$6 l lE l l l l00000j l l l lTBPl l 102l 66l04/96) lE l l l l000001 l l l lTBPl l 106 l 66l04/96 l lE l l l l00000l l l l lTBP) l 27l 67[04/56 l lB l l l l00000l l l l lTBPl l 43l 67l04/56l lB l l l l00000l l l l lTBPl l 77l 67l04/56l lE l l l l00000l l l l lTSPl l 81l 67l04/56 l lE l l l l00000l l l l lTBPl l 103l 67l04/96 l lB l l l l00000l l l l lTBPl l { 76l 68l04/96l lE l l l l00000l l l } l TSP l l 88[ 68l04/56l lE l l l l00000l l l l lTBPl l 96l 68l04/56l lE l l l J00000l l l l lTEPl l 106l 68l04/96 l lE l l l l000p0l l l l l TSP l l 39l 69j04/96l lB l l l l000 '0l l l l lTBPl l

81) 69l04/96l lB l l

l l00000l l l l lTBPl l 85l 69l04/961 lB l l l l00000l l l l lTBPl l __1__1 I lI I l__I I I ( l _ __ L __l._. L ___ ROCERIDGE TECHNOLOGIES i

CUMULATIVE REPORT 00/96, BGE, CnLVERT CLIFFS, UNIT 1 STEAM GENERATOR i Il PAGE: 4 OF 8 OUTAGE DATA SET CURRENT DATE 06/14/96 SELECTION VARIABLES Percent TIME: 10:10:19 ? l \\ l 1 I l ExAMI i ! EXAM EXTENT l l l l j l l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL l0EGl % lCH lCHNGl l__1__ I 1 l_I I L_I I I I l --_ l --_. l _ I _ l -.__ l l 87l 69l04/96l lBl l l l00000l l l l l lTBPl l l l121l 69l04/96l lN l l l l00000l l l l l lTBPl l l l 86l 70l04/96l lHl l l l00000l l l l l lTBPl l l l l102l 70l04/96l lB l l l l00h00l l, l l l lTEPl l l l106l 70l04/96l lHl l l l00000l l l l l lTBPl l l l l 77l 71l04/96l lHl l l l00003l l l l l lTBP) l l l121l 71l04/96l lHl l l l00000l l l l l lTEPl l l l 701 72l04/96l lB l l l l00000) l* l l l lTBPl l l l110l 72104/96l lH l l l l00000l l l l l lTBPl l l l112l 72l04/96l lHl l l00000l l l l l lTBPl l l l l 52l 74l04/96l lH l l l l00000l l l l l lTBPl 'l l 'l 54l 74l04/96l lHl l l l000001 l l l l lTBPl l l l 961 74l04/96l lH l l l l00000l l l l l lTBPl l l l 98l 74]Q4/96l lH l l l00000l l l l l l'78P l l l l 81) 75l04/96l lH l l I l00000l l l l l l TOP! l l l 87l 75]04/96l lHl l { l00000l l l l l lTBPl l l l2031 75j04/96l lNl l l00000l l l l l lTBPl l l 1123l 75l04/96l lHl l l00000l l l l l lTBPl l l l 521 5]C4/96l lH l l l00000l j l l lTBPl l l l 72l 76l04/96l lH l l i l00000l l l l l lTBP] l l l 88l 76l04/96l lH l l l00000l l l l l lTBPl l l l100] 76lD4/96l lH l l i l00000l l l l 1 lTBPl l l l104l 76l04/96l lB l l l00000l l l l l lTBPl l l l l103) 7?l04/96l lH l l 3 l00000l l l l l lTBPl l l l1231 77l04/96l lM i l l00000l l l l lTBPl l l l 70l 78l04/961 lH l l l00000J l l l lTBPl l l l 74l 78l04/96l lNl i l00000l l l l lTBPl l l l 961 78j04/96l lH l l l00000l l l l lTBPl l l l1021 78l04/96l lH l l l00000l l l l lTEPl l l l106) 78104/96l lH l l l00000) l l l l lTBPl l l l108l 78l04/96l lHj l l00000l l l l l lTBPl l l l128l 78lO4/96l lH l l l00000l l l l l lTBPl l l l 81] 79l04/96l lH l l l l00000l l l l l lTBPl l l l 91! 79l04/96l lH l l l l00000l l l l l lTBPl l l l123l 79l04/96l lH l l l l00000l l l l l lTBPl l l l 72l 80l04/96l lH l l l l00000l l l l l l TSP l l l l 74l 80l04/96l lH l l l00000l l l l l lTBP] l l l108l 80l04/96l lM l l l l00000l l l l l lTBPj l l l 41] 81l04/96l lH l l l l00000j l l l l lTBPl l l l 71l 81l04/96l lH l l l l00000l l l l l lTBPl l l l 73l 81l04/96l lM l l l l00000l l l l l lTBPl l l l l103l 81l04/96l lH l l l00000l l l l l lTBPl l l l 70l 82l04/96) lB l l l00000l l l l l lTBP) l l l 84l 82l04/96l lH l l l l00000l l l l l lTBPl l l l 53] 83l04/96l lH j l l l00000) l l l l lTBPl l l l _ I ___ l l.__ l 1 L_I l l 1 l_l _!_ _l _i _ l l RCCKRIDGE TECHNOLOGIEC

CLNULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 5 OF 8 OLTTAGE EATA SET

CURRENT DATE:

06/14/96 SELECTION VARIABLES: Percent TIME: 10:10:19 l l l EXAM l l l EXAM EXTENT l l l l l j l ROW lLINl DATCl HEAT #l LEG lFROGRAMl ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_L l i L_l l l __ I I l 1 L_ l-_._ L_ I __ I __ I l 59l 43l04/96l lB l l l l00000l l l l l lTBPl l l l 75l 83l04/96l lHl l l l00000l l l l l lTBPl l l j l 87l 83l04/96l lM l j l l00000l l l l l lTBPl l l l 70] 84l04/96) lE l l l l0d000l l, l~ l l lTBPl l l l 73l 84j04/96l lB l l l l00000l l l l l lTBPl l l l 74l 84l04/96l lE l l l l00000l l l l ] [TBPl l l l l 78) 84l04/96l lM l l l l00000l l l l l lTBPl l l l104l 84l04/96l lH l l l l00000] l* l l l lTBPl l l l 71) 85l04/96l lE l l l l00000l l l l l lTBPl l l l 81l 85l04/96l lE l l l l00000l l l l l l TSP l l l I l1031 85l04/96l lE l l l l00000l l l l l lTBPl l l l 52l 86l04/96l lH l l l l00000l l l l lTBPl l l l 60l 86l04/96l lN l l l l00000l l l l lTBPl l l l 70l 86l04/96l lHj l l l00000l l l l lTBPl l l l128l 86l04/96l lM l l l l00000l l j l [TBPl l l l 59l 87l04/96l lH l l l l00000l l l [ lTBPl l l l 69l 87l04/96l lH l l l l00000l l l l lTBPl l l l 71) 87l04/96] lH l l l l00000l l l l lTBPl l l l 73l 87l04/96l lH l l l l00000l l l l lTBPl l l l 77l 87l04/96l lH l l l l00000l l l l lTBPl l l l 79l 87l04/96l lH l l l l00000l l l l lTBPl l l l103l 87l04/96l lH l l l 100000l } l l lTBPl l l l105] 87l04/96] lH l l l l00000l l l l lTBPl l l l123l 87l04/96l lH l ) l l00000l j l l lTBPl l l l 96l 88l04/96l lH l l l l00000l 1 l l lTBPl l l l100l 88l04/96l lH l l l l00000l l l l lTBPl l l l 83l 89l04/96l lH l l l l00000l l l l lTBPl l l l101l 89l04/96l lH ! l l l00000l l l l lTBPl j l l103) 89l04/961 lH l l l l00000l l l l l TSP) l l l1331 89l04/96l lH l l l l00000l l l l lTBPl l l l 76l 90l04/96l lH l l l l00000l l l l lTBPl l l l 78l 90l04/96l lH l l l l00000l l l l lTBPl l l l108l 90l04/96] lE l l l l00000l l l l lTBPl l l l 67l 91l04/96l lH l l l l00000l l l l l TSP] l l l 71l 91l04/96l lH l l l l00000l l l l lTBPl l l l 83l 91l04/96l lE l l l l00000l l l l lTBPl l l l 87l 91l04/96l lH l l l l90000l l l l lTBPl l l l 91l 91l04/96] lH l l l l00000l l l l lTBP) l l l 56l 92l04/96l lH l l l l00000l l l l lTBP] l l l 66l 92l04/96l lN l l l l00000l l l l lTBPl l l l 67l 93l04/96l lM l l l l00000] l l l lTBPl l l l 73l 93l04/96} lH l l l l00000l j l l lTBPl l l l 91l 93l04/96l lH l l l l00000l l l l lTBPl l l l 951 93104/96l lH l l l l00000l l l l lTBPl l l l125l 93l04/hl lH l l l l00000l l l l lTBPl l l l __._ l._._. I 1 l _l l I _._. I I I I I_ _ L.- l._- I t _ l ROCKR1DGE TECHNOLOGIBS

~, n ~ CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

6 OF 8 OtTIAGE DATA SET CURRENT DATE: 06/14/96 SELECTION VARIABLES: Percent TIME: 10:10:19 i l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATElHEATNlLE0l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lCEGl % lCH lCJC4Gl l_j-l l l_I l l_I I I 1 l_l- _l_ l_I_I l139) 93l04/96l lHl l l l00000j l l l l lTBP] l l l 64l 94l04/96l lH l l l l00000l l l l l lTBPl l l l 70l 94j04/96l lHl l l l00000l l l l l lTBPl l l l 72l 94l04/96l lHl l l l00000l l l l l lTBPl l [ l 85l 95l04/96l lHl l - l l00000l l l l l l TSP l l l l105] 95l04/96l lH l l l l00000l l l l l lTBP) l l l139l 95l04/96l lHl l l l00000l l l l l l TSP l l l j l 60l 96l04/96l lH l l l l00000l l' l l j lTBPl l l l 69] 97l04/96l lMl l l l00000l l l l l lTBPl l l l129l 97104/96l lHl l l l000001 l l l l lTBP) l l l 44l 98l04/96l lHl l l l00000l l l l l lTBPl -l l l 35j 99l04/96l lHl l l l00000l l l l l lTBPl l l l 69l 99l04/96l lH l l l l00000l l l l l lTBPj l l i ] 70l100iO4/96) lH l l l l00000l l l l l lTBPl l l l 80l100l04/96l lHl l l l00000l l l l l lTBPl l l l 82l100l04/96l lH l l l l00000l l l l l lTBPl l l l 92l100l04/96l lH l l l l00000l l l l l lTBPl l l l 94l100104/96l lH l l l l00000l l l l l lTBPl l l l 96l100r04/96l lH l j l l00000l l l l l l TSP l l l l106l100l04/96l lH l l l l00000l l l l l lTBPl l l l 45l101l04/9sl lH l l l l00000l l l l l lTBPl l l l 91l101104/96l lH l l l l00000l l l l l lTBPl l l l105l101iO4/96l lH l l l l00000l l l l l lTBP) l l j l 28l102l04/96l lN l l i

  • 0000l l

l l l lTBPl l l ] l 52l102104/96l lH l l l l 00 0.'0 l l l l l lTBPl l l l112l102 04/96l lNl l l l000001 l l l l lTBPl l l l105l103:04/96l lH l l l l00000l l l l [ lTBPl l l l 38l104-04/96j lH j l l l00000l l l l l lTBP] l l l100l104.04/96( lH l l l l00000l l l l l lTBPl l l l104l104l04/96l lH l l l l00000l l l l l lTBPl l l l128[104:04/96l lH l l l l00000l l l l l lTBPl l l l134l104104/96l lH l l l l00000l l l l l lTBPl l l l 92l106604/96l lH l l l l00000l l l l l lTEPl l l l130l106l04/96l lNl j l l00000l l l l l lTBPl l l l 21l107iO4/96l lHj l l l00000l l l l l lTBP] l l l 81l107l04/96l lH l l l l00000l l l l l lTEPl l l j105l107:04/96l lH l l l l00000l l l l l lTBPl l l l 58l108iO4/96l lH l l l l00000l l l l l lTBPl l l j 49l109!04/96l lH l l l l00000l l l l l lTBPl l l l105l109iO4/96l lE l l - l l00000l l l l l lTBPl l l l123l109!04/96l lHl l - l l00000l l l l l lTBPl l l l129l109!04/96l lH l l l l00000l l l l l lTBPl l l l 56l110f04/96l lH l l l l00000l l l l l lTBPl l l l 64l110104/96l lH l l l l00000l l l l l lTBP] l l l 68l110;04/96l lH l l l l00000l l l l l lTBP] l l l_l_I l l __ l 1 l_I I I I l_l l_I_I_I ROCKRIDGE TBCHNOLOGIES

n. .anw ~ > - ~ - -. + + - - - ' - ~"* ~~ CUMULATIVE REPORT e4/s6, BGE, CALVERT CLIFFS, tJNIT 1 STEAM GENERATOR

11 PAGE:

7 OF e OUTAGE DATA SET' 4 CURRENT DATE 'e6/14/s6 SELECr*0N VARIABLES: percent TIME: lo:2 h 3 s I. l I Ex^MI 1 l cxAM cxTENT l l l l l l l ROW lL*Sl DATElHEATNl LEG leROGRAMl ACI'UALIEXej CAL teROBEl, LOCATION l VOLTS lMILjDEGl % lCH lCHNGl i L-_.L I l' L_._ l 1 l_I i 1 I l_ L._f _ L l.- I se ptolo4/esl 1a1 l I lococol l l l l Incl.IJ l s pashtolo4/sst inl l - I loooool 1 l l l Inel l l ] Itaspiolo4/ssl lml.- 1 I loooool I l 1.l lnel I l 1 s2ptilo4/ssi lul I l losiocol l l l .I lnel l l l n ntilo4/ssi lm( I loooool l* l t 1 Inej .l l I patpsilo4/nl Ixl l I locoool s l l 1 l lnel I l 11: situ lo4/ssi Iu1 1-1 joooool l l 1 l lnel l l I saptalo4/ssi ia1 l l loooool l' l I l Inci 1 'l se ptalo4/ssi inl l I-loooool l l l l Irsel l l I se ptato4/ssl inl l-I loooool l l l Irael l l ] I sentales/nl Ia1 1 l loooool l I I l lrsel - l l Inoptalo4/nl Ia1 l l. loooool l I i l Irmel 1 l { paspulo4/nl lul l l locoool l l l l Iraej i l I sapi4 to4/ssi inl l l -loooool l l l l ITsej l l l sol124lo4/ssl lN l l l joooool l l l l lrnel l l l e4 pt4lo4/n l Inl I-- l loooool l l l 1 Irael l 1 ) i sain4lo4/ssi lul l I locoool i I l l Irsel l l l e4j114lo4/ssj jHl l l l coco 0l 'l l l l lTsel i j pas p z 4 io4/n l - lul l I loooool l l l l Irmel. l. I j 42o pu l o4/ss i - laI. - 1 I loooool l l l l Irmel l l ) l s pis t o4/n l Ia1 1 l loooool l l l l lrnel l l. j i 47pu jo4/nl Ia1 l -- I loooool i I l l Irsel l l j i n uts;o4/ssl Ia1 l I lococo! l l l l Irmel l _1 j isospistos/nl lxl 1 l loooool -l .I l l trarl I l-luonato4/nl I n l' 1 l loooool. ! l l l lrsel l l I s l1H ;o4/ssl. lH l l loooool l l l l lrsel l-l j l i sol u ste</n l iu! l l 100o001 l l l l Irsel l l J natsio4/nl i nI l I loooool l I I I lrnel l l p 4puto4/nl lul l I locoool l l l l Irael l l l1osl117jo4/ssl jHl l l joooool l l l l lTapi l l 1 ssin s.o4/ nl inl l I loooool l I I l Irael l [ t populo4/nl 1al l l loooool l l l l lrsel 1 1 jumptsio4/nl l u l. l l tococol I i l l Irsel l l l tolucio4/nl Inl l l loooool l l l l Irsel l l 4:4psolo4/ssi inl l I loooool l 1 l l Irmel-l l povp ulo4/ssi inl l I loooool I I l l lrsel l l lnonzalos/nl Ial l I loooool 1 l l l Irsel l l t spn:o4/nl In1 l loooool 1 i l l lisel l l I l ssputo4/ssl .I a 1 l l loooool l I i l lrsel l I I spas!o4/nl lul l l locoool r l I l lisej l l l ss pas o4/ssi lul l l loooool i l 1 I trael l t s 1 u pasio4/nl -l x l l l loooool l l l l Irmel l l potiustos/ssi lul l I loooool l l l 1 Irael l I punasio4/ut Ial 1 l loooool I ( l I trnal l I hisinslo4/nl ln1 1 l loooool I l 1 l Irmet l I L_ l_ _ I l l _._ I I L._.I I I i l _ l_ L._ l_ I I ROCKRIDGE TECHNOLOGIES

2 CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE:

8 OP e OUTA0E DATS BET

CURRENT DATE:

06/14/96 SELECTION val (IABLES: Percent TIME 2 10:10:19 I l l l EXAM l l l EXAM EXTENT l l l l l l lROWjLINi DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION lVOLTSjMILlDEGl % lCH lCHNGl l-.__ l- _ l l _ _I___I I l_l l 1 l l __ I __. l__ l_ _ l __ l l I esl127l04/96l lHl l l l00000l l l l l (TBPl l l i l103l127l04/96l lH l l l l00000l l l l l lTBPl l l l10$l127l04/96l lHl l l l00000l l l l l lTBPl l l l1131127l04/96l lH l l l l0v000l l l l l lrBPI l l l 90112:104/96l lHl l l l000001 j l l l lTBPI l l l 92l128l04/96l lHl l l l00000] l l l l lTBPl l l S l114112:104/96l lHl l l l000001 l l l l lTL,1 l l 1 l 95!129l04/96) lH l l l l00000l l* l l l lTBPl l l ) l113i129l04/96l lH l l l l00000l l l l l lTBPl l l l 99l131l04/96l lHl l l l00000j l, l l l lTBPl l l j l 924132104/96l lHl l l l00000l l l l l lTBPj -l l { l 9 133l04/961 lH l l l l000001 l l l l lTBPI l l l102'134l04/96l lH l l l l00000l l l l l lTBPl j l l 66<136l04/96l lH l l l l00000l l l l l lTBPj l j l 74 138104/96l lH l l l l00000l l l l l l TSP l l l l s2 13e]04/96l lH l l l l00000l l l l l lTBPI 1 l l 98 140l04/96l lH l l l l00000l l 1 l l lTBPl l l l100 140l04/96l lH l l l l00000l l l j l jfBPl l l l 25 141]C4/96l lH l l l l00000l l l l l lTBPl l l I l 83 145l04/96l lH l l l l00000l l l l l lTBPl l l l 19 147l04/96l lH l l l l000001 l l l l lTBP) l l l l 73 153l04/96l lH l l l l00000) l l l l jTBPl l l l 36 164]C4/96l lH l l l j00000l l i l l lTBPl l l l 16 166l04/96l lH { l l l00000l ' l l l l lTBP] l l l 15 167l04/96] lH l l l l00000) l l l lTBPl l l l _. _ l l l_l l l_l l l l l_I l_l_l_l NO2IR OF TUDES SELECTED FROM CUkREffr OUTAGE: 340 j ND3IR OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 340 NO 3END ANALYSIS REQUESTED CATA SELECTION CRITERIA: Per ent: TBP RTP KT OPTIONS: On'y examination results mat ching criteria are included l l l a 4 1 4 ROCKRIDGE TECHNOLOGIES 1

. ~ - . ~ .n CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGEs 1 OF 1 OtTTAGA DATA SET CURRENT DATE: 06/06/96 SELECTION VARIABLES: Percent TIME: 21:09:15 j.. l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS lMILjDEGl % lCH lCHNGl l __. l.___ I I l_I I L _I I I I L _I _ L__L._L _I l 75l 15l04/96l l C lTEC-TEHlTEC-TEHj l00025l580ULlTSH+ 0.00 l 0,89l l 0lNRHl 2l l -l100l 26l04/96l l C lTEC-TEHlTEC-TEHl jo0028l5800LlTSH+ 0.00 l l l lNRHj l l l100l 28]O4/96l l C lTEC-TEHlTEC-TEHl l 00'028 l 5 8 00L l T,SH+0.00 l l l lNRHl l l l l102l 28l04/96l l C lTEC-TEHlTEC-TEHj l00029l580ULlTSH+ 0.00 l 3,13l l 0lNRHl 2l l l119l 87l04/96l l C lTEC-TEHjTEC-TEHl l00087l581ULlTSH. 0.60 l 7.66l l 0lETL) 2l l l 47l 91l04/96l l C lTEC-TEHlTEC-TEHl l00072l580ULjTEH+ 20.62 l69.16l l183lETLl '2 l l l139] 93l04/96l lC lTEC-TEHlTEC-TEHj l00089l580ULlTSH+ 0.00 l l l lNRHl 2l l l139] 95l04/96l l C lTEC-TEHjTEC-TEHl l00089l580ULlTSH+ 0.00 l l j lNRHj 2l l l 22l166l04/96l lC l TEC-TFJij TEC-TEH l l00051l$80ULlTSC+ 0.00 l l l lNRCl 2l l l_i_I I l_1 I l __ l l I l_ L l_L_.l_1 NUMBER OF TUBES SELECTED FROM CURRENT OUTAGE: 9 NUMBER OF DATA RECORDS SILECTED FROM CURRENT OUTAGE: 9 NO TREND ANALYSIS REQUESTED ~ DATA SELECTION CRITERIA: Percent: ETL,NRO,NRH REPORT OPTIONS: Only examination results matching criteria are included I l ROCERIDGE TECKNOLOGIES l

---~ --~ .~.-- . ~~- ~n a -. -. ~ --.,n- _~, ~. t I i ) CUMULATITfE REPORT e4/96, BGE, CALVERT CLIrrS, UNIT 1 { l STEAM CENERATOR s 11 PAGE: 1 Or 5 OUTA0E DATA S C

CURRENT DATE:

os/o6/96 l-SELE M1oN VAR

  • ABLEST Indication Location. Percent TIME:

23:36:2s l l. i ExAr l l Exam EXTENT l l l l l l l row LINl DATE: HEAT #l LEG l PROGRAM l ACTUAL lExPl CAL l PROBE l LOCATION IVOLTSlM nlDEGl % lCH lCHNGl { i L_. w.-_t LI l LI i 1 _l L L_.l_ L_ L_l { I si slo 4/ss' l c lose csalose-ossl2 loo 13slssoPsivu+ 1.7s l 1.74l l.sisulP 21 l I n: ulc4/ss I a loss-vu losa a l12 loe,s sissonlo7m+ 24.se l o.ssl lo.21sAIlP 4l l i i ni 23lo4/ss; l m losa-vu less-vu ln loots 71ssorPIDs + u.nTo+ 2o.nl e. sol lo.slxsslP 41 l 1 lo: as j o4/n - l c losc-osslosc-ossl2 - loon 2lss,oPsivu - c.o2 l o.27l jo.sisAZIP 1l l l l1ol, 21lo4/n. I a lo4u vu loen-vu 17 lco434lssorPjota+ s.ss I o.ssi lo.2lsulP 4l l j j ss? 32lo4/ss l N jo4M-vu jo4E-vu l7 joo273lssorPjo,sN+1s.2s l o.74l lo.2lSAZjP 4l l l ss 34lo4/ss l n loss-vu losa-vu l12 loos 371ssonlDu + u.ono+ 1s.41l o.stj lo.2lxsIjP 41 l l 1 ss 37lo4/n l u losa.osajoss-osal loolsslsooDPloss+ o.34 l o.esl lo.sjsutP 4l l l s4 4alo4/ss lN losa.vu losH-vu ln jo07s2lssorPlDIf + 4.4s l o.s4l jo.2lsAIlP,4l j l s2 actos /n I a loen-vx loon-vu l7 loo 2ssissonloss+ 2.ssTo+ n.s5l o.42l lo.3lxstlP 4l l l lo4/n .l n loem-vu lo4a.vu 17 loo 2 3lssorPlva + 7.37to+ 11.ssi o.s2l lo.slxsIIP 4! l i l1os 41lo4/ss lE lo4H-vu jo4H-vu l7 joess3lssorPlvE+ 3.33 l c.37l !o.4lsAIlP 4l l [ l11s 41lo4/n lN jo4H-vH lo4H vE l7 lco5 3lssorPlDH + lo.s7 l o.4sj 'o.4lsAIlP 4l l l2,o4 42lo4/ss lH lo48.vu lo4H-vu l7 loDss4lssorPjo7E+ Is.s7 l o.35l !o.2lsAIlP 4! l lies 42lo4/ss I a lo4n.vu lo4a-vu 17 jooss3lssorPlDH + 2.21 l 1.2sl !o.4lsu lP el l l lies 42lo4/n l u losa.osalosa.osait loelssl slope losE. o.o1 l o.2aj !.3lsMlP 4 l l i i s eslo4/n l e losc-osalose.esul2 joo14s!ssoPalvu. 1.so l 1.sol .4lSAIlP 4e l l1o1 4slo4/ss lE jo4H.vu lo4E vu l7 lo05ssl5sorPlosE+ 2o.03To+ 23,s4l o.45l lo.4lxsIlP el l } l l1o2 < slo 4/n l n tota-vu lo4n-vn 17 joos12lssorPlva+ 4.2sTo+ s.s2l o.4sl jo.elusIlP 4[ 1 l lu2 soloofn l n loan vu jo4u.vu l7 loos u lseorPlva + s.42 -l o.44l 'o.41sulP 4! l llos s2lo4/ss lN losH vu losa.vu [7 jooss7lssorPlDH + 1s.s:To+ 17.4sl o.s3l o.2lusIlP el l l l ss s3lo4/ss. lH lo4H-vu lo4H vu ls lco4:2lssorPlo75+ 7.32 l 0.73l !o.3lsu!P 4l l l1n ssio4/n I a jo4n-vu lota vu l7 loo 73olssorPlo7s+ 17.1sTo+ 24.sel o.54l ro.3lusIIP 4l l l lo4/ss lH lo4H vu lo4H5vu [7 lco73cl5s'orPjosu+ 15.s2To+ 21.1sl o.s4l lo.2lxSIlP 4l l l' l jo4/ss l n lo4u-vu lo4u-vu 17 loo 7solssorPloss+ 1.asTo+

7. sl o.47i
o.slusIIP 4!

l ino ssio4/n l u loss-vu joss vu 17 loonalseorPlosa+ 14.osTo+ 1s.o3l o.ssi o.2lxsIjP 41 l l133 s7lo4/n lN loSH-vu jo5H-vu [7 ' loos 31lssorPjloH+ o.21 l 0.s3l l solsujP 41 l l l ss sajo4/n I u losn-vn losa-vu l7 loossalssonjva + s.s1 l o.4sl io.2lsulP 41 l l llos selo4/n lN lTse-T=nless vu 17 'icoss7lssorPlDB + 1s.2o l o.2ol

o.4lsulP 4 j l

l l .sslo4/4s lH jo4H-Vu lo4H-vu [7 joo3o71ssorPlvE, 13.so l o.ssl -lo.3lSAIlP 4l l lo4/ss I a-lva -vu lvn -vu 17 looss7lssorPlvn+ 7.71 l o.s4l lo.sisAIlP 41 l l si l-l es solos /ss l n lo4s-vu lota. m l7 loososissorPiva +.s.e4To+ lo.s2l o.3sl jo.slusIIP al l l s1 ulo4/ss l s lo4a-vn lots.vu 17 loos 4sissorPlvH + 11.s2 l o.3sj lo.2lsAIlP 4l l lin silos /n I a lc4a-vu lo4s vu 17 joovsilssorPlova+11.s1 .I o. sol lo.2lsulP 4l J l lo4/ss l n loin-vu lo4a.vu l7 lootsilssonloan+ n.o2 l o.7sl lo.sisAIIP 41 l l jo4/ss lB lo4H-vu jo4H.vu l7 loo 7s1l5sorPlosE+. s.3s l o.s4l !o.1lsAIlP 4l l l so s2lo4/n l n lo5u vu losa-vu [7 loons lssorPjvs + s.s3To.14.o41 o.s1l lo.3lxsIIP 41 l j si sslo4/ss lB jo4H-vu lo4E vu l7 lco31slssorPjvH + lo.37to+ 12.o2l o.esl lo.3lxSIlP 4l l l1o3 salo4/ss I a lo4s-vu lo4s-vu 17 loos 47lssorPIDs + 12.ss I o.asl lo.sisulP el I j l121 s3lo4/ss lB lo4H-vu lo4H-vu l7 joo757l5sorPjosE+ o.4s 'l o.sil lo.1lSujP 4l l { } es s4lo4/n l a josa-vu lo5s vu l7 loons lssorPlva + s.4sTo+ 1s.ssl o.341 lo.sjusIlP el l l ss ssio4/n I a jo4n-vu loss.vx 17 loosnissonlva + s.7sTo* 13.77l o.271 lo.sinsIjP 41 l 11o2 sslo4/n l n loen-vu lo4n-vc l7 lcosnlssorPlDs + n.soTo+ 14.nl o.sil lo.sixSIlP 4l l llos sslo4/n i n loss-osaloss-osall lcolssistoPnlcom.1s.1s l 1.ssl lo. lsulP 21 l l 43 s7]o4/ss lH losB-vu joss vu l11 lcos74lssorPlosu+ 14.s4To+ 17.3sl o.ss) ! 7slusIlp 4l l L. _ I L_I l L_-. I l l 1 l_ L-.l_l._ l_l RoCKRIDGE TECENoLoGIES I i r i i

4 CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR . 11 PACE: 2 0F 5 OUTAGE DATA SET t CURRENT DATER 06/06/y6 SELECTICN VARIABLES: Indication location, Percent TIME: 23 36:26 I. l I ExAMI l 1 EXAM EXTENT l l l l l l l ROW lLINI DATEjHEATIl LEG l PROGRAM l ACTUAL lEXPl CAL lPRODEl LOCATION l VOLTS lMILjDEGl % lCH lCHNGl l_l l i L_I I l_l l I I l __ I _ l -___ l _ l -.__ l l l l04/96l lH l06H-vM l06H-vM l11 10097415scrPl06H+ 15.70 l 0.47l l117lMSIl 11 l l all 67104/96l lH l04H-vM l04H-vM l7 l00325l5scrPivH + s.seTo+ 12.17l 0.59l 10.3lMSIlP 4l l l203l 67l04/96l l8 l04H-vM l04H-vM l7 1006311580rPlos + s.7470+ 13.68l 0.51l l0.4lMSIlP 1l l l sel 6el04/96l lH l04H-v5 l04H-vM l7 l00'327l580FPlvp +

2. 2 l 0.44l l0.2lSAIIP 41

-l l 96l 68l04/96l l H l04H-VM l04H-VM l1 l00627l580FPlVH + 5.6670+ 11.48] 0.54l l0.3lMSIlP 4l l 1106l 6:104/96l lM l04H-vM l04H-vc l7 10oe99l58hFPl095+ 5.65T0+ 13.27l 0.46l l0.5lMSIlP4l l l 81l 69l04/96l lH l048-VM l04H vM l7 l00332l580FPlVE+ 7.69T0+ 11.05j 0.33l l0.3lMSIlP 4l l l a5l 69104/96l lH l04H-vM l04H-vM 17 l0032715:0rPl0'eH+ 10.s3To+ 12.37l 0.60l 10.4lMSIlP 4l l l e7l 69l04/96l l H l04H vM 104H-vM l7 l00333l5:0rPlvH + 3.4s l 0.56l l0 <lSAIlP 4l l-l12.* 8 69104/96l lH l04H-VM l04H-VM l7 l00767l580FPl08H+ 6.1870+ 11.59l 0.29l l0.3lMSIlP 4l l l 86l M 04/96l l H l04H-VM l04H-VM l7 jo0328l580FPlVE + 3.3570+ 14.15l 0.32l l0.4lMSIlP %l l l102l 70:04/e6l l !' ! O4H.VM l04H-VM l7 l00626l580FPlDH + 13.41 l 0.50l l0.2lSAIlP 4l l .l106l 70 04/96l l H l04H-VM l04H-VM l7 l00625l500FPl09H+ 15.29 ,l 0'.48l l0.2lSA!lP 4] l l121l 71'04/96l j H l04H-VM l04H.VM [7 l00708l580FPj07H+ 6.12 l- 0.4 5 l l0.1lSAIlP 4l l j 70l 72 04/96l j H l05H-VM l05H-VM l9 l00512l500FPlVM + 0.81 l 1.02l l0.4lSAIlP 4l l l110l 72 04/96l lH l09H-09Hl09H-098l5 l00170l500PHl09H+ 0.11 l 0.77l l0.2lSAIlP 1l l l112l 72 04/96l l H l04H-vM l04H-vM l7 l00557l580rPlvB + 3.24To+ 5.36l 0.23l 10.3lMSIIP 4l l l 96l 74 04/96l lH l04n-vM l04H-VM l7 l00580l580FPlVH + 9.86 l 0.59l l0.2lSAIlP 4l l l 98l 74 04/96l lH l04H.VM l04H-VM l7 l00579l580FPl07H+ 11.28T0+ 16.96l 0.55] l0.1lMSIlP 4l l l l 04/96l lH l04H-vM l04H-vM l7 l005791580rPj0eH+ 9.81To+ 1s.67l 0.98l 10.2lMSIIP 41 l l l 04/96l l H l04H-VM l04H-VM l7 l00579l500FPl09H+ 0.00 l 0.34l }0.2lSAIlP 4 l l l l 04/96l lH l04H-VM l04H-VM l7 l00579l580FPlVH + 6.36T0+ 15.99l 0.97l l0.5lMSIlP 1l l l 81l 75 04/36l l N l04H-VM l04H-VM l7 l00374l580FPlVR + 10.72 l 0.39l l0.5lSAIlP 4l l l 87l 75 04/96l lH l04H-VM l04H-VM l7 j00383l580FPlVH +,3.24 l 0.61l l0.4lSA!lP 4l l l303l 75 04/96l lH l04H-vM l04H.VM l7 l00578l580FPloH + 9.86 l 0.62l l0.4lSAIlP 4l l l123l 75 04/96l lH l04H-VM l04H-VM l7 l00702l580FPl09E+ 2.80TO+ 3.86l 0.38l l0.6lM3flP 4l l l1001 76 - 04/96l l H l05H vM l05H-vM 17 l0057sl580rPj09H+ 4.01 l 0.45l 10.2lSAIIP 4l l l l 04/961 lB 1058-vM l05H-vM,7 l00578l5e0rPjoH + s.137o+ e.70l 0.37l l0.3lMSIIP el l l204l 76 04/96l lH l04H-VM l04H-VM [7 l00580l580FPlVR + 7.85 l 0.54l l0.2lSAIlP 4l l l103l n 04/96l l H l04H-vM l04H-vM l7 l00570l580FPloH + 6.7970+ 13.74l 0.65l l0.5lMSIlP 4l l l l 04/961 lH l04H-VM l04H-VM l7 l00570l580FPjVH + 2.17TO+ 10.78l 0.48l l0.3lMSIlP 4l l l123l 77 04/96l lH l048-VM l04H-VM l7 l00697l560FPl06H+ 8.30TO+ 23.40l 1.35l l0.3lMSIlP 2l l l l 04/96l lH l04H-VM l04H-VM l7 l00697l550FPl0$H+ 15.64T0+ 15.92l 0.84l l0.2lMSIlP 1l l l 96l 78 04/96l l H l04H-VM l04H-VM l7 l00572l580FPlVE + 2.40 l 0.49l l0.2lSAIlP 4l l l106l vs 04/96l l H l04H-vM l04H vM l7 l0057115:0rPjoH + 15.29 l 0.39l l0.2lSAIlP 4l l l108l 7e 04/96l lH toH -vM loH -vM l7 l005701580rPloH + 14.05To+ 1s.07l 0.41l 10.5lMSIIP el l l12el 78 04/96l lH l04H-vM l048-vc 17 l0069715:0rPl09H+ 0.20 l 0.61l l0.2lMAIIP 1l l l l 04/96l lH l04H-VM l04H-VC 17 l00697l580FPl098+ 0.22 l0.43l. l0.2lMAIjP 1l l l ell 19 04/96l lH l04H vM l04H-vM 17 l00392l$s0rPlvH + 10.30 l 0.0el l0.2lSAIjP 4l l -l 911 79 04/96l lH l04H-vM l04H-vM l7 l00571l580FPlVE + 3.08 l 0.36l l0.3lSAIlP 4l l l123l 19 04/96] lH l04H-VM l048-VM [7 l00914l580FPl06H+ 22.31T0+ 24.13l 0.57l l 89lMSIlP 4l l l l 04/96l lH l048-VM l04H-VM [7 l00914l580FPl095+ 3.tET0+ 5.21l 0.59l l 76lMSIlP 4l l l1081 s0 04/96l l a 104H-vM l088-oH l7 l00902l500FPj098 0.01 l 1.26l l0.2lSAIlP 4l l l l 04/96l lH l04H-VM l08H-DH l7 l00902l580FPl09H+ 0.09 l 1.25l l 60lSAIl 1l l l103l 81 04/96l lH l04H-VM l04H-VM l7 l00544l580FPloH + 8.3070+ 12.30l 0.53l l0.2lMSIlP 4l l 1_I_ l I.__ l l l_I I I I l_ l_ l_ l _ L__ I ROCKRIoGH THCHNOLOGIES

p CUMULATIVE REPORT 04/96, BGE, CnLVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 3 OF 5 OUTAGE DATA SET i CURRENT DATE 06/06/96 SELECTION VARIABLESr Indication Location, Percent TIME: 23:26:28 l l l EXAMj l l EXAM EXTENT l l l l l l l ROW lLINI DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l I4 CATION l VOLTS l MIL lDEGl % lCH lCHNGl 1._._ L I I 1._-_I 1 - 1._. ) i i _I L._.1-__ L t._.I-_- l } 84l 82l04/96l l H l04H-07Bl045-07El7 l00392l580FPj06H+ 10.19 l 0.59l l0.3lSAIlP 4l l l 87{ 83l04/96) l H l048 VM l04H-VM l7 l00392l580FFlVE + 9.90 [ 0.40l l0.2lsAIlP 1l l l104l 84l04/96l l H l098-09Ej095-09Bl5 l00176l580PHl098+ 0.01 j 0.33l l0.6lSAIlP 4l l l 81l 85l04/96l l H l045-VM l04H-VM l7 l00$98l580FPl06H+ 16.52 l 0.40l l0.2lSAIlP 4l l l l l04/96l l H l048-VM l048-VM l7 l00398l580FPl078+ 7.3870+ 13.08 l 0.37l l0.3lMSIlP 4l l l103l 85l04/96l l H l04H-VM l04H.VM l7 l00534l580FPjVE + 3.7070+ 10.94l 0.54l l1.5lMSIlP 4l l l128l 86l04/96l l H l068-07El06H-07El7 l00918l580FPl068+ 11.0070+ 15.79l 0.67l l 97lMSIlP 4} l l103l 87l04/96l lH l04H-VM l04H-VM l7 l00523l580FPlVH. 1.64 { 0.78l l0.4l5AIlP 4l l l105) 87l04/96l lH l04H-VM l04H.VM l7 l00519l580FPlDH + 7.2170+ 17.43 l 0.46 l l0.4lMSIlP 4l l l 96) 88l04/96l l H l048-VM l04H.VM l7 l00511l580FPlVE.+ 8.94 l 0.71l l0.3lSAIlP 4l l l100l 88]D4/96] l H l0ff-CiF]O9H-09El5 l00175l580PHl095+ 0.01 l 0.51l l0.7lSAIlP 4l l l 83l 89l04/96l l H l04H-VM l048-VM l7 l00398l580FPlVE + 7.69 l 0.49l l0.2lSAIlP 4l l l1011 89]C4/96l l H l09H 09Bl09H-09El5 l00175l580PHl09H+ 0.23 l 0.51l l0.2lSAIlP 4l l l103l 89104/96] l H J04H-VM l04H.VM l7 l00505l580FPjDH + 7.76T0+ 14.05l 0.41l l0.5lMSIlP 4l l l113) 89]C4/96l l H l09H-09Hl09H-09Hl5 l00175j580PHl09H+. 0.13 l 1.19l f0.4lSAIlP 4l l l108l 90l04/96l lM l04HaVM l04H-VM l7 l00505l580FPjDH + 9.5070+ 10.58l 0.37l l0.2lMSIlP 4l l l l 104/96l l H l04H-VM l04H-VM l7 l00505l580FPjvH + 5.7570+ 6.04l 0.38l [0.2lMSIlP 4l l l 83l 91l04/96) l H l04H-VM lDH -VM l7 l00456l580FPlVH + 3.78 l 0.74l 10,3lMAIlP 4l l l 87l 91l04/96l lH l04H-VM l04H.VM l7 l00406l580FPlVH + 9.58T0+ 10.01l 0.47l 10.3(MSIlP 4l l l 91l 91104/96l l H l07H-VM l07H-VM l7 l00502l580FPjVH + 2.60T0+ 11.00l 0.50l l0.6lMSIlP 4l l l 56) 92l04/96l lH l06H-VM l06H.VM l11 l00952l580FPl07H+ 14.80T0+ 16.97l 0.41ll 71lMS![P 4{ l l 66) 92l04/96l l H l06H VM l05H-DH l12 l00848l580FPjDH - 5.51 l 0.64l l0.2lSA!lP 4l [ l 911 93]D4/96l l H l04H-VM l04H-VM l7 l00493l580FPlVH + 2.91 l 0.44l l0.5lSAIlP 4l l i l 951 93]04/96l lH l08H-VM l08H.VM j7 l00484l580FPl09H+ 2.45 l 0.46l !0.2lSAIlP 4l l 1125) 93104/96{ l H l05H VM l05H-VM l7 l00643l580FPl08H+ 2.80T0+ 5,67l 0.60l l0.3lMSIlP 4l l l 85l 95l04/96l lH l04H-VM l04H-VM l7 l00407l580FPl088+ 2.07T0+ 5.46l 0.39l 10.2[MSIlP 4 l l ) l 601 96l04/96l } H l06H-VM l06H-VM l12 l00853j580FPl07H+ 9.19T0+ 16.14l 0.43l 12.1lMSIlP 1[ l 1129l 97]O4/96l lH l04H-VM l04H-VM l7 l00919l580FPl08H+ 0.61 l 0.71l l 67lSAI(P 4l l l 351 99l04/96l lH l04H-04Hl04H-04Hl1 l00155l610PHl04H+ 0.39 j 0.77l !O.3lSAIlP 4l l 1 1 l l04/96l l H [04H-04Hl04H-04Hl1 l00155l610PHl04H+ 0.90 l 0.71l l0.3lSAIlP 4l l l 92l100l04/96l l H l04H-VM l04H-VM l7 l00429l580FPjYH + 12.2170+ 21.19] 0.26l l0.2lMSIlP 4l l l 94l100l04/96l j H l09H-09El09H-09Hl5 jo0175l580PHl09H+ 0.40 l 0.31l l0.3lSAI(P 4l l l l 104/96l lH l04H.VM j04H.VM l7 l00429l580FPlDH + 2.40 l 0.56l 10.3lSAIlP 4{ l l 96l100l04/96l l H l04H-VM l04H-VM l7 l00430j580FPjvH + 6.03 l 0.51l 10.3lSAI[P 4l l l106]100l04/96l lH l04H-VM l04H-VM l7 l00429l580FPl09H. 0.01 l 0.44l l0.3lSAIlP 4l l l l l04/96l l H l04H-VM l04H-VM [7 l00429l580FPlVE + 5.79T0+ 8.80l 0.39l l0.4lMSI(P 4[ l l 45l101l04/96l l H l06H-VM l06H-VM l11 l00944l580FPl07H+ 2.44 l 0.45l l105jsAIlP 4l l l l l04/96l l H l06H-VM l065-VM l11 l00944l580FPl07H+ 2.44 l 0.60l l118l SAIL il l l 91l101l04/96l lH l04H VM lDH -VM l7 l00727l580FPlVH + 1.73T0+ 3.05] 0.44l l0.3lMSIlP 4 l l l105l101l04/96l lB l04H VM l04H-VM l7 l00425l580FPl08H+ 6.6170+ 7.96l 0.58l [0.4lMSIlP 4[ [ l105l103104/96l lH l058-VM l0$N-VM l7 l00411l580FP[078+ 2.7170+ 9.77l 0.94l l0.4lHSIlP 2l l } l l04/96l lM l0$H-VM l055-VM l7 l00411l580FPl08H+ 4.8370+ 2 0.19 l 0.55 l l 0.3 lMSIlP 4 l l l100l104l04/96l l H l04H-VM l04H.VM l7 l00727l580FPlDH + 7.07T0+ 11.84l 0.35j l0.2lMSIjP 4l l 1 1 {04/96l lH l04H-VM l04H.VM l7 l00727l580FPlVH + 2.2570+ 11.70l 0.29l l0.5]MSIlP 4l j l128l104l04/96l lH l04H-VM l04H.VM l7 l00879l580FPjDH + 13.4270+ 20.29l 0.35l l0.2lMSIlP 4l l l I___1 _1 l Li l El l 1 1 t _ L__ l _ L__. l___ l ROCKRIDGE TECHNOLOGIES

.. _ ~. - _ ~m m S,. CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 f STEAM GINERATOR t 11

pAgg, 4 or

+ OUTAGE DATA SET

CURRENT DATE:

06/06/96 SELECT *0N VARIABLES: Indication location, Percent TIMES 23:16:28 4 1 l-l l ExAMI l l EXAM EXTENT l l l l l l. l ROW lL*Nl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPj CAL lFROBEj LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l_L J l L_ l l L._ l l l l l_ _L L L_I__ _I l 92l106l04/96l l n 104s-vM l04s-09sl7 l00402l580rPl08n. 1.80To+ 18.81l 0.72l l0.5lMSIlP 4l l g l130l106l04/96l lB l04H-VM l045-VM l7 l00898l580FPl075+ 8.9070+ 14.39l 0.61] l0.2lMSIlT 4l l l 811107l04/96l l m 104m-vM l04s-vM l7 l00229l580FPjo7s+ 5.82 l 0.251 l0.2lSAIlP 4l l i ]123l109104/96l l n l04s-vM l04s vM l7 l 00452 l 580rP l 08s.17.73 l 0.44l l0.2lSAIIP 4l l l116ln0104/961 l x l04s-vM l04s-vM 17 l007521580rPIDs + 22.63 l 0.41l l0.3lSAIlP 4l l l121l111l04/96l l E l04R-VM l045 VM j7 l00752l531FPj085+ 6.55 l 0.42l l0.3lSAIlP 4l l l125l111l04/96l l H l045-VM l045-VM l7 l00752l580FPlVH + 22.50 l 0.44l l0.2lSAIjP 4l l l 86l112l04/96l lE l04H-VM l048-VM l7 l00226l580FPlYh

  • 2.51 j 0.78l l0.3lSAIlP 4l l

l 90l1u l04/96l l n 104n-vM l04s-vM l7 l00369l580rPlvu + 26.17 l 0.51l l0.3lSAIlP 1l l l110l112l04/96l lH l045-VM l045-VM l7 l00376l580FPlVH,+ 1.66 l 0.67l l0.4lSMlP 4l l l 84ln el04/96) I a l04s-vM 104r-vM l7 l00:27l580rPlvn+14.727o+18.4310.451 11.1lMSIlP 4l l l 92ln4!04/961 l n l04s-vM l04s-vM l7 1003631580rPl08u+ 3.81 l 0.31l l0.4lMAIlP 4l l j l l 104/96l l H l04H-VM lO45-VM [7 l00363l580FPlVH + 16.03 l.0.43l l0.2lMAIlP 4l l l l 94l114l04/96l l M l07H-VM l07H-VM l7 l00361l580FPlDH + 10.75 l 0.47l l0.6lSAIlP 4j l l l iO4/96l l 8 l07H VM l075-VM l7 l00361l580FPlVH + 2.9670+ 14.59l 0.32l l0.9lMSIlP 4l l .l 9ln5>04/96l l C l06C-06sjo6C-06sl2 l00158l580PHlvM - 2.95 l 0.97l l 77lSulP 4l l l124 lu s ' 04/96 l l n l04H-vM 104n vM l7 l0074sl580rPl07a+ 18.38To+ 19.80l 0.60l l0.2lMSIlP 4l l 11051117 04/961 iB l05H-vM l0$n-vM 17 l00714 580rPlDu + 15.05 l 0.46l 10.2lSAIIP 11 l l l 04/96l lH l0$H-VM l05H.VM l7 l00714l580FPlVH + 3.15 l 0.29l l0.3jSM{P 4j l l122lnt.04/961 l u l04s VM l048-VC l7 l00734l580FPj07H+ 5.2370+ 6.55l 0.58] l0.5lMSIlP 4l l l1241120l04/96l l N l04H-VH l04H.VH l7 l00771l580FPl07H+ 9.54 l 0.29l l0.3lSAIjP 4l l l1101122.04/96l lH l04H.VM l048-VM l7 l00254l580FPlDH + 13.31 l 0.50l l0.3lSAIlP 4l l l 85lus 04/96l lH l08u vM l08a-vM 17 ICO219l580rPjvH + 12.59 l 0.40l l0.2lSAIlP 4l l l 9l125.04/96l lC l06C-06Ej06C-06Hl2 l00158l580PHlVM + 0.03 l 1.25l l1.0lSAIlP 4l l l 85l125 04/96l lH l06H-08El06E-08Hj7 l00216l580FPl07H+ 15.04 l 0.63l l0.2lSAIlP 4l l l 99l125.04/96l lN l04H-VM l04E-VM l7 l002511580FPlVH + 2.43 [ 0.46l l0.1lSAIlP 4l l l101l125:04/96l lH l04H-VM l08H VM l7 l00250l580FPl08H+ 3.02 l 0.84l l0.1lSAIlP 4l l l 04/96l lH l04H-vM 104n-vM l7 l00250j580FPlVH + 5.42 l 0.53l l0.2lSAIlP 4l l l111l125 04/96l lH l04H-VM l048-VM l7 l00248l580FPl07H+ 6.28 l 0.50l l0.2 lSMlP 4 l l jn51u5:04/96l l u l03n-va l03n.vn l7 100246l580rPl08n+ 10.777o+ 21.78l 0.80l [0.1lMSIIP 4l l l 85l127.04/96l lH l08H-VM l085-VM l7 l00216l580FPjvH + 3.30T0+ 4.21l 0.80l l0.2lMSIlP 1l l l103l127'04/96l lH l04H.VM l04E VM l7 l00246l500FPlDH + 12.95 l 0.50l l0.3lSAIlP 1l ,l l105l127,04/96l lE l04H-VM l045-VM l7 l00715l580FPlDH + 11.03T0+ 13.59l 0.44l l0.3lMSIlP 4l l l113l127!04/96l lH l04E-VM l04E VM l7 l00243l580FPlDH + 3.09T0+ 4.80l 0.50l l0.9lMSIlP 4l l l 90l128104/96l lH l088 08El088-08Hl1 lv0161l610PHjo8H+ 4.82 l 0.68l l0.2lSAIlP 4l l l l

04/96l lH l08H-08Hl085-08Hl1 l00161l610PBl08H+ 5.19 l 0.32l l0.3lSAIlP4l l

l 92l128'04/96l l H l04H-VM l045-VM l7 l00238l580FPl06H+ 16.3970+ 24.06l 0.42l l0.4 lMSIlP 4 l l l l

04/96l l u l08s-09sl08n-09al4 l001801580rPjota. 21.98 l 0.33l l0.2 lSMlP 4 l l

lu3)n9:04/96l l n l04n-vM 104s-vM 17 l002411580rPIDs + 10.67 l 0.301 l2.0lMSIlP el l l 99luliO4/96l l n l08a-vM l08s-vM l7 l00:11l580rPlvH + 11.12 l 0.461 l0.2lSAIIP 41 l l 92lu2iO4/96l lE l088-VM l08E-VM l7 l00207l580FPl085+ 4.86 l 0.40]. l0.1lSAIlP 4j l l Slus;04/96l l c l06C-06al06C-06al2 l00156l580PalvM - 1.15 l 1.481 10.3lSAIIP 11 l l 741u 8:04/96] l H 104a-vM 104s-vM l9 l00589l580rPl08H+ 1.83 l 0.nl 10.2lSulP 4l l l 82l138!04/96l lH lTEC-TEHl0$H-0BEl7 l00196l580FPl06H+ 2.1670+ 19.05l 0.19l l0.2lMSIlP 4l l l l iO4/96l lM lTEC-TEHl055-08H]7 l00196l580FPj07H+ 7.7670+ 14.91) 0.27l l0.2lMSIlP 4l l Ll_ I l _l i L _l l l l l_L _ L_L _l_l ROCERIDGE TECHNOLOGIES

3 i I CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR 11 PAGE: 5 OF S { OUTAGE DATA SET s CURRENT DATE: 06/06/96 SELECTION VARIABLES; Indication Location, Percent TIME: 23:16:28 I l l l EXAM l l l EXAM EXTENT l l l l l l ) l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl ft lCH lCHNGl ) L_ L_ I I L_I I l_1 1 I I L._I _ l _ i _ t I j l l l04/96l lN l08H-VM l08H-VM l7 l00196l580FPl088+ 3.05T0+ 13.59l 0.15l l0.2lMSIlP 4l l l l l04/96l l8 lTEC-TEHl05H-08Hj7 l00196l580FPl08H+ 3.4170+ 4.61l 0.24l l0.4lMSIlP 4l l l l l04/96l lH l088-VM l085-VM l7 l00196l580FPlVH + 3.0170+ 17.30l 0.45l l0.2lMSIlP 4l l l_I_I I l __ l l l_I' I 1, I L_I_I_I_I I NUMBER OF *NBES SELECTED FROM CURRENT OUTAGE: 149 NUMBER OF DATA RECORDS SELECTED FROM CURRENT OITTAGE: 5 183 NO TREND ANALYSIS REQUESTED DATA SELECTION CRITERIA: Indication 'weationi 01H.1.00 to 01C -1.00 Percent: MAI,SAI.MSI REPORT C?""!ONS : Only examnat ion result s matching criteria are included I l 1 l i l i \\ I l 4 ROCKRIDGE TECHNOLOGIES 4

~.. ...+ ~.. ~ l i sUMULATIVE REPORT l 04/96, ALE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR t 11 PAGE: 1 OF 2 OUTAGE DATA SET CURRENT-DATE: 06/07/96 SELECTICN VARIABLES: Indication Location.. Percent TIMES 00:50:26 I 5 l i j l ] EXAM l l l EXAM EXTENT l l l l l lRDWlLINl DATEl HEATS l LEG lPROGRAMj ACTUA!lEXPl CAL !PROBEj LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l l_l_l l l_l l l,_,, ) l j._, l,,,,,,,,, j _ l,,,,,,_, j _ l l l 68l 22l04/96l l H l045-VM l045-VM [9 l00464!$80FPlDH + 5.33 l 0.74l l0.3lPPIlP 5j l l l 78) 28l04/96l l B l04H-VM l045-VM l7 l00267j580FPjo85+ 12.63 l 0.78l l0.6lPPIjP 5l l i l 68l 30l04/96l lB l04H VM l045-VM l9 {00472l580FPl07H+ 16.76 l 0.47l l0.5lPPIlP 5l l l 68l 36l04/96l l N l04H-VM l045-VM l9 l004721540FP!0pH+ 3.29 l 0.67l l0.8lPPIlP 5l. l I l l 66l 42l04/96l l N l06H-VM l06H-VM l11 l00791!580FP j 088+ 4.07 l0.68l l0.2]PPIlP 5l l l .l. !O4/96l lB l06H-VM l0CH-VM l11 l00791f 58DFP j 08H+ 7.30 l0.47l l0.2lPPIlP 5l l l 68l 42.04/96l lE l04H.VM l04H-VM l9 l00472 580FP'07H+ 1.11 l 0.42l {0.4lPPIlP Sj l l 66l 44:04/96l l N l065-VM l 06H-VM l11 l 00791 580FP ' 08H+ 1.94 l 0.83l l0.2lPPIlP Sj l l l 55l 51 04/96l lB l06H-VM l06H VM l12 l00850 580FP'DH + 2.49 l 0.80l l0.4lPPIlP 5l l j l103l 53 04/96l lE l04H-DE l04H-DH l7 l00687 580FP ; 095+ 12.53 l 1.18l l0.5lPPIlP $l l l. l '04/96] l E l04H-DH l048-DH [7 l00687,500FP 09E+ 16.53 l 0.88l l0.6lPPIlP $l l l 75l 63;04/96l lB l048-VM l045-VM l7 l00316 580FPfVE + 14.22 l 0.34l l0.8lPPIlP 5l' l ( ~{100l 76 04/96l lE l058 VM l0$H-VM l7 l00578 500FP 09H+ 12.22 l 1.09l l0.3lPFI]P 5l l l l 04/96l. l H l05H-VM l 05H-VM l7 l00578 580FP 09H+ 13.21 l 0.75] l0.2lPPIlP 5l l l102l 78 04/96l lB l04H-VM l04H-VM l7 l00573 500FP 09H+ 13.43 l 0.96] l0.2lPPIlP $l l l -l 04/96l lH l04H-VM l04H.VM 17 (00573 580FP 095+ 17.10 l 1.24] l0.2lPPIjP 5l l l l l 04/96l-lH l04H-VM l045-VM 17 l00573 580FP DH + 3.79 l 0.88l l0.5lPPI]P Sl l l .l 04/96l lH l04H-VM l045-VM !7 l00573 580FP DH + 4.75 l 0.45l l0,3lkP.tlP 5j l l 73l 81 04/96l lH lO4H-VM l04H-VM l9 l 004 97 580FP DH + 3.80 j 0.73l l0.3lPPIir 5l l l 52l 86 04/96l lN l06H-VM l06H-VM fil l00956 580FP DH + 1.50 l 1.17l l 80lPPIlP 5] l l123l 87 04/96l [H l0$H-VM l05H-VM l7 l 0 0 918 5 8 0 FP DE + 19.19 l 0.56l l105lPPIlP 5l l l100j 88 04/96l lN l04H-VM l048-VM l7 {00511 580FP 09H+ 11.55 l 1.57l l4.5lPPIlP 5l l f l'64l 94 04/96l lH l06H-VM l06H-VM (12 {00847 580FP 07H+ 22.95 l 0.27l '[0.5lPPIlP 5l l f l l 04/96l lH l06H-VM l06H VM l12 l00847 580FP 07H+ 23.83 j 0.44] l0.5lPPIlP 5l l l105l 95 04/96l lH l04H-VM l04H.VM 17 l00478 580FP 09E+ 19,76 l 0.77[ l0.8lPPIlP 5l l k l' j. 04/96l lH l04H.VM l048-VM !? l00478 580FP 09H+ 20.37 l 1.15] l0.5lPPIlP 5l l } l 80l100 04/96) lH l04H-VM l03H-VM ;7 l00414 580FP DH + 3.54 l 1.03l l0.3lPPIl 2{ l l 82l100 04/98l lH l04H-VM l03H-VM i7 100413 580FP DE + 2.55 l 1.01] l0.5lPPIlP5l l l 52l102 04/96l lB l06H-VM l07H-DE 111 l00964.580FP 07H+ 16.41 l 0.76l l 81lPPIlP 5l l l112l102 04/96l lH l04H-VH l04H-VH 17 100420 580FP 0$H+ 18.51 l 0.45l l0.7lPPIlP 5l l l100l104 04/96l lE l04H-VM l04H-VM ;7 100727 580FP DH + 3.19 l 0.75l l0.5lPPIlP 5l l l104l104 04/96] lH l04H-VM l045-VM 17 100412 580FP 09H+ 12.60 l 0.64l l0.4lPPIlP 5l l 1 l l 04/96l lH l04H-VM l04H-VM l7 l00412 540FP 09H+ 17.85 l 0.38l l0.3lPPIlP 5l l l105l107'04/96l lH l04H.VM l04H-VM j7 100396.580FP 09H+ 17.5970+ 20.76] 0.73l l0.1lPPIlP 5] l l l l 04/96l lB l 04H-VM l 04H-VM l7 l00396 580FP DE + 2.13 l1.08l l0.3lPPIlP 5l l l105l109 04/96l l H l04H.VM l045-VM 17 l00390 580FP 09H+ 19.55 l 0.49l l0.6lPPIlP 5l l l 64l110 04/96l lB l06H-VM l06H-VM l11 l 00809 580FP DH + 3.26 l 0.66l l0.5lPPI) 2l l l 68l110 04/96l lB l04H-VM l04H-VM 19 l00559 580FP DE + 4.22 l 0.52l l0.5lPPIjP Sl l l 81l111 04/96l lH l04H-VM l03H-VM 17 l00228 580FP 08H+ 13.78 l 0.53l l0.2lPPZlP 5l l l l 92l114 04/96l l N l04H VM l04H-VM l7 l00363 500FP DE + 5.13 l 0.69l l1.2lPPIlP 5l l ( l105l115 04/96l lE l045-VM l04H-VM 17 l00352 580FP 09H+ 18.76 l 0.80l l0.5lPPIlP 5l l l. l 90jl16 04/96l lH l05H-VM l05H-VM l7 l 00351 540FP DH + 5.89 l 0.64l l1.8lPPIlP 5l l l107l121.04/96] lH l04H-VM l0$H-VM [7 l00256 580FP VH + 6.99 l 0.77l l0.2lPPIlP 5l l l 85l127 04/96l lH l08H-VM l08H-VM l7 l0021f 580FP 08H+ 16.32 l 0.76l l0.4lPPIlP5l l l l 04/96l lH l08H-VM l08H-VM 17 100216 580FP DH + 4.74 l 0.79l l0.3lPPIl 2l l i L._1_ _ l L-_ I I L__i I l_ l._I _ l__I _ I ROCKRIDGE THCHNOLOGIES l 1 a

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS UNIT 1 STF.AM GENERATOR 11 PAGE: 2 OF 2 OUTAGE DATA SET

CURADrl' DATMs Os/07/96 GELECTION VARIABLES: Indication Location, Percent TIME:

00:50:26 l l } EXAM l l EXAM EXTENT l l l l l } l ROW lLINl DATEl HEAT #l LEG PROGRAM l ACTUAL lEXPl CAL l probe lIX) CATION l VOLTS l MIL lDEdj % lCH lCHNGl l _ L_ l-I l_ l_1 -1 1 I L_I_l_l_L I l 901128104/9si la 04n.vu jo u-vu 17 l00239l580FPlDE + 5.11 l 0.80l l0.2lPPIlP 5l l 1 1 104/951 Ia 08n 09Bj08H-v5 l7 l00182l580FPlDH + 5.51 l 0.19 l l.3lPPIjP 5l l l 92l128l04/9sl ls 04n-vu l04n-vu l7 l00:38l580FPlDH + 1.59 l 0.48l l0.2lPPIlP 5} l l1141128l04/9si la 04u vu l04n-vu l7 l0d242l580rP108s+ 9.90 } 0.95l l0.2lPPIjP Lj l l 95l129j04/9sl lE 04H-VM l04E-vM l7 l00238l580PPlDH + 4.00 l 1.49} l0.4}PPIlP 5l j l102l134l04/9sl lH 08H-vM l088-vM l7 l00202l5P0FPlDR + 3.79 l 0.09l {0.2lPPIlP 5l l l 98 p40l04/9sl ln 04s-vu l08a-vu l7 1003391580rPl09n+ 11.85 l 0.57l 10.2lPPIlP 51 l l1001140l04/9si la 08a-vu l08s-vu 17 100194l580rPld9u+ 12.93 l 0.stl

0.3lPPIlP 5}

l l 83l145l04/9s] lR 04H-vM l0)H-vM l7 l00318l580FPlDH + 3.68 l 0.77l }0.9lPPIlP 5} } l 73l153l04/9sl lH C5H-VM l05H-vM l9 l00597l580FPlV4 + 3.1s l 0.81l l0.4lPPIjP 5l l l _ i __ I l_ l l_l= 1 1 I l_ L_ L l_._I_I NLMER OF TUBES SELECTEC TROM CURRENT OUTAGE: 43 NLMER OF DATA RECORDS EI' ECTED FROM CURRENT OUTAGE: 55 NC 3END ANALYSIS REQUESTED 2 DA~A SELECTION CRITERIA: Ir.dication Loca:lon: 01E -1. 00 to 01C -1.00 Fe rcent : PPI REF"RT OPTIONS : 0*, m minarirn renults.atching criteria are included ROCERIDGE TFCHNOLOGIES

CUMULATIVE REPORT 04/D6, BGE, CALVERT CLIFFS, UNIT 1 STEAM cENERATOR , 22 PACE: 1 Or 22 OUTAGE DATA SET r CURRENT DATE: 06/07/96 SELECTION VARIABLES: Indication Location, Percent TIME: 00:51:36 1 1 4 1 l l l EXAMj j l EXAM EXTENT l l j l l l l ROW lLINl DATElHEATNl LEG l PROGRAM l AC WALlEXPl CAL lPRODElLOCATION l VOLTS l MIL lDEGl % lCH lCHNGl 1 j_ ] I l __ I i 1._I l l 1 l_I__l_l _ l_I i15l 5104/96l l c lTEC-TEHJTEC-TEHI l001031580Unl06H. 8.81 [11.40l l174lDNTlP1l l l 69l 13l04/96l l C lTEC-TEHlTEC-TEHl l00024l580ULlVM + J4.96 l 9.25l l179lDNTlP 1l l j 40l 14l04/96l l C lTEC-TEHlTEC-TEHj l00014l580ULlVM + 1,72 l 8.24] l174lDNTlP 1l l l 29l 15l04/96l l C lTEC-TEHlTEC-TEHj l00kC3 j580ULlVg4 - 1.26 l12.56l l172lDNTlP 1l l l 17} 19l04/961 l C lTEC-TEHlTEC-TEHl l00103l580ULl06H+ 9.43 l 8.67l l172lDNTlP 1l l j j 31l 19l04/96l l C lTEC-TEHlTEC-TEHl l00015l58DULlVM - 1.84 l10.29l jl?9lDNTlP 1l l i l 69) 19104/96l l C lTEC+TEH]TEC-TEHl l00024l580ULlDH + 6.91 l 8.71l l178lDNTjP 1l l~ l 70l 20l04/96l l C lTEC-TEHlTEC-TEHj l00025l580ULl08C+ 6.39 l 7.99l l179lDNTlP1l l l 16l 22104/96l lC lTEC-TEHlTEC-TEHl l00003l5800Ll05H+19.85 l 5.13l l178lDNTlP1l l a l 59] 23l04/96l l C lTEC-TEHjTEC-TEHl l00017l580ULlDH.+ 23.38 l 7.11l l179lDNTlP1] l l 69l 23l04/W6l l C lTEC TEHlTEC-TEHj l00025l580ULlVM + 24.15 l 7.92l l178lDNTlP 1l l j l 91l 23lC4/96l l C lTEC-TEHjTEC TEHj l00029l580ULl09C+ 1.57 l14.85l l178lDNTIP li l l 16} 24l04/96l l C lTEC-TEHlTEC-TEHl l00011l580ULl04H+ 36.52 l 5.91l l177lDNTlP 1l l 4 l 96] 24l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl03C-1.16 l 9.94l l174lDNTlP1] l l 31l 25l04/96l lC lTEC-TEHlTEC-TEHl l00017l580UL]VM - 1.90 l 8.27l l178lDNTlP 1l l l i57l25l04/96l l C lTEC-nHjTEC-TEHI l00016l580utlDH + 19.98 l17. 4 8 l l179lDNTlP 1l l l 69l 25l04/96l lC lTEC-TEHlTEC-TEHj l00024l500ULlVM + 25.40 l11.88l l172lCNTlP 1l l l 16) 26l04/96l l C lTEC-TEHlTEC-TEHl l00COl580ULl05C+ 7.42 l13.57l l178lDNTlP ll l l 72l 26l04/96l lC l TEC-nH ITEC-nHI l00025l580ULl05C+ 19.93 l25.17l l179lDNTlp 11 l l 15l 27l04/96l l C lTEC-TEHlTEC-TEHl.l00103l580ULlDC - 1.35 l 5.83l l356lDNTlP 1l l l 69l 27l04/96] lC lTEC-TEHlTEC-TEHl l00024l580ULlVM + 24.74 l 9.39l' l179lDNTlP 1l j l 49l 29l04/96l l C lTEC-TEHlTEC-TEHl l00016l5800L]DIC+ 25.05 l61.11l l174lDNTlP 1l l j 69l 29l04/96l lC lTEC-TEHlTEC-TEHj l00024l580ULlDH + 6.60 l11.501 {173lDNTlP 1l l i 1 97) 29l04/96l l C lTEC-TEHjTEC-TEHl l00028l5000Ll09H-0.35 l 8.71l l176lCNTlP 1l l l 99] 79l04/96l l C lTEC TEHlTEC-TEHj l00029l580ULl01H+ 0.00 l 5.12l l183]DNTlP 11 l l 20l 30l04/96l lC }TEC-TEHlTEC-TEHl l00011l580ULl05H+ 15.96 l 9.97l l178lDNTlP 1l l l 2Sl 30l04/96l lC lTEC-TCHlTEC-TEHl ]00011l580ULlVM + 1.06 l 8.03l l174lD!frlP 1l l l 72) 30l04/96l l C lTEC-TEHlTEC-TEHj l00025 l580ULl07C+ 23.37 l13.00l l179lDNT[P 1l l l l lD4/96l lC lTEC-TEHlTEC-TEHl l 00025 l580ULl07C+ 23.12 l13.00l l179lDNTlP 1l l j 66).30iO4/96} [C lTEC-TEHlTEC-TEHl lD0025l580ULl03H+ 0.67 l 5.51l l200lDNTlP 1l l l 96l 30l04/96l lC lTEC-TEHlTEC-TEHl l00029l5800Ll09H+ 0.24 l13.15l l181lDNTlP 1l l l 981 30l04/96l lC lTEC-TEHITEC-TEHI l00c26l580ULl09H+ 0.06 l13. 41 l l175lDNTlP 1l l j l 1sl 31l04/96l lC lTEC-nHI TEC-nHl l 000n l 5800Ll 06C+ 9.04 l 7.07l l181lDNTlP 1l l } 91l 11l04/96j l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l 8.14l l176lDNTlP 1l l l 461 32l04/96l l C lTEC-TEHlTEC-TEHl l00019l580ULlVM + 2.20 l 9.20l l180lDNTlP1l l } l 96} 32l04/96l l C l n C-TEHITEC-n Hl l00c291580ULl09H+ 0.36 l20.71l l181lDNTIP 1l l ? l 31l 33l04/96l lC lTEC-TEHjTEC-TEHl l00019l500ULlVM - 2.02 l10.47l l180lDNTlP 1l l l 47l 33l04/96l l C lTEC-TEHjTEC-TEHl l00019l580ULl02C+ 36.18 l10. 4 0 l l177lDNTlP 1l l l 691 33l04/96j l C JTEC-TEH]TEC-TEHj l00025l580ULlVM + 24.82 l 7.77l l179lCNTlP 1l l l 97l 33104/96l l C lTEC-TEHlTEC-nHl l00028l580ULl07H+ 2.92 l 6.66l l173lDNTIP ll l l-l l04/96l l C lTEC-TEHlTEC-TEHl l00026l580ULl07H+ 3.84 l16.52l l175lDNTjP 1l l l l-l04/96l l C lTEC-TEHITEC-TEHI l00028l580ULl0BH+ 0.61 l 5.24l l175lDNT[P 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00028l5800Ll08H+ 11.64 l 6.54l l175lDNTlP 1l l l l l04/96l l c lTEC-TEHlTEC-TEHl l000281580ULl09H+ 0.44 1 6.25l 1179lDNTIP al l l l l04/96l l C lTEC-TEHlTEC-TEHj l00028l500ULl07C+ 12.56 l13.90] l173lDNTjP 1l l l_ l._._ I l l _. I I L! l l l l_ j.__l __l _l _ l ROCKRIDGE TECHNOLOGIES i i

. _ ~ ~ CUMULATIVE REPORT I j 04/96, BGE, CALVERT CLIFFS, UNIT 1 i l STEAM GENERATOR 3 11 PAGE: 2 OF 22 OUTAGE DATA SET CURRENT DATE: 06/07/96 SELECTION VARIABLEO Indication Location, Percent TIME: 00:51t36 l l 1 NAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATEl HEAT #jLEGl PROGRAM l ACTUAL lEXPl CAL l PROBE l 1DCATION l VOLTS l MIL lCEOl t lCH l CHN'3 l l_._I _ I I l_l l L-_l 1 I l L._ i _ _ L-_ L_ I i i l .l l04/961 l C lTEC-TEHlTEC-TEHj 100028l580ULl07C+ 9.87 l 8.83l l175lDNTlP 1l l l l 54j 34l04/96l l C lTEC-TEHlTEC-TEHl l00019l580ULl05C+ 23.06 l14.06l l180lDNTlP 1l l l 27l 35l04/96l l C lTEC-TEHITEC-TEHI l00006l580uL103C+ 0.80 149.54l l179lDNTlP 1l l l 69l 25104/961 l C ITEc-TEHITEC-TEHI l00624l580UnivM + 25.75 111.20l l173lDNTIP 1l l ) l101l 35l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+ 0.00 l 7.96l l172]DNTlP 1l l -i } 28l 36l04/96l - l C lTEC-TEHlTEC-TEHj l00006l58bULlVM+ 3.57 l 8.72l l179lDNTlP 1l l l 40] 36l04/96l l C lTEC-TEHlTEC-TEH] l00018l580ULl02C+ 36.67 l22.27l l175lDNTlP 1l l l 41l 37l04/96[ l C lTEC-TEHlTEC-TEHl l00018l580ULlVk - 2.15 l 8.78l l174lDNTlP 1l l l 69l 3?l04/96l l C lTEC-TEHlTEC-TEHl l00026]580ULlVM + 24.58 l 7.68l l180lDNTjP 1l l l91l27l04/96i l C lTEC-TEHITEC-TEHj l00029l580usl098+ 0.00 l52.00l l174lDNTlP1l l .l 93l 27l04/96l l C lTEC-TEHlTEC-TEHj l000281580ULl09H+ 0.00 j26.01l l176lreflP ?! j i 97l 37l04/96l l C lTEC-TEHITEC-TEHl l00028]580uoj09H+ 0.00 l32.32l l178lDNTIP ll i ' 40] 38104/96l l C lTEC TEHjTEC-TEH] l00103l580ULl02H+ 33.31 l 5.53l l174lDNTlP 1l l 92l 36l04/96l l C lTEC-TEHjTEC-TEHj l00028l590ULl09H+ 0.00 l15.59l l176lDNTlP 1l l 94{ 18l04/96l l C lTEC-TEHjTEC-TEHl l00029l580ULl09H+ 0.00 l55.67l l177lDNTlP 1l l l 98l 39l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l43.29] l177lDNTlP 1l l !100l 3El04/96l l C lTEC-TEHlTEC-TEHl l00026l580ULl09H+ 0.00 l37.59l l176lDNTjP 1l l I 69l 39104/96l l C lTEC-TEHlTEC-TEHl l00026l580ULlVM + 25.11 l 7.00l l173lDNTlP1l l 91l 39j04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H4 0.00 l61.00l 1177lDNTlP1l l 93l 39l04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+ 0.00 l61.77l l176lDNTlP1l l l 95l 39104/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l57,41l l178lDNTlP 1l l l al?l 39104/96l l C lTEC-TEHITEC-TEHI l00028l580utl10H+ 0.00 l 9.02l l177lDNTlP 1l l l 104/96l l C jTEC-TEHlTEC-TEHl l00028l580ULl09C+ 18.49 l46.73l l170lDNTjP 1l l l l' l04/96l l C lTEC-TEHjTEC-TEHl l00028l580ULl09C+ 17.63 l30.91l l171lDNTlP 1l l 1 l l04/96l l C lTEC-TEHlTEC-TEHl l00028l588ULl09C+ 14.98 l23.59l l170lDNTlP 1l l l l04/96l l C lTEC-TEHITEC-TEHI l00028l580ULlD9C+ 13.78 l30.10l l171lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHj l00028l580ULl09C+ 10.87 l11,98l l170lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl lb0028l580ULl09C+ 9.32 l22.43l l174 lDNTlP 1l l l l l04/96l l C lTEC-TEH}TEC-TEHl l00026l5800Ll09C+ 8.82 l27.70l l174lDNTlP 1l l l !04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09C+ 8.34 l25.43l l172lDNTlP 1l l i l 104/96l l C lTEC-TEulTEC-TEHI luc 026l580ULl09C+ 7.87 l10.31l l171lDNTlP ll l ! 28l cl04/96l l C lTsC-TEHlTEC-TEHj l00006l580utlvM + 1.94 l 7.321 l174lDNTIP.1l l l 40j 40l04/96l lH lTEH-03HlTEH-03Hl l00169l560FLj02H+ 33.16 l82.79l l176lDNTlP lj l } 88l 4Dl04/96l l C lTEC-TEHlTEC-TEHl jo0027l580ULlVM + 20.51 l 9.54l lla2lDerTlP 1l l l 94l 40l04/96l l C lTEC-TEHlTEC-TEHl l00026l580ULl09H+ 0.03 l76.94l l181lDNTlP 1l l 1100l 4 2l04/96l l C lTEC-TEHjTEC-TEHl l00029l580ULl09H+ 0.00 l20,46] l179lDNTlP 1l l l '102 l 4 0 l 04/96 l l C lTEC-TEHlTEC-TEHl l00026l580ULl09H-0.30 l$3.07] l178lDNTlP 1l l

69l 41l04/96l l C lTEC-TEHjTEC-TEHl l00103l580ULlVM + 24.01 l 5.41]

l174lDNTlP 1l l l 91l 41l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l97.18l l176lDNTlP 1l l l 93) 41l04/96l l C lTEC-TEHjTEC-TEHj l00028l580ULl09H+ 0.12 l19.38l l162lDNTlP 1l l l 95l 41l04/96l l C lTEC-TEHlTEC-TEHl l00C29l580ULl09H+ 0.00 l71.73l l176lDNTlP 1l l l 97l 41lC4/96l l C !TEC-TEHlTEC-TEHl l00028l580ULl09H+ 0.06 l48.06l l154lDNTlP1l l 1 l 99l 41!04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l26.85l l177lDNTlP lj l l101l 41l04/96l l C lTEC-TEHjTEC-TEHl l00028l580ULl09H+ 0.03 l78.95l l181lDNTlP 1l l l i103] 41l04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l39.51l l176lDNTlP lj l !_ L_J l l_I I l_l l l l L_-. L__ l-__ L _ l _ I ROCKRIDGE TECHNOLOGIES

~- 1 CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM 3ENERATOR 11 PAGE: 3 OF 22 OlHAGE OATA SET

CURRENT DATE:

06/07/96 SELEC""*ON VARIABLES: Indication Location, Percent TIME: 00:51:36 l l l EXAM) l l EXAM EXTENT l l l l l l lROklL*Nl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L l_1 I l_t i L_l I I I L L l_l _ L._l l117) 4*l04/96l l C lTEC-TEHlTEC-TEHl jo0028l5800Ll09H+ 6.27 l 5.72] l181lDNTlP 1l l l 10l 42l04/96l l C lTEC-TEHlTEC-TEHl l00104l580ULlVM + 0.86 l13.20l l173lDNTlP 1l l l 92l 42j04/96l l C lTEC-TEHlTEC-TEHl l00029l500ULl09H+ 0.00 l45.98l l178lDNTlP 1l l l 94[ 42l04/96l l C lTEC-TEHlTEC-TEHj l 00'029 l 580UL j o,9H+ 0.00 l15.51l l179lDNTlP 1l l l 96l 42l04/96] l C lTEC-TEHlTEC-TEHj l00028l580ULl09H+ 0.03 l74.81l l182lDNTlP 1l l l 98l 42j04/96l l C lTEC-TEHlTEC-TEHl l00C29l58hULl09H+ 0.00 l117.1l l177lDNTlP 1l l l100l 42lG4/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H+ 0.00 l81.32l l181lDNTlP 1l l l102l 42l04/96; j C lTEC-TEHlTEC -TEHl l00029l580ULl09H+ 0.00 l83.77l l177lDNTlP 1l l l104l 42l04/96l l C lTEC-TEHlTEC-TEHl l00028l580UL]O9H+ 0.12 l 6.73l l180lDNTlP 1l l l106l 42lG4/96l l C lTEC-TEHlTEC-TEHl l00029j5800Ll09H+ 0.00 l31.86l l178lDNTlP 1l l l120l 42l04/96l l C lTEC-TEHlTEC-TEHl l00028l5800LlVM + 29.55 l 6.08l l178lDNTlP*1l l l 69j 43l04/96l l C lTEC-TEHlTEC-TEHl l00026l580ULl08H+ 6.73 l 6.53l l167lDNTlP 1l l l l [04/96l l C lTEC-TEHlTEC-TEHl l00026l580ULl08H+ 8.01 l 9.0Gl l168lDNTlP 1l l l i ,04/96i l C lTEC-TEH]TEC-TEHl l00026l580ULlDC + 2.23 l11.93l l*67lDNTlP 1l l l ( 04/96l lC lTEC-TEHlTEC-TEHl l 00026 l 50 0ULl 08C+ - 7.83 l 6.52l l172lDNTlP 1l l l 911 43iO4/96l l C lTEC-TEHlTEC-TEHl jo0029l580UL]09H+ 0.C0 l50.85l l178lDNTlP 1l l l l 04/96l l C lTEC TEHlTEC-TEHl l00029l580ULl09C+ 1.46 [10.86l l172]DNTlP 1l l l 93l 43 04/96l l C lTEC-TEHlTEC-TEHl l00028l500ULl09H+ 0.06 l47.08l l183lDNTlP 1l l l 9 *.# l is,04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l69.14l l178lDNTlP 1l l l 971 43.04/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H-0.06 l163,0l l178lDNTlP 1l l l 99! 41104/96l l C lTEC-TEHlTEC-TEHI l00029l580ULl09H+ 0.00 l68.02l l177lDNTlP 1l l j j l103l 43.04/961 l C lTEC-TEHlTEC TEHj l00f29l580ULl09H+ 0.00 l72.27l l177lDNTlP 1l l l105I 43.04/96l lC lTEC-TEHlTEC-TEHl l00028j580ULj09H+ 0.09 l78.31l l180lDNTlP 1l l l119l 4).04/96l !C lTEC-TEHlTEC-TEHj l000291580VLl09H+ 19.15 l11.10] l177lDNTlP 1l l l l l 04/96l lC lTEC-TEHlTEC-TEHl l 00029 l 58tJUL j 09H e 20.15 j 8.35l l176lDNTlP 1l l l l 28l 44.04/96l l C lTEC-TEHlTEC-TEHl l00006l580UL}VM 4 2.05 l12.11l l175lDNTlP 1l l l 54) 44 04/96l 1C lTEC TEHlTEC-TEHl l00023l580ULl0?H+ 15.35 l 5.10l .l177lDNTlP 1l l l 92l 44.04/96l l C jTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l95.99l l177lDNTlP 1l l 'l 99l 44,04/96l lC lTEC-TEHlTEC-TEHj l00028l580ULl09% 0.06 l125.6) ll?9lDNTlP 1l l l l 04/96[ ]C lTEC-TEHjTEC-TEHl {00028l5000Ll03C+ 1.84 l14.89l l184lDNTlP 1l l l 96l 44:04/96l l C jTEC-TEHlTEC-TEHl l00029l500ULl09H+ 0.00 l41.17l l179lDNTlP 1l l l 98l 44,04/96l lC lTEC-TEHlTEC-TLHl l00028l580ULlD9H+ 0.00 l80.26] l180lDNTlP 1l l l100l 44 04/96l l C lTEC-TEHlTEC-TEU) l00029l580ULl09H+ 0.00 l42. 64 l l178lDNTlP 1l l l102l 44 !04/96l l C lTEC-TEHlTEC-TCHl l00028l580ULl09H+ 0.00 l72.64l l182lDNTlP 1l l l104l 44104/96l lC lTEC-TEHlTEC-TEHl l00029]580ULl09H+ 0.00 l78.14l l178lDNTlP 1l l l112! 44 04/96l l C lTEC-TEHl'JEC-TEHj l00029l5800Ll09H+ 0.00 l20.74l l100lDNTlP 1l l 4 l 57j 45:04/96l l C lTEC-TEHlTEC-TEHl l00022l580ULl02C+ 9.00 l 5.71l l180lDNTl 1l l l 69l 45,04/96l l C lTEC-TEHlTEC-TEHl l000261580ULlVM + 23.00 l 5.95l l170lDNTlP Il l l 911 45'04/96l l C lTEC-TEHjTEC-TEH) l00029l580ULl09H+ 0.00 l60.77l l178lDNTlP 1l l [ l 93l 45i04/96l l C lTEC-TEHlTEC-TEHl l00028]580ULl09H-0.09 l132.2l l179lDNTlP 1l l ( l 95l 47!04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l44.24l l178lDNTlP 1l l l 97l 45t0t/96l l C lTEC-TEHlTEC-TEHj l00028l580ULl09H+ 0.00 l28.12l l181lDNTlP 1l l 'l 991 45,04/96l l C lTEC-TEHlTEC-TEHl l00029l580ULl09H+ 0.00 l33.37l l177lDNTlP 1l l l101l 45104/96l l C lTEC-TEHlTEC-TEHl l00028l580ULl09H-0.06 l32.41] l182lDNTlP 1l l l1031 45,04/96l lC lTEC-TEHlTEC-TEHj l00029l580ULl09H+ 0.00 l14.67l l178lDNTjP 1l l L_ L.__ l L_. I I LI I I i l_I_L.L_L__l ROCKRIDGE TECHNOLOGIES 4

e "m. CUMULATIVE REPORT 04/96, BCE, CRLVERT CLIFFS, UNIT 1 STEAM GENERATOR 2 11 PAGE: 4 OF 22 OUTAGE DATA SET CURRENT DATE: 06/07/96 SELECTICN VARIABLES: Indication Location, Percent TIME. C0 51:36 l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATElHEATNjLEGl PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS lMI;. DEGl 4 lCH lCHNGl L _.l _ 1 I l __ I I l_ l I i l __ _ _ I_ L._ l _ ] l105] 45l04/96l l C lTEC-TEHjTEC-TEHl l00028l580ULl09H+ 0.15 l 7.19l 181lDNTjP 1l l i l109l 45l04/96l l C l7EC-TEHlTEC-TEHl l00028l580ULl09H+ 0.15 l 9.37l 151lDNTjP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00028l580ULl04C+ 13.59 l23.55] 178lDNTlP 1l l l 28l 46l04/96l l C lTEC-TEHjTEC-TEHl l00041l580ULjVp + 2.10 l 8.30l 172lDNTlP 1l l l 40j 46l04/96l l C lTEC-TEHlTEC-TEHl l00041l580ULl05H+ 11.21 l 7.61l 172lDNTlP 1l l j ti?l 46 j 04/96l l C lTEC-TEHlTEC-TEHl l00030l58dULl09H+ 0.00 l127.4l 174lDNTlP 1] l l 94l 46[04/96l l C lTEC-TEH]TEC-TEHl l00030l580ULl09H+ 0.24 l24.37l 176lDNTlP ;l l } l 96l 46,04/96l lC [TrC TEHlTEC-TEHl l00030l580ULl09H+ 0.00 l74.29] 175lDNTlP 1l l ) l 98l 46.04/96l l C lTEC-TEHjTEC-Th.Hj l00030l580ULl09H+ 0.00 l73.00l 178lDNTlP ll l l100l 46'04/96l j C lTEC-TEHlTEC-TEHl l00030l580UL]09W+ 0.00 l52.79l 178lDNTlP ;l l l102 l 4E,04/96 l lC lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.12 l39.34l 177lDNTlP l l l110l 46:04/96l l C lTEC-TEHlTEC-TEHj l00030l5800Ll09H+ 0.15 l 5.67l 177lDNTlP l l i l114l 46 04/96j l C lTEC-TEHlTEC-TEHl l00030l5800Ll09H+ 0.12 l29.98] 178lDNTlP ll ~ l f l 41l 47 04/96l l C lTEC-TEHlTEC-TEHl l00123l580ULlVM - 1.92 l11.99l 175lDNTlP *.l l l i 69l 47 04/96l l C lTEC-TEHjTEC-TEHj l00123l580ULlVM + 24.68 l 5.66l 179lDNTlF ;l l l 91l 47 04/96l j C lTEC-TEHlTEC-TEHl l00030l580ULl09H. 0.00 l80.75l 176]DNTlP *l l l 93l 47 04/96] l C lTEC-TEHlTEC+TEHj l00030l580ULl09H+ 0.03 l91.56l 176lDNTlP ;l l 95j 4 'i 04/96] l C lTEC-TEHlTEC-TEH] l00030l580ULl09H+ 0.00 l77.*4j 177lDNTlP l l 3 l 97l 47 04/76l lC lTEC-TEHlTEC-TEHl jo0030l580ULl09H+ 0.00 l16.93l 178lDNTlP *l l l 99l 47,04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.00 l50.38l 176lDNTlP *! l l105l 47 04/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09H+ 0.00 l24.49l

77lDNTlP *l l

l115l 47 04/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09h+ 0.00 l14.51l 178lDNTlP.l l j 76l 46 04/96l l C lTEC-TEHlTEC-TEHl l00118l580ULl07H+ 5.08 l 5.42l 176lDNTlP *.I l l100l 4B 04/96l lC l TEC-TEH l TEC-TT.s l l00030l580ULl09H. 0.00 l100.1l ~77lDNTlP *.! l l102l 46 04/96l [C lTEC TEHlTEC TEHl l00030l500ULl09H. 0.00 l22.12l 178lDNTlP *.l l 1110] 46 04/96] l C lTEC-TEHjTEC-TEHl l00030l580ULl09H. 0.15 l16.38l

77lDNTlP ;{

l 1114l 46 04/96l l C lTEC-TEHlTEC-TEHl l0LO30]580ULl09H. 0.15 137.37l

78 l DNT l P - l l

1126l 46 04/96l l C lTEC-TEHlTEC-TEHj l00096l580ULlVC + 1.42 l 7.20l

  1. .BllDNTlP ll l

l 69l 49 04/96l l C lTEC-TEHlTEC-TEHl l00109l580ULlVM + 21.64 l 5.21l 177lDNTlP l 91l 4 9 04/96l lC lTEC-TEHlTEC-TEHl l00030l580ULl09C+ 1.15 l 9.09l 174lDNTlP ;) l [ 9/l 49 04/96l lC lTEC-TEHlTEC-TEHj l00010l580ULl09H-0.03 l26.81l 178lDNTlP ;l l [ 15l 49 04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.09 l37.99l 178lDNTlP ;l l l101l 4 9 04/96l lC lTEC-TEHlTEC-TEH] l00030l580ULl09H+ 0.00 l12.44l 179lDNTlP !! l l103l 49.'04/96l lC lTEC-TEHlTEC-TEHj l00030l580ULl09H+ 0.00 l19.39l 180lDNTlP *l l l105) 4 9 ! 04/96 l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.09 l 9.81] 178lDNTlP l l l109l 49;04/96l l C lTEC-TEHlTEC-TEHl l000301580ULl09H-0.09 l 5.65l

77lDNTlP *l l

l111l 49: 04/96l lC lTEC-TEHlTEC-TEHl l00030l580ULl09F 0.00 l 8.75l 179lDNTlP ;l l 1115l 49 04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.06 l24.84l

78lDNTlP ;l l

{121l 49 04/96l lC lTEC-TEH)TEC-TEHl l00030l580ULl09H+ 0.24 {13.09l 178lDNTlP ;l l l 92l 50.04/96l lC lTEC-TEHlTEC-TEHl l00031iS80ULl09H- 0.12 l24.86) 180lDNTlP *l l l l 04/96l lC lTEC-TEHlTEC-TEHl l00031l580ULl08C+ 21.19 l 6.15l 276lDNTlP *.l l l 94l 50 04/96l lC lTEC-TEHlTEC-TEHl l00030]5BOULl09H-0.06 j41.79l 182lDNTlP ;l l l 98l 50 04/96l l C lTEC-TEHlTEC+TEHl l00030l580ULl09H+ 0.00 l42.87l 179lDNTjP ;l l jl00l 50iO4/96l lC lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.00 l38.68l 180lDNTlP *l l l102l 50104/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl0!H+ 0.00 l39.43l 180lDNTlP ;l l l __ L._. l L_ l l_l 1 I I L_ _ l_ I _ !___I ROCKRIDGE TECHNOLOGIES

+, CUMULATIVE REPORT 4 04/96, BGE, CALVERT CLIFFS, CAIT 1 STEAM GENERATOR

11 PAGE:

5 OF 22 OUTAGE DATA SET i CURRENT DATE: 06/07/96 j SELEC" TION VARIABLES r Indication Location, Percent TIME: 00:51:36 i l l l EXAM) l l EXAM EXTENT l_ l l l l l l l ROW lLINl EATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL lPROBEj LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l l_i_l l l_l l l_l l l l l_l _l _l_ l _l l 91l 51l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.00 l37.94l l179lDNTlP1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 2.12 l 9.26l l177lDNTlP 1l l l 93) 51l04/96l' l C lTEC-TEHlTEC-TEHl l00030l580DLl09H+ 0.06 l75.79l l178lDNTlP 1l l l 95] 51l04/96l l C lTEC-TEHlTEC-TEHj l 00'031 l 580ULl 0,9H+ 0.06 l41.59) l180lDNTlP1l l l101l 51lC4/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09H+ 0.00 l68.16l l178lDNTlP 1l l l103l 51l04/96l l C lTEC-TEHlTEC-TEHl l00031l581ULl09H+ 0.09 l29.30l l180lDNTlP 1l l l105l 51l04/96l l C lTEC-TEHlTEC-TEHl l00030j580ULl0,9H+ 0.00 l10.91l l179lDNTlP 1l l l117l 51l04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULlDH + 8.61 l16.80) l178lDNTlP 1l l l 28] 52104/96l l C lTEC-TEHlTEC-TEHl l00045l5800LjVM + 2.73 l 5.62l l174]DNTlP Il l l 92l 52l04/96l l C lTEC-TEHlTEC-TEHj l00031l580ULl09H+ 0.09 l93.11l l178lDNTlP1l l l 94l 52j04/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09H- 0.03 l69.32l l178lDNTlP 1l l l100l 52l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.00 l99.28l l175lDNTlP 1l l l102l 52l04/96l } C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.03 .l80,61l l181]DNTlP lj l l104l 52l04/96l l C lTEC-TEHjTEC-TEHl l00031l580ULl09H+ 0.06 l36.51l l180lDNTlP 1l l l106l 52j04/96i l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.03 l19,68l l178lDNTlP 1l l l 91l 53104/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H- 0.33 l78.29] l177lDNTlP 1l l l 93) 53l04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.00 ]97.52) l178lDNTlP 1l l l 95l 53l04/961 l C lTEC-TEHlTEC-TEHj l00031l580ULl09H. 0.03 l10L9l l179lDNTlP 1l l l 991 53lG4/96l lC lTEC-TEHjTEC-TEHl. l00031l580VLl09H-0.33 l13.10l l178lDNTlP 1l l l101l 53l04/96l l C lTEC-TEHjTEC-TEHl l000301580ULl09H- 0.06 l48.13l l178lDNTlP 1] l l1031 53l04/96l l C lTEC-TEHlTEC-TEHl l00031l5800Ll09H+ 0.00 l98.93l l178lDNTlP 1l l j l105l 53l04/961 l C lTEC-TEHlTEC-TEHj l00030l580ULl09H+ 0.00 l102.8l l177lDNTlP 1] l 1107l 53104/96l-l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.06 l49.87l l179lDNTlP 1l l j l109l 53104/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.03 l34.78l 1177lDNTjP 1l l l111l 53l04/961 l C lTEC-TEHjTEC-TEHl l00031l5800Ll09H- 0.06 l23.06l 1181lDNTlP 1l l l 30l 54l04/961 l C lTEC-TEHlTEC-TEHl l00046l580ULlVM+ 4.81 l 7.21l l178lDNTlP lj l l l 921 54l04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.00 l69.82l l178lDNTlP 1l l j l 94) 54l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.09 l78.50] l180lDtfTlP 1l l l 96l 54l04/961 l C lTEC-TEHlTEC-TEHl l00030l580ULj09H-0.12 ]99.02l l182lDNTlP 1l l l 98l 54l04/96l lC lTEC-TEHlTEC-TEHl l00031l5800Ll09H+ 0.00 l45.73l l180lDNTlP 1l l l100l 54l04/96l l C lTEC-TEH]TEC-TEHl l00030l580ULl09H+ 0.03 l76.35] l179lDNTlP 1l l l102l 54l04/96l l C lTEC-TEHlTEC-TEHl l00031l580VLl09H-0.03 l120.7l l176lDNTjP 1l l l104l 54l04/96[ l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+0.12 l45.41l 1179lDNTlP 1l l l110l 54l04/96l l C lTEC-TEHlTEC-TEHl l00030l$80ULl09H+ 0.00 l12.69l l179lDNTlP 1l l l 91l 55l04/96l l C lTEC-TEHlTEC-TEHl l00031l5800Ll09H+ 0.00 l53.90l l179lDNTlP1l l l 93) 55l04/96l l C lTEC-TEHjTEC-TEHl l00030l580ULl09H- 0,03 l50.50l l177lDNTlP 1l l l 95l 55l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.15 l10.99l l100lDNTlP 1l l l 97] 55l04/96l l C lTEC-TEHlTEC+TEHl l00030l580ULl09H. 0.03 l86.40] l178lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00030l580ULl09C+ 3.85 l 6.02l l175lDNTlP 1l l l 99l 55l04/96l l C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.03 l$2.95l l179lDNTlP 1l l l101] 55104/96l l C lTEC-TEHlTEC-TEHj l00030l580ULl09H+ 0.03 l114.9l l178lDNTlP 1l l l103l 55]04/96l lC lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.06 l82.64l l179lDNTlP 1] l l105! 55l04/961 lC lTEC-TEHlTEC-TEHl l00030l5800Ll09H+ 0.06 l35.83l l180lDNTlP lj l l111l 55104/96l l C lTEC-TEHlTEC-TEH] l00031l580UL]09H- 0.06 l30.20l l180lDNTlP 1l l l113] 55l04/96} l C lTEC-TEHlTEC-TEHl l00030l580ULj09H+ 0.15 l 9.19l l177lDNTlP 1l l l_i_I I l_l l l_l i I I l_ I _ L_i_ l___l ROCERIDGE TECHNOLOGIES

-. - - -..+ I CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENEM*"OR 11 PAGD 6 OF 22 CUTAGE DATA SET r CURRENT DATE: 06/07/96 SELECTION VAA1 ABLES: Indication Location, Percent TIME: 00:51:36 l l l E'.AMl l l EXAM EXTENT l l l l l l / l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUALjEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl LLI l L._l i Ll l 1 I l -_l_ L_l__L _ l l 20j 56l04/96l l C lTEC-TEHlTEC-TEHl l00047l580ULl05H+ 31.48 l 5.32l l174lDNTlP 1l l l 26l 56l04/96l l C lTEC-TEHlTEC-TEHl l00047l580ULlVM + 1.95 l20.98l l174lDNTlP 1{ l l 74l 56l04/96l ~l C lTEC+TEHlTEC-TEHl l00119l580ULl04H+ 27.37 l 5.31l l172lDNTlP 1l l l 92l 56l04/sGl l C lTEc-TEHITEC-TEHI l00033l580utl0sH+ 0.03 135.351 l185lDNTIP $.l l l 94l 56l04/96] l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+ 0.00 l135.5l l173lDNTlP 1l l l 96l 56]C4/96l l C lTEC-TdHlTEC-TEHj l00033l58DULl09H+ 0.00 j65.00l l100lDNTjP 1l l 1100l 56l04/96l l C lTEC-TEUlTEC-TEHj l00033l5800Ll0,9H+ 0.00 l60.42l l181lDNTlP lj l r102l 56l04/96j l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+ 0.00 l19.47l l176lDNTlP 1l l .104l 56104/96l l C lTEC-TEHITEC-TEHI l00033l580uLl09H+ 0.00 171.181 lle0lDNTlP 1l l 106l 56l04/96l l C lTEC-TEHlTEC-T*.Hl l00032l580ULl09H+ 0.00 l31.37l l176lCNTlP 1l l 110l 56l04/96l lC lTEC-TEHlTEC-TEHl l00030l580ULl09H+ 0.09 l11.80l l179lDNTlP lj j ".12l 56l04/96l l C lTEC-TEHlTEC-TEHl l00031l580UL]O9H+ 0.00 l11.12l l181lDNTlP 1l l

  • 18l 56l04/96l l C lTEC-TEHlTEC-TEHl l00030l580DLl05C+ 14.54 l 5.13l l177lLNTlP 1l l

s91l 57l04/56l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.00 l37.15l l181l NTlP 1l l sal 57l04/s5l l C lTEC-nHlTEC-TEHI l 00032 l 58 00Ll 09H + - 0.00 l122.8l l174l NTlP.1] l

95) 57}04/56l l C lTEC TEHjTEC-TEHl l00033l580ULl09H+

0.09 l203.1l l184lONTlP 1l l 97l 57l04/s6l l C lTEC-nHlnC-TEHj l00032l580ULl09H+ 0.00 l131.2l l174l0NTlP 1l l +9l 57l04/56l lC lTEC-TEHlnC-TEH I l00033l580uLl09H+ 0.00 l2t.96l l181l:NTlP 1l l g U ll 57l04/s61 l C lTEC-TEHITEC-TEHI l00032l580ULl09H+ 0.00 135.81) l1761:NTlP ll l ~03l 57l04/56l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.00 l14.28l l182lDNTlP 1l l 105l 57lC4/56) l C lTEC-TEHjTEC-TEH] l00032l580ULl09H+ 0.00 l35.43l l176l?NTlP 1l l M 7l 57l04/$6l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.00 l26.57l 1181l0NTlP 1l l 1111 57l04/s6l A C lTEC-TEHITEC-TEHl lec033l580Unl09H+ 0.00 l1s.09l l182l:NTIP 11 l 40l 58l04/$6l lC lTEC-TEHlTEC-TEHl l00047l580ULjc2H+ 36.5's l52.72l l17'l[ONTlP 1l l ] l 104/96l l C lTEC-TEHlTEC TEHj l00047l580ULl03H-0.76 l10.10l l177lONTlP 1l l ) sal 58l04/s6l lC lTEC-TEHlTEC TEHl lC0119l580ULl03H+ d,60 l12.66l l1'1310NTlP 1l l 92l 58l04/96l lC lTEC-TEHlTEC-TEHl l00033l5800Ll09H+ 0.00 l30.58l !1Bil:NTlP ll l 94[ 58}04/56l lC lTEC-TEHjTEC-TEHl l00032l580ULl09H-0.06 l151.41 l176l NTlP 1l j 96l 58l04/56l lC lTEC-TEHlTEC-TEHl l00033l580ULjo9H+ 0.00 j56.46l l181l NTlP 11 l 98l 58l04/96] lC lTEC-TEHjTEC-TEHl l00032l580ULl09H+ 0.00 l57.171 l177lONTlP ll l M0j 56l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.00 l22.69l l184lDNTlP 1l l M2l 58l04/s6l l C lTEC TEHlTEC-TEHl l00032tS80utl09H. 0.00 l 7.591 1175lDNTIP 1l l 106] 58l04/96l lC lTEC-TEHlTEC-TEHl l00032l500ULl09H+ 0.00 l13.07l l176lDNTlP 1l l 112l 58l04/$6l l C lTEC-TEHlTEC-TEHl l00033l580ULlVC + 14.22 l 5.02l l181l0NTlP 1l l l 41l 59l04/96l l C lTEC-TEHlTEC-TEHl l00113l5800LlVM - 1.86 l 8.90l l171lDNTlP 1} l 91l 59l04/56l l C lTEC-TEHlTEC-TEHl l00033l580ULjo9H+ 0.00 l43 01l l181lDNTlP 1l l 93l 59l04/56l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l127.7l l173lDNTlP 1l l 95l 59l04/56l l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H+ 0.00 l65.41l l182lDNTjP 1l l 97l 59l04/s6l lC lTEC-TEHITEC-TEHI l00032l580utlc9m 0.00 l48.49l 1176lDNTlP 1l l 105l 59l04/56 l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l15.00l l177lDNTlP 1l l M 7l 59104/56l l C lTEC-TEHlTEC-TEHl l00033l580ULj09H+ 0.00 l 5.83l l180lDNTlP ll l 40l 60l04/96) l C lTEC-TEHlTEC-ten. l00047l580ULl01H+ 23.87 l 8.59l l178lDNTlP 1l l 7e] (,0I04/s6l l C lTEC-TEHlnC-nHl l001291580ULj oiH+ 28.16 l 5.08l l182lDNTlP 1l l 92l 60l04/96l l C lTEC-TEHlTEC-TEHl jo0033l580ULjo9Ha 0.12 l86.91l l184lDNTlP 1l l f4) 60l04/96l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l80.11l l175lDNTir 1l l _ L _l l L_l l l_I l l l l _ L_ L_ ! _ L._ t ROCKRIDGE TECHNOLOGIES

l I CUMUIATIVE REPORT 04/96, BGE, CAU!ERT CLIFFS, UNIT 1 STEAM GENERATC2 11 PAGE: 7 Or 22 OtfrAGE DATA SET t CURRENT DATE: 06/07/96 SELEC"10N VARIABLES: Indication location, Percent I TIME: 00:51:36 ( l l l EXAMi l l EXAM EXTENT l l l l l l -{ROWjLINj DATEjHEAT#l LEG l PROGRAM l ACTUAL]EXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl.% lCH lCHNGl l _l-_ I LI I L._ l l I I l_ L _ l._._ L L_._1 l 96l 60l04/96l l C lTEC-TEHlTEC-TEHl l00033l580ULl09H- 0.14 l71.88] l179]DNTlP 1l l i ] 98l 60}04/96! l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l57.36l l177lDNTlP 1l j i l 41l 61l04/96! l C lTEC-TEH]TEC-TEHj l00115l580ULlVM - 1.94 l11.58l l172lDNTlP1l l l 91l 61l04/96l l C lTEC-TEHlTEC-TEHl l 00033 l 580ULl 0.9H-0.33 l90.27l l177lDNTjP 1l l l l l04/96 l l C lTEC-TEHlTEC-TEHj 'l00033]580ULl09C+ 0.33 l 7.30l l357lDNTlP 1l l l 93l 61l04/96! l C lTEC-TEHjTEC-TEHl l00032l580ULl09H+ 0.00 l75.62l l174lDNTlP1l l l 95{ 61l04/96 l C lTEC-TEHlTEC TEHj l00033l5800L]O9H+ 0.06 l20.71l l185lDNTlP 1l j -l 97l 61l04/96. l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+ 0.00 l91.42l l175lDNTlP 1l l l 99l 61l04/96' l C lTEC-TEHlTEC-TEHj l00033l580ULl09H-0.22 ~l47.97l l180lDNTlP 1l l l101] 61l04/98 l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+ 0.00 l40.58l l175lDNTlP1l l l l103l 61l04/96' l C lTEC-TEHlTEC-TEHl l 00033 l 58 0ULl 0913 0.00 l 7.67l l179lDNTlP 1l l ~ l105l 61l04/96 l l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l34.4Bl l175lDNTlP lj l l107; (1l04/96 l C lTEC-TEHlTEC-TEHl l00033l580ULl09H. 0.03 l28.26l l185lDNTlP1l l l109) (1l04/96 l C lTEC-TEHjTEC-TEHl l00032l580ULl09H+ 0.00 l24.91l l174lDNTlP 1l l l113i (1l04/96 l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00, j26.12l l176lDNTlP 1l l l115! (1l04/96 l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-0.28 l15.51l l182lDNTlP 1l l l l117. 51l04/96 l C lTEC-TEHlTEC-TEH[ l00032l580ULl10C-f.03 l 9.87l l175}DNTlP al l l 92l 62{04/96 l C lTEC-TEHjTEC-TEHl l00033l580ULl09H-0.39 l46.08l l179]DNTlP 1l l l 94, {2[04/96 j'C lTEC-TEHlTEC-TEHl l00033l580ULjo9H-0.06 l27.80l l183lDNTlP 1l l l 96 (2l04/96 l C lTEC-TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l27.25l l175lDNTlP 1l l 2 l 98! 62l04/96 l C lTEC-TEHlTEC-TEHl l00033l580ULj09H-4.42 136.43l l182lDNTlP 1l l l100! 62l04/96 l C lTEC-TEH)TEC-TEHl l00032l580ULj09H+ 0.00 l80.97l l176lDNTlP 1l l l102! (2l04/96 lC lTEC TEHlTEC-TEHl l00033l580ULl09H+ 0 00 'l25.94l - l182lDNTlP 1l l l110; (2l04/96' l C lTEC-TEHlTEC-TEHl l00033l5800Ll09H+ 0.06 l21.33] l186lDNTjP 1l l -l 911 63l04/96 l C lTEC-TEHlTEC-TEHl l00033l58DULl09H-0.22 l58.51l l181]DNTlP 1l l l 1 l04/96 l C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 2.11 l 7.38l l175lDNTlP 1l l l 93' f3l04/96 l C lTEC TEHlTEC-TEHl l00032l580ULl09H+ 0.00 l88.48l l175lDNTlP 1l l l 951 f3l04/96 lC lTEC-TEHlTEC-TEHj l00033l580ULl09H-0.03 l72.73) l186lDNTlP 1l l 'l 101, i3l04/96 lC lTEC-TEHlTEC-TEHl l00032]580VLl09H+ 0.00 j74.54l l175lDNTlP 1l l l203: f3l04/96 lC lTEC-TEHjTEC-TEHj l00033l580ULl09H+ 0.25 l22.16l l143lDNTlP 1l l l105' 63l04/96 l C lTEC-TEHlTEC-TEHj l00032l580ULl09H+ 0.00 l92.81l l174lDNTlP 1l l 'l107; 63l04/96 l C lTEC-TEHlTEC-TEHj l 00033 l 590UI l 09H+ 0.03 l73.75l l184lDNTlP 1l l l1091 63l04/96 l C lTEC-TEHlTEC-TEHl l00032l580ULl04H+ 13.65 l21.10] l172lDNTlP lj l l1271 63l04/96 l C lTEC-TEHlTEC-TEHl l00095l580ULl09H+ 0.00 l 7.01l l180lDNTjP 1l l l 92t 64]D4/96 }C lTEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.09 l41,55l l185lDNTIP1l l 1 l 94? E4l04/96 l C lTEC-TEHjTEC-TEHl l00032l580ULl09H+ 0.00 l73.01l l175lDNTlP 1l l l 98i 64l04/96 l C lTEC-TEHlTEC-TEHl-l00032l580ULl09H+ 0.00 l13.92l l176lDNTlP 1l l l100? f4l04/96 l C lTEC-TEHlTEC-TEHl l00033l580ULl09H-0.03 jl26.8l l182lDNTlP 1l l l102t (4j04/96 l C lTEC-TEHlTEC-TEHl }00032l580ULl09H+ 0.00 l55.31l l177lDNTlP 1} l l104! 64l04/96 l C }TEC-TEHlTEC-TEHl l00033l580ULl09H+ 0.03 l18.71l l179lDNTlP 1l l l106: 64l04/96 } C lTEC-TEHlTEC-TEHl l00031l580ULl09H+ 0.00 l50.67l l176lDNTlP 1l l l l 57! 45l04/96 lC lTEC-TEHlTEC-TEH) l00117l580ULl02C+ 37.51 l52.49l l177lDNTlP 1l l l 91 65l04/96 l C lTEC-TEHlTEC-TEHj l00033l580ULjo9H+ 0.00 l21.13l l181lDNTlP 1l l l 93i 65l04/96 l C lTEC-TEHjTEC-TEHl l00032l580ULl09H+ 0.00 l39.97l l175lDNTlP 1l l l 97; 65l04/96 l C lTEC-TEHlTEC-TEHl l00034l580ULl09H-0.06 l34.57l l182lD1C]P 1l l L __ -_ I l_I I L__I I l_ l l_ L _l--_.l_I_ I ROCKRIDGE TECHNOLOGIES i l t i

i 1 L COMULATIVE REPORT 04/f6, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR t 11' PAGE: 8 OF 21 l OUTAGE DATA EET i CURRENT LATE: 06/07/96 j SELECTION VARIABLES: Indication Location. Percent TIMES 00:51:36 ( l 'l l EXAM l l j EXAM EXTENT l l l l l l l ROW lLINl DATEjHEA'INl LEG l PROGRAM l ACTUAL lEXPj CAL l PROBE l LOCATION l VOLTS l MIL lDEGl t lCH lCHNGl - L_l _I I l_t I L _l I i l l_i_I_i_i_I l 99l 65l04/96l l C lTEC-TEHlTEC-TEHj l00035l580ULl09H+ 0.06 l72.14j l182lDNTlP 1l l l l101l 65l04/96l l C lTEC-TEHjTEC-TEHl l00034l580ULl09H+ 0.00 l 62.4 9 l l182lDNTlP 1l l ) l103l 65l04/96l l C lTEC-TEHITEC-TEHl l00035l500utl09H+ 0.03 l55.381 1180lDNTIP 11 l j105l 65l04/96l lC lTEC-TEHlTEC-TEHl l00034l580ULl0PH+ 0.00 l67.24l l181lDNTlP 1l l j l l 92l 66l04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H-0.09 l35.32l l184lDNTlP 1l l I l 94l 66l04/96l l C lTEC-TEHlTEC-TEHl l00034l58 boll 09H+ 0.00 l 7.91) l182lDNTlP 1l l l 98l 66l04/96l lC lTEC-TEHlTEC-TEHl j00034l580ULl09H+ 0.09 l22.41l l181lDNT]P 1l l l100l 66l04/96l lC lTEC-TEHlTEC-TEHj l00035l580ULl09H+ 0.03 l 56.4 2 l l184lDNTlP 1l l l l102l 66l04/96l lC lTEC-TEHjTEC-TEHj l00034l500ULl09H+ 0.06 l 6.48) l160lDNTlP 1l l l110l 66l04/96l l C lTEC-TEHlTEC-TEHj l00034l580ULl0?H+ 22.56 l 5.931 l179lDNTlP 1l l l 91l 67l04/96l l C lTEC-TEHlTEC-TEHl l00035l580ULl09H+ 2.51 l10.28l l179lDNTlP 1l l -l 91l 67l04/961 lC lNC-TEHlTEC-TEHl jo0034l580ULl09H+ 0.00 l50.49l l182lDNTlP 3 l l l 95j 67l04/96l lC lTEC-TEHlTEC-TEHl l00035l580ULl09H+ 0.03 l54.74l l184lDNTlP lj l l l 97] 67l04/96l lC lTEC-TEHlTEC-TEHl' l00034l580ULl09H+ 0.00 l15.195 l179lDNTlP 1] l l 99l 67l04/96l lC lTEC-TEHlTEC-TEHl l00035l580ULl09H+' O.06 l32.67! l183lDNTlP 1l l l103l 67l04/96l lC (TEC TEHlTEC-TEHl l00035]5800Ll09H+ 0.06 l15.271 l187lDNTjP 1l l l105l 67l04/96l lC lTEC-TEHlTEC-TEHj l00034l580ULl09H+ 0.00 l22.78i l182lDNTlP 1l l j i 66] 68l04/96l l: iTEC-TEHITEC-TEHi l00117l580ULl04H+ 12.19 i 8.07-l180lDNTIP 11 l l 76l 68l04/961 !C iTEC-TEHlTEC-TEHI l00120l580u;l01c+ 17.16 l 6.251 l161lDNTIP 1l l l 92l 68]C4/96l l C'lTEC-TEHjTEC-TEHl l00035l580ULl09H-0.03 l36.291 (184lDNTlP 1l l l 94] 68l04/96] lC lTEC-TEHjTEC-TEHl l00034l580ULj09H-0.18 l29.67l l181lDNTlP 1l l l100l 68l04/96l lC lTEC-TEHlTEC-TEHl l00035l5BOULl09H+ 0.03 l38.09' l184lDNTlP lj l l 91l 69l04/96l lC lTEC-TEHlTEC-TEH] l00035l580VLl09H-0.09 l45.291 l183lDNTlP 1l l l 93l 69l04/96l lC lTEC TEHlTEC-TEHj l00034]580ULl09H-0.12 l43.97] l181]DNTlP 1l l l l 95l 69l04/96l lC lTEC-TEHITEC-TEHI l00035l58eULl09H+ 0.00 l63.37! l183lDNTlP 1l l l 97] 69l04/96l l'C lTEC-TEHlTEC-TEHl l00034l580ULl09H+ 0.00 l24.43! l183lDNTlP 11 l l 99] 69l04/96l lC lTEC-TEHjTEC-TEHj l00035l580ULl09H+ 0.15 l51.11: l182lDNTIP 1l l l129l 69l04/961 l C lTcC-TEHITEC-TEHI l00096l580ULl05C+ 20.90 l26.23; l178lDNTlP 1l l l 92l 70lC4/96l l C lTEC-TEHlTEC TEHl l00037l580ULl09H+ 0.06 l29.33: l177lDNT]P II l l 94l 70j04/961 lC lTEC-TEHlTEC-TEHj l00036l580ULl09H+ 0.20 l34.441 l178lDNTlP 1l l l I 961 70104/961 lC JTEC-TEHlTEC-TEHl l00035l580ULl09H+ 0.27 l10.90' l184lDNTlP1l l l 98l 7Dj04/96l lC lTEC-TEHlTEC-TEHl l00130l580ULl09H+ 0.00 l67.57l l180lDNTlP 1l l l200l 70l04/96l lC lTEC-TEHlTEC-TEHl l00035l580ULl09H- 0.C3 l49.541 l184lDNTlP 1] l l l l04/96l lC lTEC-TEHlTEC-TEHl l00035l580ULlDH + 12.95 l 8.60l l186lDNTlP 1l l l102l 70l04/96l lC lTEC-TEHlTEC-TEHj l00130l580ULl09H+ 0.00 l56.69l l181lDNTlP 1l l l120l 70l04/96l lC lTEC-TEHlTEC-TEHl l00035]580ULlVH + 3.53 l41.79I l173lDNTlP 1l l l l 104/96l lC lTEC TEHITEC-TEHI l00035l580utl08C+ 9.39 l13.06i 1179lDNTIP 1l l l l l04/961 lC lTEC-TEHITEC-TEHj l00035l580ULl06C+ 18.42 l14.08l l180lDNTlP 1l l l l 104/961 lC iTEC-TeHlTEC-TEH] l00035l580ULltm.7.36 l 6.24i l175lDNTlP ll l l 91l 71l04/96l lC lTEC-TEHlTEC-TEH] l00037l580ULjo9H. 0.03 l 8.71l l184lDNTlP 1l l l 93l 71l04/96l lC JTEC TEHlTEC-TEHl l00036l5800LlD9H-0.03 l38.78l l179lDNTlP 1l l l 95j 71lC4/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H+ 0.06 l41.36] l178lDNTlP 1l l l 97l 71l04/96l lC lTEC-TEHlTEC-TEH) l00036l580ULl09H+ 0.00 l21.61l l179lDNTjP 1l l l 99] 71l04/96l lC lTEC-TEHlTEC-TEHl l00037l580ULl09H+ 0.20 l31.61] l177lDNTlP 1l l l101l 71l04/96l lC lTEC-TEHlTEC-TEHl l00036l580ULl09H+ 0.00 l69.86) l176lDNTlP ll ] l_1_l I l __l l l-I l l l L._i_ I _ I_._i _ l ROCKRIDGE TECENOLOGIES I l

mm ._..__.--m_ .3 CUMUIATIVE REPORT 04/96, BGE, CALVERT CLIFFS, IEtIT 1 STEAM CENERATOR t il PAGEs 9 OF 22 OUTAGE DATA SET r CURRENT DATEi 06/07/96 SELECTION VARIABLES: Indication Location, Percent TIMEt 00:51t36 4 l l l EXAM) l l EXAM EXTENT l l l l l l [ l ROW lLINl DATEjHEAT#l LEG l PROGRAM l ACTUAL lEXPl CAL lPROBEj LOCATION jVOLTSl MIL lDEGl % lCH lCHNGl L__. l _1 i l_I I L__ I I I I L l._I _ i _ L __t l107l 71l04/96l l C lTEC-TEHlTEC-TEHl l00036l5800Ll09H+ 0 00 j 5.16l l180lDNTlP 1l l l l 72} 72l04/96l l C lTEC-TEHlTEC-TEHl l00116l580tElDH + 22.16 l10.65l l173lDNTlP 1l l i l 92l 72l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H. 0.09 l36.12l l178lDNTlP 1l l } l 96] 72j04/96l l C lTEC-TEHjTEC-TEHl l00037l580ULjo9H- 0.03 l 8.60l l178lDNTlP 1l l l 98l 72l04/96l l C lTEC-TEHlTEC-TEHj l00036l580tEl09H-0.16 l94.53l l179lDNTlP 1l l }100) 72l04/96l l C lTEC-TEHjTEC-TEHl l00037l580ULl09H+ 0.26 l58.00l l178lDNT[P 1l l l102l 72l04/96l l C lTEC-TEHlTEC-TEHj l00036l580ULj09H+'O.00 l 4 3.'10 l l179lDNTlP lj l j104l 72l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09H-0.03 l32.94l l178lDNTlP 1l l l110] 72l04/96l l C lTEC-TEHlTEC-TEHl l00036l580tEl09H+ 0.00 l10.351 l179lDNTlP 1l l l120l 72l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULlVC+ 4.46 il2.85l l175lDNTlP ll l l 35l 73l04/96l l C lTEC-TEHjTEC-TEHl l00048l5800LlVM + 0.00 l12.90l l181lDNTlP 1l l ), l 91) 73l04/96l l C lTEC-TEHlTEC-TEHj l00037l580ULl09H+ 0.06 l34.10j l177lDNTlP 1l l l93l73]O4/96} l C lTEC-TEHlTEC-TEHl l00036l580ULl09H+ 0.03 l76.41l l178lDNTlP 1l l I l 95] 73l04/96} l C lTEC-TEHlTEC-TEHl l00037l580UL]D9H+ 0.09 99.10l l178lDNTlP 1l l v l l l04/96l l C lTEC-TEHlTEC-TEHl l00037l580ULl09C+ 0.03 l 8.44j l175lDNTlP 1l i l 97l 73l04/96l lC lTEC-TEHlTEC-TEHj l00036l580ULl09H+ 0.06 l81.87l l178lDNTlP 1l l l 99l 73l04/96l l C lTEC-TEHjTEC-TEHl l00037l500tEl09H+ 0.12 l43.83l l183lDNTlP 1l l l 52l 74l04/96l l C lTEC-TEHlTEC-TEHl l00116l580ULl04C+ 5'.80 l19.47l l175lDNTlP 1l l l 58l 74l04/96l lC lTEC-TEHlTEC-TEHl jo0117l500ULl07H-0.72 l 7.00l l173lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00117l580ULlVM + 3.80 l 6.59) l173lDNTlP 1l l j l l04/96l l C lTEC-TEHlTEC-TEHl l00117l5800Ll06C+ 21.88 l16.02l {172lDNTlP 1l l l 92l 74l04/96l l C lTEC-TEHlTEC-TEHl l00040l5800Ll09H+ 0.03 l49.96l l176lDNTlP 1l l l 94l 74l04/96l lC lTEC-TEHlTEC TEHj l00040l580ULl09H+ 0.09 l20.93l l179lDFTTIP 1l l l2021 74]D4/96] l C lTEC-TEHlTEC-TEHl l0003Bj500(El09H+ 0.00 l14.16l l180lDNTlP 1l l l114l 74l04/96l l C lTEC-TEHlTEC-TEHl l0003Bl580tEl07H+ 8.63 l 7.91l l172lDNTlP ll l l 691 75l04/96l lC lTEC-TEHlTEC-TEHl l00117l580ULlDH+ 7.57 l 5.30l l177lDNTlP 1l l l 91l 75j04/96l lC lTEC-TEHlTEC-TEHl l00040l5800Ll09H+ 0.00 l58.19l l182lDNTlP ll l l l l04/96l lC l TEC-TEH l TE.- TEH l l00040l580tEl09H+ 1.96 l 8.10l l176lDNTlP 1l l l'93l 75l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.00 l 8.01l l180lDNTlP 1l-l l V5l 75l04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.09 l43.31l l183lDNTlP 1l l l 99l 75l04/96l l C lTEC-TEHlTEC-TEHl l00039l5800Ll09H+ 0.15 l29.08l l182lDNTlP 1l l l111] 75l04/96l

  • l C lTEC-TEHlTEC-TEHj l00039l580ULlVM + 29.04 l 8.31l l175lDNTlP lj l

t l 92l 76l04/96l l C lTEC-TEHlTEC-TEHj l00040l580ULl09H-0.15 l12.11l l177lDNTlP 1l l l 94l 76l04/96l l C lTEC-TEHlTEC.TEHl l00039l580tEl09H-0.03 l68.61l l179lDNTlP lj l l 96] 76l04/96l l C lTEC-TEHlTEC-TEHj l00039l580ULl09H+ 0.00 j29.86l l181lDNTlP ll l l110l 76l04/96l l C lTEC-TEHlTEC-TEHl l00038l580ULl09H+ 0.00 l17.62l l178lDNTlP 1l l } 41l 77l04/96l l C lTEC-TEHlTEC-TEHl l00120!5000Ll01H+ 28572 l12.53l l178lDNTjP 1l l l l l04/96l l C lTEC-TEHlTEC TEH] l00125l580ULl01}t+ 28.72 l 9.71l l178lDirTlP 1l l l 45] 77l04/96l lC lTEC-TEHlTEC-TEHl l00181l580ULjVM - 2.00 8 l 6.16l l174lDNTlP 1l l l 69l 77l04/96l l C lTEC-TEHlTEC-TEHl l00117l580tElVM + 24.78 l 5.82l l174lDNTlP 1l l l 91l 77l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H-0.09 l25.38l l179lDNTjP 1l l l 931 77l04/96l l C lTEC-TEHlTEC-TEHj l00039l580tEl09H-0.15 l33.87l l183lDNTlP 1l l j l 95l 77l04/96l l C lTEC-TEHlTEC-TEHj l00038l580ULl09H- 0.06 l58.60l l175lDNTlP 1l l l 97l 77l04/96l l C lTEC-TEHlTEC-TEHl l00039l5800Ll09H+ 0.09 l95.48l l177lDNTlP 1l l l 99l 77l04/96l l C lTEC-TEHlTEC.TEHl l00038l5800Ll0?H. 0.21 l29.81l l177lDNTlP 1l l l_I_I I l _.__ I l l_I I I I l_l _l__ L_ I I ROCKRIDGE TECHNOLOGIES

CUMULATIVE REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 FAGE: 10 OF 22 OUTAGE DATA SET CURRENT DATE:

06/07/96 SELECIZON VARIABLES: Indication location, Percent TIMEt 00:51:36 l l l EXAM l l l EXAM EXTENT l l l l l l + l ROW lLINl DATElHEATNl LEG l PROGRAM] ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L__ l._ l l L__ l - I l __. I I I I L__l __I_ l._.L__l 1 l92l*Ml04/96l j C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.03 l41.63l l178lDNTlP 1l l l 94l 78l04/96l l C lTEC-TEHjTEC-TEHl l00039l580ULl09H+ 0,00 l39.01l l180lDNTlP 1l l l 96l 78l04/96l l C lTEC-TEHlTEC-TEH) l 00039 l 580%l 09H+ 0.06 l13.65l l182lDNTjP 1l l l100l 78104/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl05H+ 15.65 l 7.33l l176lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00039l5EOULl05H+ 16.19 l 9.48l l183lDNTlP lj l } l lC4/96l l C lTEC-TEHlTEC-TEHl l00039l5800Ll09H- 0,03 l33.53l l181lDNTjP 1l l l102l 78l04/96l l C lTEC-TEHlTEC-TEHl l 00038 l 580%l09H+ 'O.06 l26.32l l181lDNTlP 1[ l 1132l 78104/96l l C lTEC-TEHITEC-TEHI l0o093l580ULl10H+ 20.40 lt6.97l l173lDNTIP 1l l l 91l 79l04/96l l C lTEC-TEHlTEC-TEHj l 0004 0 l 580ULl 09H+ 0.00 l38.45l l179lDNTlP 1l l l 93l 79l04/96l l C lTEC-TEHlTEC TEHl IC0040l500ULjo9H-0.06 l55.30l l176lDNTlP 1l l l 95l 79l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H+ 0.00 l70.40l l179lDNTlP 1l l } 97l 79l04/96l l C lTEC-TEHlTEC-TEHl l00038l5800Ll09H-0.12 l93.55l l171lDNTlP 1l l j 99l 79l04/96l l C lTEC-TEHlTEC-TEHl l00039l500ULl09H+ 0.00 l23.27l l182lDNTlP 1l l l201l 79l04/96l l C lTEC-TEHlTEC-TEHl l00038l580ULl09H-0.27 l24.95l l174lDNTlP 1) l } l 92l 80l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H-0.06 l47.55l l178lDNTlP 1l l l 94l 80l04/96l l C lTEC-TEHlTEC-TEHl l00039l560ULl09H-0.21 l58.91l l181lDNTlP 1l l l 96) 80l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H-0.03 l63.18l l179lDNTlP lj l l100l 80l04/96l l C lTEC-TEHlTEC-TEHl l0003)l580ULl09H+ 0.00 l 5.09l l179lDNTlP 1l l l102l 80l04/96l l C lTEC-TEHlTEC-TEHj l0003Bl580ULl09H+ 0.09 l 9.19l l173lDNTlP 1l l l 41l 81l04/96l l C lTEC-TEHlTEC+TEHj l00127l580ULl01C+ 19.64 l 5.15l l179lDNTlP 1l l l 85l 81l04/96l l C lTEC-TEHlTEC-TEHj jo0120l5800Ll05C+ 31.63 l 5.09l l181lDNTlP 1l l l 91l 81l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.06 l25.85l l1F0lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC TEHl l00040l580ULl09H+ 2.19 l11.20l l172lDNTjP lj l l 95l F1l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H+ 0.00 l117.7j ll?7lDNTlP 1l l l 97[ 81l04/96l l C lTEC-TEHlTEC-TEhl l00038l580ULl09H-0.03 l98.93l l171lDNTlP 11 l l 99] 81l'J4/96l l C lTEC-TEHlTEC-TEHl l00039l580ULl09H+ 0.00 l80.98l l181lDNTlP 1l l l101l 81l04/96l l C lTEC-TEHITEC-TEHI l00038l580utl09H-0.15 l24.561 1174lDNTlP 1! l l 92l 82lD4/96l l C lTEC-TEH]TEC-TEHj l 0004 0 l 50 0UL } 09H-0.12 l24.82l l172lDNTlP 1l l-l 94l 82l04/96l l C lTEC-TEHlTEC.TEHl l00039l580ULl09H+ 0.00 184.05l l179lDNTlP ll l l 96l 82l04/96l l C lTEC-TEHlTEC-TEHl l00039l584ULl09H+ 0.00 l157.9l l176{DNTlP 1l l l 98l 82l04/96l l C lTEC-TEHlTEC-TEHl l00038l580ULl09H+ 0.06 jlC1.1l l173lDNTlP 1l l l100l 82l04/96l l C lTEC-TEHjTEC-TEHl l 00039 l 58 0UL j o,9H+ 0.09 l149.2l l176lDNTlP lj l l102ls2l04/96l l C lTEC-TEHlTEC-TEHl l00038l5800Ll09H+ 0.03 l24.41) l176lDNTlP ll l l104l 82l04/96l l C lTEC-TEHlTEC-TEHj l00039j5800Ll09H+ 0.09 l12.82l l182lDNTlP 1l l l108l 82l04/96l l C lTEC-TEHjTEC-TEHl l00039l580ULl09He 0.09 l75.75l l179lDNTlP 1l l l110l 82l04/96l l C lTEC-TEHjTEC-TEHj l00038l580ULlU3H+ 0.03 l11.60l l177lDNTlP 1l l } 37l 83l04/96l l C lTEC-TEHlTEC-TEHl l00127l580ULlVM + 2'.96 l 8.06l l174JDNTlP 1l l l 91l 83l04/96l l C lTEC-TEHlTEC-TEHl l00040l580ULl09H+ 0.06 l31.24] l180lDNTlP 1l l } l 95l 83l04/96l l C lTEC-TEHlTEC-TEHl l00039l580ULj09H+ 0.00 8 l70.80l l180lDNTlP1l l l l 97l 83l04/96l l C lTEC-TEHlTEC-TEHl l00038l580ULl09H+ 0.00 l184.8l l167lDNTlP 1l l I l 99l 83l04/96l l C lTEC-TEHjTEC-TEHl l00039l580ULl09H+ 0.00 l206.8l l180lDNTlP 1l l l l101l 83l04/96l l C lTEC-TEH]TEC-TEHj l00038l580ULl09H. 0.12 l51.72l l173lDNTlP 1l l l105l 83l04/96l l C lTEC-TEHjTEC-TEHl l00038l580ULl09H+ 0.09 l23.00l l178lDNTlP 1l l l127l 83l04/96l l C lTEC-TEHlTEC-TEHl l00093l580VLl06H+ 14.75 l 5.38l l175lDNTjP 1l l l 401 84l04/96l l C lTEC-TEHlTEC-TEHI l00126l580utivM + 1.97 l 9.72l l178lDNTIP 1l l L._ L._l i I __ I 'l l_l I I I L _ L_ l__ l_._ l l ROCKRIDGE TECENOLOGIES T

l CUMULRTIVE REPOR1 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR

11 PAGE: 11 OF 22 0'.7TAGE DATA SET
CURRENT DATE:

06/07/96 SELECTION VARIABLESt Indication Location, Percent TIME: 00:51:36 l l l EXAM l l .l EXAM EXTENT l l l l l [ JROWlLINl DATEl HEAT 8l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l 1OCA"'J ON l VOLTS. MIL ll:EGl % lCH lCHNGl i-. _ l._ l I l --._ I l l_I l l 1 __ l _. L l_ l _ l l 94l 84l04/96l l C lTEC TEHlTEC-TEHl l00130l580ULl09H. 0.00 l27.49! l162lDNTlP 1l l l 961 84104/96] l C lnC-nHITEC-TEHj l00038l5800Ll09H+ 0.00 l62.60] l179lDNTjP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00038 l580ULlVM + 17.79 l 10. 8 91 l176lDNTlP 1l l l100l 84l04/96l l C lTEC-n HlTEC-nHI l00038l580utlosH. 0.06 l85.501 IM3lDNTlP 11 l -l102l 84l04/96l l C lnC-nHITEC-TEHj l0013015800Ll09H+ 0.00 l20.18l l181lDNTlP 1l l l104] 84l04/96l l C lTEC-TEHjTEC-TEHl l00038l58d%l09H- 0.15 l 6.29' l M4lDNTjP 1l l l108l 84l04/96l l C lTEC-TEHlTEC-TEHj l00038l580ULl09H-0.18 l44.43i l175]Dh7lP 1l l

M0l 84l04/96]

lC lTEC-nHlnC-TEHl l 00130 l 5fiOEl 09H-0.0; l41.49' l182lDNTlP 1l l { l 37l 85l04/96l l C lTEC-TEHlTEC-TEHl l 00127 l 580UL l 06 C. 14.16 l 7.46i l170lDh7lP 1l l l l04/96l l C lTEC-TEHlTEC TEHj l00127l580 E l066 13.21 l 7.13' l172lDNTjP 1l l

411 85l04/96l lC lTEC-TEHjTEC-TEHl l00128l580UnlvM. 2.c6 l.1,14' l 77lDh7lP il l

1 91l 85l04/96l l C lTEC.TEHlTEC-TEHj l00087l580ULl09H. 2.26 l 6.72l l169lDNTlP 1l l l ] l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09C-0.67 l 8.74 l

  • 70lDtClP 1l l

l [04/96l l C lTEC-TEHlTEC-TEHl l00087l580Cl09C-0.33 I 7.60 l M 0 lDtCl P 11 l ) l l04/96l l C lTEC-TEHlTEC-TEHl l00087l580Cl08C. 4.76 l 7.27 l

  • 74 lDtCj P 1l l

{ 93l 85l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H-0.27 If2.52 l M6lDNTlP 1l l I 95l 85l04/96l lC lTEC-TEHjTEC-TEHj ~l00087l580ULiO9H-0.03 !!4.19 lM 0lDhilP 1l l 47l 85l04/96l l C lTEC-TEHlTEC-TEHj l 0008 8 l 5 8 0C*. l 09H. 0.12 til.59 lM6lDh7lP 1l l 39l 85l04/96l l C lTEC-TEHlTEC-TEHl l00087l580U.l09H- 0.0: l66.28 lM1lDtClP lj l

  • 01] 85l04/96l l C lTEC-TEHlTEC TEHl l00088l580U'l09H-0.12

!!5.44 lM5lDhilP 1l l 103l 85lC4/96l l C lTEC-TEHlTEC-TEHl l00087l580U*l09H. 0.Cf l17.77' lM6 lDtC;P 1l l 17l 5104/96l l C lTEC-TEHlTEC.TEHj l 00082158 ct L l 09H-0.c3 1:2.67 l M4 l DN--l P 1 l l

9l 85l04/96l l C l REC-TEHITEC-TEHI l 0008 8 l 580CL ! 09H-0.c4 144.37 l1 6lDrCIP 1l l

j .15l 85l04/96l lC l'I'EC-TEH j TEC-TEH I l00087l$80Cl09H-0.1" l 8.964 l1'2lDiClP 1l l 40l 86l04/96l l C lTEC-nHlnC-TEHi l00128l580uLivM. 2.c: l 6.05: llillDhTlP 1l l 44l 86l04/96l lC lTEC-TEHlTEC-TEHl l 00128 l 5 8 0UL l 06C-2 3. 0 6 l 9.16 lM9lDtClP 1l l 32] 86104/ n j l C lTEC-TEHlTEC-TEHI 100c87l580=l09H- 0.c4 lf4.93 lM3lDtC]P 1] l 54l 86104/96l l C lnC-nHlnC-TEHI l000a8l580cl09H. 0.c3 l 30.1-lM3lDtCIP 11 l 96l 86104/961 l C lTEC-TEHITEC-TEHl 10o087l580cl09H-0.03 l 8.67; lU2lDNTIP 1l l n j 86104/96l l C lTEC-TEHlrs:C-TEHj l00088l580c!09H-0,0-I a.09 l1 5]DNTlP 1l l

?Ol 86l04/96l l C lTEC-TEHjTEC-TEHj l00087l580ULl09H-0.0; l37.97-l174 lDtCj P 1l l

102l 86l04/96l l C lTEC-TEHlTEC-TEHj lC0080l580ULl09H-0.0i l17.27, l174lDNTlP 1l j u4l 86l04/.96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.Cf l42.63! l M 3lDNTlP 1] l

M l 86l04/96l l C lTEC-TEHlTEC-TEHl l00088l580Cl09H.

0,0f lf6.82! l U 6lDNTlP 1l l 108l 86l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l$1.261 lU8lDIClP 1l l 110l 86l04/96l l C lTEC-TEHlTEC-TEHl l00088l580VLl09H+ 0.3' l33.821 jL79lDNTlP 1l l .M41 86l04/96l l C lTEC-TEHlTEC-TEHj l00088l580CLl09H. 0.3: l45.92: l176lDtClP 11 l M 6l 86l04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H. 0.05 l *. 6. 2 31 (M 5lDNTlP 1l l 67l 87l04/96l l C lTEC-TEHlTEC-TEHj l00128l580UL{VM. 23.22 l 5.89! l1*'1lDNTlP 1l l 69] 87l04/96l l C lTEC-TEHjTEC-TEHl l00129l500ULlDH + 7.77 l 7.91! jl76lDNTlP 1l l 91l 87l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09P-0.03 [f6.38! l172lCNTlP 1l l 93l 87104/96l l C lTEC-TEHlTEC-TEHl l00088l580%l09H4 0.03 l122.7! l175lDNTlP 1l l, 95l 87l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H. 0.03 l128.91 l170lDNTlP 1l l 97l 87l04/96l l C lTEC-TEN]TEC-TEHj l00088l580ULl09H. 0.12 l *.18. 0 ! l175lDNTlP 1l l 99l 87)04/961 l C lTEC-TEHjTEC-TEHj l00087l580ULl09H. 0.12 l118.0t l M2lDtClP 1l l _I _ l I l_.I l l_l l 1 -_-l_I_ L_ L _I ROCKRIDGE TECENOLOGIES

.m m i _ CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 12 OF 22 OtTTAGE CATA SET 1 CURRENT DATE: 06/07/96 .SELECTICN VARIABLES: Indication Location, Percent TIME: 00:51:36 l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLIN DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl 8 lCH lCHNGl l _._ l _J l [._ l l L._ I l l l l l__l_ i_.l l l103l 87l04/96l lC lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l57.38l l173lDNTlP1l l l105l 87l04/96) l C lTEC-TEHlTEC-TEHI l00088l580UL]09H+ 0.12 l108.5l l176lDNTlP 1l l l107l 87!04/96l l C lTEC-TEHlTEC-TEHl l00087l500ULl09H- 0.18 l13.19l l171lDNTlP 1l l l109l 87l04/96l l C lTEC-TEHlTEC-TEHl l s0'088 l5800Ll 0pH+ 0.03 l21.32l l177lDNTlP 1l l l 40l 88l04/96l l C lTEC-TEHlTEC-TEHl l00128l580ULlVM + 1.85 l 9.36l l177lDNTlP 1l l l 92l 88l04/96l l C lTEC-TEHlTEC-TEHl l00087l58hULl09H+ 0.03 l37.63l l173lDNTlP 1l l l 94l 86:04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULjo,9H-0.03 l128.0l l170lDNTlP1l l l 96l 86l04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULj09H- 0.03 l129.8l l174lDNTlP 1l l l 98l 88:04/96l lC lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.06 l53.58l l175lDNTlP 1l l 1 [100] 86.04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.12 l50.24l l178lDNTlP 1l l l114l 88!04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H-0.03 l59.79l l175lDNTlP1l l l118l 85104/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l 9.61] l181lDNTlP 1l l l 91l 87 04/96l l C lTEC-TEHlTEC-TEHi l00087l580ULl09H+ 0.00 l46.40l l179lDNTlP 1] l } l 04/96l l C lTEC-TEHlTEC-TEH! l00087l580ULl09C+ 1.96 l14.62l l168lDNTlP 1l l l 93l Si 04/96l l C lTEC-TEHlTEC-TEHj jo0088l580ULl09H-0.03 l95,65l l174lDKrlP 1l l l 95l Gir 04/96l lC lTEC-TEHlTEC-TEHI l00087l580ULl09H+ 0.00 l84.09l l171lDNTlP 1l l l 97l Gi 04/96l l C lTEC-TEHlTEC-TEH! l00088l580ULl09H+ 0.00 l91.57l l175lDNTlP 1l l l101l !) 04/96l l C lTEC-TEHlTEC-TEHj l0C098l580ULl09H+ 0.18 l18.68l l176lDNTlP 1l l j103l is 04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.15 l 6.10l l176lDNTlP 1l l j105l 65 04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0,00 l10.39l l182lDNTlP 1l l l109l si 04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.27 l11,85l l175lDNTlP 1l l 'u3l e3 04/961 l C lTEC-nHITEC-TEHI l00088l580uL109H-0.21 l14.111 l174lDNTlP li l { .119l si 04/96l lC lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.03 l24.64l l173lDNTlP 1l l l1271 ,1 04/96l lC lTEC-TEHlTEC-TEHI l00087l580ULl100- 2.05 l 5.07l l177lDNTlP 1l l l l 04/961 l C lTEC TEHlTEC-TEHl l00 0 87 j 580VLl 09C+ 19.78 l 5.79l l175lDNTlP1l l 1 921 4 04/961 l C lTEC-TEHlTEC TEHj l00087l5800Ll09H-0.03 l39.98l l171lDNTlP 1l l 94l 04/96l lC lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.12 l30.80l l175lDNTlP 1l l + 96l 9: 04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l63.73l l178lDNTlP 1l l

sBI 9
04/961 lC lTEC-TeHjTEC-TEHl l0c008l580ULl09H+

0.00 l12.13l l182lDNTIP 1l l ) (IrJ0l 9: 04/96l l C lTEC-TEHlTEC-TEH] l 00100 l 58 0UL l 09 H + 0,00 l29.00l l181lDNTlP 1l l 1 l l 04/96l l C lTEC-TEHlTEC-TSHj l00087l5800Ll09H+ 0.03 l27.74l l173lDNTlP 1l l l102] 3: 04/96l l C lTEC-TEHlTEC-TEH) l00088l580ULl09H+ 0.21 l19.19] l173lDNTlP 1l l l110] 90'04/96l lC lTEC-TEHlTEC-TEHj l000881580ULl09H+ 0.15 l18.23l l177lDNTlP 1l l 1114l S: 04/96l l C lTEC-TEHlTEC-TEHj l00088l5800Ll09He 0.18 l17.03l l175lDNTIP 1l l l 91l 9*'04/96l l C lTEC-TEHjTEC-TEHl l00087l500ULl09H+ 0.00 l42.09l l178lDNTlP 1l l l 93l 91 04/96l l C lTEC-TEHlTEC-TEHj lD0088l580ULl09H+ 0.27 l49.99l l175lDNTlP 1l l l 95l 91 04/96l l C lTEC-TEHlTEC-TEHj l 00087 l 580ULl 0!rH-0.03 l21.36l l173lDNTlP 1l l ! 97l 9'. 04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.21 j48.31l l174lDNTlP 1l l l 99l 9' 04/96l l C lTEC-TEHjTEC-TEHj l00387l580ULl09H+ 0.09 l42,50l l175lDNTlP 1l l l103l 91'04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.00 l10.82l l178lDNTlP 1l l l109) 91 04/96l l C lTEC-TEHlTEC-TEPl l00088l580ULl09H+ 0.12 l20.97l l176lDNTlP lj l l 92l 92 04/961 lC lTEC-TEHlTEC-TEH! l00087l580ULl09H+ 0.06 l108.2l l168lDNTlP 1] l l 94l 92 04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 [55.49) l175lDNTlP 1l l l 96l 92,04/96l lC lTEC-TEHlTEC-TEHj l00087l580ULl09H-0.09 l60.05l l172lDNTlP 1l l l 98l 92 04/96l l C lTEC-TEHlTEC-TEHj l0000hl580ULl09H+ 0.15 l31.81l l375lDNT]P 1l l l_I_ l l_I I l.__ I 1 I I l_I_I_I_I_I ROCKRIDGE TECHNOLOGIES

CUMUIATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERAU r

11 PAGE: 13 OP 22 O*I A H DATA SE",

CURR f'NT DATE: 06/07/96 SELE"* ION Vt A MLES: Indic ation Location, Percent TIME: 00:51:36 I lEm I I EXAM EXTENT l l j l l l PN MNl dan EEAT81 LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L _l l_l l L l_.l l 1 l_ L._-. l_ l_ i_ l {10: 92l04/96 l C lTEC-TEHjEC-TEHl l00087l580ULl09H+ 0.09 l42.25l l174lDNTjP 1l l l1c6 92l04/96 l C InC-TEHITEC-TEHI l00088l580ULl09H+ 0.15 l49.15l l176lDNTlP 1l l i l11 92l04/96 l C lTEC-TEHlTEC-TEHj l00088l580ULjo9H+ 0.21 l24.37l l176lDNTlP1l l l 9' 93l04/96 l C lTEC-TEHlTEC-TEHl l 00'087 l 58 0ULl 0,9H + 0.00 l31.56l l174lDNTlP 1l l l 93 93l04/96 l C lTEC-TEHlTEC-TEHl l00088l5800Ll09H- 0.03 l46.12l l175lDNTlP 1l \\ l 93 93l04/96 l C lTEC-TEHlTEC-TEHl l00087l58hULl09H+ 0.03 l56.33l l173lDNTlP 1l l I 57 93l04/96 I C ITEC-TEHlTEC-TEHl l 0008 8 l 58 0ULl 0,9H+ 0.09 l35.64l l176lDNTlP 1l l l 93 93l04/96 l C lTEC-TEHjTEC-TEHj l00087l580ULl09H. 0.15 l14,72l l171lDNTlP 1l l l1C3 93l04/96 l C lTEC-TEHlTEC-TEHl jo0087l580ULl09H- 0.29 l 8.03l l178lDNTlP 1l l l1C" 93104/96 l C lTEC-TEHlTEC-TEHl l00087l5800Ll09H+ 0.09 l30.82l l174lDNTlP 1l l llti 93l04/96 l C jTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.21 l33.05l l175lDNTlP 1l l l 94 H l04/96 l C lTEC-TEHlTEC-TEHl l0008fj580ULl09H. 0.15 l16.05l l176lDNTlP 1l l l: 94l04/96 l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.03 l58.10] l173lDNTlP 1l l l1C 94l04/96 l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.12 l15.06l l176lDNTlP 1l l l1:, nl04/n lC InC-TEH ITEC-nHI l00087l580uol09H+ 0.00 l43.91l l175lDNTIP1l l llM 94l04/96 l C lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.09 l73.51l l175lDNTlP 1l l l1;! 94l04/n l C lTEC-TEHlTEC-TEHl lu0087l580ULl09H+ 0.03 l39.02l l174lDNTlP 1l l 9 l11 Hl04/96 lC lTEC-TEHlTEC-TEHl l00088l560ULl09H-0.12 l18.19l l176lDNTlP ll l l } l04/n lC lTEC-TEHlTEC-TEHl l00088l580VLl01C+ 33.62 l 9.70l l173lDNT!P 1l l j l1. 94104/96 l C lTEC-TEHlTEC-TEHj l00088l580ULl10H-0.06 l65.85j l175lDNTlP 1l l l M 95l04/n j C lTEC-TEHlTEC-TEHl 100087l5800Ll09H-0.03 l27.18l l172lDNTlP 1l l l 55 95l04/96 lC lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.03 l97.89l l175lDNTlP 1l l l 3! J5l04/96 l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.06 l39.79l l173]DNTlP 1l l l 9" iSl04/96 l C lTEC-TEHlTEC-TEHj l00068l5BOULl09H+ 0.00 l101.4l l173lDNTlP 1l l I lH 95104/96 l C lTEC-TEHlTEC-TEHl l00087l58tULl09H+ 0.00 l62.42l l178lDNTjP 11 l l l04/96 lC lTEC-TEHlTEC-TEHl l00087l580ULl09C- 0.21 l 5.86l l179lDNTlP 1l l l1". Ml04/96 jC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.15 l34.98l l175lDNTlP 1l l l1 - 3sl04/n l C lTEC-nHITEC-nHi l00087l5scULl09H+ 0.00 l62.04l l172lDNTIF 1l l l1;* 15l04/96 l c lTEC-TEHlTEC-TEHj l00087l580ULl09H-0.03 l31.30l l171lDNTlP 1l l lu asl04/n l C lTECaEHlTEC-nHl l00088lSe0ULl09H+ 0.09 l14.17l l173lDNTIP 11 l 111' P5l04/96 l C lTEC-TEHlTEC-TEHj l00088l580ULl10H+ 0.00 l84.17l l173lDNTlP 1l l l 1 :. - 95l04/u lC lTEC-nH ITEC-nHl l00087l580uLl10H+ 0.00 l 9.481 l175lDNTlP 1] l ln nl04/n l C lTEC-TEHlTEC-TEHI l00087l580ULl09H. 0.06 l24.53] l173]DNTIP 1] l iH Hl04/n l C juc-nHjTEC-TEHI l00088l580ucl09H+ 0.00 155.49l 1182lDicrlP ll l lH 96l04/96 l C lTEC-TEHlTEC TEHj l00087l580ULl09H-0.09 l68.42l l170lDNTlP 1l l l1C* 96104/96 l C lTEC-TEHl7 _C-TEHl l00087l580ULl09H-0.06 l 5.33l l173lDNTlP lj l jlM nl04/96 l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l47.54l l174]DNTlP ll l l11: 96l04/96 l C JTEC-TEHjTEC-TEHl l00088j580ULl09H+ 0.06 l24.14l l176lDNTlP lj l = l11i 96l04/n l C lTEC-TEHlTEC-TEHl l00088l580ULl10H+ 0.00 l19.20] l181lDNTlP 11 l l125 96l04/96 l C lTEC-TEHlTEC-TEHl l00089l580ULl09H+ 0.23 l 5.09l l180lDNTlP 1l l lc 97l04/96 l e l REC-nHlTEC-TEHI l00072l580utl04H+ 6.29 l 5.85l l178]DNTIP 1] l l 91 91l04/96 l C lTEC-TEHjTEC-TEHl l00087l580ULl09H+ 0.03 l31.82l l176lDNTlP 1l l l l04/96 l C lTEC-TEHjTEC-TEHj l00087l580VLl09C+ 2.12 l12.35] l169lDNTlP 1l l l 93 97l04/96 l C lTEC-TEHlTEC-TEHl l00088l580ULl09H-0.06 l94.631 l174lDNTlP 1l l lH 37l04/n l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0 03 l82.41] l174]DNTlP 1l l L.-.- _ _ I _.-- l _ I l l_l l l l l_i_l_i_l_I ROCERIDGE TECHNOLOGIES

-~ !l' CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 l STEAM CENEAATOR 11 PAGE: 14 OF 22 OUTAGE CATA SET CURRENT DATE: 06/07/96 SELECTICN VARIABLES; Indication Location, Percent TIMEi 00:51:36 l l l EKAMl l-l EXAM EXTENT l l 'l l l l l ROW lLIN. DATElHEAMjLEGl PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l _ L._.. I l_l l l_ I l l l l _ ] __ L L _ l __._ l l 97l 97.04/96l j C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.06 l142.1l l172lDNTlP 1l l l 99l 97'04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.00 l66.01] l176lDNTlP 1l l l105] 97 04/96l l C lTEC-TEHjTEC-TEHj l00088l580UL]02C+ 17.85 l 5.58l l171lDNTlP 1l l l l 04/96l l C {TEC-TEHlTEC-TEHj l00088l580ULl02C+ 6.41 l 5.18 l l171lDNTlP 1l l i l107l 97,04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULjo9H- 0.03 l 5.67l l174lDNTlP 1l l l109] 97,04/96l l C lTEC-TEHjTEC-TEHl l00088l58bULl09H-0.06 l63.58] l174lDNTlP 1l l l 92l 98'04/96l l C lTEC-TEHlTEC-TEHl {00078l580ULl09H- 0.09 l30.61l l176lDNTlP 1l l l l 04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.03 l32.98l l174lDNTjP 1l l l 94l 94 04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl09H+ 0.21 l37.56] l175lDNTlP 1l l l 96l 96 04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09R-0.12 l108.3j l169lDNTlP 1l j l 98l 96 04/96l l C lTEC-TEHjTEC-TEHl l00088l580ULl09H+ 0.00 l78.68) l181lDNTl P *1l l l100l 98 04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09H+ 0.00 l11.52l l173lDNTlP ll l l102l 96 04/96l l C lTEC-TEHlTEC-TEHl. l00088l580ULl09H+ 0.03 l27.81l l176lDNTlP 1l l l1101 95 04/96l l C'lTEC-TEHlTEC-TEHl l00088l5800Ll09H+ 0.15 l21.27l l175lDNTlP lj. l -l 69l 99 04/96l ) C lTEC-TEHlTEC-TEHl l00071l500ULlVM + 24.86 l 6.39l l1BDlDNTlP 1l l l 91l 99 04/96l l C lTEC-TEHjTEC-TEHl l00087l580ULl09H-0.03 l41.80l l176lDNTlP lj l l l 04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 1.94 l 7.86l l168lDNTlP 1] .] l 93l 9F 04/96l lC lTEC-TEHlTEC-TEHl l00088l580ULl09H+ 0.00 l62.25l l181lDNTlP 1l 1 l 95l 99 04/96! l C lTEC-TEHlTEC-TEHl l00087l580ULj09H+ 0.06 l22.28l l173lDNTlP 1l l l 97l 99 04/96l

  • C lTEC-TEHlTEC-TEHl l00088l580ULl09H+

0.00 l74.53l l181lDNTlP 1l l l 99l 99 04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H-0.12 l98.71l l173lDNTlP 1l l l101l 99 04/96l l C lTEC-TEHlTEC-TEHl l00088]580ULl00H+ 0.03 l34.41l l176lDNT]P 1l l l105l 99 04/96l jC lTEC-TEHlTEC-TEHl l00088l580ULj09He 0.00 l29.30l l176lDNTlP 1l l l107l 99 04/96l l C lTEC TEHlTEC-TEHl l00087l580ULl09H+ 0.06 jk6.54l l173lDNTlP 1l l 1117l 99 04/96l l C lTEC-TEHlTEC-TEHl l00088l5POULl10H+ 0.00 l25.61l l1P7lDNTjP 1l l l119l 95 04/96l ) C lTEC-TEHlTEC-TEHl l00087l580ULl10H+ D.12 l 6.0Al l173lDNTlP 1l l l121l 95 04/96l l C lTEC-TEHlTEC TEHj l00088l580ULl10H+ 0.00 l 5.97l l180lDNTlP 1l l l 50l10: '04/96l ! C jTEC-TEHlTEC-TE3l l00071l580ULlVM - 2.00 l 5.35l l179lDNTlP 1l l l 92l1M 04/96l l C lTEC TEHlTEC-TEHl l00087l580ULl09H. 0.06 l17.09l l173lDNTlP 1l l 94l100 04/96l l C lTEC-TEHlTEC-TEHj lU0088l5800Ll09H+ 0.00 l14.88l 1182lDNTlP 1l l 96l100 04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09H+ 0.06 155.73l l174lDNTjP lj l l100l10" 04/96l lC lTEC-TEHjTEC-TEHj l00087l580ULl09H+ 0.00 l76.79l l180lDNTlP 1] l l102l100 04/96l l C lTEC TEHlTEC-TEH] l000881580ULl09H+ 0.00 l82.99l l181lDNTlP 1] i l104l100 04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl09H+ 0.00 l17.62l l176lDNTlP 1l l l108l10: 04/96l lC lTEC-TEHlTEC-TEHj l00081l580VLl09H+ 0.00 l37.50) l181lDNTlP lj l l118l100 04/96) l C lTEC-TEHlTEC TEHj l000881580ULl10H+ 0.00 l21.97l l181lDNTlP lj l l 37l101 04/96l lC lTEC-TEHlTEC-TEHl l00069l580VLl06H+ 16.76 l 1.98l l180lDNTlP lj l l l 04/96l l C lTEC-TEHlTEC-TEHl l00069l580VLl07H-1.20 l30.14l l178lDNTlP 1l l l l 04/96l l C lTEC-TEHlTEC-TEHl l00069l580UL]DH + 13.96 l39.98l l177lDNTlP 1l l l l 04/96l l C lTEC-TEHlTEC-TEHj l00069l580ULlVM - 0.73 l24.85l l177lDNTjP lj l l l 04/96l l C lTEC-TEHlTEC-TEHl l000691580ULl06C+ 22.90 l 7.47l l181lDNT)P 1l l l 39l101 04/96l lC lTEC-TEHjTEC-TEHl l00068l580ULl07H+ 0.27 l 8.16l jl?6lDNT[P 1l l j l 04/96l l C lTEC-TEHlTEC-TEHl l00068l580ULl06C+ 19.37 l 5.51l l174lDNTlP 1l l l 691101 04/96i l C lTEC-TEHjTEC-TEHl l00071l580UL}VM + 24.30 l 6.87l l180lDNTlP 1l l j 91l101 04/96l l C lTEC-TEHlTEC TEHl l00081l580ULl09H+ 0.00 l17.06l l175lDNTlP 1l l l _ l._. I L _I I l ___ l l 1 1 l _ L_ l_ _I _ I _ l l ROCKRIDGE TECHNOLOGIES

CtMPATT/a' REPORT 04/96, BGE, CALVERT CLIFFS, UNIT 1 STEAM CENERATOR t 11 PAGEr 15 OF 22 OUTAGE DATA SET CURRENT DATE: 06/07/96 SELECTION VARIABLES: Indication Location, Percent TIME: 00:51:36 l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINj DATElHEATNl LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION lVOL*Sl MIL?DEGl % lCH lCHNGl l_l_l L.- i l l_l l l _ L. _._. l _ ? -_._ l-.__ l _ l _ l l 93l101104/96l l C lTEC-TEHjTEC-TEHj l00088l580ULl09W 0.00 l74.98l 2176lDNTlP 1l l l 95l101l04/96l l C lTEC-TEHlTEC-TEHI l00087l5s0ULl09n 0.00 '.8.32l

271lDNTlP 1l l

, l 97 p01104/96l l C lTEC-n HITEC-TEHI l00088l580utl0Sa+ 0.00 l53.121 .180lDNTIP 11 l l 99l101l04/96l l C lTEC-TEHITEC TEHI l00b87l580ULj0ps-0.24 1113.11 .171lDNTlP 11 l l101l101l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl09h 0.00 l89.C7l

175lDNTlP 1l l

l203l101l04/96l l C lTEC-TEHjTEC-TEHl l00087l506ULl09E- 0.18 l81.92l '172lDNTlP 1l l l105l201104/nl l C lTEC-nHlTEC-TEHI l00088l580UL109s. 0.00 l34.c41

182lDNTlP 1l l

l107l101l04/96l l C lTEC-TEHlTEC-TEHj l00087l580ULl05L 0.00 l57.63l 178lDNTlP 1l l 7 ' l109l101l04/96l l C lTEC-TEHlTEC-TEHl l00088 j5800Ll06b 15.34 l 6.79l '170lDNTlP 1{ l l117l101l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl05G 15.46 l 9.42l 172lDNTlP 1l l l121l101l04/96l l C lne-TEHlTEC-nHI l000881580ut 06 n 15.10 l 5.a3l 176lDNTlP il l j l l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl0d b 15.66 l 9.63l 176lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl10E+ 0,00 l33.42l. 182lDNTlP 1l l l127]101l04/96l l C lTEC-TEHlTEC-TEHl l00001l580ULl1CL 0.06 l 6.54l 181lDNTlP 1l l l133l101]D4/96l l C lTEC-TEHlTEC-TEHl l00Df2l580ULlDH - 19.25 112.43] 176lDNTlP 1l l j j 92l102104/96l l C lTEC-TEHlTEC-TEHl l00087l580uLl09s 0.00 138. al 179lDNTjP 1l l l 94l102l04/96l l C lTEC-TEHlTEC-TEHj l00088l580ULl0ib 0.06 16 8 M7 l 174lDNTlP *.i l 3 l 96l102l04/96l lC lTEC-TEHlTEC-TEHj l00087l58CULl0fL 0.00 149.30l 178 lDNTl' 11 l j l 98l102l04/96l lC lTEC-TEHlTEC-TEHj l00088j580ULl096 0.00 i93.74l 181lDNTl7 1l l ] .l100l102l04/96l l C lTEC-TEHlTEC-TEHl l00087l580ULl09L 0.06 l71.69l 171lDNTl0 1l l l 1102l102104/96l l C lTEC-TEHlTEC-TEHl l000881580ULl0$b 0.00 1119.2l

  • 74lDNTjP 1l l

l106l102l04/96l l C lTEC-TEHlTEC-TEHj l000871580ULl09s 0.00 146.s7l 174lDNTIP 1l l s [122l102l04/96l l C lTEC-TEHlTEC-TEHl l00088l580ULl1CW 0.00 113M9l 180lDNTIP 1l l ] l 21l103l04/96l l C lTEC-TEHlTEC-TEHl l00069l580ULlW + 0.52 1 5.H l 174lDNTlP 1l {~ l 91l103]C4/96l l C lTEC-TEHlTEC-TEHj l00066l5BOULl09b 0.00 l43.07l 181lDNTlP 1l l l 93l103l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09X-0.12 l73.191 175lDNTjP 1l l ) i 95l103l04/961 l C lTeC-TEHlTEC-nHj l00086l580ULl09.- 0.00

27.Hj 179lDNTlP 1l l

1 97l103l04/96l l C lTEC-TEHlTEC-TEHj l00085l58 CULL %r.- % 54 i61.Eil

  • 75lDNTlP 1l l

l 99l103l04/961 lC lTEC-TEHlTEC-TEHj l 000 8 6 l 5 8 0C-. l 05 h 0.a {12.1al 180lDNTjP li l l101l101104/96l l C l tac-TEHITEC.TEHI l00085l580ULl09s 0.06 !203.91 174lDNTIP 1l l }103l103l04/96l l C lTEC-TEHl7EC-TEHl l00086l580DLl09L 0.00 l32.93l 181lDNTlP 1l l l105l103l04/96l j C lTEC-TEHlTEC-TEHl. l00085l5801.Ll0fL 0.09 159.11) 178lDNTlP1l l 1107l103l04/96l l C lTEC-TEHITsC-TEHl 100086l580utl09s 0.00 134.981 177JDNTIP 11 l l l 104/nl l C inC-TEHjTEC-TEHI l00100l580ULl09s 0.00 l35.s3: 180lDNTlP li l l 92l104l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09b 0.00 l R 26l 180]DNTlI lj l l 94l104104/96l l C lnC-TEHlTEC TEHI 100085l580ULl09x+ 0.06 l110.o1 173lDNTlP 11 l l 96l104l04/96l l C lTEC-TEHjTEC-TEHl l00086l$80ULl09L 0% l81.41l 181lDNTIP 1l l i l 94l104l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULj090 0.03 l59.93l 176lDNTlP 1l l j102l104l04/96l lC lTEC-TEHjTEC-TEHj l00085l5800Ll09b 0.12 l 5.76l 176]DNTlP 1l l l106l104j04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULj09h 0.06 l61.45l 175lDNTlP 1] l l124l104l04/96l l C lTEC-TEHlTEC-TEH1 l00092l580ULl1CL 0.15 l 5.12l 178lDNTlP lj l l 1 91l105l04/.96] l C lTEC-TEHlTEC-TEHj l00086l580ULl09'+ 0.00 l59.12l 181lDNTlP 1l l d l 93l105l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl0th 0.18 174.04l 175lDNTlP 1l l l 95l105l04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09b 0.00 l44.43l '181lDNTlP 1l l l 97l105l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09F+ 0.03 l105.6l 174lDNTlP 1l l L-_L l I l_l l l_l 1 1 1 l _ _ L__l _ l_ -.l P.OCKRIDGE TECENOLOGIES

CUMULATIUE REPCT 04/06, BCE, CALUERT CLIPFS, UNIT 1 STEAM GENERATOR

11 PACE: 16 OF 22 OUTAGE DATA SET CURRENT DATE:

06/07/96 SELECTION VARIABLESt Indication Location, Percent TIME: 00:51 36 l l l EXAM l l l EXAM EXTENT l l l l l l lEOWlLIN] DATEl HEAT 8lLE0l PROGRAM l ACTUALjEXPl CAL l PROBE l LOCATION jVOLTSjMILlDEGl % lCH lCHNGl L _L I I l._ l 1 l_1 1 I I l_L l L_I_I l 99l105l04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULl09H+ 0.00 l 21. 4 9 l l183lDNTlP 1l l l101l105l04/96l l C lTEC-TEHjTEC-TEHl l00085l580ULl09H+ 0.00 l15.63l l178lDNTjP 1l l l111l105l04/96l l C lTEC-TEHjTEC-TEHl l00086l580ULjVC + 1.53 l10.92l l175lDNTlP 1l l l117l105l04/96l l C lTEC-TEHlTEC-TEHj l00b85l580ULl10H-0.03 l17.12l l175lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULjl0C- 0.06 l 8.12l l178lDNTlP 1l l l119l105l04/96l l C lTEC-TEHlTEC-TEHj l00086l58DULl10H+ 0.15 l20.56l l181lDNTlP 1l l l121l105l04/96l l C lTEC-TEHjTEC-TEHl jo0085l580ULl10H+ 0.09 l20.92l l179lDNTlP 1l l l123l105l04/96l l C lTEC-TEHlTEC-TEHl l00091l580ULjl0H+ 0.00 l 7.95] l183lDNTlP 1l l' l 92l106l04/96] l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l40.14l l180lDNTlP 1l l l 94l106l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULjo9M+ 0.09 l97.72l l174lDNTlP 1l l l 96l106l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l35.66l l182]DNTlP1l l j 98l106l04/96l l C lTEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.00 l24.30l l179lDNTlP1l l. l120l106l04/96l lC [TEC TEHlTEC-TEHl l00086l5800Ll10H+ 0.00 l15.65j l183lDNTlP 1l l l l l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09C+ 13.77 l 9.28l l180lDNTlPlj l I l122l106l04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl10H+. 0.09 l35.06l l178lDNTlP 1l l l 91l107!04/96l 1C lTEC-TEHlTEC-TEHl l00086l500ULl09H+ 0.00 l 67.4 8 l l181lDNTlP 1l l l 93l107l04/96l l C lTEC-TEHlTEC-TEHl l000BSl580ULl09H-0.06 l102.0l l174lDNTj P 1l l l 95l107l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l61.62l 1181lDNTlP 1l l l 97l107l04/96l JC lTEC-TEHlTEC TEHj l00085l580ULl09H-0.09 !55.39l l176lDNTjP 1l l l l l04/96l 1 C lTEC TEHlTEC-TEHj l00085l580UL]O8C+ 15.36 l 8.53] l175lDNTjP 1l l l 99l107l04/96l l0 lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l31.35l l181lDNTlP 1l l l103[107l04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+ 0.00 l69.70l l181lDNTlP 1l l l107l107l04/96l l ~ lTEC-TEHlTEC-TEHl l00086l580UL]09H+ 0.00 111.02l l180lDNTlP 1l l l123l107l04/96l l C lTEC-TEHlTEC-TEHj l00091l580ULl10H+ 0.15 117.24l l182lDNTlP 1l l l133l10?l04/96) l lTEC-TEHlTEC-TEHl l00092l580ULjo9H+ 0.21 j 6.12l l179lDNTlP 1l l l 94l106l04/96l l C lTEC-TEHlTEC-TEHl l00085l580VLl09H+ 0.27 l45.78l l175lDNTlP 11 l l 961108l04/96l l r lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 ]104.9l jl79lDNTlP 1l l l 981108l04/96l l C lTFC-TEHlTEC-TEHl l00085l580UL{09H+ 0.03 l60.86l l176lDNTlP 1l l l100l108j04/96l JC lTEC-TEHlTEC-TEHl l00086l580ULj09H+ 0.00 132.891 l182lDNTlP1l l l102l108j04/96l l F l7EC-TEHlTEC-TEHj l00085l580ULl09H+ C.00 141. 4 8 l l175lDNTlP 1l l l104l108104/96l l 0 lTEC-TEHlTEC-TEHj l00086l580ULl09H+ 0.00 l25.96l l181lDNTlP 1l -l l106l108l04/96l lC lTEC-TEHlTEC-TEHl l00085l5800Ll09H-0.06 l25.10l l175lDNTlP 1l l l108l108l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l17.29l l182lDNTlP 1l l l118l108l04/96l l C lTEC-TEHjTEC-TEHl l00085l580ULl10H-0.06 l38.57] l174lDNTlP lj j l 69]109l04/96) l C lTEC-TEHlTEC-TEHl l00068l580ULIVM + 25.14 l 8.19l l172lDNTjP 1l l l 91l109l04/96l l C lTEC-TEHjTEC-TEH) l00086]580ULl09H+ 0.00 l24.90l l182iDNTlP 1l l l 93l109l04/96l j C lTEC-TEHlTEC-TEHj l00085l580ULl09H+ 0.09 l46.75l l175lDNTlP 1l l l 95l109l04/96l lC lTEC-TEHlTEC-TEHj l00086l580VLl09H+ 0.00 l32.87l l182lDNTlP 1l l l 97l109l04/96l l0 lTEC-TEHlTEC-TEHj l00085l580ULjo9H-0.12 186.08l l172lDNTlP 1l l l 99l109l04/96l l C lTEC-TEHlTEC-TEHl l00086l500ULl09H+ 0.00 l30.33l l182lDNTlP 1l l l101l109l04/96; lC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l29.00l l176lDt(TlP lj l l103l109l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l64.38) l181lDNTlP 1l l l119l109104/96l l C lTEC-TEHlTEC-TEHl 'l00086]580ULl10H+ 0.00 l12.07l l181lDNTlP*<l l l121l109l04/96l lC lTEC-TEHlTEC TEHl l00085l580UL}10H+ 0.06 l24.17l l175lDNTlP 1l l l l 92l110l04/96l l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l19.16l l180lDNTlP 1l l l 1._. L._ l l l_1 1 l_l l l l 1._ L _i_._l _ l _ l l ROCKRIDGE TECENOLOGIES I

CUMULATIVE REPORT 04/96, DGE, CALVERT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 17 OF 22 C*** AGE DATA SET CURRENT DATE: 06/07/96 ] SE*.ECTION VARIABLES: Indication Location, Percent TIME: 00:51:36 1 l l l EXAM l l l EXAM EXTENT l l l l l l l l ROW lLINl DA3l HEAT # l LEG l PROGRAM l AC"I'UALlEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl 4 lCH lCHNGl I L l_._I I l___I I l_1 1 I I l_I_I_L L._ t l 54l110l04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l31.41l l176lDNTlP 1l l l 96l110l04/96l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l14.23l jl81]DNTlP 1l { l 18l110j04/96l l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.06 l18.34l l178lDNTlP 1l l j l;;6l110l04/56l lC lTEC-TEHlTEC-TEHj l00d85l580ULl09H+ 0.00 l14.94l l174lDNTlP 1l l ) l120]110}04/96l l C lTEC-TEHlTEC-TEHl l00086l5800Ll09H+ 6.41 l 5.13l l178lDNTlP lj l i l l l04/$6l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 7.28 l 5.07) l178lDNTlP 1l l l l l04/96l l C lTEC-TEH]TEC-TEHj l00086l580ULl09H+ 9.25 l 6.77l l178lDNTlP 1l l l l l04/96l l C liEC-TEHlTEC-TEHj l00086l580ULl09H+ 10.61 l 5.01l l178lDNTlP 1l l l128l110l04/96l lC lTEC-TEHlTEC-TEHl l00091]5800Ll08H+ 19.59 l19.26l l177lDNTlF 1l l l l l l04/56l lC lTEC-TEHlTEC-TEHl l00091l580ULl01C+ 30.48 l25.82l l177lDNTlP 1l l l i9l111l04/56l lC lTEC-TEHlTEC-TEHj l00068l5800LlVM + 24.60 l 6.61l l173lDNTlP 1l l l 11l111l04/96l l C lTEC-TEHlTEC-TEHj l00086l580ULl09H+ 0.00 l42.94l l181lDNTlP 1] l l 12l111j04/96l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H-0.09 l48.58l l176lDNTlP 1l l l 15l111l04/161 lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l31.16j 1181lDNTlP 1l l !; 3l111l04/561 lC lTEC-TEH]TEC-TEHl l00086l580ULl0BH+ 17.97 l 6.56l 1179lDNTlP 1l l l i l l04/16l lC [TEC-TEHlTEC-TEHl l00086l5800Ll09H-0.77 l 6.761 !175lDNTlP 1l l l l04/96l lC lTEC-TEHlTEC-TEHj l00086l580ULl09H-0.68 l 5.50l l79lDNTlP 1l l i j l l04/16l lC l TEC-TEH l TE.C-TEH l l00086l580ULl09H-0.30 l10.1tj 179lDNTlP 1l l I l l04/56i l C lTEC-TEHlTEC-TEHl l00086l580ULl09H-0.18 l10.03l ,176lDNTlP 1l l l l04/561 lC lTEC-TEHlTEC-TEHj l00086l580ULl09C+ 0.96 l 9.67l il79lDNTlP 1l l ..Sl111]C4/56l lC lTEC-TEHlTEC-TEHl l00086l580ULl10C+ 0.99 l 8.E5] !174lDNTlP lj j l l l04/56l lC lTEC-TEHlTEC-TEHl l00086l580ULl09C+ 15.26 l 6.98l ._174lDNTlP 1l l .~. 3 l111 ] O4 / 9 6 ! lC lTEC-TEHlTEC-TEHl l00091j5800Ll10C-1.30 l13.95) 179lDNTlP 1l l i 0l112l04/56! lC lTEC-TEHlTEC-TEHj l00067l580ULl02C+ 10.97 l E>.741

191lDNTlP 1l l

l 36l112]C4/96l lC lTEC-TEHlTEC-TEHj l00069l 5800Ll07H+ 19.66 l 6.07l

180lDNTlP 1l l

l i l l04/56l lC lTEC-TEHlTEC~TEHl l00069l580UL]C7H+ 20.54 l15.95) 1180lDNTlP 1l l l 12l112l04/16l lC l TEC-TEH l TEC-TEH l l000P6l580UL]O9H+ 0.00 l25.13l 1182lDNTlP 1l l Ml112l04/161 lC (TEC-TEHlTEC-TEHl l00085l580ULl09H-0.06 l43.31} .175lDNTlP 1l l t

-51112 } 04/ f 61 lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+

0.00 l22.79l 1179lDNTlP 1l l ! ^ 5 l112 l 04 / 5 6 l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l17.51l 179lDNTlP 1l l };'21112l04/551 }C lTEC-TEH]TEC-TEH] l00085l580UL]09H+ 0.09 l24.15]

176lDNTlP 1l l

11:2l112l04/16l lC lTEC-TEHlTEC-TEHj l00086l580ULl10H+ 0.00 lb4.86l

178lDNTlP ll l

11:2l112l04/76l lC lTEC-TEHlTEC-TEHl l00085l580ULl10H+ 0.00 l18.71l 1176lDNTlP 1l l l l 3 5 l113 l 04 / 9 6 l lC lTEC-TEHlTEC-TEHl l00065l580UL]VM - 1.44 l 7.34] [ 3lDiTTlP 1l l l iPl113l04/96l lC lTEC-TEHlTEC-TEHl l00068l580ULlVM + 24.46 l 6.78l l173lDNTlP ll l l l 11l113l04/56l lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l36.44l 1182lDNTlP 1l l l l 13l113j04/56l lC lTEC-TEHlTEC-TEHj l00085l5800Ll09H-0.09 l94.94] l173lDNTlP ll l l 15l113l04/J61 lC lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l29.47l l178lDNTlP 1l l j 17l113l04/96l l C lTEC-TEHlTEC-TEHl l00085l500ULl09H-0.12 l97.30l l175lDNTlP 1l l ) 19l113l04/86l 8 C lTEC TEHlTEC-TEHl l00086l5800Ll09H+ 0.00 l129.9l 1175lDNTlP 1l l j'~1l113lC4/56l lC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l74.27l il78lDNTlP 1) l j;;3l113l04/16l l C lTEC-TEHlTEC-TEH) l00086j5800Ll09H+ 0.00 l36.36l jl78lDNTlP 1l l l *

  • 5l113l04/96 l lC lTEC-TEHlTEC TEH{

l00085l580UL]D9H+ 0.00 l52.80l 1175lDNTlP 1l l !"17l113l04/96j lC lTEC-TEHlTEC-TEHj l00085l580ULl10H+ 0.00 l50.49l l176lDNTlP lj l l~2;l113l04/56] l C lTEC-TEHlTEC-TEHl l00085l580ULl10H-0.03 l50.25l 1176lDNTlP 1l l ! _ L_ I I l_l l L_ l 1 I l l _ !.__.l__ l _ f _ I i ROCKRIDGE TECHNOLOGIES Y l I

m .__m_ 1 l CUMULATIVE REPORT 04/96, BCE, CALVERT CLIFFS, UNIT 1 STEAM GENERATCR 11 PAGE: 18 OP 22 f OUTAGE DATA SE""

CURRENT DATE:

06/07/96 SELEC* ION VARIABLES Indication Location, Percent TIME: 00:51:36 l l I 1 EXAM' l l EXAM EXTENT l l l l l l lROWI'.1Nl DATE

  • HEAT # l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L_ l _.-_1 L__ I I

l-__. I I I I l _ i_ I _._ L _1 _ _ l l123!113l04/96) l C lTEC-TEHlTEC-TEHl l00091l580ULjl0H-0.06 l33.98l l181lDNTlP 1l l l 12ji14l04/96i j C lTEC-TEHlTEC-TEHj l00065l$800Ll06H+ 8.02 l14.87l l180lDNTlP1l l l l l04/96 j C lTEC-TEHlTEC-TEHl l00065l580ULl06C+ 10.41 l18.04l l180]DNTlP 1l l l 92l114l04/96-l C lTEC-TEHlTEC-TEHl l 00'086158 0utl 09H+0.00 l41.24l l179lDNTlP1l l l l 94l114l04/96 l C lTEC-TEHjTEC-TEHl l00085l5800Ll09H- 0.06 l86.60l l174lDNTlP 1l l l 961114l04/96. l C lTEC-TEHlTEC-TEHl l00086l581ULl09H+ 0.00 l76.69l l175lDNTlP 1l l l 98l n4l04/96 l C lTEC TEHlTEC-TEHj l00085l580ULl09H+ 0.00 l49.32l l176lDFTlP1l l l100!;14l04/96 l C lTEC-TEHlTEC-TEHl l00086l580ULl09H+ 0.00 l34.02l l180lDNTlP 1l l l102in4l04/96 l C lTEC-TEHlTEC-TEHl l00085l580ELl09H-0,09 l37.77l l176lDNTlP 1l l l204;n4l04/96 lC lTEC-nHlTEC-TEH I l00086l585uLl09H+ 0.06 l20.97l 1182lDNTlP 1l l l106<;14l04/96 l C lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.00 l24.22l l177lDNTjP1l l l118 R4l04/96 lC lTEC-TEHlTEC-TEHl l00085l580ULl10H+ 0.00 l 6.4Bj l178lDNTlP ll l l122 n4l04/96 lC lTEC-TEHlTEC-TEHl l00085j580ULl10H+ 0.00 l24.30l l175lDNT[P 1l l l 69 M5l04/96 l C lTEC-TEHjTEC-TEHj l00069l580ULlVM + 24.84 l 6.49l l179lDNTlP 1l l l 93..5l04/96 lC lTEC-TEHlTEC-TEHj l00085l580ULl09H-0.09 l32.25l l176lDNTlP ll l l 97 u5l04/96 C lTEC-TEHITEC-TEHj l00085l5800Ll09H+ 0.03 l35.361 1176lDNTlP 1l l l101 n5l04/96 lC lTEC-TEHlTEC-TEHl l00085l580ULl09H+ 0.36 l15.4 9 l l176lDNTlP 1l l l12-n5104/96 lC l TEC-TEHITEC-nwi l00085l5e0uLl1cH+ 0.00 l 7..:l l179lDNTlP 1l l l 9f R6l04/96 l C lTEC-TEHlTEC TEHl jo0085l580ULlC9H+ 0.00 j29.11l l175lDNTlP lj l l 96 n 6l04/96 lC lTEC-TEHlTEC-TEHl l00086l580ULl09h* 0.00 120.94l l183lDNTlP 1[ [ l106 n6l04/96 lC lTEC TEHlTEC-TEHj l00083l580ULl09H+ 0.15 l 5.14l l183lDNTjP 1l l l12c n 6]04/96 lC lTEC-TEHlTEC-TEH) l00083l580ULl09H+ 0.49 l

5. * $ l l183lDNTlP 1l l

l226 u6l04/96 lC lTEC-TEHlTEC-TEH} l00100l580ULl09H-0.24 [ 6.27l l179lDNTlP 1l l l 69 n?l04/96 l C lTEC-TrHlTEC-TEHl l00069l580ULlVM + 25.01 l 6.69l l179lDNTlPll l l 87 n?l04/96 i C lnC-TEHlTEC-nHI l00076l58euLl06H+ 8.49 l 6.12l l177lDNTlP 1l l l 91 M7]O4/96 l C lTEC-TEHlTEC-TEH) l00083l580ULl09H+ 0.23 l 6.67l jl81lDNTlP lj l l107 n7l04/96 l C iTEC-TEHITEC-TEHi l00083l580utl09H. 0.03 l1s.92l l183!DNTlP 1l l l 12 n8l04/96 lC lTEC-TEHlTEC-TEHI lD0066l580ULl06C+ 7.79 l13.5Bl l182lDNTlP 1l l l102 n8l04/96 jC lTEC-TEHlTEC-TEHl lC0083l580ULl09H+ C.17 l 7.% l l182lDNTlP 1l l l 69 M9l04/96 lC inC-TEH l TEC-TEH I l00069l580ULlVM + 25.10 l 7.06l l179lDNTlP 1l l l 91 n9104/96 lC lnC.nH lTEC-TEH j 100084l580uLivM - 1.02 l13.531 liv 5lDNTlP 1l l l l04/96 lC lTEC-TEHlTEC-TEH] l00084l580ULl09C+ 1.97 l15.63l l174lDNTlP lj l l 97 R9l04/96 l C lTEC-TEHlTEC-TFHj l00084l580ULl09H+ 0.00 l35.96l l178lDNTlP 1] l l 99 Z 9l04/96 lC lTEC-TEHlTEC-TEHl l00084l580ULl09H+ 0.30 l16.65l l178lDNTlP 1l l l 96 12Dl04/96 lC l TEC-TEH l TEC-TEH j l00084l580ULl09H+ 0.21 l28.60l l178lDNTlP 1l l l102,n0l04/96 l C lTEC-TEHlTEC-TEHl l00084l580ULl09H+ 0.00 l17.16l l178lDNTlP 1l l l206:n0l04/96 iC lTEC-TEHlTEC-TEHj l00084l580ULl09H+ 0.00 l38.92) l177lDNTlP 1l l l 69,~.21l04/96 lC lTEC-TEHlTEC-TEHl l00069l580ULlVM + 24.56 l 6.77) l179lDNTlP 1l l l 91 121l04/96 lC lTEC-TEHlTEC-TEH] l00081l580ULl09H+ 0.06 l23.C6l l190lDNTlP 1l l l l04/96 l C lTEC-TEHlTEC-TEHl l00081l580ULj09C+ 0.49 l34.47l l195lDNTlP 1l l l l04/96 lC lTEC-TEHlTEC-TEHl l00081l580ULl09C-0.52 l29.36l l184lDNTlP 1l l 1 l04/96 lC lnC-nHlnC-TEH j l00081l580ULl0BC+ 18.52 l 8.27l l184lDNTlP 1l l l l04/96 lC lTEC-TEH j TEC-TEH j l00081j580ULl08C+ 17.63 l17.18l l196lDNTlP 1l l l 93 n1l04/96 l C lTEC-TEHITEC-TEHl l00081l580ULl09H+ 0.03 l62.48l l185lDNTlP 1l l l 97 121l04/96 l C lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.74 l 7.29l l189lDNTlP 1l l I_ _ I L_ ! 1 L._.1 l 1 1 I l._ l _ l_ i _ I ROCKR1DGE TECHNOLOGIES f 1

. ~. ~ _ - _, _ - _ - ~ - _. I l CUMULATIVE REPORT 04/96, BGE. CM.NERT CLIFFS, UNIT 1 I STEAM CENERATOR 11 pAggi 19 OF 22 OlfTAGE DATA SET i CURRENT DATE: 06/07/96 j SELECTION VARIABLES: Indication Location, Percent TIME: 00:51 06 i I l l l EXAM l l l EXAM EXTENT l l l l l l lkOWlLINl DATEjHEAT#l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION lVCLTSl MIL lDEGl % lCH lCHNGl L _l_I I L_I I l_I I I I l_ L_ L._ L _I_ l l105l121l04/96l l C lTEC-TEHlTEC-TEHj l00084l580ULl09H+ 0.00 l11.54l l175lDNTlP 1{ l l107l121l04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULl09H+ 0.00 l53.37l l177lDNTlP 1l l l209l121l04/96l l C lTEC-TEHjTEC-TEHl l00084l580ULl08H+ 16.14 l 5.85l l358lDNTlP 1) { j l l l04/96l l C lTEC-TEHlTEC-TEHl l00'084 l580ULl0,8H+ 18.52 l 9.37) l175lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00084l580ULl09H-2,74 l6.73] l174lDNTlP1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00084lE8hULl09H- 0.18 l27.54l l178lDNTlP lj l l l l04/96l l C lTEC-TEHlTEC-TEHl l00084l580ULl090+ 1.17 l 7.06l l176lDNTjP 1l l l 30l122l04/96l l C lTEC-TEH]TEC-TEHl l00063l580Cl01H+ 12.91 l 8.55l l177lDNTlP 1l l ( l l l04/96l l C lTEC-TEHlTEC-TEHl l00063l580ULl01H+ 13.46 l13.50l l176lDNTlP 1] l l 38l122j04/96l l C lTEC-TEHlTEC-TEHl l00063l580ULl04C+ 2.63 l22.56l l175lDNTlP 1l l l l 46l122l04/96l lC lTEC-TEHlTEC-TEHl l00069l580ULIVM + 5.15 l 8.99l l179lDNTjP"11 l l 92l122l04/96] j C lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.00 l77.94l l184lDNTlP 1l l l 94l122l04/96l l C lTEC-TEHlTEC-TEHl l00081l580CLl09H+ 0.00 l76.89l ji84]DNTlP 1l l l 96l122l04/96l l C lTEC-TEHlTEC-TEHl l 00081 l 58 0U'. l 0 9H+ 0.06 l11.75l l185lDNTlP 1l l l102l122104/96l l C lTEC-TEHjTEC-TEHl l00081l580Cl09H-0.03 l 5.71} l190lDNTlP 1l l l106l122l04/96l l C lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 0.15 l 5.08l l185lDNTlP 1l l l 15l123l04/96l lC lTEC-TEHlTEC-TEHl l00063l580ULl06H+ 7.74 l17.58l l174jDtfrlP1l l l 69[123l04/96l lC lTEC-TEHlTEC-TEHl l000(9l580ULlVM + 24.80 l 7.11l l181lDNTlP 1l l l 911113 04/96l lC lTEC-TEHlTEC-TEHl l 00061 l 50 0C] 09H e 0.09 l47,86l l185lDNTjP 1l l 4 l l l l04/96l lC lTEC-TEHlTEC-TEHl l00081l580ULl09H+ 2.17 l13.42l l175lDNTlP 1l l l 931123}04/96l lC lTEC-TEHlTEC-TEHl l00061l580ULl09H+ 0.03 l55.82l l184lDNTlP 1l l l l 951123!04/96l lC lTEC-TEHlTEC-TEHl jo0081l580ULl09H+ 0.09 l12.67l l183lDNTlP 1l l l 97l123104/96l l C lTEC-TEHjTEC-TEHl l00081l58CULjo9H+ 0.03 l30.07l l186lDNTlP 1l l l } l04/96l l C lTEC-TEHlTEC-TEHl l0008:1580C]C9He 1.57 l13.72l l186lDNTlP 1l l { l101l1:3l04/96l lC lTEC-TEHlTEC-TEHl l00081l58tUL]O9H+ 0.06 l 6.81l l185lDNTlP 1l l l123l123l04/96] jC lTEC-TEHlTEC-TEHl l00092l580ULl10H-0.34 l 6.05l l172lDNTlP 1l l l 92l124l04/96l lC lTEC-TEHlTEC-TEHl j00061l580rL d9H+ 0.15 l105.0l l183lDNTlP 1l l i l 94l1:4l04/96l lC lTEC-TEHlTEC-TEHj ( 0 0 0 e l j 58 0U*.10 9H+ 0.20 l112.9l l183lDNTlP ll l I l 90l1;4l04/961 lC jTEC-TEHlTEC-TEHl j00061l580C lVH + 1E a0 l 8.17l l181lDNTlP 1l l l 981114iO4/96l lC lTEC-TEHlTEC-TEHl ,00081l580Cl0*L+ 0.09 l34.47l l186lDNTjP 1l l } l 35l125l04/96l lC lTEC-TEHjTEC-TSHl !00062l580ULl06H+ 21.83 l 5.88l jl?6lDNTlP 1l l l l {04/96l lC lTEC-TEHlTEC-TEHl l0DO97l580ULl06H+ 22.45 l 4.83l l175lDNTlP 1l j l 69l125l04/96l l C lTEC-TEHlTEC-TEHl l00069l580ULlVM + 25.11 l 6.90l l179lDNTlP 1l l l 91l125l04/96l lC lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.00 l52.47l l185]DNTlP 1l l l l 93l125l04/96l l C lTEC-TEHlTEC-TEHj l00099l5BOULl09H+ 0.09 l71.37l l185lDNTjP 1l l l l 99l125l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.06 l26.10l l186lDNTlP 1l l l101l125l04/96l l C lTEC-TEHlTEC-TEHl l00099l580ULl09C+ 9.80 j 5.27l l 10lDNTlP 1l l ( {121l125l04/96l lC lTEC-TEHlTEC-TEHl l00081l580ULl06He 15.73 l19.53l l180lDNTIP 1l l l 12l126l04/96l lC [TEC-TEHlTEC-TEHl l00062l580ULl06C+ 9.94 l17.73l l177lDNTlP 1l l l 72l126l04/96) lC lTEC-TEHlTEC-TEHl l00074l580ULl07C+ 18.92 l 9.34l l178lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHj l00068l580ULl07C+ 18.52 l 9.53l l175lDNTjP 1l l l 82l126l04/96l lC lTEC-TEHjTEC-TEHl l00073l580ULl07H+ 14,85 l15.301 l177lDNTlP 1l l l l j04/96l l C.lTEC-TEHjTEC-TEHl jo0073l580ULj08H+ 1.13 l14.26l l177lDNTlP 1l l { l 104/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08H+ 10.34 l23.56l l173lDNTlP 1l l ( l l l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULlDH + 3.37 l15.33l l175lDNTlP 1l [ j l_ L_ I l l ___ I l 1_I I I I l _I_I_L _I_I .r i ROCKR1DGE TECHNOLOGIES 1

~- ..~c j l CUMULATIVE REPORT 04/96, EGE, CALVERT CLIFFS, UNIT 1 l STEAM GENERATOR 2 11 PAGE: 20 OP 22 OUTAGE DATA SET CURRENT DATE: 06/07/96 SELECTION VARIABLES: Indication Location. Percent TIME: 00:51:36 l l l l EXAM l l l EXAM EXTENT l l l l l l l ROW lLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl l _l _I I !_I I l_I I I I l_ _l___ l _ L __I _ 1 l l l04/961 l C lTEC-TEHlTEC-TEHl l00073l580ULlVH + 1.67 l23.26l l178lDNTlP 1l l l l l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULlVH + 4.59 l 8.14l l180lDNTlP 1l l l l l04/96l l C lTEC TEHlTEC TEHj l0007.3l580ULlVH + 5.51 l 7.51l l180]DNTlP 1l l l l l04/96l l C lTEC-TEHjTEC-TEHl l00073l580ULlVM - 1.34 l 9.34l l175]DNTlP 1l l l l ]04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C-0.69 l 6,02l l179lDNTjP 1l l l l l04/96l l C lTEC-TEHjTEC-TEHl l00073l580ULl07C+ 15.26 l 8.98l l181lDNTlP 1] l l 92]I26l04/96l l C lTEC-TEHlTEC TEHj l00099l5800Ll09H+ 0.09 l46.72l l184lDNTlP 1l l l 94l126l04/96] l C lTEC TEHlTEC-TEHl jo0099l580ULj0$H+ 0.06 l19.21l l184lDNTjP 1l l l 96l126l04/96l l C lTEC-TEHlTEC TEHl l00099l580ULl09H+ 0.03 l86.10l l183lDNTlP 1l l l 98l126[04/96l l C lTEC TEHjTEC-TEHl l00099l580ULl094+ 0.12 l26.81l l186lDNTlP 1l l l 69l127l04/96l l C lTEC-TEHlTEC-TEHl l00069l580ULlVM + 25.10 l 6.69l l179lDNTlP 1l l j 91l127l04/96l , C lTEC-TEHlTEC-TEHl l00079l5800Ljo9H+ 0.12 l55.63l l185lDNTlP 1l l l l 104/96l C jTEC-TEHlTEC-TEHl l00079l580ULl09H+ 2.16 l22.31] l176lDNTlP 1l l l 93l127l04/96l C lTEC-TEHlTEC-TSHl l00080l580ULl09H+ 0.09 l72.76l l177lDNTlP lj l l l l04/96l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.09 l78.25l l185lDNTlP 1l l l 95l127 04/96l C lTEC-TEHjTEC-TEHj l00079l580ULl09H+ 0.00 l25.94l l184lDNTlP 1l l l 97i127!04/96l C lTEC-TEHlTEC-TEHl l00099l580ULl09H+ 0.00 l56.73l l186]DNTlP 1l l l l iO4/96] C lTEC-TEHlTEC-01Hl l00080l580ULl09H+ 0.06 l50,05] l178lDNTlP 1l l l 144128 04/96l C lTEC-TEH}TEC-TEHl l00057l580ULl06C+ 8.73 l16.46l l181lDNTlP 1l l l 92l126!04/96l C lTEC-TEHlTEC-TEHj l00074l580ULl09H+ 0.00 l51.59l jl80lDNTlP 1l l l 9t'll28 ; 04/96l C lTEC-TEHlTEC-TEHj l00073l5800Ll09H+ 0.03 l 8.47l l180lDNTjP 1l l l110 l12 E I O 4 /96 l C lTEC-TEHjTEC-TEHl l00073l580ULlVC + 2.27 l 6.53l l172lDNTlP 1l l l107 l12 9 ; 04 /96 l C lTEC-TEHlTEC-TEHl l 00074 l580ULl 09H+ 1.71 l13.20l l178lDNTlP 1l l l 3S j13':104/96l C lTEC-TEHlTEC-TEHl l00061l580ULl02H+ 32.40 l12.27l l176lDNTjP 1l l l 69l131:04/96l C lTEC-TEHlTEC-TEHj l00072l580ULlVM + 24.38 l 7.40l l178lDNTlP 1l l l 931131104/96l C lTEC-TEHlTEC-TEHl l00073l580ULl09H+ 0.15 l19.00l jl79lDNTlP 1l l } 92l132;04/96l C lTEC-TEHlTEC-TEHl l 00074 l58 0ULl 09H-0.26 l 7.4 7l l178lDNTlP 1l l [ (9;13 3;04/96l C lTEC-TEHlTEC-TEHl l00072l580ULlVM + 23.54 l 8.35l l178lDNTlP 1l l l 951133!04/96l C lTEC-TEHlTEC-TEHl l00074l580Pl09H+ 0.29 l 5.56l l176lDNTlP 1l l l 60!134l04/96l C jTEC TEHlTEC-TEHj l00072l580ULl08H+ 15.21 jl5.15l l180lDNTlP 1l l l 96l134jo4/96] C lTEC-TEHjTEC-TEHl l00073l580ULl09H+ 0.30 l 5.51l l177lDNTlP 1l l l 41l135l04/96l C lTEC-TEHlTEC-TEHl l00058l580ULjVM - 1.76 l 5.92l l177lDNTlP 1l l l 69l135l04/96l C lTEC-TEHlTEC-TEHl l00073l580ULlVM + 24.17 l 6.45l l176lDNTlP 1l l l 97l135l04/96l C lTEC-TEHlTEC-TEHj l00073l580ULl09C+ 0.64 l12.53l l1 DlDNTjP ll l l 36l136104/96l i C lTEC-TEHlTEC-TEHl l00058l500ULlVM + 1.84 l 5.98l l175lDNTlP 1] l l 31l137!04/96l C lTEC-TEHlTEC-TEHl l00058]580ULlVM - 1.68 l 6.86l l176lDNTlP 1l l l 35l137104/96l C lTEC-TEHlTEC-TEHl l00058l580ULlVM - 1.36 l 5.63l l1*/8lDNTlP l j l l 69l137;04/96l C lTEC-TEHlTEC-TEHl l00073l5801/LlVM + 24.06 l 8.36l l174lDNTlP 1l l l 77l137!04/96l C lTEC-TEHlTEC-TEHl l00073l5000Ll08C-1.15 l 6.30l l176lDNTlP 1l l l l l04/96l C lTEC-TEHlTEC-TEHl l00073l580ULl07C+ 16.89 l 6.06l l179lDNTlP 1l l l 97l137!04/96l C lTEC-TEHlTEC-TEHl l00n73l580ULl07H+ 16.92 l 1.02l l175lDNTlP 1l l l l (04/96l C TEC-TEHlTEC-TEHl l00073l580ULl08H+ 0.48 l 7.70l l175lDNTlP 1l l l 1' iO4/961 C,TEC-TEHlTEC-TEHj l00073l580ULlD8H+ 4.19 l 9.48l l175lDNTlP 1l l l l 104/96l C lTEC-TEHlTEC-TEHj l00073l580ULl08H+ 7.72 l 9.18l l176lDNTlP lj l l l l04/96l C lTEC-TEHlTEC-TEHl l00073l580ULl08H+ 10.46 l10.30l 'l175lDNTlP 1l l l I __ I __ l I m) i l_1 l l l L._I _ l___l__.l _ I ROCKRIDGE TECHNOLOGIES

- ~ ~ -- i CUMULATIVE REPORT 04/C6,' EGE, CALVERT CLIFFS, UNIT 1 S".'EAM GENERATOR s 11 PAGE: 21 OF 22 2*JIAGE DATA SET

CURRENT DATE:

06/07/96 EELECTION VARIABLES: Indication Location, Percent TIME: 00:51:36 l l EXAM l l l EXAM EXTENT l l l l l l ECWlLINl DATEl HEAT #l LEG l PROGRAM l ACTUAL lEXPl CAL l PROBE l I4 CATION jVOLTSl MIL lDEGl% lCH lCHNGl .__. l _ l l l _I I l_I I I I l_ L_l _L_ l_ _ l l l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08H+ 13.37 l 7.96l l175lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULl08H+ 19.93 l 7.66l l175lDIClP 1l l l l l04/96) l C lTEC-TEHlTEC-TEHl l00073l580VLl09H-1.97 l 9.16l l175lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00673l580ULl0,9H-0.47 l12.37l l176lDNTlP 1l l l l04/96l' l C lTEC-TEHlTEC-TEHl l00073l580ULl09H+ 0.80 l23.86l l176lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHj l00073l580ULl08C+ 17.90 l 9.06l l173lDNTlP 1] l l j04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl06C+ 16.42 l 6.21l l174lDNTjP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00073l580ULl08C+ 12.53 l 6.06l l174lDNTlP 1] l l l04/96l lC lTEC-TEHlTEC-TEHl l00073l5800Ll08C+ 11.02 l10.55l l175lDNTlP 1l l l l04/96l j C lTEC-TEHlTEC-TEHl l00073l580ULl08C+ 8.89 l5.79l l176lDNTlP 1l l l 46l138l04/96l l C lTEC-TEHlTEC TEHl l00058l580ULl05H+ 30.55 l 6.57l l180lDNTlP 1l l l l04/96l lC lTEC-TEHjTEC-TEHl l00058l580ULl06H-2.32 l 6.53l l180lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULl06H+ 0.21 l10;94l l180lDNT[P 1l l l l04/96) lC lTEC-TEHlTEC-TEHl l00058l580ULl06C+ 4.56 l 9.20l l181lDNTlP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00058l580ULl06C+.2.66 l 7.53l l181lDNTlP 1l l l l04/96l l C jTEC-TEHlTEC-TEHj l00058l580ULl06C+ 1.18 l 9,58] l182lDNTlP 1l l i 52l138l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULj09H+ 0.00 l 5.44l l179lDNTjP 1l l isl138l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULl09H+ 0.62 l 6.49) l185lDClP 1l l 3;1139l04/96] l C lTEC-TEHlTEC-TEHl l00058l580ULlVM - 1.82 l 9.84l l174lDElP 1l l 17!139l04/96l lC lTEC-TEHlTEC-TEH] l00059l5800LlVM - 1.57 l11.70l jl?6lDNTlP 1l l 1 l04/96l l C lTEC-TEH}TEC-TEHj l00059l580ULjVM + 1.86 l 9.14l l180lD!ClP 11 l 49l119l04/96l lC lTEC-TEHlTEC-TEHl l00073l580ULlVM+24.44 l 7.64] {174lDNT!P 1l l 35j141l04/96l lC lTEC-TEHjTEC-TEHj l00058l580ULlVM - 1.96 l 6.40l l 1lDZjP ll l 59l141l04/96) i C lTEC-TEHlTEC-TEHl l00073l580ULlVM + 24.3G l 6.45l l172lCnjP 1l l 391142l04/96] l C lTEC-TEHjTEC TEHj l00058l588ULl04C+ 2.74 l 8.52l l178lDrlP ll l f4l142l04/96l l C lTEC-TEHlTEC-TEHl l00059l580ULlDH + 24.63 l 8.84l l175lDr lP lj l { Ol142l04/96l l C lTEC-TEHlTEC-TEHl l00074l580ULlVM - 1.73 l11.10l l180lDElP 1l l l

l143l04/96l lC lTEC-TEHlTEC-TEHj l00058l580ULlVM -

1.60 l 5.22l l177 l D!C j P 1 l l f71143l04/96l lC lTEC-TEHlTcC-TEHj l00074l5800Ll07C+ 2.10 l 7.38l l177lDrlP 1l l 59!143l04/96l l C lTEC-TEHjTEC-TEHj l00074l580ULlVM + 22.47 l 7.56l l179lt ClP 11 l i Ml145l04/96l lC lTEC-TEHjTEC-TEHj l00059l580ULlVM - 1,72 l 8.01l l176lDIClP 11 l l l04/96l l C lTEC-TEHlTEC-TEHl l00059l580ULlVM + 3.63 l 8.39l l178lDNTlP 1l l 59l145l04/96l l C lTEC-TEHjTEC-TEHl l00073l580ULlVM + 24.32 l 8.69l l173lDNTlP 1l l 34l146l04/96l lC lTEC-TEHlTEC-TEHl l00058l5800LlDH + 8.21 l 6.26l l177lDNTlP 1l l 65l147l04/96l l C lTEC-TEH]TEC-TEHl l00073l580ULl01H+ 22.72 l 8.60l l172lDNTlP 1l l ] 37l151l04/961 l C lTEC-TEH]TEC-TEHl l00059l580ULlVM - 1.56 l13.55l l178lDICIP 1l l l (9l151l04/96l lC lTEC-TEHlTEC-TEHj l00074l580ULlVM + 23.96 l 7.08l l178lDClP 1l l j (9l153l04/961 l C lTEC-TEHlTEC-TEHl l00073l580ULlVM + 24.56 l 7.98] l171lDNTlP 1l l l ( 141154l04/96l lC lTEC-TEHlTEC-TEHl l00054l580ULl06C+ 8.80 l17.57l l179lD!ClP 1l l 42l154l04/96l lC lTEC-TEHjTEC-TEHl l00058l580ULl07C+ 1,69 l21.59l l181lDIClP 1l l l l04/96l l C lTEC-TEHlTEC-TEHl l00058]580ULl07C+ 1.10 (15.28l l183lDNTlP 1l l l l04/96l lC lTEC-TEHlTEC-TEHl l00058l580ULl07C+ 0.60 l22.05l l181\\DNTlP 1l l l l04/961 l C lTEC-TEHlTEC-TEHl l 0005 8 l 580ULl 07C-0.91 l 6.61l l182lDIClP 1l l j l04/96l l C lTEC-TEHlTEC-TEHl l00058l500ULl06C+ 20.24 l 5.45] l179lDNTlP 1l l ( 48l154l04/96l l C lTEC-TEHlTEC-TEHj l00059l580ULlDH - 0.42 l10.91l l177lDNTlP 1l l __ I _ I I L._ l l l_I l l l l_] _1_ L_!_I ROCKRIDGE TECHNOLOGIES l t

m _ ._m CUMULATIVE REPORT 04/93, BGE, CALURRT CLIFFS, UNIT 1 STEAM GENERATOR 11 PAGE: 22 OF 22 OL7 AGE DATA SET

CURRENT DATE:

06/07/96 SE*1CT10N VARIABLES : Indication Location, Percent TIMES 00:51:36 v 4 j l l l EXAM l l l EXAM EXTENT l l l l l l lRONlLINl DATElHEATWl LEG l PROGRAM l ACWALlEXPl CAL l PROBE l LOCATION l VOLTS l MIL lDEGl % lCH lCHNGl L_ L_.i l l_I I l _l l I I l.___ L_. L_ I _ I _ I l 69l155l04/96l l C lTEC-TEHlTEC-TEHl l00073l5800LlVM + 24.73 l 6.42l l176lDNTlP 1l l l 34l156l04/96l l C lTEC-TEHlTEC-TEHl l00056l580ULjVM + 3.76 l28.77l l175lDNTjP1l l l 3Sl156l04/96l l C lTEC-TEHlTEC-TEHl l00056l580ULl02H+ 32.27 l26.78l l178lDNTlP1l l l 13l157l04/96l l C lTEC-TEHlTEC-TEHl l0dO53l580ULlVM+ 0.21 l 7.04l l175lDNTlP1l l l 31l157l04/96l l C lTEC-TEHlTEC-TEHl l00056l5800LlVM - 1.70 l 9.20] l176lDNTlP1] l l 37l157l04/96l l C lTEC-TEHlTEC-TEHj l00057l54fDULlVM + 5.29 l12.12l l176lDNTlP 1l l l 57l157l04/96l l C lTEC-TEHlTEC-TEHl l00057l$800Ll07H+ 2.86 l22.72l l175lDNTlP 1l l l a l l 55l159l04/96l l C lTEC-TEHlTEC-TEHj l00056l580ULjV'M + 1.97 l11.54l l176lDNTlP 1l l l 13l161l04/96l l C lTEC-TEHlTEC-TEHl l00050l580ULl06C+ 8.18 l13.68l l182lDNTlP 1l l l 31l161l04/96l l C lTEC-TEHlTEC-TEHl l00057l580ULlV4 - 1.49 l 8.99l l178lDNTlP 1l l l 31l163l04/96l l C lTEC-TEHlTEC-TEHl l00056l580UL]VM - 1.66 l 6.78l l175lDNTlP-il l l 35l163l04/96l [ C lTEC-TEHjTEC-TEHl l00056l5BOULlVM - 1.97 l 7.31l l180lDNTlP 1l l { l _I___I I l __. I I L._I I I I l_I_ l_I_ l I N.MER OF WBES SELECTED FROM CURRENT OUTAGE: 827 NLM ER OF DATA RECORDS SELECTED FROM CURRENT OUTAGE: 957 i N' 3END ANALYSIS REQUESTED CA*'A SELECTION CRITERIA: Ir.d: cation Location: 01H -1.00 to 01C -1.00 Fer enti DNT RII 3T OPTIONSt Cr.ly examinat ion results matching criteria are included i t ROCKRIDGE TECHNOLOGIES

3 56-Lt 9 L 6 - ?_ hv *e4 19e ,/ s.{of %. C}PV CCNPP UNIT 1 U1R12 PLUGGING LIST HOT COLD TUBE LIST ~ S/G ROW LINE LEG LEG REASON FOR REPA!R COUNT REVISION SG11 1 37 ROLL ROLL LPI @ TSH 0.1 1 01 ~ SG11 2 42 ROLL ROLL LPI @ TSH 0.3 2 01 SG11 3 43 ROLL ROLL LPl @ TSH 0.5 3 01 ~ ~ SG11 4 60 ROLUSTAB ROLL SCI 0.5 @ TSH + 0.04 4 01 SG11 5 43 ROLL ROLL LPI @ TSH 0.6 5 01 SG11 6 6 ROLL ROlt SA! 0.3 @ VM 1.8 6 01 SG11 9 45 ROLL ROLL SAI 0.4 @ VM-1.9 7 01 SG11 9 125 ROLL ROLL SAf 1 @ VM 0.0. __8 01 SG11 9 133 ROLL ROLL SAi' O.3 @ VM-1.2 9 01 SG11 10 26 ROLL ROLL 77 %TW @ VM 0.03 10 01 SG11 10 62 ROLL ROLL SA) ' O.3 @ TSH v 0.23 11 01 SG11 10 120l ROLL ROLL sal 0.4 @ TSH 0.2 12 01 4 SG11 11 59 I ROLL ROLL SAI 0.3 @ TSH + 0.79 13 01 S G11 12 i 4*i ROLL l ROLL SAI 0.2 @ TSH + 0.15 14 l 01 l { SG11 13 I 59 ! ROLL ROLL MAI 0.5 @ TSH + 0.26 15 l 01 { SG11 14 ' 60 l ROLL l ROLL sal 0.5 @ TSH - 0.25 16 l 01 i S G11 t 15 59 i ROLL l ROLL I MAI 0.7 @ TSH + 0.20 l 17 l 01 l SG11 15 I 61 i ROLL STAB l ROLL ' SCI 1 @ TSH + 0.12 18 l 01 { S G11 16 60 i ROLL' STAB ROLL SCI 0.5 @ TSH + 0.03 19 l 01 I ) S G11 17 17 i ROLL ROLL lSVI @ TSH 0.1 20 l 01 i S G11 17 23 i ROLL l ROLL lSAI O.2 @ TSH - 0.15 21 01 SG11 17 57 i ROLL l ROLL mal 0.3 @ TSH.e 0.40 22 01 i SG11 17 59 l ROLL l ROLL MAI O.5 @ TSH + 0.41 23 01 i SG11 < 17 61 l ROLL ROLL SAI 0.4 @ TSH + 0.20 24 01 SG11 18 22 l ROLL ROLL i SAI 0.3 @ TSH + 0.25 25 01 SG11 18 62 I R OLL/STA B ROLL ISCI 0.5 @ TSH

0. 0 26 01 l

i

SG11, 18 64 ROLL ROLL sal 0.3 @ TSH + 0.23 27 01 l

59 I ROLL / STAB SG11 19 ROLL SCl O.9 @ TSH v 0.03 28 01 SG11 19 147I ROLL ROLL SAI 0.3 @ TSH 0.2 29 01 SG11 20 48 ROLUSTAB ROLL SCI 0.3 @ TSH + 0.12 30 01 SG11 20 58 ROLL ROLL sal 0.3 @ TSH + 0.21 31 01 SG11 21 107 ROLUSTAB ROLL SCI 0.5 @ TSH 0.2 32 01 SG11 23 55 ROLL ROLL SAI 0.2 @ TSH + 0.18 33 01 SG11 23 59 ROLL ROLL SAI 0.3 @ TSH + 0.25 34 01 SG11 24 G2 ROLL ROLL sal 0.3 @ TSH + 0.22 35 01 SG11 25 141 ROLL TqLL SAI 0.2 @ TSH 0.2 36 01 i SG11 26 22 ROLL R O *_L sal 0.2 @ TSH + 0.11 37 01 SG11 27 67 ROLUSTAB ROLL SCI 1.6 @ TSH + 0.04 38 01 SG11 28 102 ROLUSTAB ROLL SCI 0.7 @ TSH 0.0 39 01 iG11 30 4 ROLL ROLL LPI @ TSH 0.1 40 01 i 1 i

CCNPP UNIT 1 U1R12 PLUGGING LIST 1 HOT COLD TUBE LIST ~ r S/G ROW LINE LEG LEG REASON FOR REPAlR COUNT REVISION SG11 31 3 ROLL ROLL LPI @ TSH 0.1 41 01 SG11 32 58 ROLL ROLL SAI 0.2 @ TSH + 0.15 42 01 j SG11 35 99 ROLL ROLL sal 0.3 @ 04H 0.9 43 01 I SG11 36 164 ROLL ROLL SV1 - @ TSH 12.6 44 of SG11 38 104 ROLUSTAB ROLL SCI 0.5 @ TSH 0.1 45 01 SG11 39 69 ROLUSTAB ROLD SCI 0.5 @ TSH + 0.03 46 of SG11 41 53 ROLL-ROLL SAI 0.2 @ TSH + 0.46 47 01 SG11 41 81 ROLUSTAB ROLL C i S' l 1 ' @ TSH 0.0 48 01 SG11 ' 44 98 ROLUSTAB ROLL SCIM- 0.2 @ TSH 0.4 49 01 i SG11 45 59 ROLL ROLL sal 0.2 @ TSH + 0.14 50 01 SG11 46 50 ROLL i ROLL SAI 4 ' 0.3 @ TSH + 0.78 51 01 i SG11 '46 '54 ROLL l ROLL SAI 0.2 @ TSH + 0.95 52 01 . SG11 46 56 ROLL ROLL MAI 0.3 @ TSH + 0.92 53 01 SG11 46 66 ROLL ROLL sal 0.5 @ TSH + 0.24 l 54 01 l 1 SG11 47 53 ROLL ROLL sal 0.8-@ TSH + 0.91 l 55 01 l SG11 47 55 ROLL i ROLL mal 0.2 @ TSH + 1.57 l 56 01 i SG11 47 115l ROLL ROLL l SAI 0.2 @ TSH 0.9l 57 01. i l SG11 48 -54 ROLL ROLL lSAI 0.9 @ TSH + 0.72.I 58 01 l I SG11 48 56 ROLL I ROLL lM Al 0.4 @ TSH + 0.36 l 59 01 } [ .iG11 49 55 l - ROLL ROLL l mal 0.4 @ TSH + 0.28 I 60 01 I { SG11 50 54 l ROLL ROLL MAI 0.6 @ TSH + 0.63 l 61 01 l SG11 51 55 l ROLL ROLL i M Al 0.5 @ TSH + 0.38 l 62 01 l SG11 51 115l ROLL i ROLL SAI 0.2 @ TSH 0.6l 63 01 l f SG11 52 74 { ROLUSTAB i ROLL SCI 0.5 @ TSH + 0.34 l 64 01 SG11 52 76 l ROLUSTAB i ROLL l SCI 0.3 @ TSH + 0.04 65 01 SG11 52 112 ROLL ROLL l sal 0.5 @ TSH 0.7 1 66 01 l SG11 52 114-ROLL ROLL lS AI 0.4 @ TSH 0.6 67 01 SG11 52 116 ROLL i ROLL sal

0. '2

@ TSH 0.3 68 01 SG11 53 55 ROLL l ROLL sal 0.2 @ TSH 0.4 69 01 SG11 53 83 ROLUSTAB ROLL SCI 0.4 @ TSH 0.0 70 01 SG11 54 60 ROLL ROLL SAI 0.4 @ TSH + 0.62 7_1 01 SG11 54 74 ROLL ROLL SAI 0.3 @ TSH + 0.69 ?2 01 SG11 54 112 ROLL ROLL mal 0.2 @ TSH 0.5 73 01 SG11 55 51 ROLL ROLL PPI 0.4 @ DH _ 2.F 74 01 SG11 55 59 ROLL ' ROLL mal 0.6 @ TSH + 0.64 _JE 01 [ -{ SG11 56 48 ROLUSTAB ROLL SCI 0.5 @ TSH + 0.14 76 01-SG11 56 60 ROLL ROLL MAI 0.4 @ TSH + 0.94 77 01 SG11 56 110 ROLL ROLL sal 0.29 @ TSH 0.5 78 01 SG11 56 118 ROLUSTAB ROLL SCI 0.47 @ TSH 0.1 79 01 311 57 57 ROLL ROLL MAI 0.5 @ TSH + 0.79 80 01

~ .i ) REV01 CCNPP UNIT 1 U1R12 PLUGGING LIST Pags _J_,0r g l HOT COLD TUBE LIST ~ i S/G ROW LINE LEG ' LEG REASON FOR REPAIR COUNT REVISION SG11 58 34 ROLL ROLL MSI 0.2 @ DH 12.1 81 01 SG11 58 108 ROLL-ROLL SAI 0.25 @ TSH 0.3 82 01 SG11 59 87 ROLL ROLL SAI 0.4 @ TSH 0.1 c3 ( _ Og SG11 60 52 ROLUSTAB ROLL SCI 0.4 @ TSH + 0.07 SG11 60 86 ROLL ROLL - SAI 0.5 @ TSH 1.0 , ty,._ 01 SG11 60 96 ROLL ROlt. MSI 2.1 @ 07H 9.2 h 01 M 01 SG11 60 114 ROLUSTAB ROLL , SCI 0.4 @ TSH 0.1 87 01 SG11 61 13 ROLL ROLL SAI 0.2 @ 07H 24.9 88 01 SG11 62 44 ROLUSTAB ROLL SCI'* 1.1 @ TSH + 0.14 89 01 SG11 63 23 ROLL ROLL MSI 0.5 @ OH 20.0 90 01-SG11 63 61 ROLUSTAB ROLL SCI ' O.7 @ TSH + 0.04 9.1 01 SG11 63 65 ROLUSTAB ROLL SCI 0.8 @ TS H + 0.09 92 01 SG11 64 1 32 ROLL i ROLL sal 0.3 @ TSH + 0.58 l 93 01 ~ SG11 ! 64 1 40 i ROLL l ROLL , S A) 0.2 @ DH 4.5l 94 01 SG11 i 64 i 54 I ROLL' STAB l ROLL SCI 0.2 @ TSH + 0.11 l 95 01 t SG11 l 64 l 94 I ROLL l ROLL PPI 0.5 @ 07H 23.6 l 96 01 i SG111 64 l' 110 i ROLL l ROLL PPI 0.5 @ OH 3.3! 97 01 SG11 i 66 l 42 i ROLL l ROLL PPI 0.2 @ 08H 7.3I 98 01 SG11 1 66 l 44 ROLL ROLL PPl 0.2 @ 08H 1.9i 99 01 I SG11 l 66 l 52 ROLLISTAB ROLL SCI @ TSH 0.11 i 100 01 SG11 l 66 l 136l ROLL < STAB l ROLL SCI 0.2 @ TSH 0.1i 101 01 i SG11 ) 67 1 49 l ROLUSTAB l ROLL SCl 1.4 @ TSH + 0.09 l 102 01 1 SG11 l - 67 l 91 ROLL l ROLL MAI 0.5 @ TSH + 0.51 l 103 01 } SG11 l 67 l 93 ROLL ROLL MAI 0.6 @ TSH + 0.61 l 104 01 i I SG11 l-68 l 22 } ROLL ROLL PPI 0.3 @ DH 5.3l 105 01 i ! SG111 68 I 30 l ROLL l ROLL PPI 0.5 @ 07H 16.8 l 106 01 1 SG11 l 68 36 i ROLL ROLL PPI 0.8 @ 08H 3.3l 107 01 l i SG11 68 42 ROLL ROLL PPI 0.4 @ 07H 1.1 108 01 l SG11 68 110 ROLL ROLL PP! 0.5 @ DH 4.2 109 01 i SG11 69 53 ROLL ROLL SAI 0.3 @ 07H 7.3 110 01 SG11 69 59 ROLUSTAB ROLL SCI 1 @ TSH + 0.10 111 01 4 SG11 69 87 ROLL ROLL sal 0.3 @ TSH + 0.58 112 01 l SG11 ~69 97 ROLL ROLL SAI 0.8 @ TSH 0.9 113 01 I SG11 69 99 ROLL ROLL SAI 0.3 @ TSH 0.7 114 01 i SG11 70 54 ROLUSTAB ROLL SCl 1.3 @ TSH + 0.01 115 01 i SG11 70 72 ROLL ROLL sal 0.4 @ VM O.8 116 01 i SG11 70 78 ROLL ROLL SAI 0.2 @ TSH + 0.52 117 01 1 SG11 70 82 ROLL ROLL SAI 0.3 @ TSH + 0.22 118 01 ! SG11 70 84 ROLL ROLL mal 0.5 @ TSH + 1.06 119 01 'G11 70 86 ROLL ROLL MAI 0.9 @ TSH + 0.36 120 01

-.. - - ~. ~ CCNPP UNIT 1 U1R12 P!.UGGING LIST i HOT COLD TUBE LIST S/G ROW LINE _ LEG ' LEG REASON FOR REPAlR COUNT REVISION SG11 70 94 ROLL ROLL MAI 0.5 @ TSH + 0.39 121 01 SG11 70 100 ROLL ROLL MAI 0.3 @ TSH 0.2 122 01 4 SG11 71 81 ROLL ROLL SAI 0.2 @ TSH + 0.68 123 01 SG11 71 85 ROLL ROLL MAI 0.7 @ TSH + 0.38 124 01 4 SG11 71 87 ROLL ROLL MAI 0.8 @ TSH + 0.46 125 01 SG11 71 91 ROLL ROT 1 MAI 0.5 @ TSH + 0.67 126 01 SG11 72 52 ROLUSTAB ROLL. SCI 0.3 @ TSH + 0.21 127 01 SG11 72 76 ROLUSTAB ROLL SCI 0.7 @ ' TSH + 0.00 128 01 } SG11 72 80 ROLUSTAB ROLL S CI'" 0.7 @ TSH + 0.07 129 01 SG11 72 84 ROLUSTAB ROLL SCI 0.2 @ TSH + 0.10 l 130 01 SG11 72 94 l ROLL ROLL SA!"' O.7 @ TSH + 0.43 1?1 01 SG11 73 61 l ROLUSTAB ROLL SCI 0.4 @ TSH + 0.11 132 01 SG11 73 61 l ROLL ROLL PPI 0.3 @ OH 3.8 133~ 01 i SG11 73 57 ROLL l ROLL mal 0.5 @ TSH - 0.59 134 01 l ] SG11 73 93 i ROLL l ROLL MAI 0.3 @ TSH - 0.EG 135 01 SG11 73 l 153 i ROLL l ROLL PPI 0.4 @ VH 3.2 136 01 SG11 74 l 75 ROLLrSTAB l ROLL SCI 0.2 @ TSH - 0.C5 137l 01 SG11 74 i E3 ROLL'ST AB l ROLL l SCI 0.6 @ TSh C. 0 138 01 l l SG11 74 I S ROLL l ROLL l sal 0.5 @ TSH 0.4 139 01 l l SG11 74 l 135 ROLL l ROLL lSA! 0.2 @ 08H 1.E 140 01 l SG11 75 l 15 ROLL ROLL . MAI 1.2 @ TSH. 0.55 141l 01 SG11 75 l 47 : ROLL < STAB ROLL SCI 0.8 @ TSH - 0.14 142 01 i SG11 75 63 ! ROLL ROLL PPI 0.8 @ VH 14.2 143 01 ! SG11 75 S3 ! ROLL ROLL mal 0.6 @ TSH - 0.35 144 01 ! SG11 76 l 65 l ROLL / STAB ROLL SCI 1 @ TSH + 0.07 145 01 ! SG11 76 93 ! ROLL ROLL sal 0.7 @ TSH + 0.34 146 01 i SG11 77 67 i ROLL / STAB ROLL ' SCI 1.4 @ TS H - 0.0 5 147 01 i SG11 77 71 l ROLUSTAB ROLL SCI 0.8 @ TSH + 0.10 i 148 01 l SG11 77 87 l ROLL ROLL MAI 1 @ TSH + 0.90 149 01 SG11 78 28 ROLL ROLL PPI 0.6 @ 08H 12.6 l 150 01 SG11 78 84 ROLL ROLL sal 0.7 @ TSH + 0.67 l 151 01 SG11 78 90 ROLL ROLL MAI 0.5 @ TSH 1.5 l 152 01 SG11 79 47 ROLUSTAB ROLL SCI 0.6 @ TSH + 0.09 l 153 01 SG11 79 87 ROLL ROLL sal 0.3 @ TSH + 0.57 154 01 1 SG11 80 46 ROLUSTAB ROLL SCI 0.2 @ TSH + 0.15 155 01 SG11 80 62 ROLL ROLL MSI 0.3 @ VH 9.5 156 01 SG11 80 100 ROLL ROLL PPI 0.3 @ DH 3.5 157 01 SG11 81 51 ROLUSTAB ROLL SCI @ TSH + 0.15 158 01 SG11 81 E9 ROLL ROLL sal 0.3 @ VH 13.6 159 01 SG11 81 63 l ROLL ROLL MSI 0.3 @ VH 10.4 l 160 01

,c ~ ~ ~ ~ ' " ^ ~ ~~ ^ J { CCNPP UNIT 1 U1R12 PLUGGING LIST REV01 Page _ f of 9 \\ HOT COLD 3 TUBE LIST ~ l i S/G ROW LINE LEG ~ LEG REASON FOR REPAIR COUNT REVISION SG11 81 67 ROLL ROLL MSI @ VH 8.9 161 01 ( SG11 81 69 ROLL ROLL MSI @ VH 7.7 162 01 1 SG11 81 75 ROLL ROLL SAI 0.5 @ VH 10.7 163 01 SG11 81 79 ROLL ROLL sal 0.2 @ VH 10.3 164 01 SG11 81 85 ROLL ROLL sal @ 06H + 19.35 165 01 SG11 81 107 ROLL ROI.L sal 0.2 @ 07H S.8 166 01 4 SG11 81 111 ROLL ROLL PPI 0.2 @ 08H 13.8 167 01 SG11 82 40 ROLL ROLL MSI 0.3 @ 08H 2.7 168 01 s 3 SG11 82 46 ROLUSTAB i ROLL S CI O3 @ TSH + 0.33 169 01 SG11 82 100 ROLL l ROLL PPI 0.5 @ DH 26 170 01 SG11 82 138 ROLL ROLL MSI' O.2 @ 06H 2.2 17.1 01 SG11 83 89 ROLL l ROLL SAI 0.2 @ VH 7.7 172 01 SG11 83 111 ROLUSTAB ! ROLL SCI 0.4 @ TSH C.* 173 01 l SG11 83 i 145i ROLL ROLL ' PPI

0. 9 @ DH
3. ' l 174 01 l

l SG11 84 82 l R.C,LL ROLL SAI 0.3 @ 06H 1C.2 l 175 01 l i SG11 l 84 110l ROLUSTAS ROLL l SCI 0.4 @ TSH C.:l 176 01 } , l SG11 I 84 l 114 i ROLL ROLL MSI 1.1 @ VH 14.~ ] 177 01 i { SG11 I 85 l 47 l R O LL'STA S ROLL SCI 0.4 @ TSH + 0.04 l 178 01 l ' SG11 85 l 69 I ROLL ROLL MSI 0.4 @ 08H 10.5 l 179 01 l SG11 l 85 95 i ROLL ROLL (MSI 0.2 @ OSH 2."l 180 01 j SG11 85 123l ROLL ROLL SAI 0.2 @ VH 12.5 i 161 01 l SG11 85 125l ROLL ROLL sal 0.2 @ 07H 15. 1 182 01 i SG11 85 127l ROLL ROLL MSI 0.2 @ VH 3.3l 183 01 l S G11 86 l 32 l ROLL ROLL sal 0.2 @ 08H 15.3l 164 01 l SG11 86 60 l ROLL ROLL MSI 0.5 @ VH 6.5l 185 01 I SG11 86 64 ! ROLL ROLL MSI Of. @ VH 5.5l 186 01 } SG11 86 66 ROLL ROLL MSI 0.3 @ VH 3.5l 167 01 l SG11 86 70 ROLL ROLL MSI 0.4 @ VH 3.4 188 01 l SG11 86 112 ROLL l ROLL SAI 0.3 @ VH

2. 5 189 01 SG11 87 53 ROLUSTAB l ROLL SCI 0.4 @ TSH + 0.08 190 01

\\ SG11 87 69 ROLL l ROLL sal 0.4 @ VH 3.5 191 01 SG11 87 75 ROLL l ROLL SAI 0.4 @ VH 3.2 192 01 SG11 87 83 ROLL ROLL SA! 0.2 @ VH 9.9 193 01 SG11 88 68 ROLL ROLL SAI 0.2 @ VH 2.8 194 01 SG11 88 76 ROLUSTAB ROLL SCI 0.3 @ TSH + 0.08 195 01 SG11 90 112 ROLL ROLL sal 0.2 @ VH 16.2 196 01 SG11 90 116 ROLL l ROLL PPI 1.8 @ DH S.9 197 01 SG11 90 118 ROLUSTAB l ROLL SCI 0.6 @ TSH 0.1 198 01 SG11 90 128 ROLL I ROLL SAI 0.3 @ 08H 5.2 199 01 SG11 91 45 ROLUSTAB l ROLL SCI 1 @ TS H + 0.13 200 01

~... --.. =. CCNPP UNIT 1 U1R12 PLUGGING LIST HOT COLD TUBE LIST S/G ROW LINE LEG LEG REASON FOR REPAIR COUNT REVISION SG11 91 47 ROLUSTAB ROLL SCI 0.3 @ TSH 0.1 201 01 I SG11 91 61 ROLL ROLL SAI 0.2 @ VH 11.9 202 01 SG11 91 79 ROLL ROLL SAI 0.3 @ VH 3.1 203 01 f SG11 91 93 ROLL ROLL sal 0.5 @ VH 2.9 204 01 SG11 91 101 ROLL ROLL MSI 0.3 @ VH 1.7 205 01 SG11 92 100 ROLL RO4 L MSI 0.2 @ VH 12.2 206 01 ~ SG11 92 106 ROLL ROLL. MSI 0.5 @ 08H 1.8 207 01 SG11 92 114 ROLL ROLL ' MAI 0.2 @ VH 16.0 208 01 j SG11 92 116 ROLUSTAB ROLL MCI 0.2 @ TSH 0.1 209 01 SG11 92 128 ROLL l ROLL MSI 0.4 @ 06H 16.4 210 01 SG11 92 132 ROLL ROLL S AI 4 0.1 @ 08H 4.9 211 01 SG11 93 37 ROLL ROLL SAI 0.3 @ 09H 0.3 212 01 SG11 94 100 ROLL ROLL SAI 0.3 @ 09H 0.4 21:1 01 SG111 94 114l ROLL ROLL sal 0.6 @ DH 10.8l 214 l 01 ! SG11 95 l 93 l ROLL ROLL SAI 0.2 @ 09H 2.5l 215 01 ! SG11 96 l 58 l ROLL ROLL sal 0.2 @ VH E.5 l 216 01 SG11 l 96 l 68 l ROLL ROLL MSI 0.3 @ VH 5.7i 217l 01 SG11 l 96 1 74 l ROLL ROLL sal 0.2 @ VH 9.9l 216 01 { SG11 96 78 l ROLL ROLL sal 0.2 @ VH 2.5 l 219 i 01 l SG11 96 88 l ROLL ROLL SAI 0.3 @ VH 6.9l 220l Oi l , SG11 96 100 l ROLL ROLL sal 0.3 @ VH 6.0 1 221l 01 1 SG11 97 53 l ROLL / STAB ROLL SCI 0.9 @ TSH + 0.04 l 222 l 01 SG11 98 74 l ROLL ROLL MSI 0.2 @ OSH 9.6l 223 01 SG11 98 140 l ROLL ROLL PPI 0.2 @ 09H 11.9l 224 01 SG11 99 12h ROLL ROLL SAI 0.1 @ VH 2.4 l 225 01 SG11 99 131 ROLL i ROLL SAI 0.2 @ VM 11.1 l 226 01 SG11 100 56 F;OLL/ STAB ! ROLL SCI 0.8 @ TSH + 0.0S l 227 l 01 SG11 100 76 ROLL l ROLL MSI 0.3 @ DH 8.1 228 01 SG11 100 104 ROLL l ROLL MSI @ VH 2.3 229 01 SG11 100 140 ROLUL STAB ROLL SCI O.3 @ 09H 0.4 230 01 SG11 101 31 ROLL ROLL sal 0.2 @ 07H 5.6 231 01 SG11 101 45 ROLL ROLL MSI 0.4 '@ 06H 20.0 232 01 SG11 101 89 ROLL ROLL sal 0.2 @ 09H 0.2 233 01 SG11 101 125 ROLL ROLL sal 0.1 @ 08H 3.0 234 01 SG11 102 48 ROLL ROLL MSI 0.8 @ G1 4.3 235 01 SG11 102 66 ROLL ROLL MSI 03 C DH 11.6 236 01 SG11 102 70 ROLL ROLL SAI 0.2 @ DH 13.4 237 01 SG11 102 78 ROLL ROLL PPI 0.3 @ DH 4.8 238 01 SG11 102 134 ROLL ROLL PPI 0.2 @ DH 3.8 239 01 SG11 103 53 ROLL ROLL PPI 0.5 @ 09H 12.5 240 01

i CCNPP UNIT 1 U1R12 PLUGGING LIST HOT COLD TUBE LIST i S/G ROW LINE LEG ' LEG REASON FOR REPAIR COUNT REVISION SG11 103 63 ROLL ROLL SAI 0.3 @ DH 12.6 241 01 SG11 103 67 ROLL ROLL MSI 0.4 @ DH 8.7 242 01 SG11 103 7S ROLL ROLL SAI 0.4 @ DH 9.9 243 01 ) SG11 103 77 ROLL ROLL MSI 0.5 @ DH 6.8 244 01 ) SG19 103 81 ROLL ROLL MSI @ DH B.3 245 01 j SG11 103 85 ROLL ROLt. MSI 1.5 @ VH 3.7 246 01 SG11 103 87 ROLL ROLL SAI 0.4 @ VH-1.6 247 01 SG11 103 89 ROLL ROLL 'MSI 0.5 @ DH 7.8 248 01 SG11 104 42 ROLL ROLL SAI

  • 0.2 @ 07H 15.9 249 01 SG11 104 76 ROLL ROLL SAI 0.2 @ VH 7.9 250 01

{ SG11 104 84 ROLL ROLL S AI 's 0.6 @ 09H 0.0 25.1 01 i SG11 104 104 ROLL ROLL PPI 0.3 @ 09H 17.9 252 01 I SG11 105 41 ROLL ROLL sal 0.4 @ VH 3.31 2531 01 j. SG11 105l 87 ROLL ROLL MSI 0.4 @ DH 72: 254 l 01 , l SG11l 105I 95 ROLL I ROLL PPI 0.5 @ 09H

20. " !

2551 01 i SG111 105l 101 ROLL l ROLL MSI 0.4 @ OSH 6.6l 256 i 01 ] SG111 105 l 103 ROLL l ROLL MSI 0.4 @ 07H 2.7 i 257i 01 i ! ! SG11 i 105l 107 ROLL l ROLL PPI 0.1 @ 09H 17.6 1 258 i 01 i fI SG11 l 105 l 109 ROLL ROLL PPI 0.6 @ 09H 19.6 I 259l 01 I 3G11 l 105l 115 ROLL ROLL PPI 0.5 @ 09H 18.E i 2601 01 l I SG11 l 105l 117 ROLL ROLL sal 0.3 @ VH 3.2 i 261 ! 01 t I SG11 l 1061 42 ROLL l ROLL SAf 0.4 @ DH 2.2 !

262, 01 l

l SG11l 106 l 52 ROLL ROLL MSI 0.2 @ DH 16.0 1 2631 01 l !SG11l 106 l 58 ROLL ROLL SAI 0.4 @ DH 16.2 l 264 1 01 l i SC f1 106l 66 ROLL ROLL SA! 0.3 @ OBH 16.2 1 265l 01 l SG11 106 68 ROLL ROLL MSI 0.5 @ 09H 5.7 l 2661 01 l SG11 106 70 ROLL ROLL SAI 0.2 @ 09H 15.3 ! 267! 01 l SG11 106 78 ROLL ROLL sal 0.2 @ DH 15.3 i 268 1 01 ! SG11 106 100 ROLL ROLL SAI 0.3 @ 09H-0.0l 269 01 ! SG11 107 121 ROLL ROLL PPl 0.2 @ VH 7.01 270 01 lSG11 108 42 ROLL ROLL SAI 0.3 @ 09H-0.0 271 01 1 SG11 108 78 ROLL ROLL MSI 0.5 @ DH 14.1 272 01 ' SG11 108 80 ROLL ROLL-sal @ 09H 0.1 273 01 ! SG11 110 72 ROLL ROLL SAI 0.2 @ 09H 0.1 274 01 ! SG11 110 112 ROLL ROLL SAI 0.4 @ VH 1.7 275 01 lSG11 110 122 ROLL ROLL SAI 0.3 @ DH 13.3 276 01 ' SG11 111 125 ROLL ROLL sal 0.2 @ 07H 6.3 277 01 I SG11 112 50 . ROLL ROLL SAI 0.4 @ VH 3.4 278 01 . SG11 112 72 ROLL ROLL MSI 0.3 @ VH 3.2 279 01 'G11 112 102 ROLL ROLL PPI 0.7 @ OBH 18.5 l 280 01

CCNPP UNIT 1 U1R12 PLUGGING LIST HOT COLD S/G ROW LINE LEG LEG REASON FOR REPAIR COUNT REVISION TUBE LIST SG11 113 89 ROLL ROLL SAI 0.4 @ 09H 0.1 281 01 SG11 113 129 ROLL ROLL MSI 2 @ DH 10.7 282 01 ~ SG11 114 128 ROLL ROLL PPI 0.2 @ 08H 9.9 283 01 SG11 115 125 ROLL ROLL MSI 0.1 @ 08H 10.8 284 01 ~ SG11 116 110 ROLL ROLL sal 0.2 @ DH 22.6 285 01 SG11 121 55 ROLL ROQ MSI 0.2 @ OBH 15.9 286 01 ] l SG11 121 61 ROLL ROLL SAI 0.2 @ 07H 11.5 287 01 ~ SG11 121 63 ROLL ROLL SAI 0.1 @ 09H 0.5 288 01 ~ SG11 121 69 ROLL ROLL M SI., 0.3 @ 08H 6.2 289 01 SG11 121 71 ROLL ROLL SAI 0.1 @ 07H 6.1 290 01 SG11 121 111 ROLL ROLL SAI 0.3 @ OBH 6.6 ) 291 01 SG111 122 118 ROLL ROLL MSI 0.5 @ 07H 5.2l 292 01 m SG11 l 123 75 ROLL l ROLL MSI 0.6 @ 09H 2.8l 293-01 SG11 l 123 77 ROLL l ROLL IMSI 0.2 @ OEH 15.6 l 2M l 01 SG11 i 1231 79 l ROLL l ROLL !MSI @ OSH 22.3 ! 295 l C1 t SG11 123l 87 l ROLL i ROLL i PP) @ DH 19.2 I 296l C" SG11 123 l 109l. ROLL I ROLL !SAI 0.2 3 CEH 17.7 297 l C1 SG11 ! 1241 116 i ROLL I ROLL t MS! 0.2 @ 07H 18.4 298 l C1 SG11 124 120l ROLL I ROLL ! sal 0.3 @ 07H 9.5l 299 C1 3G11i 125l 93 ROLL l ROLL (MSI 0.3 @ OBH 2.8I 300 01 SG111 125 } 111 ROLL ROLL !SAI C2 @ VH 22.5 ! 301 C1 SG11 l 128 78 ROLL ROLL I M A! 0.2 @ 09H 0.21 302 Ci SG11 I 128 86 ROLL l ROLL IMSI @ OS H 11.0 l 303 Ci SG11 l 128 104 l ROLL I ROLL lMSI 0.2 @ DH 13.8 l 304 C1 SG11 l 128 110l ROLL / STAB l ROLL ! SCI 0.3 @ TSH 0.1l 305 Ci SG11 l 128 114 I ROLL l ROLL lLPI @ TSH 0.6l 306 C' _S G11 l 129 97 l ROLL I ROLL iSAI @ O!H 0.6I 307 C' 1 SG11 l 129 109 l ROLL l ROLL ILPI @ TSH 0.3l 308 C1 SG11 129 113 ROLL ROLL 'LPI @ TSH 0.7 309 C1 SG11 129 115 ROLL ROLL LPI @ TSH 0.2 310 01 SG11 130 56 ROLL ROLL MSI 0.2 @ OBH 14.1 311 01 SG11 130 106 ROLL ROLL MSI 0.2 @ 07H 8.9 312 01 _ SG11 130 114 ROLL ROLL LPI @ TSH 0.8 313 01 SG11 133 57 ROLL ROLL sal @ 10H 0.2 314 01 SG11 134 104 ROLL ROLL VOL 1.1 @ 07H 25.2 315 01 SG11 139 93 ROLL ROLL SAI 0.8 @ TSH 4.8 316 01 SG11 139 95 ROLL ROLL sal 0.6 @ TSH 0.G 317 01 t

) .o CCNPP UNIT 1 U1R12 PLUGGING LIST s. I HOT COLD lS/G ROW, LINE ' LEG LEG ! TUBE LIST 1 . REASON FOR REPAIR l COUNT, REVISION d 3 NOTES: Revision 01 of this plug list represents the initial plug. s list for this steam generator to facilitate the start of plugging. The following tubes were re, moved from Revision 00 of this list and 4 do not require repair: R27 L7, R38-L32, and R36 L38. Other repair locations will be added at a later date. i . Alllocations have been reviewed for tube expansion anomalies. j The following locations have expansion anomalies in the indicated leg-j I ROW LINE LEG 75 15 HOT 139 93 HOT 139 95 HOT i APPROVALS

AMATOME TECHNOLOGIES PREDARER:

'fDN h k 6/V/f6 FRAMATOME TECHNOLOGIES REV, EWER:.,/// [ t/ FA b d ',b I EG&E APPROVAL': D h f( k y l ~// \\ 7 n-d l 4 i 1 i i 4 i 4 4 e

1 l REV02 Page_ / of / CCNPP UNIT 1 U1R12 PLUGGING LIST I HOT . COLD TUBE LIST t S/G ROW LINE LEG LEG REASON FOR REPAIR COUNT REVISION SG11 9 115 ROLL ROLL sal 0.3 @ VM-2.9 318 02 SG11 15 167 ROLL ROLL SV1 @ TSH 0.1 319 02 ) SG16 SG11 16 166 ROLL ROLL SVI @ TSH 0.1 320 02 i 43 67 ROLL ROLL MSI 0.4 @ 06H 14.6 321 02 SG11 45 101 ROLL RQLL sal @ 07H 2.4 322 02 SG11 52 86 ROLL ROi.L PPI @ DH 1.5 323 02 SG11 52 102 ROLL ROLL %PPI @ 07H 16.4 324 02 SG11 56 92 ROLL ROLL MSI @ 07H 14.8 325 02 SG11 l 59 83 ROLL ROLL

SVl"

@ TSH 0.1 326 02 l l SG11 i 66 92 ROLL ROLL S Al. 0.2 @ DH-5.5 327 02 I SG11 i 83 91 ROLL ROLL mal 0.3 @ VH 3.8 328 02 { l SG11 i 87 91 ROLL ROLL MSI 0.3 @ VH 9.6 329 02 l SG11 91 l 91 } ROLL ROLL MSI 0.6 @ VH 2.6 330 02 l SG11 95 t 129l ROLL ROLL PPI 0.4 @ DH 4.0 331 IN SITU i SG11 1001 88 l ROLL /L STAB ROLL lSCl 0.5 @ 09H 0.4 332 IN SITU SG11 103I 127l ROLL ROLL SAI 0.3 @ DH 13.0 333 02 ' SG11 105! 127l ROLL ROLL MSI 0.3 @ DH 11.0 334 02 i l ! SG11 108 I 90 l ROLL ROLL MSI 0.2 @ DH 9.5 335 02 SG11 113I 127l ROLL ROLL MSI 0.9 @ DH 3.1 336 02 , SG11 115! 41 l ROLL ROLL

sal 0.4 @ DH 10.7 337 02 NOTES Revision 02 of this plug list represents the FINAL plug hst for this steam cenerator.

All locations have been reviewec for tube expansion anomaliac No tubes on this !!st revision have expansion anomalies. APPRCVALS FRAMATOME TECHNOLOGIES PREPARER: 6 b FRAMATOME TECHNOLO IES REVIEV CR: [ // ' Mif/1 b BG&E APPROVAL: _ en 5 r / W i

_ _ ~ _.. _. _ _ _ _ _ - _.. _ _ _ _ _ _. _., e s ) 1 CCNPP UNIT 1 U1R12 PLUGGING LIST HOT COLD TUBE LIST S/G ROW LINE LEG LEG REASON FOR REPAIR COUNT REVISION SG11 3 123 ROLL ROLL SVi @ TSH 0.5 338 03 SG11 27 7 ROLL ROLL SVI @ TSH 3.5 339 03 SG11 49 109 ROLL ROLL SVI @ TSH 1.5 340 03 I, 1 NOTES: Revision 03 of this plug list represents the FINAL plug list for this steam generator. Alllocations have been reviewed for t'Obe expansion anomalies. No tubes on this list revision have expansion ancmalies. APPROVALS i FRAMATOME TECHNOLOGIES PREPARER: 1 /,-N.06 FRAMATOME TECHNOL R 'IEWE / /W NA [~/fN-C !'V bf, SG&E APPROVAL: ( / / ,}}