Notice of Violation from Insp on 960908-1026.Violation Noted:Significant Condition Adverse to Quality Identified on Nonconformance Notice 5344,dtd 960314 & Corrective Actions to Prelude Repetition Not Accomplished
ML20135A393
Person / Time
Site: Summer 
Issue date: 11/25/1996
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20135A379 List:
References
50-395-96-11, NUDOCS 9612030202
Download: ML20135A393 (2)


Text

.

NOTICE OF VIOLATION South Carolina Electric & Gas Company Docket No. 50-395 V. C. Summer Nuclear Station License No. NPF 12 During an NRC inspection conducted on September 8 through October 26, 1996, a violation of NRC requirements was identified.

In accordance with the " General Statement of Policy and Procedures for NRC Enforcement Actions,"

NUREG 1600, the violation is listed below:

10 CFR 50 Appendix B Criterion XVI, Corrective Actions, as implemented by the licensee's quality assurance program, South Carolina Electric &

Gas Company Operational Quality Assurance Plan, Revision 22, collectively require that for significant conditions adverse to quality, measures shall be implemented to assure that the cause of the condition is determined and corrective actions taken to preclude repetition.

Contrary to the above, a significant condition adverse to quality was identified on Non conformance Notice (NCN) 5344, dated March 14, 1996, and corrective actions to preclude repetition were not accomplished.

The significant adverse condition was a solenoid valve failure which resulted in an inoperable Train A Charging Pump. The licensee's determined cause was a design control error which installed an under rated valve for system conditions. Although the adverse condition was promptly corrected, the NCN did not provide corrective actions for the root cause, the design control error.

This is a Severity Level IV violation (Supplement I).

Pursuant to the provisions of 10 CFR 2.201, South Carolina Electric & Gas Company is hereby required to submit a written statement or explanation to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, D.C. 20555 with a copy to the Regional Administrator, Region II, and a copy to the NRC Resident Inspector at V. C. Summer, within 30 days of the date of the letter transmitting this Notice of Violation (Notice). This reply should be clearly marked as a " Reply to a Notice of Violation" and should include for each violation:

(1) the reason for the violation, or, if contested, the basis for disputing the violation, (2) the corrective steps that have been taken and the results achieved. (3) the corrective steps that will be taken to avoid further violations, and (4) the date when full compliance will be achieved.

Your response may reference or include previous docketed correspondence, if the correspondence adequately addresses the recuired res)onse.

If an adequate reply is not received within the time specifiec in this iotice, an order or a Demand for Information may be issued as to why the license should not be modified, suspended, or revoked, or why such other action as may be proper should not be taken. Where good cause is shown, consideration will >e given to extending the response time.

Because your res>onse will be placed in the NRC Public Document Room (PDR), to the extent possiale, it should not include any personal privacy, aroprietary, or safeguards information so that it can be placed in the PDR witlout ENCLOSURE 1 9612030202 961125 PDR ADOCK 05000395 G

PDR

l NOV 2

3 redaction.

If personal privacy or proprietary information is necessary to provide an acceptable response, then please provide a bracketed copy of your response that identifies the information that should be protected and a l

redacted copy of your response that deletes such information.

If you request withholding of such material, you must s)ecifically identify the portions of your response that you seek to have withield and provide in detail the bases for your claim of withholding (e.g., explain why the disclosure of information l

will create an unwarranted invasion of personal privacy or provide the information required by 10 CFR 2.790(b) to support a request for withholding confidential commercial or financial information).

If safeguards information is necessary to provide an acceptable response, please provide the level of L

protection described in 10 CFR 73.21.

Dated at Atlanta, Georgia this 25 day of November 1996 i