ML20134P421

From kanterella
Jump to navigation Jump to search
Discusses Conclusions & Forwards Safety Evaluation Re 1985 Steam Generator Tube Insps & Repair,Per 850501 Meeting W/Util & Util 850612 & 0712 Ltrs Concerning Eddy Current Testing & Tube Repair
Date released: 05/27/2020 Download: ML20134P421


Safety Evaluation Supporting Chemical Cleaning of Steam Generator Tubes,Based on 1985 Eddy Current Insps & Substantiating Previous Favorable Evaluation of Acceptability of Sleeving as Tube Repair Method
ML20134P422
Person / Time
Site: Millstone Dominion icon.png
Issue date: 08/19/1985
From:
Office of Nuclear Reactor Regulation
To:
References
Download: ML20134P422 (5)
Discusses Conclusions & Forwards Safety Evaluation Re 1985 Steam Generator Tube Insps & Repair,Per 850501 Meeting W/Util & Util 850612 & 0712 Ltrs Concerning Eddy Current Testing & Tube Repair
ML20134P417
Person / Time
Site: Millstone Dominion icon.png
Issue date: 08/19/1985
From: Butcher E
Office of Nuclear Reactor Regulation
To: OPEKA J F
NORTHEAST NUCLEAR ENERGY CO.
References
Download: ML20134P417 (2)