ML20134M817

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-483/96-10 on 961021-1209 & Notice of Violation
Date released: 05/27/2020 Download: ML20134M817


Insp Rept 50-486/96-10 on 961021-1209.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant Support
ML20134M827
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/14/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20134M827 (83)
Notice of Violation from Insp on 961021-1209.Violation Noted:Analysis of Plus Point Probe Eddy Current Data During Refueling Outage RF8 Not Controlled to Assure Use of App H Qualified Settings for Span & Phase Rotation
ML20134M824
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/14/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20134M824 (2)
Forwards Insp Rept 50-483/96-10 on 961021-1209 & Notice of Violation
ML20134M814
Person / Time
Site: Callaway Ameren icon.png
Issue date: 02/14/1997
From: Gwynn T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: SCHNELL D F
UNION ELECTRIC CO.
References
Download: ML20134M814 (6)