Forwards Safety Evaluation Re Results of in-plant Tests of HPCS Svc Water Pump to Confirm Acceptability of Mechanical & Flow Inducted Vibrations.Vibration Levels Small & within Acceptable Limits
Date released: 05/27/2020 Download: ML20134K461


Safety Evaluation Re Review of in Situ Operational Test Rept on HPCS Svc Water Pump.Vibration Levels of Pump Small & within Acceptable Limits
ML20134K469
Person / Time
Site: Grand Gulf 
Issue date: 08/23/1985
From:
NRC
To:
References
Download: ML20134K469 (3)
Forwards Safety Evaluation Re Results of in-plant Tests of HPCS Svc Water Pump to Confirm Acceptability of Mechanical & Flow Inducted Vibrations.Vibration Levels Small & within Acceptable Limits
ML20134K457
Person / Time
Site: Grand Gulf 
Issue date: 08/23/1985
From: Novak T
Office of Nuclear Reactor Regulation
To: RICHARD J B
MISSISSIPPI POWER & LIGHT CO.
References