ML20134H015

From kanterella
Jump to navigation Jump to search
First Partial Response to FOIA Request for Documents. Documents Listed in App a Available in Pdr.Forwards Documents Listed in App B.Documents in App C Copyrighted & Available for Insp Only at PDR
ML20134H015
Person / Time
Site: San Onofre 
Issue date: 10/28/1996
From: Pugh N
NRC OFFICE OF ADMINISTRATION (ADM)
To: White M
AFFILIATION NOT ASSIGNED
Shared Package
ML20127A865 List:
References
FOIA-96-354 NUDOCS 9611130489
Download: ML20134H015 (8)


Text

U.S. NUCLEAR REGULATORY COMMISSION NRC FOIA REQUEST NUMBER (S)

N(>

FOIA 354

.e RESPONSE TYPE RESPONSE TO FREEDOM OF l FiNA' l^ I PARTIAL

( l s I.)

( %..e INFORMATION ACT (FOIA) REQUEST

$U 2 E 1995 DATE DOCKET NUMBER (S) tilapolocable)

\\

- REQUESTER Michael L. White PART 1.-AGENCY RECORDS RELEASED OR NOT LOCATED (See checkedbores)

No agency rec'ords subject to the request have been located.

No cdditional agency records subject to the request have been located.

Requested records are available through another public distribution program. See Comments section, b

Agency records subject to the request that are identified in Appendix (es)

A are already available for public inspection and copying at tl

.X NRC Public Document Rmm,2120 L Street, N.W., Washington, DC.

l Agency records subject to the request that are identified in Appendix (es)

B are being made available for public inspection and copying X

at the NRC Public Document Room,2120 L Street, N.W., Washington, DC, in a folder under this Fot A number.

The nonproprietary version of the proposal (s) that you agreed to accept in a telephone conversation with a member of my staff is now being made available for public inspection and copying at the N RC Public Document Room,2120 L Street, N.W., Washington, DC, in a foldet under this FOI A number.

Agency records subject to the request that are identified in Appendix (es) may be inspected and copied at the NRC Local Public Document Room identified in the Comments section.

Enclosed is mformation on how you may obtain access to and the charges for copying records located at the NRC Public Document Room,2120 L Street, y

N.W., Washington, DC.

~X Agency records subject to the request are enclosed.

  • Records subject to the request have been referred to another Federal agency (ies) for review and direct response to you, i

Fees You will be billed by the NRC for fees totaling $

i' You will receive a refund from the NRC in the amount of $

g a view of N RC's response to this request, no further action is being taken on appeal letter dated

, No.

PART 11. A-INFORMATION WITHHELD FROM PUBLIC DISCLOSURE Cert:In information in the requested records is being withheld from public disclosure pursuant to the axemptions described in and for the reasons stated in Pcrt II, B, C, and D. Any released portions of the documents for which only part of the record is being withheld are being made available for public insoection and copying in the NRC Public Document Room,2120 L Street, N.W., Washington, DC in a folder under this FOIA numbe -

X)MMEN IS

  • Copies of the records identified on Appendit B are enclosed. The records identified on Appendix A are available for inspection and copying at the NRC's Public Document Room (PDR).

The records identified on Appendix C are copyrighted and are available for inspection ONLY at the PDR.

The review of additional records subject to your request is continuing.

D I A

Vf REpOM OF 1[ORMATION AND PUBLICATIONS SERVICES TDIRECTOQDIION

.I U

. m 4.

A

[

4

'3 W

4 iW' 1

9611130489 961023 PDR FOIA m

WHITE 96-354 PDR

,,,.en.u m...

n,.on

. ~ -

l l

FOIA-96-354' APPENDIX A (PDR Available)

See screen printouts attached.

t I

1 I

i l

\\

l l

< <NIfDOCS /AD> >

Nrflear Rsgulctory Commission Version 002.000

TCON8======== Full Dc;a Record Display W/Dancrip on=================

l Accaccion #: 8702020135 Availability: PDR Format: TXT

' Documsnt Type: TIIEIN Date of Issue: C70204 Number of Pages:

107pp.

l Dasc/: IE Info Notice 87-008, " Degraded Motor Leads in Limitorque DC Motor l

Title:

Operators." Svc list encl.

i l

Size: A4 LPDR: Y Backfit:

  • 24X:
  • Index Date: 870210 Security:

l Authors Docket #s Reference Numbers Page Rev i NIEEM JORDAN,E.L.

05000000 INN IEIN-87-008 05000003 l

05000010 l

Recipients Dates Task Numbers Distribution l

l EMVOPS l EUTACEC

! EUTALPR File Locations / Levels File Packages Microfilm Addresses l CF SUBJ 870204 8702020135 #

PDR 39575 032-39575 138

(

PDR I&E NOTICE 87-008 870204 CF SUBJ ID&R-11C IEIN 870204 Una HOME/ TAB To View Additional Information, ENTER To View Text, Escape To Exit.

Char Mode: Replace Page 1 Count:

  • 0 i

I l

I t

P

\\

t i

i b

l 2

i l

.<<NUDOCS/AD>>

Ne e r Regulatory Commission Version 002.000

TCON8======== Full DL a Record Dicplcy W/Dancrip. on======,==========

Accacnion #: 8703310090 Availability: PDR Format: TXT Document Typn: TIIEIN' Date of Innue: 870402 Numba,r of Pages:

108pp.

Desc/: IE Info Notice 87-016, " Degradation of Static O-Ring Pressure

,l

Title:

Switches." Svc list encl.

Size: A4 LPDR: Y Backfit:

  • 24X:
  • Indsx Date: 870407-Security:

Authors Docket #s Reference Numbers Page Rev JORDAN,E.L.

05000000 INN IEIN-87-016

! NIEEM EUTCEIL 05000003 l*

EUTCLEI 05000010 l

l Recipients-Dates Task Numbers Distribution l EMVOPS l EUTACEC EUTALEC File Locations / Levels File Packages Microfilm Addresses l CF SUBJ 870402 8703310090 #

PDR 68841 021-68841 025 PDR I&E NOTICE 87-016 870402

! CF SUBJ ID&R-11C IEIN 870402 L Use HOME/ TAB To. View Additional Information, ENTER To View Text, Escape To Exit.

Char Mode: Replace Page 1 Count:

  • 0 1

k i

i f

I s

I d

.<<NUDOCS/AD>>

Nr. ear Regulatory Commission Version 002.000

TCON8======== Full Dh.a Record Display W/Descripu_on=================

Acccenion #: 8811150088 Availability: PDR

_ Formet: TXT Documant Typn: TIIEIN Date of Icsue: 881121 Number of Pages:

117pp.

. DDec/: NRC Info Notice 88-089, " Degradation of Kapton Ele'ctrical Insulation."

Title:

Svc list encl.

. Backfit:

  • 24X:
  • Size: A4 LPDR: Y Indnx Date: 881129 Security:

Authors Docket #s Reference Numbers Page Rev NRRBTA ROSSI,C.E.

05000000 INN IEIN-88-089 05000003 ITN

'IEIN-87-008 05000010 ITN IEINl-87-016 Recipients Dates Task Numbers Distribution EMVOPS EVD 870615 EUTALPR EUTBECO File Locations / Levels File Packages Microfilm Addresses CF SUBJ 881121 8811150088 #

PDR 47603 045-47603 161 PDR-I&E NOTICE 88-089 881121 CF SUBJ ID&R-11C IEIN 881121 Uso HOME/ TAB To View Additional Information, ENTER To View Text, Escape To Exit.

Char Mode: Replace Page 1 Count:

  • 0 4

i 4

1 l

l I

i 1

l

[

F01A-96-354 APPENDIX B i

(RECORDS RELEASED) 1.

12/17/84 NRL Memorandum Report 5508, Flashover Failures from Wet-Wire Arcing and Tracking (24 pages) 2.

6/23/87 Memorandum for C.E. Rossi from Dennis Kirsch,

Subject:

Potentially Generic Issues RV-87-04, Deterioration of Insulation on CONAX Containment Penetrations at San Onofre Unit 1 (2 pages) 3.

7/10/87 Letter to NRC from H.E. Morgan enclosing Licensee Event Report 87-008-00 (4 pages) 4.

7/22/87 Memorandum for Charles Rossi from Edward Jordan,

Subject:

Vendor Correspondence Related to in 87-08 and 87-16 and Qualification of Kapton Insulation Material enclosing 7/2/87 letter to Edward Jordan from G. Robert McKay (6 pages) 5.

8/25/87 Letter to CONAX Buffalo Corp from J.T. Reilly enclosing Southern California Edison Company, Report Number l

FR-067094, 6/17/87 (11 pages)

'6.

12/29/87 Memorandum for J. Stone from Wayne Lanning,

Subject:

Transfer of Operating Event Long-Term Followup with enclosure (5 pages) 7.

2/23/88 Letter to NRC from T.P. Schaefer and R.E. Dulski with enclosure (3 pages) 8.

3/30/88 Southern California Edison Company, Interim Design Change Notice, ABG-1636 (2 pages) 9.

7/12/88 Memorandum for Docket File 9990323 from Richard Wilson

Subject:

Inspection 88-01, Visit to CONAX Buffalo on February 10-11, 1988 (? pages) 10.

8/3/88 Handwritten Note (1 page) 11.

8/12/88 Facsimile Transmission to R.C. Wilson from L. William Buxton enclosing 8/12/88 Recent Media Coverage of Kapton l

Polyimide Film (3 pages) j

l 2

)

l 12.

8/18/88 Lei.ter to Richard Wilson from L. William Buxton (1 page) 13.

8/30/88 Letter to Richard Wilson from L. William Buxton enclosing Helpful Hfnts for Handling Wire and Cable Insulated with Kapton (9 pages) 14.

9/88 Draft NRC Information Notice No. 88-XX: Improper Application of Kapton Electrical Insulation (17 pages) l 15.

9/14/88 Handwritten Note (1 page) 16.

9/16/88 Handwritten Note (1 page) q 17.

9/16/88 Letter to NRC from R.E. Dulski (2 pages) l 18.

10/5/88 Telephone Call Recorc (5 pages)

Kapton Polyimide Film, Safety in Handling and Use (4 pages) 19.

20.

Kapton Polyimide Film, Summary of Properties (28 pages)

DuPont Materials for Wire & Cable, Kapton, Bulletin H-110-62 21.

Tape Width and Taping Angle Guide Charts (6 pages) 22.

Bulletin H-110-63, Heat Sealing Wire Insulated with Kapton Polyimide Film - Type F (4 pages)

DuPont Materials for Wire & Cable, Kapton, Bulletin H-110-61 23.

Taping of Wire Insulated with Kapton Polyimide Film (4 pages) 24.

Kapton Polyimide Film Radiation Resistance (4 pages) i 25.

Handwritten Raychem Data (1 page) 26.

CONAX Electric Penetrations at Work Since 1972 (1 page)

CONAX, Temperature Sensors and Assemblies, Seals for Wires and 27.

Probes (48 pages) 28.

CONAX Serves Nuclear Power Worldwide (23 pages) j 29.

Handwritten Note to Mr. Potapovs from Stan J (1 page) i L

i i

i i

I

F01A-96-354 APPENDIX C

~

(COPYRIGHTED RECORDS) 1.

Polyimide Film Insulation For Aerospace Wire and Cable: Why Long-Term Performance Exceeds Some Limited Laboratory Projections by John 0. Punderson, Ph.D.,

Consultant and James F. Heacock, Ph.D., Research Associate (7 pages) 2.

9/12/87 Article from the Washington Post, " Test Raise Concern About Aircraft Wiring (1 page) 3.

7/88 EPRI EL/NP/CS-5914-SR " Proceedings: Workshop on Power Plant Cable Condition Monitoring", Electric Power Research Institute (SEE PAGES 24-1 THROUGH 24-17) l 4.

7/88 Kapton Polyimide Film: Its Continued Use as a Wire Insulation System (4 pages) 5.

7/24-26/88 Article. from the Fort Worth Star-Telegram, " Wired for i

Disaster" (12 pages) 6.

8/19/88 Article from the Fort Worth-Star Telegram, " Reactor has Difficulties with Kapton" (1 page) 7.

8/22/88 Article from the Fort Worth Star-Telegram, " Restrict Kapton Use, Pentagon Panel Says (2 pages) l 8.

7/30/88 Article from the Fort Worth Star-Telegram, " Army Phasing l

Out Use of Explosive Insulation (2 pages) 9.

8/7/88 Article from the Fort Worth Star-Telegram, Kapton llarning In Works (1 page) i l

4