Mr. Charles H. Cruse February 7, 1997

.Vice President - Nuclear Energy Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 I

SUBJECT:

RELIEF REQUEST FROM THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) CODE REQUIREMENTS TO DELAY REPAIR OF LEAK IN A PIPING SUPPORT ATTACHMENT ON THE SAFETY INJECTION RECIRCULATION PIPING, CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT N0. 1 (TAC N0. M97438)

Dear Mr. Cruse:

The NRC staff has reviewed the Baltimore Gas and Electric Company's (the licensee's) submittal of December 19, 1996.

The licensee proposed an alternative to the ASME Code Section XI requirement IWA-5250 to repair a leak near a piping support attachment weld on the safety injection recirculation piping in the Unit 1 component' cooling pump room. The licensee intends to repair the flaw during the next refueling outage in the spring of 1998 and submitted an evaluation.to show that delaying the repair would not compromise safety.

The licensee requested relief based on 10 CFR 50.55a(a)(3)(i).

The NRC staff rev.iewed the subject request for relief and concluded that the use of the. alternative method is authorized pursuant to 10 CFR 50.554(a)(3)(ii) as compliance with the-ASME Code requirements would result in hardship or upusual difficulties:without a compensating increase in the level of quality or sa,fety. A copy ~of our Safety Evalu,ation is enclosed.

Sincerely,

/S/

S. Sing'h'Bajwa, Acting Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No:

50-317

Enclosure:

Safety Evaluation cc w/ enc 1: See next page k

1 S. Bajwa gh PUBLIC S. Little PDI-I R/F A. Dromerick

\\h(

S. Varga 0GC J. Zwolinski ACRS

!)

f M. Banic L. Doerflein, Region I

1 1

DOCUMENT NAME:

G:\\CCl-2\\M97438.SE 100054 To receive a copy of this document, indicate in the box:

"C" - Copy w/ copy ithout attachment / enclosure "E" = Copy _with attachment / enclosure "N" y'pp 0FFICE PM; poi-A /

lE LA:PDI-1d)-

l I D:PDI-1

/gl l

OGC M l

l NAME A0tomer4ck/rs t SLittle."

SBajwa fW A N l. CW DATE 02/ 9 /97 02/d /97 02/ 7 /97 02/ ( 797 9702100438 970207

'clal Record Copy PDR ADOCK O'C00317 P

PDR

f aun UNITED STATES y

NUCLEAR REGULATORY COMMISSION f

WASHINGTON. D.C. 30006-0001

%g..... /

February 7, 1997 Mr. Charles H. Cruse Vice President - Nuclear Energy Baltimore Gas and Electric Company Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702

SUBJECT:

RELIEF REQUEST FROM THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) CODE REQUIREMENTS TO DELAY REPAIR OF LEAK IN A PIPING SUPPORT ATTACHMENT ON THE SAFETY INJECTION RECIRCULATION PIPING, CALVERT CLIFFS NUCLEAR POWER PLANT, UNIT NO. 1 (TAC NO. M97438)

Dear Mr. Cruse:

The NRC staff has reviewed the Baltimore Gas and Electric Company's (the licensee's) submittal of December 19, 1996. The licensee proposed an alternative to the ASME Code Section XI requirement IWA-5250 to repair a leak near a piping support attachment weld on the safety injection recirculation piping in the Unit 1 component cooling pump room. The licensee intends to repair the flaw during the next refueling outage in the spring of 1998 and submitted an evaluation to show that delaying the repair would not compromise safety. The licensee requested relief based on 10 CFR 50.55a(a)(3)(i).

The NRC staff reviewed the subject request for relief and concluded that the use of the alternative method is authorized pursuant to 10 CFR 50.55a(a)(3)(ii) as compliance with the ASME Code requirements would result in hardship or unusual difficulties without a compensating increase in the level of quality or safety. A copy of our Safety Evaluation is enclosed.

Sincerely, S. Singh Bajwa, Acting Director Project Directorate I-1 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No:

50-317

Enclosure:

Safety Evaluation cc w/ encl:

See next page

s Mr. Charles H. Cruse Calvert Cliffs Nuclear Power Plant Calvert Cliffs Nuclear Power Plant Unit Nos. I and 2 cc:

President Mr. Joseph H. Walter, Chief Engineer Calvert County Board of Public Service Commission of Commissioners Maryland 175 Main Street Engineering Division Prince Frederick, MD 20678 6 St. Paul Centre Baltimore, MD 21202-6806 D. A. Brune, Esquire General Counsel Kristen A. Burger, Esquire Baltimore Gas and Electric Company Maryland People's Counsel P.O. Box 1475 6 St. Paul Centre Baltimore, MD 21203 Suite 2102 Baltimore, MD 21202-1531 Jay E. Silberg, Esquire Shaw, Pittman, Potts, and Trowbridge Patricia T. Birnie, Esquire 2300 N Street, NW Co-Director Washington, DC 20037 Maryland Safe Energy Coalition P.O. Box 33111 Mr. Terrence J. Camilleri, Director, Baltimore, MD 21218 NRM Calvert Cliffs Nuclear Power Plant Mr. Larry Bell 1650 Calvert Cliffs Parkway NRC Technical Training Center Lusby, MD 20657-47027 5700 Brainerd Road Chattanooga, TN 37411-4017 Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 287 St. Leonard, MD 20685 Mr. Richard I. McLean Administrator - Radioecology Department of Natural Resources 580 Taylor Avenue Tawes State Office Building, B3 Annapolis, MD 21401 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406