Forwards Insp Repts 50-254/96-17 & 50-265/96-17 on 961027-1206 & Nov.Three Apparent Violations Were Identified & Being Considered for Escalated Enforcement Action
Date released: 05/27/2020 Download: ML20134G109


Insp Repts 50-254/96-17 & 50-265/96-17 on 961027-1206.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support
ML20134G123
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 02/04/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20134G123 (30)
Notice of Violation from Insp on 961027-1206.Violation Noted:Incorrect Bolts Used in 1C & 2C safety-related RHR Svc Water Low Pressure Pumps
ML20134G119
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 02/04/1997
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
References
Download: ML20134G119 (2)
Forwards Insp Repts 50-254/96-17 & 50-265/96-17 on 961027-1206 & Nov.Three Apparent Violations Were Identified & Being Considered for Escalated Enforcement Action
ML20134G107
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 02/04/1997
From: Caldwell J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: KRAFT E
COMMONWEALTH EDISON CO.
References
Download: ML20134G107 (4)