January 31, 1997
Mr. E. Watzl, Vice President
Nuclear Generation
Northern States Power Company
414 Nicollet Mall
Minneapolis. MN 55401
SUBJECT:
NRC INSPECTION REPORT NO. 50-263/96012(DRP)
Dear Mr. Watzl:
On January 8. 1997, the NRC completed an inspection at your Monticello reactor
facility. The enclosed report presents the results of that inspection.
During the 6-week seriod covered by this inspection period, your conduct of
activities at the ionticello facility was generally characterized by safety-
conscious operations sound engineering and maintenance practices, and careful
i
radiological work controls.
The decision to shutdown the reactor to repair
j
the "D" safety relief valve was proactive and demonstrated a good safety
perspective.
Your staff conducted the shutdown in a controlled manner and
repaired several existing material condition concerns.
A rapid )ower reduction necessitated by a loss of condenser vacuum occurred
during t1is period. This was attributed to a failure to fully consider the
effect of frigid air from open turbine building doors on nearby equipment.
This issue will be further assessed during the next inspection period.
No violations or deviations from NRC requirements were identified during this
inspection period.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice." a copy of
this letter and its enclosures will be placed in the NRC Public Document Room.
1
Sincerely.
1
/s/ J. L. Caldwell
'
James Caldwell. Director
Division of Reactor Projects
/)k L['L
)
Docket No. 50-263
8
9
g
yj
{3
,
License No. DPR-22
Enclosure:
Inspection Report
No. 50-263/96012(DRP)
PLEASE SEE ATTACHED CONCURRENCES
DOCUMENT NAME:
R:\\INSPRPTS\\ POWERS \\MONT\\ MON 96012.DRP
reeive a copy of this doctment. indicate in the box "C" = Copy without attach / encl T* = Copy with attach / encl
"N" =
OFFICE
RIII
RIII
NAME
Jacobson/co
Caldwell
DATE
1/ /97
1/ /97
0FFICIAL RECORD COPY
9702100263 970131
ADOCK 05000263
0
.
,
Mr. E. Watzl, Vice President
Nuclear Generation
Northern States Power Company
414 Nicollet Mall
Minneapolis MN 55401
SUBJECT:
NRC INSPECTION REPORT NO. 50-263/96012(DRP)
Dear Mr. Watzl:
On January 8, 1997, the NRC completed an inspection at your Monticello reactor
facility.
The enclosed report presents the results of that inspection.
During the 6-week period covered by this inspection period your conduct of
activities at the Monticello facility was generally characterized by safety-
conscious operations, sound engineering and maintenance practices, and careful
radiological work controls. The decision to shutdown the reactor to repair
the "D" safety relief 'talve was proactive and demonstrated a good safety
perspective.
Your staff conducted the shutdown in a controlled manner and
repaired severdi existing material condition concerns.
A rapid 3ower reduction necessitated by a loss of condenser vacuum occurred
during t11s period.
This was apparently attributed to a failure to fully
consider the effect of frigid air from open turbine building doors on nearby
equipment.
This issue will be further assessed during the next inspection
period.
No violations or deviations from NRC requirements were identified during this
inspection period.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice." a copy of
this letter and its enclosures will be placed in the NRC Public Document Room.
l
Sincerely.
James Caldwell. Director
Division of Reactor Projects
Docket No. 50-263
License No. DPR-22
Enclosure:
Inspection Report
No. 50-263/96012(DRP)
DOCUMENT NAME:
R:\\INSPRPTS\\ POWERS \\MONT\\ MON 96012.DRP
To receive a copy of this document. indicate in the box "C" = Copy without attach /enci "E" = Copy with attach / enc 1
"N" =
OFFICE
RIII_ s
f'RII[ .
NAME
Jadot>sM
CMMli
DATE
lbb
1[9/97
0FFICIAL RECORD COPY
. . . .-_ - . _ . - _ .
- - . .
.
-
- . _
..
. _ _ _
l
.
.
s
E. Watz1
-2-
.
cc w/ encl: . Plant Manager. Monticello
John W. Ferman, Ph.D..
Nuclear Engineer. MPCA
.
State Liaison Officer. State
of Minnesota
Distribution:
Docket File w/ encl
DRP w/ encl
PUBLIC IE-01 w/ enc 1
Rill PRR w/ encl
l
OC/LFDCB w/ encl
Project Manager. NRR w/ encl
i
SRI Monticello, w/ encl
Prairie Island w/ encl
}
A. B. Beach, w/ encl
H. B. Clayton, w/ enc 1
j
W. L. Axelson, w/ encl
CAA1 w/ encl (E-mail)
!,
,
)
s
I
i
.i
4
4
i
i