Insp Rept 50-333/85-13 on 850429-0503.No Violations Noted. Major Areas Inspected:Action on Previous Insp Findings, Records & Document Control Programs & Facility Mods
ML20134E642
Person / Time
Site: FitzPatrick 
Issue date: 08/13/1985
From: Eapen P, Oliveira W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20134E621 List:
References
50-333-85-13, NUDOCS 8508200355
Download: ML20134E642 (9)


See also: IR 05000333/1985013

Text

{{#Wiki_filter:. . U. S. NUCLEAR REGULATORY COMMISSION REGION I Report No. 50-333/85-13 Docket No. 50-333 License No. DPR-59 Licensee: New York Power Authority P. O. Box 41 Lycoming, New York Facility Name: James A. FitzPatrick Nuclear Power Plant Inspection At: Scriba, New York Inspection Conducted: April 29 - May 3, 1985 Inspector: d' N .$ [[ ~

W. Oliveira, Reactor Engineer 'da te' Approved by: 4.EdpA /3/f5~ Dr. P.K. Eapen, Chief, Quality cfate ' Assurance Section, OB, DRS Inspection Summary: Routine unannounced inspection conducted on April 29 - May 3,1985 (Report No. 50-333/85-13). , Areas Inspected:

Licensee action on previous inspection findings; records and document control programs; and facility modifications. The inspection involved 56 hours onsite inspection by one region based inspector and a supervisor. Results: No violations were identified. 8508200355 850814 ~ ' PDR ADOCM 05000333 G PDR

. . 1 DETAILS 1.0 Persons Contacted New York Power Authority

  • R. Baker, Technical Services Superintendent
  • W. Childs, Senior Nuclear Licensing Engineer

P. Contempio, Facility Manager

  • R. Converse, Superintendent of Power

W. Fernandez, Operations Superintendent

  • H. Glovier, Resident Manager
  • R. Patch, Quality Assurance Superintendent
  • B. Prucnal, Office Manager

H. Riley, Design Draftsman

  • V. Walz, Senior Plant Engineer Supervisor
  • E. Zufelt, Draf ting Supervisor
  • Denotes those present at the exit interview

2.0 Action on Previous Inspection Findings (Closed) Open Item (333/78-14-06): Schedule for full implementation of ANSI N45.2.9-1974 for records management. The licensee has completed the implementation of an ANSI N45.2.9-1974 Records Management Program in early 1985. Based on the review of the licensee's newly established records management program detailed in paragraph 3 of this report, this item is closed. (Closed) Open Item (333/84-11-02): Revise Component Quality Assurance (QA) Classification Procedure to incorporate generic review and human factors consideration. Licensee has incorporated this information in the Engineer- ing and Design Procedure (EDP) - 12. This item is closed. (0 pen) Open Item (333/84-11-03): Perform engineering evaluation on equip- ment in the warehouse prior to use in Category I system if equipment is not in the Preventive Maintenance Program. Licensee has issued a new mainten- ance procedure MPT-28 on the subject and revised Work Activity Control Pro- cedure (WACP)-10.1.5 accordingly. The implementation of this program will be reviewed during a future NRC inspection. This item remains open pending implementation review by the NRC.

r . . 3 3.0 Records and Document Control 3.1 Requirements / References 1. ANSI N18.7-1972, Administrative Controls for Nuclear Power Plants. 2. ANSI N45.2.9-1974, Requirements for Collection, Storage, and Maintenance of Quality Assurance Records for Nuclear Power Plants. 3. ANSI N45.2.11-1974 Quality Assurance Requirements for the Design of Nuclear Power Plants. 4. FitzPatrick Technical Specifications Section 6. 5. FSAR Chapter 13 and 17. 6. New York Power Authority (NYPA) Quality Assurance Program Manual. 7. Plant Standing Order (PS0) 4, Rev. 2, Quality Assurance Operating Records. 8. PSO 5. Rev. O, Control of Drawings and Technical Manual. 9. PS0 41, Rev. O, Operation of Archival Storage Facility. 10. Work Activity Control Procedure (WACP) 10.1.1, Rev. 9, Work / Event / Deficiency / Form. 3.2 Program Review The inspector reviewed the licensee's Quality Assurance Records and Document Control programs. These programs were established to meet the requirements of the documents referenced in paragraph 3.1. The licensee's procedures adequately identified the records and documen- tation including drawings required to be maintained and tracked. Re- sponsibilities and controls for storage and filing, transfer, reten- tion, maintenance and disposition of records and documents are also identified and assigned in the licensee's procedures. 3.3 Program Implementations and Findings The inspector verified the implementation of the QA Records and Docu- ment Control Programs by reviewing the records in several department storage areas and the records in the storage vault. The document con- trol center personnel: (1) readily retrieved any records or documents, including microfiche located in specific areas throughout the plant. i

(. . . 4 (2) controlled the receipt and verification of records including changes and supplemental information. (The inspector reviewed Quality Control Inspection Reports (QCIRS) being submitted to Document Control Coordinator by the QA Department. These records will be stored as microfiche). (3) controlled the access to files and the accountability of records. (4) were knowledgeable of the retention requirements and the dis- position of records. The primary document for the control and maintenance of records /docu- ments is the Records Retention Schedule. Various computerized indices, such as, the Construction Index, do exist. A handwritten drawing in- dex is available for cross-reference between vendor drawings and their corresponding NYPA drawings. The storage vault was inspected. This vault met the requirements of a single storage facility discussed in ANSI N45.2.9-1974, Paragraph 5.6. The temperature and humidity gage and drum chart were not permanently insti ' led. They were being moved from place to place in the newly buil vault to determine the average temperature and humidity readings. Temperature / humidity information was recorded daily in the inspection checklist. Access to the vault is controlled by the Document Control Coordinator. The permanent records received in the vault include the original contract orders (AP-D); welder qualifications, radiographs, material tests reports, mechanical equipment check lists, and general inspections reports. The following records and documents were reviewed to verify proper implementation of the programs: Quality Control Inspection Reports (QCIRs). QCIRs were being -- made ready for microfilming. The backlog for processing QCIRs was unsatisfactory by the licensee's own goals. Approximately ten such QCIRs were dated prior to September 1983. The oldest i work order, WRED 71/20727 was dated May 2, 1983. QCIRs involving i modifications (Mods) are turned over to the Technical Services Department to be processed with the Mod package. Without the QCIR, the Mod package is incomplete and cannot be closed out. The licensee is investigating the QCIR backlog and the status of WRED 71/20727. This is an unresolved item (50-333/85-13-01)

pending licensee's completion of the investigation and action to

reduce QCIR backlog. , i Reportable Occurrences related to NRC Information Notices (IN), IE i Bulletins (IEB), Inspection Reports (IR), and Licensee Event Reports (LERs). !

r- . . 5 IN 85-12, IN 85-17, IN 85-20, IN 85-22, IN 85-23, IN 85-24,

and IN 85-26 IEB 84-03, LERs 85-03, 85-04, 85-05, 85-06, and 85-08

IR 78-14, IR 82-16, IR 82-24, and IR 84-11.

Surveillance test records, of F-ST-24A, RCIC Class III Piping -- Pressure Test; F-ST-9F, Emergency Diesel Generator System Air Start Piping; and F-ST-390, Reactor- Building Leak Rate Test. Operational logs and records such as NCO Logs, Reactor Building -- Log, Computerized Balance of Plant Log and the Alarm Typer. -- Hand written drawing index to verify the status of vendor drawings from General Electric Company. The inspector verified the revision of the following Analog Transmitter Trip System (ATTS) Mod drawings yere correct: 718E846BA; 729E589BA; 865E365 (sheet 5); an'd 913E714 (sheet 5). The Technical Services Engineer is responsible for the control of plant drawings in accordance with PS0 5. A key element in the com- puterized control effort is the assignment of NYPA numbers to the plant drawings. The inspector reviewed 25 procedures in the areas of Operations, Instrumentation and Control (I&C), and Maintenance. Almost all of the procedures were issued in 1985. The review however, indicated that the procedures referenced vendor drawing numbers _instead of NYPA numbers. A sample of these vendor drawings was checked against the hand written drawing index. These drawings had corresponding NYPA numbers. A licensee representative stated that the vendor drawing numbers will be changed to NYPA numbers in l future procedure revisions. The new procedures will reference NYPA drawing numbers. Personnel training records of ten employees were reviewed. The , individual training records were in a three ring binder, indexed, legible, complete, current and readily accessible. l ' The inspector also observed the following activities: Data entry on Work Tracking Form (WTF) No. 9 for Maintenance l -- Procedure (MP) T-21 Discharge Test of Replacement Station

Battery Cell Type NCX-2400.

-- On site preparation by the Quality Control (QC) inspector to witnass the disassembly of the RHR Service Water pump in ac- , = cordance with MP-10.4, QC checklist and QC Inspection Report (QCIR). 1 . .- . - _ - _-- - - . - - ' -

. .- . 6 Filing of hard copies that could not be microfiched and the -- filing of the poor quality microfiche of Batch 8257. ' No violations were identified. 3.4 QA/QC Interface Eight audits regarding records and document control were conducted in 1984. Review of these audits and their files indicated the following: The formal audit reports contained the audit details, attributes, results, and request for corrective action. These audit reports were issued within three days of completion of the audit. Corrective action resp'onse was adequate and was submitted within two weeks. Verification of corrective action was timely. The Projected Audit Schedule for 1984-1985 indicated that the scope for 1985 audits is the same as that for 1984. The corrective action audits verified LER corrective actions. It was noted that the corrective action audits did not include the drawings and records control concerns identified in the NRC inspection 50-333/82-24. (See paragraph 4.4 below for the details of the NRC concerns.) The QA personnel stated that they would expand the scope of audits especially in the hardware implementation and the corrective action verification areas. 4.0 Facility Modification 4.1 References / Requirements FSAR Section 17 -- Technical Specifications -- Regulatory Guide 1.64 (October 1973) -- ' ANSI N45.2.11-1974 -- ANSI N18.7-1972 -- NRC Inspection Report 50-333/82-24 -- 4.2 Details The plant modification program was reviewed against the requirements of the documents identified in paragraph 4.1 using Modification FI-83-018, Analog Transmitter Trip System (ATTS). It was determined that the licensee had established the following: . -. .- . -

( .- . 7 -- A method for initiating, reviewing, and controlling modifi- cations and temporary changes. The documentation of modification activities including those for -- 10 CFR 50.59 safety evaluations. Measures to delineate responsibilities and control interfaces -- among participating organizations. 4.3 QA/QC Interface QA Department reviews the modification package and identifies the quality requirements including the witness points by QC Inspection. Quality Control Inspection Reports (QCIRs) are submitted by the QA Department as part of the completed (closed) modification package. A QA audit sampled two drawings affected by a modification change and found that their revisions were processed in a timely manner. Addi- tional QA audits are discussed in paragraph 3.4. 4.4 Findings The inspector reviewed the status of problems encountered during the ATTS modification and found these problems were or are being satis- factorily resolved. Given below is a summary of the findings from this review: I Problem Disposition 1. Brand Rex Cable had lower Replaced this cable with other than expected insulation qualified cable. resistance. 2. One Reel of Brand Rex Cable Did not use this reel. Vendor had cracked insulation. provided a new reel. QA investi- gating the circumstances that led to this problem. 3. Wiring of Panel 9-21 not per Resolved by Engineering Change drawing. Request (ECR) Nos. FI-82-53-147 and 165. , 4. Instrument Racks Required Resolved by ECR Nos. FI-82-53-147 , ~ rework to facilitate operability and 165. and maintenance. ,

J h . - . , -o- , , _ _ , ,..m.,..- . .. .-, ,, - - . . _ _ _ . , _ , _ _ . _ , - . . - . - _ . . _ _ _ , _ , _ _ _ _ - . . - - . ,n. - , , --

F ,- . 8 5. One Main Steam Line Corrected. Differential Pressure instrumen- tation was improperly installed 6. HPCI Level 8 Switch Problem Replaced the Switch. 7. Several Cables were Resolved by ECR No. F1-82- incorrectly cut. 053-162. 8. TOPAZ inverters were bad. Design change to use DC to DC devices instead of inverters. The inspector verified the status of resolution for the drawing revision back log reported in NRC Operational Assessment Team (0AT) Inspection Report (No. 50-333/82-24). The licensee's corrective action was to reduce the back log using a plan reported in JAFP Letter 82-0869 tfated August 6, 1982. However, as of May 3, 1985, the licensee has completed less than sixty percent of the drawings scheduled for update in 1984. If the present trend continues, the licensee will not be able to meet the 1985 schedule. This back log is further increased by the 1985 outage, which required more than three thousand drawings to be revised. The White Plains Office Support to the drawing revision efforts appeared to have lost the initial level of attention. Additional corporate management attention is required to meet the drawing revision goal. In response to another 0AT concern, the licensee provided a draft revision to the Plant Standing Order (PS0) No. 5 for the NRC review. This draft revision contained measures to provide better on-site control for the drawings and records. However, this draft was never formally issued. The licensee representatives informea the inspector that the 0AT report will be reviewed for action items, a status of all action items will be established and each action item will be tracked to completion. The inspector stated to the licensee's representatives that the above item (i.e. drawing revision back log and revision of PS0 5) remains unresolved pending completion of licensee action in this regard (50-333/85-13-02). 5.0 Unresolved Items Unresolved items are matters about which more information is required in order to ascertain whether they are acceptable items, items of noncomplf- ' ance, or deviations. Two unresolved items were identified during the l inspection and are discussed in sections 3.3 and 4.4 respectively. ! l , ! L

( ,. . 9 6.0 Exit Meeting The inspectors met with the licensee staff (attendees denoted in paragraph 1) on May 3, 1985, to discuss the scope and findings as de- tailed in this report. The licensee representatives acknowledged the inspectors' findings. At no time during this inspection was written material provided to the licensee by the inspector. }}