ML20134B752

From kanterella
Jump to navigation Jump to search
Responds to TAR ,transmitting Two Ltrs ,from Illinois Dept of Nuclear Safety & & 960427 from SA Huber Consultants,Inc Re Use of Contaminated Sands
ML20134B752
Person / Time
Issue date: 05/24/1996
From: Cool D
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Pederson C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20134B755 List:
References
FOIA-96-409 NUDOCS 9606060156
Download: ML20134B752 (2)


Text

~ ~ - -

i n.

I s

y, g >* R f Cg 4

r r

/,k i i t

UNITED STATES l

l

.J NUCLEAR REGULATORY COMMISSION i

Eyj i

os-wom :

a-Mr:

m j

(

l l

MEMORANDUM TO:

Cynthia D. Pederson, Director l

Division of Nuclear Materials. Safety, RIII l

FROM:

Donald A. Cool, Director J l

Division of Industrial and, P-i l

Medical Nuclear Safety,-NMSS I

SUBJECT:

TECHNICAL ASSISTANCE REQl'EST; STATE OF ILLIN0IS; USE OF DU CONTAMINATED SANDS IN TRANSPORT CONTAINERS I am respondin_g to your technical assistance request (TAR) dated June 27, 1995 (Attached), transmitting two letters dated June 1, 1995, from the Illinois Department of Nuclear Safety (IDNS) and letters dated June 7, 1995, and April 27, 1996, from Stan A. Huber Consultants, Inc. (SAHClj, an Illinois radioactive material licensee.

IDNS has requested NRC's evaluation of a proposal forwarded by SAHCI.

i SAHCl has requested authorization to receive sand and soil contaminated with depleted uranium (DU) which SAHCl proposes to mix with high density concrete in steel drums. According to the information supplied by SAHCI, the concrete mix would be poured into these drums leaving a center void space so that the 4 drums could be used as shielded Type A shipping containers. The DU contaminated sand / soil is a byproduct (waste) generated by another Illinois licensee's manufacturing process.

SAHCl indicates it will need a license to receive the DU contaminated sand / soil because the concentration of source material could be as high as 2000 picocuries p~r gram thus exceeding the

" unimportant quantity" limit of 0.05 percent provided in 10 CFR 40.13(a).

In its April 27, 1995, letter, SAHCl indicates it believes that recipients of these shipping containers would be exempt from 10 CFR Part 40 licensing requirements for the DU because of certain exemptions provided in 10 CFR 40.13, " Unimportant Quantities of Source Material."

In particular, SAHCl provides that it intends to mix in sufficient concrete and dilute the 00 sand / soil to ensure tht the concentration of Du in the mix will be less than 0.05 percent. Thus users of the containers would be exempt pursuant to 10 CFR 40.13(a).

SAHCl also states that the containers would be marked,

" Caution - Radioactive Shielding - Uranium" and that the drums are constructed of."a mild steel or equally fire resistant metal with a minimum wall thickness of one-eight inch."

By including this information SAHCl is indicating that users would also be exempt pursuant to 10 CFR 40.13(c)(6) or equivalent Illinois regulations.

Contact:

J. Bruce Carrico, NMSS (301) 415-7826

/'

\\

f,

- Xf1

s e

a I ?ederson 2

,,y After evaluating SAHCI's request, in collaboration *sth Robert Fonner from NRC's Office of the Generak Counsel, we have concluded that none of the exemptions provided in 10 CFR 40.13 would apply in this circumstance.

First, we note, in agreement with Region 111, that the low DV concentrations would add little, if any, additional shielding and that the proposal has the I

appearance of a process to dispose of licensed 9U.

The containers would not be exempt from licensing under the pro /ision of 10 CFR 40.13(a), (less than 0.05%), because of NRC's longstanding understanding that 10 CFR 40.13(a) does not allow dilution for purposes of disposal.

We note that the DU would have started out as "pura" DU metal and obviously was under license.

Further, the containers would not be exempt from licensing under prnvision of 10 CFR 40.13(c)(6), in part, because this provision specifies that the uranium i

must be encased in mild steel, as well as being effective shielding.

According to Attachment 3 enclosed with SAHCI's April 27th letter, the drum void space is created using a cardboard Sono Tube and the DU/ concrete mix is not encased near the drum top or at the bottom of the Sono Tube.

in conclusion, the containers SAHCl describes do not qualify for exemption under 10 CFR 40.13 and, therefore, must be treated as containing regulated material.

You may wish to inform IDNS that NRC does not issue "E-type" distribution licensc' for the source material products.

IDNS may also want to note that SAHCI would need a license to receive and possess the DU contaminated sand / soil regardless of DU concentration.

~

Attachment:

TAR dtd 6/27/95

'