ML20134A173

From kanterella
Jump to navigation Jump to search
Forwards LER 96-025-00 Re Operability Calculations Performed on ECCS Suction Strainers W/Incorrect Head Loss Values
Date released: 05/27/2020 Download: ML20134A173


:on 961220,discovered Original Value for Strainers Head Loss Incorrect.Cause Could Not Be Determined. Training Provided for Operators to Recognize Pump Cavitation During Design Basis Accidents
ML20134A188
Person / Time
Site: Quad Cities 
Issue date: 01/22/1997
From: Peterson C
COMMONWEALTH EDISON CO.
To:
References
Download: ML20134A188 (5)
Forwards LER 96-025-00 Re Operability Calculations Performed on ECCS Suction Strainers W/Incorrect Head Loss Values
ML20134A170
Person / Time
Site: Quad Cities 
Issue date: 01/22/1997
From: Pearce L
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML20134A170 (1)