,y August 7, 1985 4 O / f.
Docket No. 50-309 Mr. J. B. Randazza Executive Vice President Maine Yankee Atomic Power Company 83 Edison Drive Augusta, Maine 04336
Dear Mr. Randazza:
SUBJECT:
REACTOR TRIP SYSTEM RELIABILITY - ITEMS 4.2.1 AND 4.2.2 0F GENERIC LETTER 83-28 We have completed our review of your submittals dated January 25, 1985 and November 10, 1983 concerning Items 4.2.1 and 4.2.2 of Generic Letter 83-28.
Our contractor, The Idaho National Engineering Laboratory (INEL),
participated in that review. The Safety Evaluation is enclosed.
We find your position on Items 4.2.1 and 4.2.2 of Generic Letter 83-28 acceptable.
Sincerely,
/S/
Edward J. Butcher, Acting Chiet Operating Reactors Branch No. 3 Division of Licensing
Enclosure:
As stated cc w/ enclosure:
See next page Distribution:
Docket File NRC & L PDRs Branch Files HThompson ACRS 10 OELD PKreutzer PSears EButcher EJordan BGrimes g
[L ORB 8,3:DL ORB 3:DL ORB #3:DL Pjtrebtrer PSearstef EButcher y/.)/85
'6 / 1 /85
$/ 7/85 8500140516 050007 PDR ADOCK 05000309 P
Mr. J. B. Randazza Maine Yankee Atomic Power Company Maine Yankee Atomic Power Station cc:
Charles E. Monty, President Mr. P. L. Anderson, Project Manager Maine Yankee Atomic Power Company Yankee Atomic Electric Company 83 Edison Drive 1671 Worchester Road Augusta Maine 04336 Framingham, Massachusetts 07101 Mr. Charles B. Brinkman Mr. G. D. Whittier Manager - Washington Nuclear Licensing Section Head Operations Maine Yankee Atomic Power Company Combustion Engineering, Inc.
83 Edison Drive 7910 Woodmont Avenue Augusta Maine 04336 Bethesda, Maryland 20814 John A. Ritsher, Esquire Ropes & Gray 225 Franklin Street Boston, Massachusetts 02110 State Planning Officer Executive Department 189 State Street Augusta, Maine 04330 Mr. John H. Garrity, Plant Manager Maine Yankee Atomic Power Company i
P. O. Box 408 Wiscasset, Maine 04578 REgionalAdministrator,RegionI U.S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406 First Selectman of Wiscasset Municipal Building U.S. Route 1 Wiscasset, Maine 04578 Mr. Cornelius F. Holden Resident Inspector i
c/o U.S. Nuclear Regulatory Commission P. O. Box E l
Wiscasset, Maine 04578 i
t l
. _ _ _ _. _ -