Text
.
A Qg George S. Thomas
~
Vice Presdent-Nucleor Producten ruise s.ne. or n nampe*.
Ntw Hampshire Yankee Division SBN-884 T.F. B2.1.!, 2.1.9 I
October 24, 1985 United States Nuclear Regulatory Commission Washington, DC 20555 i
Attention: John G. Davis, Director Office of Nuclear Katerial Safety and Safeguards i
Reference:
(a) Construction Permit CPPR-135, Docket No. 50-443 (b) PSNH letter (SBN-854) dated August 1, 1985, i
" Application for Special Nuclear Material License for Seabrook Station - Unit 1," G. S. Thomas to J. G. Davis (c) NRC letter dated September 30, 1985, " Request for Additional Information Regarding Seabrook Station Unit I t
Application for Special Nuclear Riterial License,"
K. K. Kodali to G. S. Thomas T
Subj ect:
Amendment to Application for Special Nuclear Etterial License for Seabrook Station - Unit 1
Dear Sir:
Pursuant to your request for additional information (Reference c) below please find our response to each of your concerns. Attached are the amended pages to our application (Reference b) which incorporate these responses.
1.
See amended Table 1.1.4-1 (attached).
2a, b.
See amended page 10 (attached), first paragraph.
2c.
See amended page 10 (attached), second paragraph.
2d.
See added page 10a (attached), first paragraph.
I 8510280416 851024 PDR ADOCK 07003027 C
PDR i
Bool i
P.O. Box 300
- Soobrook, NH O3874. Tolephono(603)474-9521 O R.
i t
United States Nuclear Regulatory Commission October 24, 1985 Attention:
Director of Nuclear Material Safety Page 2 and Safeguards 2e.
See added page 10a (attached), second paragraph.
3a.
See amended page 25 (attached), first paragraph.
3b.
See amended page 26 (attached), first paragraph.
3c.
See amended page 26 (attached), second paragraph.
4.
See added page 21a (attached).
See amended page 12 (attached), first paragraph.
5.
See amended page 22 (attached), third paragraph.
6.
See added page 19a (attached).
7.
No application amendment necessary.
See subsection 2.2.7, page 29, second paragraph.
8.
See added page 28a (attached).
9.
See amended page 16 (attached), first paragraph.
10.
See added page 31a (attached).
11.
See amended page 32 (attached), first paragraph.
12a.
See amended page 34 (attached), first parag ra ph.
12b.
No application amendment necessary. This information is contained in Reference 5 of our original application submittal.
12c, d.
See subsection 3.5 of our original application submittal.
1 United States Nuclear Regulatory Commission October 24, 1985 Attention: Director of Nuclear Material Safety Page 3 and Safeguards We trust that is information will satisfactorily resolve your concerns; however, should you require any additional in forma tion, please contact us.
Very truly yours, AyLj w
George S. Thomas GST/cj b Attachments cc: Atomic Safety and Licensing Board Service List United States Nuclear Regulatory Commission Washington, DC 20555 Attention:
Mr. George W. Knighton, Chie f Licensing Branch No. 3 Division of Licensing United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Richard W. Starostecki, Director