ML20133N141
| ML20133N141 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 08/07/1985 |
| From: | Wenzinger E NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Opeka J NORTHEAST NUCLEAR ENERGY CO. |
| Shared Package | |
| ML20133N144 | List: |
| References | |
| NUDOCS 8508130388 | |
| Download: ML20133N141 (2) | |
See also: IR 05000245/1985019
Text
- _ _ _ - _ .
. ki *
AUG 0 719td
Docket Nos. 50-245
50-336
Northeast Nuclear Energy Company
ATTN:
Mr. John F. Opeka
Senior Vice President - Nuclear
Engineering and Operations Group
Post Office Box 270
Hartford, Connecticut 06141-0270
Gentlemen:
Subject:
Inspection 50-245/85-19; 50-336/85-25 (6/30/85 - 7/22/85)
This routine safety inspection was of operational and supporting activities at
"
Millstone Units 1 and 2.
Particular attention was directed to events surrounding
a loss of pressure scram at Millstone Unit 2.
No. violations of NRC requirements were identified and no reply to this letter is
required.
Your letter of June 18, 1985 concerning Steam Generator tube plugging and sleeving
I
at Millstone Unit 2 has been received and reviewed.
Additional NRC follow-up of
I
. steam generator conditions and performance will occur during routine inspections,
,
but we have no questions at this time.
Your cooperation with us is appreciated.
Sincerely, gn g;,
3i nod 3p}
S
WA8l
Edward C. Wenzinger, Chief
rojects Branch No. 3
,
Division of Reactor Projects
l
l
Enclosure:
NRC Region I Report 50-245/85-19; 50-336/85-25
cc w/ encl:
E.J. Mroczka, Vice President, Nuclear Operations
'
W.D. Romberg, Station Superintendent
D.0. Nordquist, Manager of Quality Assurance
R.T. Laudenat, Manager, Generation Facilities Licensing
Gerald Garfield, Esquire
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
State of Connecticut
ffY
P
\\
G
,.
. .
.
. .
..
.
.
.
.
_.
.
__________
_ - -
--
c..
e6:::
e,
AUG 0 71985
Northeast' Nuclear. Energy Company
2
+
bec w/ encl:
Region I Docket Room (with concurrences)
- S;nbr C;,e. .U v .. ^iT;m, 'w/; ;;; b)
Director DRS
Director DRS&S
DRP Section Chief
.
RI:DRP
RI:DRP
RI:
@
G
{
Shedl,W
osky-
McCabe
p Wenz
er
'
7/M/85
ght
{
87
At
.
OFFICIAL RECORD COPY
_ _ _ _ _ _ _ _ _ _ _ _ . - _ _ _ _ _ .
--- a