Application for Amend to License DPR-3,adding Two Containment Isolation Valves to Table 3.6-1 for Compliance W/Tech Spec 3/4.6.2 Which Requires Type C Tests for Valves. Fee Paid
ML20133K445
Person / Time
Site: Yankee Rowe
Issue date: 10/15/1985
From: Heider L
YANKEE ATOMIC ELECTRIC CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20133K448 List:
References
FYR-85-109, NUDOCS 8510220024
Download: ML20133K445 (2)


Text

,

YANKEE ATOMIC ELECTRIC COMPANY whonM617) 8 72-8100 TWX 710-380-7619 2.C.15.1 1671 Worcester Road, Frammgham, Massachusetts 01701 dm_

f FYR 85-109 s

.t/dVKf.4..

PC #190 October 15, 1985 United States Nuclear Regulatory Commission Washington, DC 20555 Attention:

Office of Nuclear Reactor Regulation

Reference:

(a) License No. DPR-3 (Docket No. 50-29)

Subject:

Addition of Containment Isolation valves to Table 3.6-1 (section C - Manual valves) of the Technical Specifications

Dear Sir:

Pursuant to Section 50.59 of the Commission's Rules and Regulations, the Yankee Atomic Electric Company hereby requests the authorization to make the following change.

Proposed Change Reference is made to the Technical Specifications of License No. DPR-3.

We propose to add two containment isolation valves to Table 3.6-1 (see attached) in order that these valves comply with Technical Specification 3/4.6.2, which requires Type C tests for containment isolation valves.

Reason and Basis for Change A hard-piped containment breathing air system wilt be installed during the 1985 refueling to be used for maintenance activities requiring supplied air. A three-quarter inch line will penetrate the containment (through a spare eight-inch penetration) in order to supply the breathing air. The arrangement of the containment isolation valves meets the requirements of 10CFR, Part 50, Appendix A, Criterion 56, which requires one locked, closed isolation valve inside containment and one locked, closed I?olation valve outside containment. Test taps also permit convenient Type C tests for these valves, as defined in 10CFR50, Appendix J, and required by Technical Specification 3.6.2.

Safety Consideration The significant hazards consideration is based on the guidance provided by axample in 48FR14870. The changes described herein are classified according to the following example of action involving no significant hazards:

A change that constitutes an additional limitation, restriction or control not presently included in the Technical Specifications, for example, a more stringent surveillance requirement.

tsa 8510220024 851015 JO 09 PDR ADOCK 05000029

\\

L P

pg M

r j

United States Nuclear Regulatory Commission October 15, 1985 Attention: Office on Nuclear Reactor Regulation Page 2 This change constitutes an additional limitation not presently included in the Technical Specifications. However, this change ensures containment integrity is preserved by enabling these new containment isolation valves to conform to the acceptance criteria for Type C tests, as required by Technical Specification 3.6.2.

This change does not result in any increase to the probability or consequence of a previously analyzed accident or reduce in any way a safety margin.

Based on the consideration contained herein, it is concluded that there is reasonable assurance that operation of the Yankee plant consistent with the proposed Technical Specification will not endanger the health and safety of the public. This proposed change has been reviewed by the Nuclear Safety Audit and Review Committee.

Fee An application fee of $150.00 is enclosed, in accordance with 10CFR170.21.

Schedule of Change These changes to the Yankee Technical Specifications will be implemented upon Commission approval. We request approval of this submittal by July 15, 1985.

We trust that you will find this submittal satisfactory; however, should you have any questions, please contact us.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

. H. Heider Vice President LHH/mec COMMONWEALTH OF MASSACHUSETTS)

)ss MIDDLESEX COUNTY

)

Then personally appeared before me, L. H. Heider,-who, being duly sworn, did state that he is a Vice President of Yankee Atomic Electric Company, that he is duly authorized to execute and file the foregoing document in the name and on the behalf of Yankee Atomic Electric Company and that the statements therein are true to the best of his knowledge and belief.

r'b d N h w Robert H. Groce Notary Public My Commission Expires August 29, 1991 t

L