ML20133J067

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept Re Seismic Qualification of CRD Mechanism Shroud.Initially Reported on 840820.Shroud Adequate as Intervening Structural Supporting Element.Item Not Reportable Per 10CFR50.55(e)
ML20133J067
Person / Time
Site: Seabrook  NextEra Energy icon.png
Issue date: 07/25/1985
From: Johnson W
PUBLIC SERVICE CO. OF NEW HAMPSHIRE
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
SBN-847, NUDOCS 8508090639
Download: ML20133J067 (3)


Text

-

. . F =, .

MI Wendell P. Johnson Vice President Pub 5c Service of New Hampshire New Hampshire Yankee Division July 25, 1985 SBN- 847 T.F. Q2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention: Mr. Richard W. Starostecki, Director Division of Project and Resident Programs

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of August 20, 1984, A. L. Legendre, Jr. (YAEC) to J. Grant (Region I)

(c) PSNH Letter ABN-719, dated September 26, 1984, " Interim 10CFR50.55(e) Report: CRDM Shroud," J. DeVincentis to R. W. Starostecki (d) PSNH Letter SBN-736, dated December 6, 1984, " Interim 10CFR50.55(e) Report: CRDM Shroud," J. DeVincentis to R. W. Starostecki (e) PSNH Letter SBN-763, dated February 19, 1985, " Interim 10CRF50.55(e) Report: CRDM Shroud," J. DeVincentis to R. W. Starostecki (f) PSNH Letter SBN-812, dated June 5,1985, " Interim 10CFR50.55(e) Report: CRDM Shroud," J. DeVincentis to R. W. Starostecki (g) Westinghouse Letter NAH-U-3395, dated June 27, 1985, " Loads on CRDM Cooling Shroud," D. R. Gregg to D. D. Boyle

Subject:

Final 10CFR50.55(e) Report: CRDM Shroud (CDR-84-00-14)

Dear Sir:

We previously reported in Reference (f) a potential 10CFR50.55(e) item to Region I regarding the seismic qualification of the Control Rod Drive Mechanism (CRDM) shroud.

Per Reference (g), Westinghouse has performed detailed analyses which have demonstrated the shroud's adequacy for its intended use as an intervening structural supporting element for the Class I Reactor Vessel Instrumentation 8508090639 850725 PDR ADOCK 05000443  !

S PDR I p P.O. Box 300 Seabrook, NH 03874 . Telephone (603) 474-9521

United States Nuclear Regulatory Commission Attention: Mr. Richard W. Starostecki Page 2 System piping and Class I Reactor Vessel Head Vent piping. Therefore, based on the results of Westinghouse's investigation, we have determined that this item is not a reportable deficiency in accordance with 10CFR50.55(e) criteria.

This is our final report on this item.

Very truly yours, f

.17 1J Sf,W1L Wende 16 . Johnson Vice President cc: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 t

1 l

l l.

William S. Jordan, III Donald E. Chick Diane Curran Town Manager Harmon, Weiss & Jordan Town of Exeter 20001 S. Street, N.W. 10 Front Street Suite 430 Exeter, NH 03833 Washington, D.C. 20009 Brentwood Board of Selectmen Robert G. Perlis RED Dalton Road Office of the Executive Legal Director Brentwood, NH 03833 U.S. Nuclear Regulatory Commission Washington, DC 20555 Richard E. Sullivan, Mayor City Hall Robert A. Backus, Esquire Newburyport, MA 01950 116 Lowell Street P.O. Box 516 Calvin A. Canney Manc hester, NH 03105 City Manager City Hall Philip Ahrens, Esquire 126 Daniel Street Assistant Attorney General Portsmouth, NH 03801 Augusta, ME 04333 Dana Bisbee, Esquire Mr. John B. Tanzer Assistant Attorney General Designated Representative of Office of the Attorney General the Town of Hampton 208 State House Annex 5 Morningside Drive Concord, NH 03301 Hampton, NH 03842 Anne Verge, Chairperson Roberta C. Pevear Board of Selectmen Designated Representative of Town Hall the Town of Hampton Falls South Hampton, NH 03827 Drinkwater Road Hampton Falls, NH 03844 Patrick J. McKeon Selectmen's Office Mrs. Sandra Gavutis 10 Central Road Designated Representative of Rye, NH 03870 the Town of Kensington RFD 1 Carole F. Kagan, Esquire East Kingston, NH 03827 Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Jo Ann Shotwell, Esquire Washington, DC 20555 Assistant Attorney General Environmental Protection Bureau Mr. Angi Machiros Department of the Attorney General Chairman of the Board of Selectmen One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Town Manager's Office U.S. Senate Town Hall - Friend Street Washington, DC 20510 Amesbury, MA 01913 (ATTN: Tom Burack)

Senator Gordon J. Humphrey Diana P. Randall 1 Pillsbury Street 70 Collins Street Concord, NH 03301 Seabrook, NH 03874 (ATIN: Herb Boynton)

-.