ML20133H355

From kanterella
Jump to navigation Jump to search
Amend 3 to License SNM-997 for Milwaukee School of Engineering,Amending License in Entirety
ML20133H355
Person / Time
Site: 07001040
(SNM-0997-A-03, SNM-997-A-3)
Issue date: 07/19/1985
From: Mallett B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20133H358 List:
References
NUDOCS 8508090309
Download: ML20133H355 (2)


Text

1 2

I PAGE oF PAGESi U.S.NUdLEAR REGULATORY COMMISSION

^* "

MATERIALS LICENSE jc Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Pub!!c Law 93 -438), and Title 10, l4 d[gulations, Chapter 1, Parts 30,31,32,33. 34,35,40 and 70, and in reliance on statements and representations !

i by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, j,pecial nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to

,,cransfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This j shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is j jet to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any g

,onditions specified below.

g LIC'"5" r[

In accordance with application dated February 18, 1985 1,

Milwaukee School of Engineerin8

3. License number SNM-997 is amended in its i

its entirety to read as follows:

li 9

2.

1025 North Milwaukee Street

~

I ji Milwaukee, WI 53201

~

~

7

4. Eipiration date July 31, 1990 m

l

,~

5. Docket or 070 01040 l

[

Reference No.

4 j

6.13yproduct, source, and/or

7. Chemical and/or physical
8. Maximum amount that licensee I

special nuclear material form

' may possess at any one time

.~

,(C dader this license j

A. Plutonium-239

'A.' Encapsulated as.Pu Bef A. 80 grams l

1 C

l neutronTsource' 3

l i

y a-

. *l

~

if j

9. Authorized Use

.(

3 y

A.

For use in a Visiflux 1 Model 1100 neutron howitzer for training of technicians

~

'J "

Lj and students.

i

_,.3y fCONDITIONSJ j

~

~

js

)

j 10.

Licensed material shall'be used only(at,the licensee's Fred >F. Loock Engineering j

Center, Department of Physics located ~at:912 N. Milwaukee = Street, Milwaukee, Wisconsin.

b s

i l

j 11.

The licensee shall comply with th'e provisions, of.. Title 10, Chapter 1, Code of Federal

-)

Regulations, Part 19, " Notices,' Instructions' arid Re' ports to Workers ; Inspections" and l

Part 20, " Standards for Protection Against'Ra'diation."

i 12.

Licensed material shall be used by, or under the supervision and in the physical g

presence of, Ronald A. Kobiske.

I 1

'i 13.

A.

Each encapsulated plutonium source designed for the purpose of emitting neutron j!

or gamma radiation shall be tested for leakage at intervals not to exceed i

six (6) months.

In the absence of a certificate from a transferor indicating l

that a test has been made within six (6) months prior to the transfer, a sealed i

source received from another person shall not be put into use until tested.

g j

I l

B.

The test shall be capable of detecting the presence of 0.005 microcurie of alpha 1

contamination on the test sample. The test sample shall be taken from the i

source or from appropriate accessible surfaces of the device in which the sealed

)

source is permanently or semipermanently mounted or stored. Records of leak j

test results shall be kept in units of microcuries and maintained for inspection l

jg by the Commission.

h3d i il 8508090309 850719

\\

l REG 3 LIC70 N

i I

{ SNM-_O997 PI)R B h v N mem m mim--wm>wn C'

'H j

e y y g g M 1m1M 1ME Lw1 M M M MI M MILEf ' El ^

AMMN hfgM'ghM

~NRG rurmYA MEMMMMM UWOM PAGE oF PAGES o so License number SNM-997 MATERIALS LICENSE p

l SUPPLEMENTARY SHEET 7UN01040 1

E I

Amendment No. 03 E

i U

l N

y If the test reveals the presence of 0.005 microcurie or more of removable alpha C.

g contamination, the licensee shall immediately withdraw the sealed source from l

use and shall cause it to be decontaminated and repaired by a person I

appropriately licensed to make such repairs or to be disposed of in accordance I

with the Commission regulations. Within five (5) days after determining that any source has leaked, the licensee shall file a report with the Material y

Licensing Branch, Division of Fuel Cycle and Material Safety, U. S. Nuclear j

g Regulatory Commission, Washington, D.C. 20555, describing the source, the test I

results, the extent of contamination, the apparent or suspected cause of source N

failure, and the corrective action taken. A copy of the report shall be sent to N

the U. S. Nuclear Regulatory Commission,, Region III, 799 Roosevelt Road, Glen U

h -l - (y??,r.,

g' Ellyn, Illinois 60137.

,, rv bsg q

t., p j

g s v b f g

Theperiodicleaktest[dandnotbeinguscd.

g D.

required by this conditionfdoes not apply to sealed g

sources that are stor,e The s'ources excepted from this g

g i

l test shall be tested'for leakage prior to any use or,tr'ansfer to another person R

H unless they have#blien leak tested within six (6) monthbprior to the date of F

use or transfer.n N

i i) lE li

  • k

,/f>(

14.

Except for plutoni,um contained in a med application, no plutonium, regardles,s o,ical deviceydesigned for-individual human y

g l

g

~

fgform,,shall-be delivered to a carrier for g

l l

shipment by air transport or transported'in,an'airhraft by the(licensee except in g

l N

packages the design'of which the NRC has:spe'cifically' approved for transport of k

l N

plutonium by air. i'"

jK

.. N

? j, '. '.

[

E-(p Qoj Q f qTTg y m

F; 15.

Sealed sources containing/lic'ensed' mat'eridlishal1 not be: opened ~"

E

~

1 O

Mi jU)f ks

d. '

(3 t

y 16.

Except as specifically,providedTotherwise by'this;1icense, the311censee shall possess g

s and use licensed material de~ scribed in Items'6, 7,:and 8 ofgthis license in n

c accordance with state'm5nts, representations,da'nd piecedures" contained in application E

l dated February 18, 1985(and letter dated 4Jtily 1, 1985. The' Nuclear Regulatory E

~

~

l j

Commission's regulations 9 hall govern the licensee's st'a,t'sments in applications or jE letters, unless the statements are more restrictive than the regulations.

lf

', J, Q

, ~

' ~

lg g

r l

l IlC lE l

l E

l i

lE-l l

Ig I

E E

E E

For the U.S. Nuclear Regulatory Commission fA E

g E'

l Original Signed g:

lDateJuly19, 1985 By Bruce S. Mallett E

i 4;

Materials Licensing Section, Region III E

N f

N COPY 4

5

}E N

E gl 1

aummmmmmmmmmm m w=mmmmmm=w - mmmmmmmmmsm mmmmmmmmmm.mmma