ML20133E934

From kanterella
Jump to navigation Jump to search
Forwards Insp Rept 50-445/85-06 on 850301-0430 & Notice of Violation
Date released: 05/26/2020 Download: ML20133E934


Insp Rept 50-445/85-06 on 850301-0430.Violation Noted: Procedure MDA-201 Did Not Provide Appropriate Instruction for Electrical & Mechanical Maint & Failure to Provide Procedure for Broken Seal Ring on Reactor Coolant Pump
ML20133E966
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 05/29/1985
From: Hunnicutt D, Kelley D, Will Smith
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20133E966 (9)
Notice of Violation from Insp on 850301-0430.Incomplete
ML20133E951
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 09/12/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
Download: ML20133E951 (2)
Forwards Insp Rept 50-445/85-06 on 850301-0430 & Notice of Violation
ML20133E931
Person / Time
Site: Comanche Peak Luminant icon.png
Issue date: 09/12/1985
From: Denise R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: COUNSIL W G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
References
Download: ML20133E931 (2)