.. g O Pub"cservice

= = --

2420 W. 26th Avenue, Suite 100D, Denver, Colorado 80211 fien$r7cY so201-0840 (303)571-7511 September 20, 1985 Fort St. Vrain Unit No. 1 P-85325 Re anal Administrator g [g g n q p U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 1000 L

SEP 3 01985 Arlington, Texas 76011 Ati.n : Mr. Dorwin Hunter j

Docket No. 50-267

SUBJECT:

Modification Concerning Moisture Ingress

REFERENCE:

PSC Letter, 0.R. Lee to E. H. Johnson, dated March 12, 1985 (P-85082)

Deae Mr. Hunter: of the referenced letter provided a brief description of helium circulator auxiliary system modifications designed to mitigate PCRV mois+ure ingress. This letter provides notification of a change to one of those modifications.

The flow elements referred to as Thermal Dispersion type ficw elements were calibrated and installed in the 'D' circulator buffer helium supply and return lines, per the commitment in the referenced letter. When these flow elements were functionally tested however, their performance at low helium pressure was not satisfactory. The i

Thermal Dispersion type flow elements were, therefore, removed for i

evaluation by the flow element nanufacturer, and will not be I

reinstalled at this time. The original laminar flow elements have been reinstalled and will be in operation for plant restart.

If you should have any questions on this matter, please contact Mr. M. H. Holmes at (303) 571-8409.

Very truly yours, OS$$$$Q kV 7Y pg7 D.W. Warembourg, Ma ager

[

Nuclear Engineering Division O)

DWW/JW:pa d

0 EC875

~

Td t 0

.-.