c

.

OCT 3

1985

.

'

Docket No. 50-440

The Cleveland Electric Illuminating

Company

ATTN: Mr. Murray R. Edelman

Vice President

Nuclear Group

Post Office Box 5000

,

Cleveland, OH 44101

'

Gentlenen:

This refers to the routine safety inspection conducted by Messrs. D. E. Hills

and G. F. O'Dwyer of this office on August 3 through September 13, 1985,

of activities at Perry Nuclear Power Plant, Unit 1, authorized by NRC

Construction Permit No. CPPR-148 and to the discussion of our findings with

Messrs. C. M. Shuster, G. R. Leidich, J. G. Cantlin and others of your staff

at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during

the inspection. Within these areas, the inspection consisted of a selective

examination of procedures and representative records, observations, and

interviews with personnel.

During this inspection, certain of your activities appeared to be in

violation of NRC requirements, as specified in the enclosed Appendix.

A written response is required. We are concerned that the violations

identified during this inspection are in the area of preoperational testing,

an area which was rated Category 3 in the last SALP report. We recognize

that we reviewed only one procedure reviewed by the Management Procedure

Review team and this may be an inadequate basis for a definitive conclusion

regarding the general effectiveness of licensee corrective actions on the

preoperational test program. We wish to discuss this matter with you and

your staff during the meeting currently scheduled for October 11, 1985.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of

this letter and the enclosures will be placed in the NRC's Public Document

Room.

851ooso131 851003

G

ADOCM 0500o440

PDR

-

h

k

_

-

.

(

.

GCT 3

1985

!

The Cleveland Electric Illuminating

2

Company

l

The responses directed by this letter (and the accompanying Notice) are

not subject to the clearance procedures of the Office of Management and

Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

We will gladly discuss any questions you have concerning this inspection.

[

Sincerely,

i

'A

LL

C. 'J.

Pa criello, Director

Division of Reactor Safety

Enclosures:

1.

Appendix, Notice

of Violation

2.

Inspection Report

No.50-440/85053(DRS)

cc w/ enclosures:

J. J. Waldron, Manager, Perry

Plant Technical Department

M. D. Lyster, Manager, Perry Plant

Operations Department

L. O. Beck, General Supervising

Engineer, Nuclear Licensing and

Fuel Management Section

DCS/RSD (RIDS)

Licensing Fee Management Branch

Resident Inspector, RIII

Harold W. Kohn, Ohio EPA

Terry J. Lodge, Esq.

James W. Harris, State of Ohio

Robert H. Quillin, Ohio

Department of Health

j

Q

kp

'f

"'lL s

c}V "\\!k ""yd ""!&f2 ['p!riq11o Hills /kja O'Dwyer Ring Knop i rfison