05000315/LER-1985-017, :on 850417,accumulated Leakage Exceeded Tech Spec Limits Found While Performing Type B & C Leak Rate Tests.Cause Unknown.Penetrations Repaired

From kanterella
(Redirected from ML20133C973)
Jump to navigation Jump to search
:on 850417,accumulated Leakage Exceeded Tech Spec Limits Found While Performing Type B & C Leak Rate Tests.Cause Unknown.Penetrations Repaired
ML20133C973
Person / Time
Site: Cook 
Issue date: 10/01/1985
From: Blind A
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
Shared Package
ML20133C971 List:
References
LER-85-017, LER-85-17, NUDOCS 8510070549
Download: ML20133C973 (1)


LER-1985-017, on 850417,accumulated Leakage Exceeded Tech Spec Limits Found While Performing Type B & C Leak Rate Tests.Cause Unknown.Penetrations Repaired
Event date:
Report date:
3151985017R00 - NRC Website

text

.

e e

. hKC Fer* 338 U $ NUCLE AR REGULATO2V COMMessiON 4 83' APPROVED OMS No 3t90-4104 LICENSEE EVENT REPORT (LER)

PLCILiTY NAME (11 DOCEET NUMGE R 821 PAGE4L D.C. COOK PLANT, UNIT 1 0151010 [ 013 l 115 1 lOFl0 l 1 ftTLE tet CONTAINMENT TYPE B AND C LEAK TESTS EVENT DATE ill LER NUMeER isk REPORT DATE (71 OTHER F ACILITIE S INVOLVED 141 MONTM DAY vtAR TEAR f,,,

WW W

VEM F @W' MW MUEI MM U N

8 0 151010101 I I 0l4 1l7 8

5 8 l5

~

0 l 1l7

~

0l1 1l0 0l 1 8l 5 0 I 5 I O 1 0 1 0 1 l l THIS REPORT 18 $USMITTED PUR$UANT TO THE REOutREMENTS 08 to CPR 5 tchwa one e,,nore e,,ae,ene.rae> st ts OPE R ATM 5

20 02mi 20 40s<.i 30 73..H2H i n 7imi R

20 405teH1Hd 50 3eicH1D 80 ?3,sH2ilvi 73 71te) 010t0 20 ace'.H1Hai so m.Hn 30 ni.H2n. i O,7MEgs, g Ag,w, (106 20 405ieH1Hdd X

80 73laH2Hd 60 73'aH2HvaeH Al J6641 20 406(eH1Heve to 73ieH21tal 80 73(eH2Hv=lisi 20 405teld1Het 50 73teH21twel 90 73.eH2 Hat LICEN$tE CONTACT FOR TMi$ LER (12)

NAME TELENONE NUV8ER ARE A (CQE A.A. BLIND - ASSISTANT PLANT MANAGER 611 16 4 l615 l -1519 I 011 COMPLETE ONE LINE FOR E ACM COMPONE%T F AILURE DESCRISED IN THIS REPORT (131

CAUSE

SY5TEV COvPON E NT

"'y g'0 TO C AL.,5 E

$ v 5TE V COvPONENT "f0 NPR PRC B

BI D i IlSIV Xl 91 % 9 Y

l t I t I l t i

I I I I I I I

I I I I I I SUPPLEMENTAL REPORT EXPECTED 114:

MONTH DAY TEAR SL 8 v r $$ 'O%

YES II, s.a c0*',44 EXPECTEC 3V0WSSION CA TEl

%O l

l l

t. T R A C T u,, M um,,-....,...

r.,,,,,,,,,..,-,,,,,, A m.,

THIS IS A REVISION 'IO LER 85-017 SUPMITIED ON MAY 9,1985.

CN APRIL 17,1985, AT 0250 HOURS, WITH TIE REACIOR COOIRE SYSTEM IN MODE 5 (00ID SHUIDOWN), THE ACCUMULATED LEAKAGE FOUND KHILE PERmPMING TIE TYPE B AND C LEAK RATE TESTS ON CONTAINMEtE PENETRATIONS EXrFmED THE L.C.O. VAIIE (0.60 L ) OF TECHNICAL SPECIFICATION 3.6.1.2.b.

THE FINAL TEST RESULTS FOR ALL TYPE B AND C LEAKAGE INDICATED AN AS-FOUND LEAKAGE OF 0.698L THE SUMMATICN OF THE 'IOTAL TYPE B AND C LEAKAGE WITH TIE 0.00666 PERCENT WEfGfr/ DAY (0.02664 L LEAKAGE VALUE FIOi TIE CURREtE UNIT 1 TYPE A TEST, YIELDS A LEAKAGE RATE OF 0.723)L, WHICH IS LESS THAN THE TECHNICAL SPECIFIC VALUE FOR 'IOTAL LEAKAGE.

TIE ANALYSIS CONDLCIED FOR THE FSAR, 'IO DLTERMINE ODtEROL ROCM HABITABILITY AND OFF-SITE DOSES, ASSUMED 'IIIE FULL L VALUE FROM TfE ONSLT OF THE ACCIDENT. BDCAUSE a

TIE AS-EDUND VALUE WAS LESS THAN l 0 L, IT IS CONCLUDED TIIAT TIE AS-FOUND LEAKAGE DID NCfr CONSTI'IUTE AN UNREVIEWED SAFEI@ QUESTION AS DE'INED IN 10 CFR 50.59, NOR WOULD IT HAVE ADVERSELY IMPACTED PUBLIC HEALTH AND SAFETY.

AN AS-LEET TYPE B AND C LEAK PATE OF.037 L WAS OBTAINED FOLIIMING REPAIR OF TIE a

INVOLVED PENETRATIONS.

PREVIOUS OOCURRENCES OF A SIMIIAR NA'IURE INCLUDE: 50-315/83-072, 50-315/82-058, 50-315/81-025, 50-316/81-018, 50-315/81-011, 50-316/79-053, 50-315/79-034, AND 50-316/79-020.

8510070549 851001 m.C 3